Laserfiche WebLink
N <br />Z <br />0 <br />ry <br />T) <br />N <br />0-) <br />O <br />N <br />DIVISION NO. 7 THERMAL AND MOISTURE PROTECTION: <br />007210 BUILDING INSULATION <br />A. MATERIALS: <br />1. BATT INSULATION: FIBERGLASS BATTS, 16" & 24" WIDTHS. <br />a. KRAFT FACED, ASTM C665-86, TYPE II, CLASS C, <br />PERM RATING OF1.0 MINIMUM. <br />b. "R" VALUE FOR THERMAL RESISTANCE: <br />(1) EXTERIOR WALL - FULL HEIGHT R-19, <br />(2) CEILING - R-30 PLACED IN PLANE OF BOTTOM CHORD <br />OF TRUSSED RAFTERS ROOF FRAMING. <br />(3) ROOF DECK - R-19. UNLESS OTHERWISE INDICATED. <br />2. OPEN CELL SPRAY FOAM INSULATION <br />a. OPEN CELL FOAM, R-VALUE TESTED WITH ASTM C-518 <br />b. "R" VALUE FOR THERMAL RESISTANCE: <br />NOMINAL R-VALUE OF 6 PER INCH THICKNESS. <br />c. APPLY A MINIMUM OF 5 INCHES OF THICKNESS TO BOTTOM <br />SIDE OF ROOF DECK, R-30 REQUIRED. <br />d. INSTALL REQUIRED IGNITION BARRIER AS RECOMMENDED BY <br />MANUFACTURER. ICYNENE BLAZLOK 1B4 OR EQUAL. <br />e. RECOMMENDED MANUFACTURERS: LAPOLLA: FOAM-LOK, ICYNENE, <br />NCFI POLYURETHANES: INSULSTAR, OR EQUAL. <br />3. SOUND BATT INSULATION: UNFACED GLASS FIBER - ASTM C 665 <br />TYPE 1 & ASTM E 136. <br />a. SIZE: R-VALUE 11.0 WHEN TESTED WITH ASTM C 518. <br />b. VAPOR RETARDER PERM RATING: 1.0 WHEN TESTED WITH <br />ASTM C 518. <br />c. SURFACE BURNING CHARACTERISTICS: <br />(1) UNFACED INSULATION <br />(2) MAXIMUM FLAME SPREAD: 10 <br />(3) MAXIMUM SMOKE DEVELOPED: 10 <br />(4) WHEN TESTED IN ACCORDANCE WITH ASTM E 84. <br />d. DIMENSIONAL STABILITY: LINEAR SHRINKAGE LESS THAN 0.1 %. <br />4. RIGID EXTRUDED POLYSTYRENE INSULATION (WEPS) SHEATHING. <br />AMOCO FOAM PRODUCTS, INC. - AMOFOAM-SL; DOW CHEMICAL USA - <br />STYROFOAM SCORE BOARD. <br />5. PERIMETER INSULATION: RIGID EXTRUDED POLYSTYRENE PERIMETER <br />INSULATION (XEPS): (IF REQUIRED BY APPLICABLE CODE. <br />PRODUCTS: AMOCO FOAM PRODUCTS, INC. - AMOFOAM-CM <br />DOW CHEMICAL USA - STYROFOAM SQUARE EDGE. <br />6. KRAFT BACK INSULATION SHALL NOT BE EXPOSED UNDER ANY CIRCUMSTANCE. <br />ALL KRAFT BACK INSULATION IN WALLS ABOVE CEILING SHALL BE PROTECTED WITH <br />GYPSUM BOARD SHEATHING. <br />1. CHARACTERISTICS: <br />a. EXTRUDED MATERIALS, CLOSED CELL POLYSTYRENE BOARD, <br />ASTM C578-87a, TYPE IV. <br />b. THICKNESS 1 1 /2" <br />c. DENSITY: 2.0 PCF, MINIMUM. <br />d. "K" VALUE ® 75' F: 0.20 <br />e. COMPRESSIVE STRENGTH: 20 MINIMUM 1.1 PER -IN, TESTED PER <br />ASTM D 1621-73. <br />f. WATER VAPOR TRANSMISSION: MAXIMUM 1.1 PERM -IN, ASTM E96-80, <br />PROCEDURE B. <br />g. SIZE: 2'-0" x 8'-0". <br />h. EDGES: SQUARE. <br />i. EACH BOARD MARKED TO INDICATE CODE COMPLIANCE. <br />DIVISION NO. 7 THERMAL AND MOISTURE PROTECTION: <br />007270 FIRESTOPPING <br />A. MATERIALS: <br />1. PENETRATIONS, SMOKE AND FIRE, NOT REQUIRING INTUMESCENT QUALITIES. <br />FOAMING TYPE: DOW CORNING