My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36524 Garden Wall Way
Zephyrhills
>
Building Department
>
Building Plans
>
36524 Garden Wall Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/17/2025 9:18:03 AM
Creation date
2/18/2025 3:20:46 PM
Metadata
Fields
Template:
Building Plans
Street #
36524
Location
Garden Wall Way
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 <br />a <br />rn <br />LO <br />0 <br />0 <br />.a <br />0 <br />0 <br />0 <br />J <br />N <br />0 <br />0 <br />I <br />N <br />Q <br />,n <br />to <br />Q <br />N <br />0 <br />0 <br />3 <br />N <br />S <br />I <br />LON <br />to <br />39 <br />a <br />Y <br />Q <br />M <br />d <br />i <br />n. <br />E <br />en <br />L <br />a <br />J <br />L� <br />E <br />15 <br />U <br />y <br />N <br />0 <br />0- <br />i <br />c <br />0 <br />v <br />U <br />J <br />a� <br />0 <br />0 <br />O <br />d <br />1M <br />0 <br />0 <br />Q <br />m <br />x4 1/2" DRYWALL DOOR JAMB (REFER 1x4 1/2" DRYWALL DOOR JAMB (REFER 1x4F1/2" DRYWALL <br />DOOR JAMB (REFER P.T . TO PRODUCT TO PRODUCT <br />TO PRODUCTAPPROVAL FOR CONN. APPROVAL FOR CONN. <br />APPROVAL FOR CONN. 1x4 F X 4 <br />1x4 P.T. 3/16" 0 X 3" LONG 711- <br />(07 ; FURRING <br />3-1/4" LONG X 3/t6"� FURRING FURRING (2) ROWS 3/16" x 3-1/2" <br />TAPCONS TAPCON 16" O.C. & 4" <br />TAPCON, INTO STAGGERED @ 16" 1x8 P.T. FROM EACH END w/ MIN. 1X8 <br />BLOCK@ SPACING „ O.C. 2-ROWS INTO <br />PER MANUFACTURE 1 DETAIL 2" EDGE DIST. ATTACH <br />MASONRY THROUGH 1-1 /2" DETAIL 1x8 w/ (2) ROWS 8d NALS �� <br />1x4 P.T. & 1x8 P.T. STAGGERED @ 12" O.C. 3 DETAIL <br />3/16" x 3 -1/2" DOOR JAMB (REFER <br />TAPCON @ 16" 1x4 P.T. TO PRODUCT <br />O.C. & 4" FROM DOOR JAMB (REFER 1/2" DRYWALL <br />DOOR JAMB (REFER EACH END W/ MIN. <br />TO PRODUCT APPROVAL FOR CONN. 1x4 <br />TO PRODUCT 2" EDGE DIST. APPROVAL FOR CONN. 2x8 P.T. w/ (2) ROWS 3/16" <br />APPROVAL FOR CONN. Px 3-112" TAPCON @ 16" 1x4 <br />(2) ROWS 3/16" x 3-1/2" O.C. & 4" FROM EACH <br />TAPCON @ 16" O.C. & END w/ MIN. 2" EDGE DIST. FURRIN( <br />4" FROM EACH END w/ 2x8 P.T. ATTACH SECOND PLY w/ <br />2x P.T. AS REQ'D MIN. 2" EDGE DIST. (2) ROWS 10dx3" 2x8 <br />2x DETAIL 2 1/4" DETAIL STAGGERED @ 12" O.C. 3-1/4" DETAIL <br />BUILDOUT OVER SIZE DOOR —WINDOW ROUGH OPENINGS CC <br />SCALE: N.T.S. SS <br />2x8 P.T. BUCK -CONNECT TO BLOCK <br />W/ 1/4" x 31/4" TAPCON (1 1/4" MIN. <br />EMBEDMENT INTO BLK.) <br />1 X 4 FURRING <br />BLOCK HEADER <br />1/2" DRYWALL <br />8d NAILS AT 8" O.C. AT BUCK <br />2 x 8 45^ DIAGONAL (4)10d NAILS INTO <br />' <br />BRACE(S) 2 x 8 BRACE/ BLKG. <br />7/16" OSB <br />BUILT UP PLWD. BUCK ARCH PANEL CUT HOLE IN O.S.B. FOR <br />SCRIBE (NOTCH) POLY -CELL IN THIS AREA <br />BACKSIDE TO FIT ARCH (4) 10d NAILS INTO 2 x 8 <br />CONNECT W/ 8d NAILS BRACE/ BLKG. <br />INSTALL WDW. SCREW ANCHOR 2 x 4 SOLID BLKG. (FULL WIDTH OF WALL) BTWN. OSB <br />INTO ARCH BLKG. PER ARCH FACES W (4)10d NAILS THRU OSB INTO 2 x 8 <br />INSTALLATION DETAILS A -A PROVIDE TAPCON PER WDW. INSTALLATION DETAILS OR THRU — \ <br />THK. OR MORE BUCK WITHIN 6" MIN. OF START OF ARCH <br />ARCH DETAIL J <br />SCALE: N.T.S. SS <br />BLOCK HEADER <br />1 X 4 FURRING <br />8d NAILS @ 8" O.C. AT BUCK <br />PROVIDE 2 x 8 DIAG. BRACE BT <br />VERT. BRACES WHEN HGT. OF <br />BRACE EXCEEDS 24" <br />2 x 8 VERT. BRACE(S) <br />BUILT UP PLWD. BUCK- — <br />SCRIBE (NOTCH) BACKSIDE <br />TO FIT ARCH CONNECT W/ <br />8d NAILS <br />INSTALL WDW, SCREW_____� <br />ANCHOR INTO ARCH BLKG. <br />PER INSTALLATION DETAILS <br />1/4" MAX <br />11 <br />IISOLID BLKG. AT TOP BTWN. <br />ARCH BLKG. & BUCK <br />2'-0" <br />2 x 8 BUCK - CONNECT TO BLOCK <br />WITH 1/4" x 31/4" TAPCON (1 1/4" MIN. <br />1/4" MAX EMBEDMENT INTO K.) <br />2'-0" <br />SOLID BLKG. AT TOP BTWN. ARCH <br />BLKG. & BUCK <br />2 x 8 VERT. W/ (2)10d <br />NAILS AT EA. END <br />LEAVE A CUT OUT IN O.S.B. ON T <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />7/16" OSB ARCH PANEL <br />2 x 4 SOLID BLKG. (FULL WIDTH OF WALLS) <br />BTWN. OSB ARCH FACES W/ (4) 10d NAILS EQUAL <br />THRU OSB INTO 2 x 8 <br />B—B ARCH DETAIL rK <br />SCALE: N.T.S. SS <br />I <br />SECTION <br />A -A <br />8" <br />1/4" x 3 1/4" TAPCONS <br />—LEAVE A CUT OUT IN O.S.B. ON THE <br />INSIDE TO ALLOW FOR INSULATION <br />TO BE INSTALLED <br />---2 x 8 45 DIAGONAL BRACE AT EA. <br />FACE OF ARCH W/ (3)10d NAILS <br />AT EA. END <br />\_ <br />PROVIDE TAPCON WITHIN <br />4" MIN. OF BRACE <br />START OF ARC <br />4' MAX. RAD. <br />SECTION <br />B-B <br />8" <br />PROVIDE 2x <br />PROVIDE (2) MIN. CONT. W/ (3) <br />TAPCON AT EA. SIDE 12d NAILS <br />BUCK- (1) WITHIN 4" <br />MIN. OF START OF <br />ARCH <br />START OF ARC <br />EQUAL I I 4' MAX. RAD. <br />PROPER INSTALLATION MAx.B <br />FILL SOLID <br />BOTH CELLS <br />#5 REBt <br />(TYP,) <br />STD. 90' <br />HOOK (1 <br />Ill <br />+5A <br />NOTCH WEB AT <br />FIRST 2 COURSI <br />' - 'rT ;APACITY = 805 # FOR 1 STRAP <br />=1610 # FOR 2 STRAPS <br />1 PLY PRE-ENGINEERED TRUSS <br />SIMPSON HM9KT w/ (4)1/4"x1 1/2" SDS <br />SCREWS & (5)1/4" x 21/4" TITEN (IF TRUSS <br />IS 2 PLY INSTALL SIMPSON LGT2 w/ (16)16d <br />SINKERS AND (7) 1/4"x21/4" TITEN = 2150 #) <br />BOND BEAM OR CAST IN PLACE BEAM <br />RETROFIT TRUSS DETAIL <br />N.T.S. <br />2X6 SYP #2 CONT. (MATCH TRUSS DEPTH <br />IF TRUSSES USED) W/ (3) #6 X 4Y2" WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY WALL <br />USE (1) SIMPSON 1/2" HD TITEN (CENTERED) w/ <br />MIN. 4" EMBEDMENT AT 16" O.C. <br />12 <br />JACK TRUSS PROVIDED BY SEE <br />TRUSS COMPANY OR PLAN <br />2x6 #2 SYP @ 24" O.C. <br />ROOF SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />12 <br />(5)d NAILS <br />SIMPSON <br />2X6 TO 2X4 <br />H2.5A w/ (10) <br />8d NAILS <br />. J <br />NOTE: <br />SHED ROOF ENDS TO BE <br />GABLE ONLY, CORNERS <br />SHALL NOT BE FRAMED AS <br />HIP, <br />DESIGNED ONLY FOR THE <br />INSTALLATION OF SHINGLE <br />AND METAL ROOF FINISH <br />I <br />GLASS BLOCK INSTALLATION NOTES <br />A) <br />COVER SILL AREA WITH A HEAVY COAT OF ASPHALT EMULSION. ALLOW EMULSION TO DRY <br />AT LEAST 2 HOURS BEFORE PLACING MORTAR. <br />B) <br />ADHERE EXPANSION STRIPS TO JAMBS AND HEAD. MAKE CERTAIN EXPANSION STRIP <br />EXTENDS TO SILL. <br />C) <br />SET A FULL MORTAR BED JOINT, APPLIED TO SILL. <br />D) <br />SET LOWER COURSE OF BLOCK. MAINTAIN A UNIFORM JOINT WIDTH OF 3/8" PLUS OR MINUS <br />1/8". ALL MORTAR JOINTS MUST BE FULL AND NOT FURROWED. ALL MORTAR SHALL BE <br />TYPE "S" OR "N". STEEL TOOLS MUST NOT BE USED TO TAP BLOCKS INTO POSITION. (PLACE <br />EXPANSION STRIP <br />A RUBBER CRUTCH TIP ON END OF TROWEL TO TAP BLOCK INTO POSITION.) DO NOT <br />20 ga. PANEL <br />REALIGN, TAP, OR OTHERWISE MOVE BLOCK AFTER INITIAL PLACEMENT. FOR SOLID GLASS <br />BLOCK IT MAY BE NECESSARY TO USE WEDGES IN THE MORTAR JOINTS OF THE LOWER <br />ANCHOR <br />COURSES TO PREVENT THE MORTAR FROM BEING "SQUEEZED" OUT. <br />1/4" EXPANSION BOLT (2 <br />E) <br />INSTALL PANEL REINFORCING IN EVERY OTHER MORTAR BED HORIZONTALLY AND IN JOINTS <br />9 ga. PANEL <br />PER ANCHOR) <br />IMMEDIATELY ABOVE AND BELOW ALL OPENINGS WITHIN PANELS. (THE SAME SPACING <br />REINFORCING <br />SHALL APPLY TO PANEL ANCHORS WHEN USED AT JAMBS AND HEADS IN LIEU OF CHANNEL <br />(EVERY OTHER <br />OR