<br />DIVISION NO. 7 THERMAL AND MOISTURE PROTECTION:
<br />007210 BUILDING INSULATION
<br />A. MATERIALS:
<br />1. BATT INSULATION: FIBERGLASS BATTS, 16" & 24" WIDTHS.
<br />a. KRAFT FACED, ASTM C665-86, TYPE II, CLASS C,
<br />PERM RATING OF1.0 MINIMUM.
<br />b. "R" VALUE FOR THERMAL RESISTANCE:
<br />(1) EXTERIOR WALL - FULL HEIGHT R-19,
<br />(2) CEILING - R-30 PLACED IN PLANE OF BOTTOM CHORD
<br />OF TRUSSED RAFTERS ROOF FRAMING.
<br />(3) ROOF DECK - R-19. UNLESS OTHERWISE INDICATED.
<br />2. OPEN CELL SPRAY FOAM INSULATION
<br />a. OPEN CELL FOAM, R-VALUE TESTED WITH ASTM C-518
<br />b. "R" VALUE FOR THERMAL RESISTANCE:
<br />NOMINAL R-VALUE OF 6 PER INCH THICKNESS.
<br />c. APPLY A MINIMUM OF 5 INCHES OF THICKNESS TO BOTTOM
<br />SIDE OF ROOF DECK, R-30 REQUIRED.
<br />d. INSTALL REQUIRED IGNITION BARRIER AS RECOMMENDED BY
<br />MANUFACTURER. ICYNENE BLAZLOK 1B4 OR EQUAL.
<br />e. RECOMMENDED MANUFACTURERS: LAPOLLA: FOAM-LOK, ICYNENE,
<br />NCFI POLYURETHANES: INSULSTAR, OR EQUAL.
<br />3. SOUND BATT INSULATION: UNFACED GLASS FIBER - ASTM C 665
<br />TYPE 1 & ASTM E 136.
<br />a. SIZE: R-VALUE 11.0 WHEN TESTED WITH ASTM C 518.
<br />b. VAPOR RETARDER PERM RATING: 1.0 WHEN TESTED WITH
<br />ASTM C 518.
<br />c. SURFACE BURNING CHARACTERISTICS:
<br />(1) UNFACED INSULATION
<br />(2) MAXIMUM FLAME SPREAD: 10
<br />(3) MAXIMUM SMOKE DEVELOPED: 10
<br />(4) WHEN TESTED IN ACCORDANCE WITH ASTM E 84.
<br />d. DIMENSIONAL STABILITY: LINEAR SHRINKAGE LESS THAN 0.1 %.
<br />4. RIGID EXTRUDED POLYSTYRENE INSULATION (WEPS) SHEATHING.
<br />AMOCO FOAM PRODUCTS, INC. - AMOFOAM-SL; DOW CHEMICAL USA -
<br />STYROFOAM SCORE BOARD.
<br />5. PERIMETER INSULATION: RIGID EXTRUDED POLYSTYRENE PERIMETER
<br />INSULATION (XEPS): (IF REQUIRED BY APPLICABLE CODE.
<br />PRODUCTS: AMOCO FOAM PRODUCTS, INC. - AMOFOAM-CM
<br />DOW CHEMICAL USA - STYROFOAM SQUARE EDGE.
<br />6. KRAFT BACK INSULATION SHALL NOT BE EXPOSED UNDER ANY CIRCUMSTANCE.
<br />ALL KRAFT BACK INSULATION IN WALLS ABOVE CEILING SHALL BE PROTECTED WITH
<br />GYPSUM BOARD SHEATHING.
<br />1. CHARACTERISTICS:
<br />a. EXTRUDED MATERIALS, CLOSED CELL POLYSTYRENE BOARD,
<br />ASTM C578-87a, TYPE IV.
<br />b. THICKNESS 1 1 /2"
<br />c. DENSITY: 2.0 PCF, MINIMUM.
<br />d. "K" VALUE ® 75' F: 0.20
<br />e. COMPRESSIVE STRENGTH: 20 MINIMUM 1.1 PER -IN, TESTED PER
<br />ASTM D 1621-73.
<br />f. WATER VAPOR TRANSMISSION: MAXIMUM 1.1 PERM -IN, ASTM E96-80,
<br />PROCEDURE B.
<br />g. SIZE: 2'-0" x 8'-0".
<br />h. EDGES: SQUARE.
<br />i. EACH BOARD MARKED TO INDICATE CODE COMPLIANCE.
<br />DIVISION NO. 7 THERMAL AND MOISTURE PROTECTION:
<br />007270 FIRESTOPPING
<br />A. MATERIALS:
<br />1. PENETRATIONS, SMOKE AND FIRE, NOT REQUIRING INTUMESCENT QUALITIES.
<br />FOAMING TYPE: DOW CORNING CO. - RTV 2001; GENERAL ELECTRIC
<br />CO. - PENSIL RTV851.