CO. - RTV 2001; GENERAL ELECTRIC <br />CO. - PENSIL RTV851. <br />2. SEALANTS: DOW CORNING CO. FIRE STOP NO. 2000; FLAME STOP, INC. FLAME <br />STOP V CAULKING/TROWELLABLE.; GENERAL ELECTRIC CO. - RTV 7403; <br />METALINES, INC. METALCAULK SERIES; NELSON ELECTRIC NELSON CMP; <br />STANDARD OIL ENGINEERED MATERIALS - FIBERFRAX SERIES; 3M CO/ELECTRICAL <br />PRODUCTS DIVISION - INTERAM FIREDAM 150 CAULK. <br />3. STRIP OR WRAP: DOW CORNING CO. - FIRE STOP 2002 INTUMESCENT WRAP STR.; <br />3M CO./ELECTRICAL PRODUCTS DIVISION - FIRE BARRIER. <br />4. PUTTY: FLAME STOP, INC. FLAMES STOP V PUTTY; NELSON ELECTRIC - NELSON FSP, <br />FLAMESEAL.; 3M CO/ELECTRICAL PRODUCTS DIVISION - FIRE BARRIER CAULK 3303. <br />5. TAPE: 3M CO/ELECTRICAL PRODUCTS DIVISION - INERAM T-49. <br />6. SAFING INSULATION: FIBREX - FBX SAFING INSULATION; MANVILLE CORP. - PYRO-FIBER <br />SAFING INSULATION; USG ACOUSTICAL PRODUCTS CO. - THERMAFIBER SAFING INSULATION. <br />a. CHARACTERISTICS: BLOWN, BONDED, COMPRESSIBLE, SEMI -RIGID, MINERAL FIBER <br />BLANKET PER ASTM C612-83, CLASS 3. <br />b. DENSITY: SIX (6) PCF, NOMINAL <br />c. COMBUSTIBILITY: NON-COMBUSTIBLE PER ASTM E136-82. <br />d. FLAME SPREAD: 15 PER ASTM E84-87. <br />e. ACCESSORIES: PROVIDE MFR.'S STANDARD IMPALING CLIPS. <br />B. PENETRATIONS, SMOKE AND FIRE, REQUIREMENT INTUMESCENT QUALITIES, SUCH AS PVC PIPE <br />OR OTHER DISSOLVING MATERIALS. <br />1. SEALANTS: FLAMES STOP, INC. -FLAMES STOP V CALKING/TROWELLABLE; <br />STOP V CAULKING/TROWELLABLE.; ETALINES, INC. METALCAULK SERIES; 3M CO/ELECTRICAL <br />PRODUCTS DIVISION - FIRE BARRIER CAULK CP-25. <br />2. STRIP OR WRAP: DOW CORNING CO. - FIRE STOP 2002 INTUMESCENT WRAP STRIP; <br />3M CO./ELECTRICAL PRODUCTS DIVISION - FIRE BARRIER WRAP/STRIP FS-195. <br />3. PUTTY: FLAME STOP, INC. - FLAMES. STOP V PUTTY; NELSON ELECTRIC - NELSON <br />FLAMESEAL.; 3M CO/ELECTRICAL PRODUCTS DIVISION - FIRE BARRIER CAULK 303. <br />4. TAPE: 3M CO/ELECTRICAL PRODUCTS DIVISION - INERAM T-49. <br />5. SHEET: 3M CO/ELECTRICAL PRODUCTS DIVISION - COMPOSITE SHEET CS-195. <br />6. KITS FOR ROUND & RECTANGULAR PENETRATIONS: 3M CO./ELECTRICAL PRODUCTS DIVISION <br />7902 AND 7904 SERIES. <br />5. SAFING INSULATION: FIBREX - FBX SAFING INSULATION; MANVILLE CORP. - PYRO-FIBER <br />SAFING INSULATION; USG ACOUSTICAL PRODUCTS CO. - THERMAFIBER SAFING INSULATION <br />a. CHARACTERISTICS: BLOWN, BONDED, COMPRESSIBLE, SEMI -RIGID, MINERAL FIBER <br />BLANKET PER ASTM C612-83, CLASS 3. <br />b. DENSITY: SIX (6) PCF, NOMINAL <br />c. COMBUSTIBILITY: NON-COMBUSTIBLE PER ASTM E136-82. <br />d. FLAME SPREAD: 15 PER ASTM E84-87. <br />e. ACCESSORIES: PROVIDE MFR.'S STANDARD IMPALING CLIPS. <br />6. PENETRATIONS, SMOKE AND FIRE, REQUIREMENT INTUMESCENT QUALITIES, SUCH AS <br />PVC PIPE OR OTHER DISSOLVING MATERIALS. <br />DIVISION NO. 7 THERMAL AND MOISTURE PROTECTION: <br />007310 COMPOSITION SHINGLES (THIS SECTION APPLIES ONLY WHERE SCHEDULED OR <br />APPLICABLE UNDER THE MBBI WORK REQUIREMENTS) <br />A. MATERIALS: <br />1. LAMINATED FIBERGLASS BASE SHINGLES: <br />a. CERTAINTEED CORP. - HALMARK SHINGLES <br />b. GAF CORP. TIMBERLINE. <br />c. TANKO - HERITAGE M30. <br />2. CHARACTERISTICS: <br />a. FIBERGLASS FELT SHINGLES PER ASTM D3018-82, TYPE 1. <br />b. MEETS UL CLASS A FOR FIRE RESISTANCE. <br />c. MEETS UL STANDARDS FOR WIND RESISTANCE. <br />d. PROVIDE SHINGLES W/ SELF SEALING STRIPS. <br />e. PROVIDE MANUFACTURER'S MIN. 20 YEAR WITH NO DOLLAR LIMIT. <br />f. COLOR: AS SELECTED BY ARCHITECT FROM MFR.'S STANDARD COLORS. <br />3. -ACCESSORIES: <br />a. ROOFING FELTS, UNDERLAYMENT: MEETS ASTM D226-87, TYPE 1, 30 <br />LBS PER SQUARE, ASPHALT SATURATED ORGANIC FELT, 3'-0" WIDE, <br />UNPERFORATED. <br />b. NAILS: HOT -DIPPED GALVANIZED, 10 )� GAUGE RINGED SHANK; LENGTH <br />TO PENETRATE ROOF DECK, MINIMUM -Y4". <br />c. STAPLES: ZINC COATED, 16 GAUGE STAPLES, 1" NOMINAL CROWN. <br />d. RIDGE SHINGLES: MATCH COLOR OF EXISTING SHINGLES. <br />DIVISION NO. 7 THERMAL AND MOISTURE PROTECTION: <br />007460 VINYL SIDING (THIS SECTION APPLIES ONLY WHERE SCHEDULED <br />OR APPLICABLE UNDER THE MBBI WORK REQUIREMENTS.) <br />A. MATERIALS: <br />1. VINYL SIDING: ALCOA LIBERTY - DOUBLE 4" - ALCOA BUILDING PRODUCTS; <br />DOUBLE IV - ALSIDE; FOREST RIDGE - DOUBLE 4" - GEORGIA PACIFIC. <br />2. SOLID VIYL SIDING: EXTRUDED POLY VINYL CHLORIDE (PVC) COMPOUND PER <br />ASTM D3769, "STANDARD SPECIFICATION FOR PVC SIDING" <br />3. COLOR: AS SELECTED BY ARCHITECT FROM MFR.'S STANDARD COLORS. <br />4. TRIM & ACCESSORIES: SAME MFR. AS VINYL SIDING, COLOR TO MATCH VINYL <br />SIDING AND SOFFIT. <br />B. VINYL SOFFIT: <br />1. MANUFACTURERS: <br />a. PRO -TECH PLUS - ALCOA BUILDING PRODUCTS. <br />b. SERIES E SMOOTH PREMIUM - ALSIDE, INC. <br />c. T/4 CENTER VENT SOFFIT - GEORGIA PACIFIC CORP. <br />d. NOTE: PROVIDE SUPERSPAN HEAVY GAUGE PREMIUM SOFFIT <br />® ENTRANCE CANOPY, ALSIDE, INC. OR EQUAL. <br />2. SOLID AND VENTILATED SOFFIT: EXTRUDED POLY CHLORIDE (PVC) <br />COMPOUND PER ASTM D 3769 " STANDARD SPECIFICATION FOR <br />PVC SIDING. <br />3. COLOR AS SELECTED BY ARCHITECT FROM MFR.'S STANDARD COLORS. <br />C. ALUMINUM FASCIA: <br />1. ALCOA BUILDING PRODUCTS - F2C6. <br />2. -ALSIDE, INC. - 6" SMOOTH. <br />3. GEORGIA PACIFIC - 6" SMOOTH. <br />DIVISION NO. 7 THERMAL AND MOISTURE PROTECTION: <br />007600 FLASHING AND SHEET METAL: <br />(THIS SECTION APPLIES ONLY WHERE SCHEDULED <br />OR APPLICABLE UNDER THE MBBI WORK REQUIREMENTS) <br />A. MATERIALS: <br />1. GALVANIZED SHEET METAL 24 GAUGE PAINT GRIP, UNCOATED THICKNESS <br />COMMERCIAL GRADE PAINT GRIP GALVANIZED STEEL, - ASTM A525-87, <br />COATING DESIGNATION G140, ZINC COATING NOT LESS THAN <br />1.2 OZ ZINC. PSF.TAINTEED