Laserfiche WebLink
O <br />DATE SCALE: II PAGE I <br />3116120 114 = 1-0 <br />METAL FLASHING AT ALL EAVES, SIDEWALLS, AND RAKES <br />-- PROVIDE HEMMED EDGES SO AS TO FORM DRAINAGE <br />CHANNELS AND PREVENT CAPILLARY ACTION <br />METAL ROOFING <br />CRICKET AT TOP -SIDE OF <br />CHIMNEY <br />WALL SHEATHING <br />SIDEWALL FLASHING <br />FINISH WALL AND MOISTURE <br />BARRIER TO LAP FLASHING <br />AT WALL -- MAINTAIN GAP <br />BETWEEN WALL FINISH AND <br />ROOFING TO AVOID SOAKING <br />PROVIDE HEMMED EDGE AT <br />FLASHING TO FORM CHANNEL <br />AND SO AS TO MAINTAIN AIR <br />GAP TO PREVENT CAPILLARY <br />ACTION <br />FLASHING GOES UP THE <br />CHIMNEY FRAME WALLS 8" <br />FLASHING LAPS METAL ROOFING <br />6 INCHES <br />BASE FLASHING WRAPS CORNERS, <br />EXTENDS OVER METAL ROOFING AT <br />SIDES 6 INCHES AND LAPS AT BASE <br />MIN, 6 INCHES <br />FLASHING DETAILS / NOTES <br />METAL ROOFING <br />RAT <br />RUN <br />BRACING <br />MAX <br />SPACING i <br />'-0" <br />OC <br />GABLE BRACING / SEE THE TRUSS LAYOUT <br />THE CHIMNEY CAP WILL BE FASTENED TO <br />THE DBL TOP PLATE OF THE FRAMING WITH <br />3" X 010 DECK SCREWS 8" OC AND ON EACH <br />SIDE OF ALL CORNERS, <br />2x6 SPLICE BLOCKS WILL BE REQUIRED FOR EVERY <br />8'-0" OF HEIGHT ADDED TO THE CHIMNEY <br />2x6 BEVELED BOTTOM PLATE OF THE WALLS <br />SET ON THE TOP CHORD OF THE ROOF TRUSSES, <br />USE BLOCKING BETWEEN THE TRUSSES UNDER <br />ALL BOTTOM PLATES. <br />USE 1/2" THREADED RODS FROM THE BLOCKING UNDER THE <br />TOP CHORD OF THE ROOF TRUSSES UP TO THE TOP OF THE <br />DBL TOP PLATE OF THE CHIMNEY WALLS. A THIRD PLATE <br />WILL BE ON TOP FOR A SPACER FOR THE THREADED RODS <br />WITH 2" SQUARE STEEL WASHERS AND NUTS. <br />1/2" THREADED RODS <br />2x TOP CHORD <br />SIMPSON H2.5A <br />2x6 BEVELED BLOCKING <br />ROOF TRUSSES <br />AT LEAST ONE TRUSS SPACE LAPPED <br />MIN (2) 12d PER JOINT <br />IX4 <br />CONTINUOUS 02 PINE <br />TRUSS BRACING <br />RAT -RUN BRACING DETAIL <br />MAX OF 10'-O" OC SPACING <br />MIN 2X6 02 PINE TOP CHORD <br />X-GROSS BRACING <br />MIN' OF (2) <br />12d COMMONS <br />PER TRUSS JOINT <br />BOTTOM CHORD AND X-JOINT <br />DBL *2 SPRUCE 2x4 TOP PLATES <br />36" MIN DISTANCE ABOVE <br />THE CLOSEST ROOF LINE WITHIN <br />10'-0" HORIZONTAL DISTANCE <br />FROM THE TOP OF THE CHIMNEY <br />X-BRACING MIN 1X4 <br />20'-0" OC MAX, CONTINUOUS "2 PINE <br />TRUSS BRACING <br />X-BRACING DETAIL <br />NAIL THE 2X6 MEMBERS OF THE X-GROSS BRACING <br />INTO THE VERTICLE WEBS OF THE ROOF TRUSSES WITH <br />(2) 12d GALV, COMMONS. <br />USE VALLEY SET TRUSSES <br />FOR THE CHIMNEY CRICKET <br />FRAMING NOTES: <br />DESIGN SERVICES INC. <br />MOBILE/ OFFICE 352-206-5821 <br />R. $. HANLEY F O BOX 1325 SAN ANTONIO <br />FLA, 33516 <br />EMAIL: hanley06oembargmai I,com <br />CUSTOM HOMES AND BARNS <br />ALL DOOR HARDWARE AND TRACKS <br />TO BE INSTALLED PER THE DOOR <br />MANUFACTURERS SPECIFICATIONS, <br />2x6 02 PT SYP BOARD WILL BE ATTACHED TO THE FACE <br />OF THE FRAME WALLS WITH 1/2"x6" LAG BOLTS AND 2" <br />SQUARE STEEL WASHERS SPACED EQUALLY NO MORE <br />THAN 24" OC, <br />0 <br />0 <br />0 <br />a <br />a <br />0 <br />0 <br />0 <br />no <br />o <br />0 <br />0 <br />0 0 0 0 0 0 <br />GARAGE DOOR DETAIL / FRAME WALLS <br />JOB NAME and ADDRESS <br />�1/2" THREADED RODS FRAME THE ENTIRE FIREPLACE USING 2X4 "2 SPRUCE OR PINE. CALVIN and LINDSEY DOQUE <br />COVER THE FRAMING WITH A TYVEK VAPOR BARRIER AND 1/2" CDX OR PARCEL* 10-24-21-0010-09100-0020 <br />OSB. NAIL THE TOP AND BOTTOM EDGES OF THE SHEATHING WITH Sd <br />GALV, COMMONS 3" OC AND ALL OTHER AREAS (o" OC. S th AVE ZE10HYRHILLS, FLORIDA <br />2x6 BEVELED BLOCKING BUILD (2) 2 PLY BEVELED 2x6 BLOCKS WITH A 1/2" SPACER 33542 <br />TO EXTEND AT LEAST 28" PAST EACH END OF THE CHIMNEY, <br />ATTACH THIS BLOCKING TO THE TOP CHORD OF EACH ROOF <br />TRUSS WITH SIMPSON A H2,5A HURRICANE TIE. MAIN LIVING AREA 21roro SF <br />RUN A 1/2" THREADED ROD UP THRU THE BLOCKING TO THE FRONT ENTRY 86 SF <br />TOP OF THE CHIMNEYS FRAME WALL AND SECURE WITH A REAR COVERED PORCH 43ro SF <br />2 SQUARE WASHER AND NUT. SEE THE TRUSS LAYOUT FOR <br />THE LOCATION OF THE BLOCKING AND THREADED RODS. GARAGE 495 SF <br />HEATILATOR PRE FAB <br />FLUE LINER TO FIREBOX <br />FRAME WALL FIREPLACE DETAILS <br />TOTAL UNDER ROOF <br />3183 SF <br />DAY ID W. SMITH, MS. PE. <br />FLORIDA LIC.* 53606 <br />352-521-0865 OFFICE 352-521-086l FAX, <br />9905 WALLASTON DRIVE DADE CITY ,FLA, 33525 <br />I HEREBY CERTIFY THAT I HAVE REVIEWED THIS <br />PLAN AND FOUND IT TO BE IN COMPLIANCE WITH <br />ASCE '7-10 AND THE 2011 FLORIDA BUILDING CODE <br />6th EDITION, <br />DAVID W. SMITH, MS, PE. LIC.* 53608 <br />