CHASE SURROUNDS.) RUN REINFORCING CONTINUOUSLY FROM END TO END OF PANELS. <br />COURSE) <br />EXPANSION STRIP <br />LAP REINFORCING NOT LESS THAN 6 INCHES WHENEVER IT IS NECESSARY TO USE MORE <br />THAN ONE LENGTH. DO NOT BRIDGE EXPANSION JOINTS WITH REINFORCING. INSTALL <br />REINFORCING AS FOLLOWS: <br />* PLACE LOWER HALF OF MORTAR IN BED JOINT. DO NOT FURROW. <br />SEALANT <br />PRESS PANEL REINFORCING INTO PLACE. <br />6" MIN. LAP SPLICE W/ <br />* COVER PANEL REINFORCING WITH UPPER HALF OF MORTAR BED AND TROWEL <br />REINFORCING PANEL <br />SMOOTH. DO NO FURROW. <br />F) <br />PLACE FULL MORTAR BED FOR JOINTS NOT REQUIRING PANEL REINFORCING - DO NOT <br />FURROW. MAINTAIN UNIFORM JOINT WIDTH. <br />6"MIN. LAP <br />G) <br />SET SUCCEEDING COURSE OF BLOCKS. SPACE AT HEAD OF PANEL AND JAMBS MUST <br />SPLICE <br />REMAIN FREE OF MORTAR. <br />NOTE: <br />H) <br />STRIKE JOINTS SMOOTH WHILE MORTAR IS STILL PLASTIC AND BEFORE FINAL SET. AT THIS <br />SEE GLASS BLOCK INSTALLATION NOTES. <br />TIME RAKE OUT ALL SPACES REQUIRING SEALANT TO A DEPTH EQUAL TO THE WIDTH OF THE <br />SEALANT <br />SPACES. REMOVE SURPLUS MORTAR FROM FACES OF GLASS BLOCKS AND WIPE DRY. <br />GLASS BLOCK DETAIL <br />TOOL JOINTS SMOOTH AND CONCAVE, BEFORE MORTAR TAKES FINAL SET. (REMOVE <br />WEDGES FROM LOWER COURSES OF SOLID BLOCKS AND POINT THE VOIDS WITH MORTAR.) <br />GLASS BLOCK SHALL BE INSTALLED PER THE FLORIDA BUILDING CODE RESIDENTIAL SECTION R160 <br />1) <br />AFTER FINAL MORTAR SET (APPROX. 24 HOURS), INSTALL PACKING TIGHTLY BETWEEN <br />GLASS BLOCK PANEL AND JAMB AND HEAD CONSTRUCTION. LEAVE SPACE FOR SEALING. <br />J) <br />APPLY SEALANT EVENLY TO THE FULL DEPTH OF RECESSES IN ACCORDANCE WITH THE <br />MANUFACTURER'S APPLICATION MANUAL AND INSTRUCTIONS. <br />K) <br />A MAXIMUM OF 60 SQUARE FEET OF GLASS BLOCK MAY BE INSTALLED IN ANY OPENING. <br />FOR WIND SPEEDS UP TO 110 MPH*, PER PITTSBURG CORNING RECOMMENDATIONS FOR <br />INSTALLATION OF GLASS BLOCK. <br />JACK TRUSS PROVIDED BYE <br />TRUSS COMPANY OR 2X4 <br />#2 SYP @ 24" O.C. <br />4'-0" MAX SEE PLAN <br />2X4 SYP #2 CONT (MATCH TRUSS DEPTH —� <br />IF TRUSSES USED) W/ (2) #6 X 4Y2" WOOD <br />SCREWS @ 16" O.C. MAX. OR IF MASONRY <br />WALL USE (2) 1/4" X 3 1/2" TAPCONS AT 16" <br />O.C. <br />SECTION @ ENTRY rL <br />SCALE: 3/4" = V-0" SS <br />/ f <br />L <br />MASONRY WALL. SEE PLAN FOR <br />REINFORCING. PROVIDE LOWER <br />HOOKED DOWEL <br />W.W,M. AT PERIMETER <br />WHERE THIS CONDITION <br />#5 CONT. TOP & MID OCCURS <br />WITH MIN. 3" COVER 6-0" <br />XF <br />ko <br />1=1 I I-1 —T 111=TfTr <br />D <br />I11 <br />F= <br />—TI—I I r <br />GRADE <br />CV p <br />M Z <br />r <br />D (2) #5 REBAR. (1-STORY) <br />16" MIN. (1-STORY) (3) #5 REBAR. (2-STORY) <br />20" MIN. (2-STORY) WITH MIN. 3" COVER EA. WAY <br />SECTION AT DEEP MONO FOUNDATION <br />REV. 07.28.21 <br />SCALE: 3/4" = V-0" <br />FILLED CELL PER <br />FOUNDATION PLAN <br />UNACCEPTABLE INSTALLTION <br />DO NOT DO THIS <br />A <br />P <br />THE <br />S <br />FILLED CELL INSTALLATION <br />SEE ARCH PLAN AND <br />PRE-ENG TRUSS DESIGN <br />SEE NOTE 1 BELOW <br />BRG WALL TYPE - <br />PER PLAN <br />F CHANNEL, <br />FASTENED PER <br />NOTE 2 BELOW <br />CONT 2x4 NAILED TO <br />BLOCKING w/ 2-12d NAILS (**) <br />#5 REBAR (TYP,) <br />00 <br />TD. 90° HOOK (TYP.) <br />SCALE: N.T.S. <br />2x SUB FASCIA <br />• ALUM DRIP EDGE <br />• ALUM FASCIA <br />1-3/4" TRIM PAINTED <br />SS NAIL w/ 5/16" HEAD <br />DIA. @ 24" O.C. <br />CONT VENTED OR SOLID SOFFIT <br />2x BLOCKING NAILED TO TOP <br />CHORD EVERY OTHER TRUSS <br />W/ 3-12d NAILS, TYP. (**) <br />1. G.C./ BUILDER TO VERIFY/PROVIDE SOFFIT MATERIAL SPAN CAPACITIES BASED <br />ON THE DESIGN PRESSURES SPECIFIED FOR COMPONENTS AND CLADDING <br />LISTED IN THE DESIGN CRITERIA ON SHEET SN. <br />2. FOR SOFFIT ATTACHMENT AT WALL (PER ALPHA ALUM. INC. FL# 16544 R5 FL <br />PRODUCT APPROVAL) F CHANNEL FASTENED TO: <br />CMU WIT NAIL .097" DIA. @ 24" O.C. w/ 5/8" MIN. EMBEDMENT <br />WOOD W/ (3) 16 GA. 3/4"x1/4" CROWN STAPLES @ 24" MAX. O.C. IN DIAMOND <br />PATTERN <br />SUB FASCIA w/ 16 GA. 3/4"x1/4" CROWN STAPLE @ EACH GROOVE <br />STRUCTURAL SOFFIT <br />SF01 <br />SCALE: 3/4" = V-0" (**) FOR ALUMINUM SOFFITS WITH SPANS <br />REV. 09.23.2021 > V-4", INSTALL MID SPAN BLOCKING PER <br />THE SOFFIT FL PA INSTALLATION CRITERIA <br />*REFER TO THE PRODUCT APPROVAL FOR INSTALLATION DETAILS.* <br />2X <br />+ + t FNGTH <br />+ + <br />+ + <br />+ + <br />+ + <br />+ . <br />TRUSS <br />2X4 SYP — <br />EACH TRUSS <br />CONNECTOR <br />SEE LINTEL- <br />SCHED. <br />PRECAST LINTEL <br />2 X 4 #2 SYP SCAB TO SIDE OF <br />TRUSS AS SHOWN FOR O.H. UP TO Z-6" <br />* DOUBLE 2x4 SCAB FOR 2'-6" TO 4'-0" O.H. <br />(2)10d NAILS @ 8" O.C. <br />TO TRUSS TOP CHORD <br />PLYWOOD SHEATHING <br />BLOCKING AS <br />r + REQUIRED TO <br />�\ + SUPPORT SOFFIT <br />If J1V' SEE ELEVATION <br />,L_ <br />J` FOR OVER HANG <br />(MAX. 4'-0") <br />SECTION @ ROOF EXTENSION ("M� <br />SCALE: 3/4" = V-0" SS <br />QGG QWP:F:T fly AAIII <br />SIMPSON HTT4 w/ (18)10d x 1 <br />1/2" NAILS TO STUDS & (1) - <br />5/8" DIA. ALL THREAD ROD <br />EPDXIED w/ SIMPSON "SET" <br />EPDXY MIN. 6" EMBEDMENT 8 <br />3" MIN. EDGE DISTANCE <br />RETROFIT FOR MIS <br />MSTAM STRAP <br />SCALE: 3,-. <br />w <br />z <br />0 <br />2 <br />U_ <br />0 <br />LU <br />U_ <br />M <br />U <br />fn <br />@ FIRST COURSE <br />ATTACHED WALL SHEATHING TO <br />2X BOTTOM PLATE W/ 8d @ 4" <br />O.C., 2 ROWS STAGGERED <br />,-2x BAND JOIST W/ FACE NAIL 1 Od <br />@ TOP & BTTM CHORD, AND (8) <br />FACE NAILS 10d @ TRUSS VERT. <br />WEB <br />METAL SEAT PLATE <br />NOTE: <br />LAP SHEATHING TO <br />BOTTOM OF BAND <br />JOIST TYPICAL <br />SIMPSON HGAM10KTA @ 12" O.C. <br />w/ (4) 1/4xl 1/2" SDS SCREWS <br />INTO BAND JOIST & (4) 1/4"x2 3/4" <br />TITEN INTO K.O. BLOCK <br />RETROFIT FOR MISSING EMBEDDED STRAP <br />SEE TYP. 2-STORY WALL SECTION FOR ADDL. INFO SCALE: N.T.S. <br />2"x BOT. PLATE W/ (2) 10d @ 6" O.C. <br />3/4" PLYWOOD DECKING GLUED <br />AND NAILED W/ 8d COMMON @ <br />6" O.C. EDGES AND 12" O.C. FIELD <br />FILL 1st 4 COURSES <br />SOLID W/GROUT <br />FOR OVERHANGS BETWEEN OVER 1 1/2" <br />CONTACT ENGINEER OF RECORD FOR <br />FURTHER INSTRUCTIONS. ° <br />a' <br />OVERHAN y. �;.• <br />n' <br />RETROFIT WALL OVERHANG DETAIL (NTS <br />FOR OVERHANGS BETWEEN 3/4" TO 1 1/2" <br />NOTE: FOR OVERHANGS LESS THAN 3/4" - NO REPAIR REO'D. <br />1 t-0tt 51 <br />-011 <br />P. <br />• ' •Ill... ' #5 BAR x <br />V 1.0 • • : .• CENTERED W/ g <br />o.,'• •. .'� 9 H IN TOP o <br />KNOCKOUT/ N <br />° CHAIR BLOCK <br />MONO FOOTING <br />SIZE AND REINF. PER PLAN • <br />AND SECTION DETAILS <br />CLEAN FILL .o ° • • v <br />DIRT Z <br />°• ° ffTANDARD CDHOOK N <br />#5 BAR IN _ <br />FILLED CELL, , <br />STEMWALL FOOTING SIZE AND <br />MONO TO STEMWALL FOOTING REINF. PERLAN AND STEMWALL <br />SECTION DETAILS <br />SCALE: 3/4" = 1'-0" <br />)TE: IF RETROFIT FILLED CELL CONDITIONS EXCEED (3) PER PROJEC <br />)NTACT ENGINEER OF RECORD FOR ADDITIONAL INSTRUCTION. <br />EXISTING BOND BEAM. <br />DRILL 3/4"x5" MIN. HOLE SET BAR IN <br />EPDXY CAP TO PREVENT LEAKAGE <br />TOP SPACE BETWEEN EXISTING GROUT & NEW GROUT <br />MUST BE PACKED WITH NON -SHRINK GROUT (USUALLY ± 2") <br />#5x6' EMBEDDED INTO EXISTING BOND BEAM <br />FILL CELL FULL HEIGHT W/ <br />NON SHRINK GROUT. <br />#5x6 EMBEDDED INTO <br />EXISTING FOOTING <br />DRILL 3/4"x5" MIN. HOLE <br />SET BAR IN EPDXY <br />I I— EXISTING FOOTING <br />RETROFIT FILLED CELL DETAIL <br />4" SAW CUT <br />A SECTION <br />j SCALE: N.T.S. <br />SCALE: N.T.S. <br />e� <br />N <br />C14 <br />g <br />sr,n <br />=o <br />LA <br />Y o <br />a� o <br />m C,4 <br />en �a o <br />N <br />N g <br />Q d <br />•� <br />o�Q <br />' <br />c ra <br />f co <br />H <br />g <br />N <br />L3. <br />r <br />12 <br />1��if6p�f�,��`v�jr <br />., wg�aQt��V-130my <br />x <br />. N0 <br />F LO <br />�N,�,�� <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer`s signature and seal. <br />k W <br />a, <br />E <br />o N8 0 <br />w 5 o <br />a0 <br />'5 i; °�� � <br />ai <br />cN�o <br />CO ti n <br />M V � LL <br />N J <br />17 10to <br />a <br />'? <br />ZN-C� <br />a <br />JLLLr"Lu <br />d Y <br />rjoo Z <br />p; <br />=1 o 0 <br />W <br />(0 T m <br />Z <br />J <br />MZ ¢ <br />N <br />O U ¢ o0 <br />��er at a+il W <br />❑ ❑ <br />z N M <br />a <br />z N <br />z � � <br />J <br />d N <br />N <br />z a <br />�N <br />0 o <br />.O <br />N <br />�N <br />LU o <br />N <br />kM <br />,r <br />U <br />Lu ° <br />!— <br />I <br />�'jE. <br />_ w <br />U o <br />r~ � Y <br />Q m <br />° <br />�m <br />r_ <br />C <br />w <br />M <br />M <br />� <br />z <br />Z <br />a <br />Q 0 <br />o <br />E U <br />ow <br />z© <br />oa <br />ro <br />2a0. <br />�o <br />E <br />� P6 <br />&4 <br />o <br />¢ <br />0¢ <br />az <br /><o <br />w z <br />rm <br />O <br />mo <br />m � <br />� J <br />Q W <br />�z <br />¢� <br />o< <br />a0 <br />W <br />f� <br />T <br />WLL <br /><O <br />z <br />oW <br />F� <br />o� <br />w= <br />�3 <br />w <br />'0 <br />ch <br />o�< <br />a = <br />°§ <br />�� <br />> C4 <br />J <br />L0 <br />� <br />m <br />Q <br />� <br />� <br />� <br />N <br />C) <br />O <br />Y <br />— <br />T <br />U) m <br />� <br />N <br />m <br />N <br />r <br />Q <br />•� <br />O <br />N <br />0) <br />I <br />co o <br />0 CV <br />LO <br />r <br />T— <br />T <br />T <br />Ch <br />o <br />z <br />zN <br />E Q <br />N <br />m <br />E <br />a w <br />c <br />JOB <br />NO : <br />23-00522 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SS <br />_r-i rt <br />
The URL can be used to link to this page
Your browser does not support the video tag.