CORP. - HALMARK SHINGLES <br />2. • GUTTERS & DOWNSPOUTS -ALUM OGEE-0.019" GAUGE MINIMUM. <br />DOWNSPOUTS IN FRONT TO EXTEND & SPILL -OUT ® CURB & GUTTER. <br />DOWNSPOUTS - OTHER AREAS - SPILL -OUT ® GRADE ON PRECAST <br />CONCRETE SPLASHBLOCKS. <br />3. FLEXIBLE FLASHING - <br />a. ABOVE GRADE - 5 OZ COPPER LAMINATED FLEXIBLE THRU-WALL <br />FLASHING - POLYTITE, SANDELL OR YORK. <br />b. BELOW GRADE - 0.056 MIL, 6.2 OZ PSF POLLYVINYL CHLORIDE <br />MEMBRANE FLASHING - YORK - WASCOSEAL 60, POLYTITE. <br />4. MORTAR DEFLECTION DEVICE FOR CAVITY WALLS - MORTAR MAZE, <br />MORTAR NET. <br />IVISION NO. 7 THERMAL AND MOISTURE PROTECTION: <br />007920 SEALANT <br />AND CAULKING: <br />A. MATERIALS: <br />1. <br />SILICONE SEALANTS <br />a. CHEMREX, INC. - OMNISEAL <br />b. DOW CORNING CORP NO. 790. <br />c. GE SILICONES - SILGLAZE <br />d. PECORA CORP. - NO. 864 <br />e. TREMCO INC. - SPECTREM 1 <br />2. <br />ACRYLIC LATEX CAULKING COMPOUND: <br />a. BOSIK CONST. PROD. DIV. - CHEM CALK 600 <br />b. CHEMREX - SONOLAC <br />c. W R MEADOWS, INC. - EASAPLY <br />d. PECORA CORP. AC-20 <br />e. TREMCO, INC. ACRYLIC LATEX CAULK <br />3. <br />BUTYL CAULK - <br />a. PECORA CORP - BC-158 <br />b. TREMCO, INC. BUTYL SEALANT <br />DIVISION NO. 8 DOORS AND WINDOWS: <br />008100 HOLLOW METAL DOORS AND FRAMES: <br />A. MATERIALS: <br />1. METALS <br />a. ASTM A366-85, COLD ROLLED STEEL SHEETS. <br />b. EXTERIOR DOORS AND FRAMES - ZINC COATED PER <br />ASTM A525-87 <br />c. WIPE COAT GALVANIZED STEEL COMPONENTS ARE PROHIBITED. <br />2. PRIMER COAT: <br />a. PRIME COAT OVER STEEL - ONE COAT MFR.'S STANDARD <br />BAKED -ON ENAMEL RUST -INHIBITIVE PRIMER, 0.7 DFT MIN. THICKNESS. <br />b. ONE COAT MFR'S STANDARD BAKED ON ENAMEL RUST -INHIBITIVE <br />PRIMER, AFTER PAINT ADHESION TREATMENT, 1.0 MIL DFT. <br />3. MANUFACTURED DOOR UNITS: <br />a. DOORS - EXTERIOR UNITS <br />INSULATED TYPE, GRADE III, EXTRA HEAVY DUTY, MODEL 3, SEAMLESS, <br />HOLLOW STEEL CONSTRUCTION, 16 GAUGE MATERIAL, UNITIZED GRID <br />INNER STRUCTURE. <br />b. 1 �4" THICK DOOR. <br />c. PROVIDE ATTACHED LABELS INDICATING CLASSIFIED RATING FOR LABELED <br />OPENINGS. <br />d. MAXIMUM ALLOWABLE UNDERCUT CLEARANCE SHALL BE IN ACCORDANCE <br />WITH NFPA 80 <br />4. MANUFACTURED FRAME UNITS: <br />a. PRESSED STEEL CONSTRUCTED FRAMES FOR DOORS, SIDELIGHTS, TRANSOMS, <br />MULLIONS, BORROWED LIGHTS AND OTHER INDICATED OPENINGS. <br />b. 16 GAUGE METAL FRAMES FOR EXTERIOR AND FIRE RATED OPENINGS: WELD, <br />DRESS AND GRIND SMOOTH ALL CORNERS. AND OTHER CONNECTIONS. <br />PROVIDE TEMPORARY SPREADERS DURING SHIPPING, HANDLING AND INSTALLATION. <br />NOTE: LABELED METAL FRAMES FOR RATED DRYWALL ASSEMBLIES MAY BE OF <br />KNOCK DOWN TYPE COMPLYING W/ANSI/NFPA 80 OR OTHER ACCEPTABLE <br />AGENCY REQUIREMENTS. <br />c. INTERIOR NON -FIRE -RATED APPLICATION: MAY BE KNOCK