<br />2. SEALANTS: DOW CORNING CO. FIRE STOP NO. 2000; FLAME STOP, INC. FLAME
<br />STOP V CAULKING/TROWELLABLE.; GENERAL ELECTRIC CO. - RTV 7403;
<br />METALINES, INC. METALCAULK SERIES; NELSON ELECTRIC NELSON CMP;
<br />STANDARD OIL ENGINEERED MATERIALS - FIBERFRAX SERIES; 3M CO/ELECTRICAL
<br />PRODUCTS DIVISION - INTERAM FIREDAM 150 CAULK.
<br />3. STRIP OR WRAP: DOW CORNING CO. - FIRE STOP 2002 INTUMESCENT WRAP STR.;
<br />3M CO./ELECTRICAL PRODUCTS DIVISION - FIRE BARRIER.
<br />4. PUTTY: FLAME STOP, INC. FLAMES STOP V PUTTY; NELSON ELECTRIC - NELSON FSP,
<br />FLAMESEAL.; 3M CO/ELECTRICAL PRODUCTS DIVISION - FIRE BARRIER CAULK 3303.
<br />5. TAPE: 3M CO/ELECTRICAL PRODUCTS DIVISION - INERAM T-49.
<br />6. SAFING INSULATION: FIBREX - FBX SAFING INSULATION; MANVILLE CORP. - PYRO-FIBER
<br />SAFING INSULATION; USG ACOUSTICAL PRODUCTS CO. - THERMAFIBER SAFING INSULATION.
<br />a. CHARACTERISTICS: BLOWN, BONDED, COMPRESSIBLE, SEMI -RIGID, MINERAL FIBER
<br />BLANKET PER ASTM C612-83, CLASS 3.
<br />b. DENSITY: SIX (6) PCF, NOMINAL
<br />c. COMBUSTIBILITY: NON-COMBUSTIBLE PER ASTM E136-82.
<br />d. FLAME SPREAD: 15 PER ASTM E84-87.
<br />e. ACCESSORIES: PROVIDE MFR.'S STANDARD IMPALING CLIPS.
<br />B. PENETRATIONS, SMOKE AND FIRE, REQUIREMENT INTUMESCENT QUALITIES, SUCH AS PVC PIPE
<br />OR OTHER DISSOLVING MATERIALS.
<br />1. SEALANTS: FLAMES STOP, INC. -FLAMES STOP V CALKING/TROWELLABLE;
<br />STOP V CAULKING/TROWELLABLE.; ETALINES, INC. METALCAULK SERIES; 3M CO/ELECTRICAL
<br />PRODUCTS DIVISION - FIRE BARRIER CAULK CP-25.
<br />2. STRIP OR WRAP: DOW CORNING CO. - FIRE STOP 2002 INTUMESCENT WRAP STRIP;
<br />3M CO./ELECTRICAL PRODUCTS DIVISION - FIRE BARRIER WRAP/STRIP FS-195.
<br />3. PUTTY: FLAME STOP, INC. - FLAMES. STOP V PUTTY; NELSON ELECTRIC - NELSON
<br />FLAMESEAL.; 3M CO/ELECTRICAL PRODUCTS DIVISION - FIRE BARRIER CAULK 303.
<br />4. TAPE: 3M CO/ELECTRICAL PRODUCTS DIVISION - INERAM T-49.
<br />5. SHEET: 3M CO/ELECTRICAL PRODUCTS DIVISION - COMPOSITE SHEET CS-195.
<br />6. KITS FOR ROUND & RECTANGULAR PENETRATIONS: 3M CO./ELECTRICAL PRODUCTS DIVISION
<br />7902 AND 7904 SERIES.
<br />5. SAFING INSULATION: FIBREX - FBX SAFING INSULATION; MANVILLE CORP. - PYRO-FIBER
<br />SAFING INSULATION; USG ACOUSTICAL PRODUCTS CO. - THERMAFIBER SAFING INSULATION
<br />a. CHARACTERISTICS: BLOWN, BONDED, COMPRESSIBLE, SEMI -RIGID, MINERAL FIBER
<br />BLANKET PER ASTM C612-83, CLASS 3.
<br />b. DENSITY: SIX (6) PCF, NOMINAL
<br />c. COMBUSTIBILITY: NON-COMBUSTIBLE PER ASTM E136-82.
<br />d. FLAME SPREAD: 15 PER ASTM E84-87.
<br />e. ACCESSORIES: PROVIDE MFR.'S STANDARD IMPALING CLIPS.
<br />6. PENETRATIONS, SMOKE AND FIRE, REQUIREMENT INTUMESCENT QUALITIES, SUCH AS
<br />PVC PIPE OR OTHER DISSOLVING MATERIALS.