DOWN TYPE. <br />5. FRAME ANCHORS: <br />a. MASONRY- ADJUSTABLE FLAT, CORRUGATED OR PERFORATED 18 GAUGE <br />T-SHAPED ANCHORS MINIMUM OF 2" WIDE x 18" LONG, HOT -DIPPED GALVANIZED. <br />b. DRYWALL - MANUFACTURER'S STANDARD ADJUSTABLE STUD TYPE, 18 GAUGE, <br />® 2'-0" MAXIMUM O.C. <br />c. PROVIDE UL TYPE ANCHORS FOR FIRE RATED FRAMES. <br />d. CEILING STRUTS: PROVIDE Y4" x 2" STEEL STRUTS SPOT WELDED TO <br />JAMB FRAMES, EACH SIDE OF OPENING AND EXTEND STRUTS TO BUILDING <br />STRUCTURE AND ANCHOR. <br />DIVISION NO. 8 DOORS AND WINDOWS: <br />008100 ALUMINUM DOORS AND FRAMES: <br />A.- WORK INCLUDED <br />1. FURNISH ALL ALUMINUM ADJUSTABLE DOOR FRAMES <br />B.- QUALITY ASSURANCE <br />1. ALL FRAMES SHALL BE MANUFACTURED BY A COMPANY HAVING AT <br />LEAST FIVE YEARS EXPERIENCE AS AN ALUMINUM ADJUSTABLE FRAME <br />MANUFACTURER. <br />C. SUBMITTALS <br />1. PROVIDE A SCHEDULE OF ALL ALUMINUM ADJUSTABLE FRAMES FOR <br />APPROVAL INDICATING SIZE, MARK, LOCATION, SWING, CONSTRUCTION, <br />WALL CONDITIONS, FIRE RATING AND HARDWARE SET. <br />2. PROVIDE ELEVATION AND SECTION DETAILS. <br />3. PROVIDE MANUFACTURER'S STANDARD FINISH SELECTIONS. <br />D. HANDLING <br />1. HANDLE ALL FRAMES WITH CARE IN A MANNER TO AVOID DAMAGE TO <br />THE PRODUCT. <br />PART II - PRODUCTS <br />A. DESIGN <br />1. FRAMES SHALL BE DESIGNED TO BE ADJUSTABLE FOR WALL THICKNESS <br />IN 1" (25.4 MM) INCREMENTS FOR WALLS FROM 2 lh- THRU 8.5" (63.5 <br />MM TO 219 MM) THICK. <br />2. FRAMES SHALL BE DESIGNED TO INSTALL INTO A ROUGH OPENING OVER <br />FINISHED WALLS. <br />3. FRAMES SHALL BE DESIGNED TO HAVE ALL INSTALLATION FASTENERS <br />CONCEALED UPON FINAL ASSEMBLY. <br />4. FRAMES SHALL BE DESIGNED TO BE REMOVABLE AND RELOCATABLE. <br />B. MATERIAL <br />1. FRAMES SHALL BE MANUFACTURED FROM ALUMINUM EXTRUSIONS; <br />6063-T5 ALLOY. ALL EXPOSED FRAME PARTS SHALL BE PRE -FINISHED. <br />EXTRUSIONS MAY VARY <br />IN THICKNESS EXCEPT THAT STRUCTURAL PORTIONS SHALL BE AT LEAST 3/16- <br />(4.8 MM) THICK AT ATTACHMENT OF HINGE SCREWS. TYPICAL WALL <br />THICKNESS OF DOOR SIDE SHALL BE MINIMUM .080- (2 MM). TYPICAL <br />WALL THICKNESS OF ADJUSTER TRIM SIDE SHALL BE MINIMUM .062" (1.6 <br />MM). CASING OR FACE SHALL BE 1-1/2' (38.1 MM). <br />C. FINISH <br />1. ALL FRAMES SHALL BE FACTORY PRE -FINISHED IN CLEAR SATIN ANODIZED <br />(OR IN HARDCOAT DURANODIC ANODIZED, MEDIUM BRONZE COLOR; IN <br />ELECTROSTATICALLY APPLIED BAKED ENAMEL, MEDIUM BRONZE COLOR, OR <br />FOR OTHER COLORS CONTACT FACTORY.) <br />D. CONSTRUCTION <br />1. FRAMES SHALL BE ASSEMBLED IN TWO SECTIONS, DOOR SIDE (MASTER <br />SECTION) AND ADJUSTER SIDE (TRIM SECTION), WITH SNAP -ON TYPE STOP <br />COVER PLATES. ASSEMBLY OF EACH SECTION SHALL BE WITH MITERED <br />CORNERS ATTACHED WITH ALUMINUM CORNER GUSSETS WELDED INTO <br />POSITION AT THE FACE, RIBBED .57" (14.5 