<br />DIVISION NO. 7 THERMAL AND MOISTURE PROTECTION:
<br />007310 COMPOSITION SHINGLES (THIS SECTION APPLIES ONLY WHERE SCHEDULED OR
<br />APPLICABLE UNDER THE MBBI WORK REQUIREMENTS)
<br />A. MATERIALS:
<br />1. LAMINATED FIBERGLASS BASE SHINGLES:
<br />a. CERTAINTEED CORP. - HALMARK SHINGLES
<br />b. GAF CORP. TIMBERLINE.
<br />c. TANKO - HERITAGE M30.
<br />2. CHARACTERISTICS:
<br />a. FIBERGLASS FELT SHINGLES PER ASTM D3018-82, TYPE 1.
<br />b. MEETS UL CLASS A FOR FIRE RESISTANCE.
<br />c. MEETS UL STANDARDS FOR WIND RESISTANCE.
<br />d. PROVIDE SHINGLES W/ SELF SEALING STRIPS.
<br />e. PROVIDE MANUFACTURER'S MIN. 20 YEAR WITH NO DOLLAR LIMIT.
<br />f. COLOR: AS SELECTED BY ARCHITECT FROM MFR.'S STANDARD COLORS.
<br />3. -ACCESSORIES:
<br />a. ROOFING FELTS, UNDERLAYMENT: MEETS ASTM D226-87, TYPE 1, 30
<br />LBS PER SQUARE, ASPHALT SATURATED ORGANIC FELT, 3'-0" WIDE,
<br />UNPERFORATED.
<br />b. NAILS: HOT -DIPPED GALVANIZED, 10 )� GAUGE RINGED SHANK; LENGTH
<br />TO PENETRATE ROOF DECK, MINIMUM -Y4".
<br />c. STAPLES: ZINC COATED, 16 GAUGE STAPLES, 1" NOMINAL CROWN.
<br />d. RIDGE SHINGLES: MATCH COLOR OF EXISTING SHINGLES.
<br />DIVISION NO. 7 THERMAL AND MOISTURE PROTECTION:
<br />007460 VINYL SIDING (THIS SECTION APPLIES ONLY WHERE SCHEDULED
<br />OR APPLICABLE UNDER THE MBBI WORK REQUIREMENTS.)
<br />A. MATERIALS:
<br />1. VINYL SIDING: ALCOA LIBERTY - DOUBLE 4" - ALCOA BUILDING PRODUCTS;
<br />DOUBLE IV - ALSIDE; FOREST RIDGE - DOUBLE 4" - GEORGIA PACIFIC.
<br />2. SOLID VIYL SIDING: EXTRUDED POLY VINYL CHLORIDE (PVC) COMPOUND PER
<br />ASTM D3769, "STANDARD SPECIFICATION FOR PVC SIDING"
<br />3. COLOR: AS SELECTED BY ARCHITECT FROM MFR.'S STANDARD COLORS.
<br />4. TRIM & ACCESSORIES: SAME MFR. AS VINYL SIDING, COLOR TO MATCH VINYL
<br />SIDING AND SOFFIT.
<br />B. VINYL SOFFIT:
<br />1. MANUFACTURERS:
<br />a. PRO -TECH PLUS - ALCOA BUILDING PRODUCTS.
<br />b. SERIES E SMOOTH PREMIUM - ALSIDE, INC.
<br />c. T/4 CENTER VENT SOFFIT - GEORGIA PACIFIC CORP.
<br />d. NOTE: PROVIDE SUPERSPAN HEAVY GAUGE PREMIUM SOFFIT
<br />® ENTRANCE CANOPY, ALSIDE, INC. OR EQUAL.
<br />2. SOLID AND VENTILATED SOFFIT: EXTRUDED POLY CHLORIDE (PVC)
<br />COMPOUND PER ASTM D 3769 " STANDARD SPECIFICATION FOR
<br />PVC SIDING.
<br />3. COLOR AS SELECTED BY ARCHITECT FROM MFR.'S STANDARD COLORS.
<br />C. ALUMINUM FASCIA:
<br />1. ALCOA BUILDING PRODUCTS - F2C6.
<br />2. -ALSIDE, INC. - 6" SMOOTH.
<br />3. GEORGIA PACIFIC - 6" SMOOTH.
<br />DIVISION NO. 7 THERMAL AND MOISTURE PROTECTION:
<br />007600 FLASHING AND SHEET METAL:
<br />(THIS SECTION APPLIES ONLY WHERE SCHEDULED
<br />OR APPLICABLE UNDER THE MBBI WORK REQUIREMENTS)
<br />A. MATERIALS:
<br />1. GALVANIZED SHEET METAL 24 GAUGE PAINT GRIP, UNCOATED THICKNESS
<br />COMMERCIAL GRADE PAINT GRIP GALVANIZED STEEL, - ASTM A525-87,
<br />COATING DESIGNATION G140, ZINC COATING NOT LESS THAN
<br />1.2 OZ ZINC. PSF.TAINTEED CORP. - HALMARK SHINGLES
<br />2. • GUTTERS & DOWNSPOUTS -ALUM OGEE-0.019" GAUGE MINIMUM.