MM) ALUMINUM DRIVE FIT <br />CORNER KEYS AT THE RABBET AND .062" (1.6 MM) RIVETED CORNER <br />ANGLES AT THE INSIDE CONCEALED LEGS. WELDING OF ALUMINUM FACES <br />SHALL NOT BE ACCEPTABLE. <br />2. INTERNAL HARDWARE REINFORCEMENT FOR HINGES AND LOCK STRIKE <br />SHALL BE ALUMINUM EXTRUSIONS, MILL FINISH, STAKED IN POSITION. <br />HINGE AND LOCK STRIKE REINFORCEMENTS SHALL BE ADJUSTABLE BY AT <br />LEAST 1 /8° (3.2 MM). HEAD FACE SHALL BE REINFORCED WITH 1 /8- <br />(3.18 MM) ALUMINUM PLATE 12- (304.8 MM) LONG FOR CLOSER ARMS <br />WHERE REQUIRED. HEAD AND JAMB INTERNAL ALIGNMENT PARTS SHALL <br />BE ALUMINUM EXTRUSIONS, MILL FINISH, STAKED IN POSITION. <br />3. HARDWARE MORTISE LIP EXTRUSION SHALL BE .134- (3.4 MM) HIGH, <br />NOTCHED AT LOCATION OF HINGES, STRIKES AND OTHER MORTISE <br />HARDWARE. RABBET SHALL BE PUNCHED WITH SLOTTED HOLES FOR <br />ADJUSTABILITY OF HINGES AND LOCK STRIKES. <br />4. FRAME SHALL BE PROVIDED WITH A VINYL BULB GASKET AROUND THE <br />ENTIRE PERIMETER OF THE DOOR OPENING, STAKED INTO POSITION AT <br />CONCEALED LOCATIONS. <br />5. DOOR SIDE AND ADJUSTER SIDE SHALL BE ASSEMBLED AT THE FACTORY <br />FORMING A COMPLETE FRAME. <br />E. HARDWARE PREPARATIONS <br />1. FRAMES SHALL BE REINFORCED, DRILLED AND TAPPED FOR HINGES AND <br />LOCK STRIKE. REINFORCE ONLY FOR SURFACE MOUNTED HARDWARE. HOLES <br />FOR EXTENSION FLUSH BOLTS SHALL BE DRILLED IN THE FIELD BY INSTALLER <br />AFTER INSTALLATION OF DOORS AND FLUSH BOLT. <br />2. HARDWARE ITEMS ATTACHING TO THE SNAP -ON STOP CAPS MUST BE <br />ATTACHED THRU CLEARANCE HOLES IN THE CAP (FIELD DRILLED BY <br />INSTALLER) WITH SCREWS OF SUFFICIENT LENGTH TO ATTACH DIRECTLY TO THE <br />BACK OF THE DOOR SECTION OF THE FRAMES. NONSTANDARD SCREWS MAY <br />BE REQUIRED BY FINISH HARDWARE SUPPLIER OR INSTALLER. <br />3. FRAME IS NOT DESIGNED FOR USE WITH TOP/BOTTOM PIVOT HINGES OR <br />DOUBLE ACTING DOORS. <br />F. WALL PREPARATIONS <br />1. PROVIDE ROUGH OPENINGS IN FINISHED WALLS FOR INSTALLATION OF <br />DOOR FRAME. ROUGH OPENING SIZES AND DETAILS TO BE PROVIDED BY <br />THE FRAME MANUFACTURER. <br />2. WALL OPENINGS SHALL BE PROVIDED WITH WOOD STUDS OR MINIMUM <br />16 GAGE STEEL STUDS AT THE JAMBS. LIGHT GAGE STEEL STUDS MY BE <br />USED AT THE HEAD. <br />3. MASONRY WALLS SHALL BE PROVIDED WITH A 2 X 4 OR SIMILAR WOOD <br />STUD FINISHED WITH GYPSUM WALLBOARD BOTH SIDES FOR ATTACHMENT <br />OF THE FRAME. <br />G. FRAME INSTALLATION <br />1. INSTALL FRAMES IN STRICT ACCORDANCE WITH MANUFACTURER'S <br />INSTALLATION INSTRUCTIONS. <br />2. MANUFACTURER TO PROVIDE ALL NECESSARY INSTALLATION MATERIALS <br />FOR INSTALLATION IN WOOD OR STEEL STUD WALLS. PROVIDE ALL SCREWS AS <br />REQUIRED FOR A COMPLETE INSTALLATION. <br />3. ALL INSTALLATION MATERIALS ARE TO BE FULLY CONCEALED UPON <br />COMPLETION OF THE INSTALLATION. <br />H. FIRE RATING <br />1. ALL