<br />DOWNSPOUTS IN FRONT TO EXTEND & SPILL -OUT ® CURB & GUTTER.
<br />DOWNSPOUTS - OTHER AREAS - SPILL -OUT ® GRADE ON PRECAST
<br />CONCRETE SPLASHBLOCKS.
<br />3. FLEXIBLE FLASHING -
<br />a. ABOVE GRADE - 5 OZ COPPER LAMINATED FLEXIBLE THRU-WALL
<br />FLASHING - POLYTITE, SANDELL OR YORK.
<br />b. BELOW GRADE - 0.056 MIL, 6.2 OZ PSF POLLYVINYL CHLORIDE
<br />MEMBRANE FLASHING - YORK - WASCOSEAL 60, POLYTITE.
<br />4. MORTAR DEFLECTION DEVICE FOR CAVITY WALLS - MORTAR MAZE,
<br />MORTAR NET.
<br />IVISION NO. 7 THERMAL AND MOISTURE PROTECTION:
<br />007920 SEALANT
<br />AND CAULKING:
<br />A. MATERIALS:
<br />1.
<br />SILICONE SEALANTS
<br />a. CHEMREX, INC. - OMNISEAL
<br />b. DOW CORNING CORP NO. 790.
<br />c. GE SILICONES - SILGLAZE
<br />d. PECORA CORP. - NO. 864
<br />e. TREMCO INC. - SPECTREM 1
<br />2.
<br />ACRYLIC LATEX CAULKING COMPOUND:
<br />a. BOSIK CONST. PROD. DIV. - CHEM CALK 600
<br />b. CHEMREX - SONOLAC
<br />c. W R MEADOWS, INC. - EASAPLY
<br />d. PECORA CORP. AC-20
<br />e. TREMCO, INC. ACRYLIC LATEX CAULK
<br />3.
<br />BUTYL CAULK -
<br />a. PECORA CORP - BC-158
<br />b. TREMCO, INC. BUTYL SEALANT
<br />DIVISION NO. 8 DOORS AND WINDOWS:
<br />008100 HOLLOW METAL DOORS AND FRAMES:
<br />A. MATERIALS:
<br />1. METALS
<br />a. ASTM A366-85, COLD ROLLED STEEL SHEETS.
<br />b. EXTERIOR DOORS AND FRAMES - ZINC COATED PER
<br />ASTM A525-87
<br />c. WIPE COAT GALVANIZED STEEL COMPONENTS ARE PROHIBITED.
<br />2. PRIMER COAT:
<br />a. PRIME COAT OVER STEEL - ONE COAT MFR.'S STANDARD
<br />BAKED -ON ENAMEL RUST -INHIBITIVE PRIMER, 0.7 DFT MIN. THICKNESS.
<br />b. ONE COAT MFR'S STANDARD BAKED ON ENAMEL RUST -INHIBITIVE
<br />PRIMER, AFTER PAINT ADHESION TREATMENT, 1.0 MIL DFT.
<br />3. MANUFACTURED DOOR UNITS:
<br />a. DOORS - EXTERIOR UNITS
<br />INSULATED TYPE, GRADE III, EXTRA HEAVY DUTY, MODEL 3, SEAMLESS,
<br />HOLLOW STEEL CONSTRUCTION, 16 GAUGE MATERIAL, UNITIZED GRID
<br />INNER STRUCTURE.
<br />b. 1 �4" THICK DOOR.
<br />c. PROVIDE ATTACHED LABELS INDICATING CLASSIFIED RATING FOR LABELED
<br />OPENINGS.
<br />d. MAXIMUM ALLOWABLE UNDERCUT CLEARANCE SHALL BE IN ACCORDANCE
<br />WITH NFPA 80
<br />4. MANUFACTURED FRAME UNITS:
<br />a. PRESSED STEEL CONSTRUCTED FRAMES FOR DOORS, SIDELIGHTS, TRANSOMS,
<br />MULLIONS, BORROWED LIGHTS AND OTHER INDICATED OPENINGS.
<br />b. 16 GAUGE METAL FRAMES FOR EXTERIOR AND FIRE RATED OPENINGS: WELD,
<br />DRESS AND GRIND SMOOTH ALL CORNERS. AND OTHER CONNECTIONS.
<br />PROVIDE TEMPORARY SPREADERS DURING SHIPPING, HANDLING AND INSTALLATION.
<br />NOTE: LABELED METAL FRAMES FOR RATED DRYWALL ASSEMBLIES MAY BE OF
<br />KNOCK DOWN TYPE COMPLYING W/ANSI/NFPA 80 OR OTHER ACCEPTABLE
<br />AGENCY REQUIREMENTS.
<br />c. INTERIOR NON -FIRE -RATED APPLICATION: MAY BE KNOCK DOWN TYPE.
<br />5. FRAME ANCHORS:
<br />a. MASONRY- ADJUSTABLE FLAT, CORRUGATED OR PERFORATED 18 GAUGE
<br />T-SHAPED ANCHORS MINIMUM OF 2" WIDE x 18" LONG, HOT -DIPPED GALVANIZED.
<br />b. DRYWALL - MANUFACTURER'S STANDARD ADJUSTABLE STUD TYPE, 18 GAUGE,
<br />® 2'-0" MAXIMUM O.C.
<br />c. PROVIDE UL TYPE ANCHORS FOR FIRE RATED FRAMES.
<br />d. CEILING STRUTS: PROVIDE Y4" x 2" STEEL STRUTS SPOT WELDED TO
<br />JAMB FRAMES, EACH SIDE OF OPENING AND EXTEND STRUTS TO BUILDING
<br />STRUCTURE AND ANCHOR.
<br />DIVISION NO. 8 DOORS AND WINDOWS:
<br />008100 ALUMINUM DOORS AND FRAMES:
<br />A.- WORK INCLUDED
<br />1. FURNISH ALL ALUMINUM ADJUSTABLE DOOR FRAMES
<br />B.- QUALITY ASSURANCE
<br />1. ALL FRAMES SHALL BE MANUFACTURED BY A COMPANY HAVING AT
<br />LEAST FIVE YEARS EXPERIENCE AS AN ALUMINUM ADJUSTABLE FRAME
<br />MANUFACTURER.
<br />C. SUBMITTALS
<br />1. PROVIDE A SCHEDULE OF ALL ALUMINUM ADJUSTABLE FRAMES FOR
<br />APPROVAL INDICATING SIZE, MARK, LOCATION, SWING, CONSTRUCTION,
<br />WALL CONDITIONS, FIRE RATING AND HARDWARE SET.
<br />2. PROVIDE ELEVATION AND SECTION DETAILS.
<br />3. PROVIDE MANUFACTURER'S STANDARD FINISH SELECTIONS.
<br />D. HANDLING
<br />1. HANDLE ALL FRAMES WITH CARE IN A MANNER TO AVOID DAMAGE TO
<br />THE PRODUCT.
<br />PART II - PRODUCTS
<br />A. DESIGN
<br />1. FRAMES SHALL BE DESIGNED TO BE ADJUSTABLE FOR WALL THICKNESS
<br />IN 1" (25.4 MM) INCREMENTS FOR WALLS FROM 2 lh- THRU 8.5" (63.5
<br />MM TO 219 MM) THICK.
<br />2. FRAMES SHALL BE DESIGNED TO INSTALL INTO A ROUGH OPENING OVER
<br />FINISHED WALLS.
<br />3. FRAMES SHALL BE DESIGNED TO HAVE ALL INSTALLATION FASTENERS
<br />CONCEALED UPON FINAL ASSEMBLY.
<br />4. FRAMES SHALL BE DESIGNED TO BE REMOVABLE AND RELOCATABLE.
<br />B. MATERIAL
<br />1. FRAMES SHALL BE MANUFACTURED FROM ALUMINUM EXTRUSIONS;
<br />6063-T5 ALLOY. ALL EXPOSED FRAME PARTS SHALL BE PRE -FINISHED.
<br />EXTRUSIONS MAY VARY
<br />IN THICKNESS EXCEPT THAT STRUCTURAL PORTIONS SHALL BE AT LEAST 3/16-
<br />(4.8 MM) THICK AT ATTACHMENT OF HINGE SCREWS. TYPICAL WALL
<br />THICKNESS OF DOOR SIDE SHALL BE MINIMUM .080- (2 MM). TYPICAL
<br />WALL THICKNESS OF ADJUSTER TRIM SIDE SHALL BE MINIMUM .062" (1.6
<br />MM). CASING OR FACE SHALL BE 1-1/2' (38.1 MM).
<br />C. FINISH
<br />1. ALL FRAMES SHALL BE FACTORY PRE -FINISHED IN CLEAR SATIN ANODIZED
<br />(OR IN HARDCOAT DURANODIC ANODIZED, MEDIUM BRONZE COLOR; IN
<br />ELECTROSTATICALLY APPLIED BAKED ENAMEL, MEDIUM BRONZE COLOR, OR
<br />FOR OTHER COLORS CONTACT FACTORY.)