FRAMES SHALL BE PROVIDED WITH FIRE RATING OF 20 MINUTES OR <br />3/4 HR 'C' WHERE LISTED ON THE DOOR SCHEDULE. ATTACH LABELS FROM <br />AN APPROVED TESTING LABORATORY FOR ALL FRAMES THAT COMPLY WITH <br />THE MANUFACTURER'S PROCEDURE AND NFPA 80. OPENINGS THAT DO <br />NOT COMPLY FULLY WITH THE REQUIREMENTS OF AN ALUMINUM FIRE RATED <br />FRAME SHALL BE SO LISTED ON THE SHOP DRAWING SCHEDULES AND SHALL <br />BE FURNISHED WITH A CERTIFICATION LABEL ATTACHED. <br />PART III - EXECUTION <br />A. STORAGE <br />1. STORE FRAMES IN UNOPENED CARTONS OFF THE FLOOR. <br />B. INSTALLATION & INSPECTION <br />1. INSTALL FRAMES INTO ROUGH OPENINGS THAT COMPLY WITH <br />MANUFACTURER'S RECOMMENDATIONS. IF INSPECTION REVEALS <br />DEFICIENCIES IN THE OPENING , CORRECT BEFORE INSTALLING FRAMES. <br />2. INSTALL FRAME IN STRICT ACCORDANCE WITH MANUFACTURER'S <br />INSTALLATION INSTRUCTIONS. <br />3. CARPENTER OR FURNITURE CLAMPS SHALL BE USED TO SECURE THE <br />FRAME RETURN TIGHT AGAINST THE WALL DURING INSTALLATION. <br />C. ADJUSTMENTS & CLEANING <br />1. ADJUST FRAMES TO PLUMB AND SQUARE CONDITION. SNAP -ON JAMB <br />STOP COVER PLATES ARE TO BE INSTALLED AFTER ALL FINAL ADJUSTMENTS <br />HAVE BEEN MADE. <br />2. ADJUST ALL FIRE LABELED FRAMES TO TOLERANCES REQUIRED BY NFPA <br />80, SECTION 2-5.4. <br />3. CLEAN ALUMINUM FRAMES WITH A MILD COMMERCIAL CLEANER OR <br />WITH MINERAL SPIRITS. DRY WIPE WITH A SOFT CLOTH THE REMOVE ALL <br />CLEANE <br />DIVISION NO. 8 DOORS AND WINDOWS: <br />008100 CEILING ACCESS DOOR: <br />A. MATERIALS: <br />1. CONSTRUCTION <br />a. METALS: GALVANIZED STEEL <br />FRAME - 16GA MIN. <br />PANEL - 18 GA MIN. <br />LINER - 22 GA MIN. <br />b. INSULATION - 1-1/2" HIGH TEMP INSULATION <br />c. NON COMBUSTIBILITY CLASSIFICATION <br />CAN/ULC S114, ASTM E136, CAN/ULC S102, ASTM E84 <br />UL723, FLAME SPREAD = 0, SMOKE DEVELOPMENT = 0 <br />2. PRIMER COAT: <br />a. PRIME COAT OVER STEEL - ONE COAT MFR.'S STANDARD <br />ELECTROCHEMICALLY APPLIED RUST INHIBITIVE PRIME COAT. <br />3. MANUFACTURED DOOR AND FRAME UNITS: <br />a. INSULATED, SURFACE MOUNTED, UPWARD OPENING, FIRE <br />RATED, CEILING ACCESS <br />b. PROVIDE WARNOCK HERSEY LABEL INDICATING CLASSIFIED <br />RATING FOR LABELED <br />OPENINGS. <br />c. CONCEALED CONTINUOUS PIANO HINGE. <br />d. STANDARD FACTORY LATCH FOR FIRE RATED ASSEMBLY <br />e. MAXAM METAL PRODUCTS: VAN -MET MODEL FAI-150 <br />2 HR. FIRE RATED OR APPROVED EQUAL. <br />DIVISION NO. 8 DOORS AND WINDOWS: <br />008210 WOOD DOORS: <br />A. MATERIALS: <br />1. INDUSTRY STANDARDS: <br />a. AWI: ARCHITECTURAL WOODWORK QUALITY STANDARDS, GUIDE SPECS., <br />QUALITY CERTIFICATION PROGRAM, CURRENT EDITION. <br />b. NWWDA:; INDUSTRY STANDARD I.S. SERIES. <br />2. WARRANTY: DOORS: LIFE OF THE INSTALLATION AGAINST DELAMINATION OR <br />WARP. PROVIDE FOR FINISHED REPLACEMENT; INCLUDE