<br />D. CONSTRUCTION
<br />1. FRAMES SHALL BE ASSEMBLED IN TWO SECTIONS, DOOR SIDE (MASTER
<br />SECTION) AND ADJUSTER SIDE (TRIM SECTION), WITH SNAP -ON TYPE STOP
<br />COVER PLATES. ASSEMBLY OF EACH SECTION SHALL BE WITH MITERED
<br />CORNERS ATTACHED WITH ALUMINUM CORNER GUSSETS WELDED INTO
<br />POSITION AT THE FACE, RIBBED .57" (14.5 MM) ALUMINUM DRIVE FIT
<br />CORNER KEYS AT THE RABBET AND .062" (1.6 MM) RIVETED CORNER
<br />ANGLES AT THE INSIDE CONCEALED LEGS. WELDING OF ALUMINUM FACES
<br />SHALL NOT BE ACCEPTABLE.
<br />2. INTERNAL HARDWARE REINFORCEMENT FOR HINGES AND LOCK STRIKE
<br />SHALL BE ALUMINUM EXTRUSIONS, MILL FINISH, STAKED IN POSITION.
<br />HINGE AND LOCK STRIKE REINFORCEMENTS SHALL BE ADJUSTABLE BY AT
<br />LEAST 1 /8° (3.2 MM). HEAD FACE SHALL BE REINFORCED WITH 1 /8-
<br />(3.18 MM) ALUMINUM PLATE 12- (304.8 MM) LONG FOR CLOSER ARMS
<br />WHERE REQUIRED. HEAD AND JAMB INTERNAL ALIGNMENT PARTS SHALL
<br />BE ALUMINUM EXTRUSIONS, MILL FINISH, STAKED IN POSITION.
<br />3. HARDWARE MORTISE LIP EXTRUSION SHALL BE .134- (3.4 MM) HIGH,
<br />NOTCHED AT LOCATION OF HINGES, STRIKES AND OTHER MORTISE
<br />HARDWARE. RABBET SHALL BE PUNCHED WITH SLOTTED HOLES FOR
<br />ADJUSTABILITY OF HINGES AND LOCK STRIKES.
<br />4. FRAME SHALL BE PROVIDED WITH A VINYL BULB GASKET AROUND THE
<br />ENTIRE PERIMETER OF THE DOOR OPENING, STAKED INTO POSITION AT
<br />CONCEALED LOCATIONS.
<br />5. DOOR SIDE AND ADJUSTER SIDE SHALL BE ASSEMBLED AT THE FACTORY
<br />FORMING A COMPLETE FRAME.
<br />E. HARDWARE PREPARATIONS
<br />1. FRAMES SHALL BE REINFORCED, DRILLED AND TAPPED FOR HINGES AND
<br />LOCK STRIKE. REINFORCE ONLY FOR SURFACE MOUNTED HARDWARE. HOLES
<br />FOR EXTENSION FLUSH BOLTS SHALL BE DRILLED IN THE FIELD BY INSTALLER
<br />AFTER INSTALLATION OF DOORS AND FLUSH BOLT.
<br />2. HARDWARE ITEMS ATTACHING TO THE SNAP -ON STOP CAPS MUST BE
<br />ATTACHED THRU CLEARANCE HOLES IN THE CAP (FIELD DRILLED BY
<br />INSTALLER) WITH SCREWS OF SUFFICIENT LENGTH TO ATTACH DIRECTLY TO THE
<br />BACK OF THE DOOR SECTION OF THE FRAMES. NONSTANDARD SCREWS MAY
<br />BE REQUIRED BY FINISH HARDWARE SUPPLIER OR INSTALLER.
<br />3. FRAME IS NOT DESIGNED FOR USE WITH TOP/BOTTOM PIVOT HINGES OR
<br />DOUBLE ACTING DOORS.
<br />F. WALL PREPARATIONS
<br />1. PROVIDE ROUGH OPENINGS IN FINISHED WALLS FOR INSTALLATION OF
<br />DOOR FRAME. ROUGH OPENING SIZES AND DETAILS TO BE PROVIDED BY
<br />THE FRAME MANUFACTURER.
<br />2. WALL OPENINGS SHALL BE PROVIDED WITH WOOD STUDS OR MINIMUM
<br />16 GAGE STEEL STUDS AT THE JAMBS. LIGHT GAGE STEEL STUDS MY BE
<br />USED AT THE HEAD.
<br />3. MASONRY WALLS SHALL BE PROVIDED WITH A 2 X 4 OR SIMILAR WOOD
<br />STUD FINISHED WITH GYPSUM WALLBOARD BOTH SIDES FOR ATTACHMENT
<br />OF THE FRAME.
<br />G. FRAME INSTALLATION
<br />1. INSTALL FRAMES IN STRICT ACCORDANCE WITH MANUFACTURER'S
<br />INSTALLATION INSTRUCTIONS.
<br />2. MANUFACTURER TO PROVIDE ALL NECESSARY INSTALLATION MATERIALS
<br />FOR INSTALLATION IN WOOD OR STEEL STUD WALLS. PROVIDE ALL SCREWS AS
<br />REQUIRED FOR A COMPLETE INSTALLATION.
<br />3. ALL INSTALLATION MATERIALS ARE TO BE FULLY CONCEALED UPON
<br />COMPLETION OF THE INSTALLATION.
<br />H. FIRE RATING
<br />1. ALL FRAMES SHALL BE PROVIDED WITH FIRE RATING OF 20 MINUTES OR
<br />3/4 HR 'C' WHERE LISTED ON THE DOOR SCHEDULE. ATTACH LABELS FROM
<br />AN APPROVED TESTING LABORATORY FOR ALL FRAMES THAT COMPLY WITH
<br />THE MANUFACTURER'S PROCEDURE AND NFPA 80. OPENINGS THAT DO
<br />NOT COMPLY FULLY WITH THE REQUIREMENTS OF AN ALUMINUM FIRE RATED
<br />FRAME SHALL BE SO LISTED ON THE SHOP DRAWING SCHEDULES AND SHALL
<br />BE FURNISHED WITH A CERTIFICATION LABEL ATTACHED.
<br />PART III - EXECUTION
<br />A. STORAGE
<br />1. STORE FRAMES IN UNOPENED CARTONS OFF THE FLOOR.
<br />B. INSTALLATION & INSPECTION
<br />1. INSTALL FRAMES INTO ROUGH OPENINGS THAT COMPLY WITH
<br />MANUFACTURER'S RECOMMENDATIONS. IF INSPECTION REVEALS
<br />DEFICIENCIES IN THE OPENING , CORRECT BEFORE INSTALLING FRAMES.
<br />2. INSTALL FRAME IN STRICT ACCORDANCE WITH MANUFACTURER'S
<br />INSTALLATION INSTRUCTIONS.
<br />3. CARPENTER OR FURNITURE CLAMPS SHALL BE USED TO SECURE THE
<br />FRAME RETURN TIGHT AGAINST THE WALL DURING INSTALLATION.
<br />C. ADJUSTMENTS & CLEANING
<br />1. ADJUST FRAMES TO PLUMB AND SQUARE CONDITION. SNAP -ON JAMB
<br />STOP COVER PLATES ARE TO BE INSTALLED AFTER ALL FINAL ADJUSTMENTS
<br />HAVE BEEN MADE.
<br />2. ADJUST ALL FIRE LABELED FRAMES TO TOLERANCES REQUIRED BY NFPA
<br />80, SECTION 2-5.4.
<br />3. CLEAN ALUMINUM FRAMES WITH A MILD COMMERCIAL CLEANER OR
<br />WITH MINERAL SPIRITS. DRY WIPE WITH A SOFT CLOTH THE REMOVE ALL
<br />CLEANE
<br />DIVISION NO. 8 DOORS AND WINDOWS:
<br />008100 CEILING ACCESS DOOR:
<br />A. MATERIALS:
<br />1. CONSTRUCTION
<br />a. METALS: GALVANIZED STEEL
<br />FRAME - 16GA MIN.
<br />PANEL - 18 GA MIN.
<br />LINER - 22 GA MIN.
<br />b. INSULATION - 1-1/2" HIGH TEMP INSULATION
<br />c. NON COMBUSTIBILITY CLASSIFICATION
<br />CAN/ULC S114, ASTM E136, CAN/ULC S102, ASTM E84
<br />UL723, FLAME SPREAD = 0, SMOKE DEVELOPMENT = 0
<br />2. PRIMER COAT:
<br />a. PRIME COAT OVER STEEL - ONE COAT MFR.'S STANDARD
<br />ELECTROCHEMICALLY APPLIED RUST INHIBITIVE PRIME COAT.
<br />3. MANUFACTURED DOOR AND FRAME UNITS:
<br />a. INSULATED, SURFACE MOUNTED, UPWARD OPENING, FIRE
<br />RATED, CEILING ACCESS
<br />b. PROVIDE WARNOCK HERSEY LABEL INDICATING CLASSIFIED
<br />RATING FOR LABELED
<br />OPENINGS.
<br />c. CONCEALED CONTINUOUS PIANO HINGE.
<br />d. STANDARD FACTORY LATCH FOR FIRE RATED ASSEMBLY
<br />e. MAXAM METAL PRODUCTS: VAN -MET MODEL FAI-150
<br />2 HR. FIRE RATED OR APPROVED EQUAL.
<br />DIVISION NO. 8 DOORS AND WINDOWS:
<br />008210 WOOD DOORS:
<br />A. MATERIALS:
<br />1. INDUSTRY STANDARDS:
<br />a. AWI: ARCHITECTURAL WOODWORK QUALITY STANDARDS, GUIDE SPECS.,
<br />QUALITY CERTIFICATION PROGRAM, CURRENT EDITION.
<br />b. NWWDA:; INDUSTRY STANDARD I.S. SERIES.