PROJECT SITE <br />LABOR AND MATERIALS. <br />3. ACCEPTABLE MANUFACTURERS: <br />a. MARSHFIELD DOORSYSTEMS, INC. <br />B. MANUFACTURED UNITS: <br />1. TYPE: NWWDA L.S. 1-87, GRADE II, AND <br />AWI SECTION 1300, CUSTOM GRADE, SOLID CORE. <br />2. GENERAL: FIVE PLY CONST., 28-32 DENSITY <br />PARTICLE BOARD CORE, ANSI A208.1, GRADE <br />1-L-1, AWI SECTION 1300 PC-5. <br />3. EDGE BANDS & MOULDINGS: MATCH FACE VENEER. <br />4. ADHESIVE: COMMERCIAL STANDARD CS 171, TYPE II, <br />WATER RESISTANT. <br />5. FACTORY FABRICATED CUTOUTS IN LABELED DOORS ONLY - <br />(NOTE: FIELD FABRICATED OPENINGS ARE PROHIBITED). <br />6. LABEL: UL OR WHI RATED LABELS ATTACHED ON RATED DOORS. <br />7. FINISH: FACTORY <br />8. GLAZING AS SCHEDULED. <br />9. DOOR SKINS: <br />a. AWI SECTION 200 S 8, GRADE II. (STAIN GRADE). <br />b. FACE VENEER: <br />SPECIES AND CUT: ROTARY BIRCH. <br />VENEERS: BOOK MATCHED <br />THICKNESS: Ym" <br />CROSSBAND: Yto", THICKNESS. <br />c. WOOD BEADS & APPLIED MOULDINGS: AWI GRADE. <br />10. GLAZING: Y4" TEMPERED SAFETY GLASS MEETING ANSI Z97.1-1984 <br />PROVIDE GLAZING BEADS WITH MITERED CORNERS, MATCH DOOR <br />SPECIES. PROVIDE NFPA 80 TRIM ® RATED DOORS. <br />GENERAL NOTE: <br />TENANT IMPROVEMENTS WILL <br />REQUIRE A VARYING AMOUNT OF <br />IMPROVEMENTS UNDER THIS <br />PROJECT SCOPE OF WORK. <br />THEREFORE, SOME OF THESE <br />SPECIFICATIONS MAY ONLY RELATE <br />TO A SMALL PORTION OF THE <br />WORK, OR IN SOME CASES NONE <br />AT ALL. <br />cz <br />(1) <br />C <br />L <br />o <br />� <br />4- <br />L <br />• <br />c <br />a) <br />'a <br />c <br />z <br />0 <br />0 <br />`c <br />o <br />U <br />0) <br />L) <br />U <br />LCD <br />O <br />o <br />c c <br />x x <br />+j <br />o <br />(2) <br />U <br />•ri <br />L. <br />c <br />a_ <br />L. <br />C <br />L <br />+_j <br />m <br />o <br />C <br />e <br />4- <br />o <br />• 1 <br />a) <br />0 <br />a <br />-0 <br />11' ,, u1.. slte'6had heH,•. ors r,alip{ - # 6 <br />orlglnal dmr ln,, These. sccles are hereby <br />changed ay the rcdo of tre av 11 sheet <br />rnl not rh <br />U <br />U) <br />U <br />Q <br />("M <br />U <br />co <br />� <br />0 <br />o <br />M <br />Q <br />o_ <br />I <br />H <br />1 <br />O <br />O <br />� <br />N <br />O <br />m <br />� <br />t- <br />z <br />Q <br />x <br />C J <br />H <br />H <br />c� <br />c7 <br />0 <br />o <br />Q <br />O <br />_(D <br />H <br />-1 <br />1` <br />X <br />N <br />m <br />Q <br />LLL <br />z <br />0 <br />Q <br />U <br />O <br />_ 1 <br />W <br />,- <br />LO <br />. <br />CM <br />U <br />o <br />M <br />VJ <br />z_ <br />- <br />~ <br />m <br />Q <br />z <br />J <br />W <br />J <br />J <br />CL <br />W <br />= <br />N <br />Z <br />W <br />N <br />DRAWN BY: <br />LJ/CH <br />DATE: 03/12/13 <br />PROJECT NO.1230 <br />REV. <br />R_ <br />R_ <br />REVISIONS <br />Sheet No. <br />T-4 <br />