<br />2. WARRANTY: DOORS: LIFE OF THE INSTALLATION AGAINST DELAMINATION OR
<br />WARP. PROVIDE FOR FINISHED REPLACEMENT; INCLUDE PROJECT SITE
<br />LABOR AND MATERIALS.
<br />3. ACCEPTABLE MANUFACTURERS:
<br />a. MARSHFIELD DOORSYSTEMS, INC.
<br />B. MANUFACTURED UNITS:
<br />1. TYPE: NWWDA L.S. 1-87, GRADE II, AND
<br />AWI SECTION 1300, CUSTOM GRADE, SOLID CORE.
<br />2. GENERAL: FIVE PLY CONST., 28-32 DENSITY
<br />PARTICLE BOARD CORE, ANSI A208.1, GRADE
<br />1-L-1, AWI SECTION 1300 PC-5.
<br />3. EDGE BANDS & MOULDINGS: MATCH FACE VENEER.
<br />4. ADHESIVE: COMMERCIAL STANDARD CS 171, TYPE II,
<br />WATER RESISTANT.
<br />5. FACTORY FABRICATED CUTOUTS IN LABELED DOORS ONLY -
<br />(NOTE: FIELD FABRICATED OPENINGS ARE PROHIBITED).
<br />6. LABEL: UL OR WHI RATED LABELS ATTACHED ON RATED DOORS.
<br />7. FINISH: FACTORY
<br />8. GLAZING AS SCHEDULED.
<br />9. DOOR SKINS:
<br />a. AWI SECTION 200 S 8, GRADE II. (STAIN GRADE).
<br />b. FACE VENEER:
<br />SPECIES AND CUT: ROTARY BIRCH.
<br />VENEERS: BOOK MATCHED
<br />THICKNESS: Ym"
<br />CROSSBAND: Yto", THICKNESS.
<br />c. WOOD BEADS & APPLIED MOULDINGS: AWI GRADE.
<br />10. GLAZING: Y4" TEMPERED SAFETY GLASS MEETING ANSI Z97.1-1984
<br />PROVIDE GLAZING BEADS WITH MITERED CORNERS, MATCH DOOR
<br />SPECIES. PROVIDE NFPA 80 TRIM ® RATED DOORS.
<br />GENERAL NOTE:
<br />TENANT IMPROVEMENTS WILL
<br />REQUIRE A VARYING AMOUNT OF
<br />IMPROVEMENTS UNDER THIS
<br />PROJECT SCOPE OF WORK.
<br />THEREFORE, SOME OF THESE
<br />SPECIFICATIONS MAY ONLY RELATE
<br />TO A SMALL PORTION OF THE
<br />WORK, OR IN SOME CASES NONE
<br />AT ALL.
<br />cz
<br />(1)
<br />C
<br />L
<br />o
<br />�
<br />4-
<br />L
<br />•
<br />c
<br />a)
<br />'a
<br />c
<br />z
<br />0
<br />0
<br />`c
<br />o
<br />U
<br />0)
<br />L)
<br />U
<br />LCD
<br />O
<br />o
<br />c c
<br />x x
<br />+j
<br />o
<br />(2)
<br />U
<br />•ri
<br />L.
<br />c
<br />a_
<br />L.
<br />C
<br />L
<br />+_j
<br />m
<br />o
<br />C
<br />e
<br />4-
<br />o
<br />• 1
<br />a)
<br />0
<br />a
<br />-0
<br />11' ,, u1.. slte'6had heH,•. ors r,alip{ - # 6
<br />orlglnal dmr ln,, These. sccles are hereby
<br />changed ay the rcdo of tre av 11 sheet
<br />rnl not rh
<br />U
<br />U)
<br />U
<br />Q
<br />("M
<br />U
<br />co
<br />�
<br />0
<br />o
<br />M
<br />Q
<br />o_
<br />I
<br />H
<br />1
<br />O
<br />O
<br />�
<br />N
<br />O
<br />m
<br />�
<br />t-
<br />z
<br />Q
<br />x
<br />C J
<br />H
<br />H
<br />c�
<br />c7
<br />0
<br />o
<br />Q
<br />O
<br />_(D
<br />H
<br />-1
<br />1`
<br />X
<br />N
<br />m
<br />Q
<br />LLL
<br />z
<br />0
<br />Q
<br />U
<br />O
<br />_ 1
<br />W
<br />,-
<br />LO
<br />.
<br />CM
<br />U
<br />o
<br />M
<br />VJ
<br />z_
<br />-
<br />~
<br />m
<br />Q
<br />z
<br />J
<br />W
<br />J
<br />J
<br />CL
<br />W
<br />=
<br />N
<br />Z
<br />W
<br />N
<br />DRAWN BY:
<br />LJ/CH
<br />DATE: 03/12/13
<br />PROJECT NO.1230
<br />REV.
<br />R_
<br />R_
<br />REVISIONS
<br />Sheet No.
<br />T-4
<br />
|