- - _I ! I I I I It 7 1
<br />GENERAL DEMOLITION NOTE:
<br />1. THE FOLLOWING REQUIREMENTS FOR DEMOLITION, CUTTING AND PATCHING APPLY TO ALL WORK WHICH
<br />IS ALTERED, WHETHER SUCH WORK IS NEW, EXISTING, RENOVATED OR REPLACED:
<br />I 2. ASBESTOS SURVEY AND ABATEMENT: PRIOR TO DEMOLITION CUTTING TT NG OR PATCHING WORK, ENGAGE A
<br />LICENSED ASBESTOS CONTRACTOR TO PERFORM AN ASBESTOS SURVEY, WHICH IDENTIFIES SPECIFIC
<br />LOCATIONS WHERE ASBESTOS CONTAINING MATERIALS ARE FOUND, AND WHICH PRESCRIBES SPECIFIC
<br />I I ACTIONS REQUIRED FOR ABATEMENT. ENGAGE A LICENSED ASBESTOS ABATEMENT CONTRACTOR TO
<br />REMOVE OR ENCAPSULATE ALL ASBESTOS CONTAINING MATERIALS, ACCORDING TO THE
<br />EXISTING RECOMMENDATIONS OF THE ASBESTOS CONSULTANT. WHERE ASBESTOS CONTAINING MATERIALS ARE
<br />ENCAPSULATED IN THE BUILDING, PROVIDE THE OWNER WITH A DETAILED DESCRIPTION OF ALL
<br />' °"Xio-°• REMAINING MATERIALS, INCLUDING LOCATIONS, APPROXIMATE QUALITIES, AND METHODS OF ECAPSULATED
<br />AND INSTRUCTIONS FOR NOT DISTURBING THE ENCAPSULTED MATERIALS.
<br />� I /
<br />3. PRIOR TO DEMOLITION, CUTTING AND PATCHING, THE CONTRACTOR SHALL LOCATE AND DISCONNECT
<br />UTILITY SERVICES AND ELECTRICAL / MECHANICAL SYSTEMS, OR TEMPORARILY CAP OFF SUCH SERVICES
<br />3 TO THE AFFECTED AREAS. GIVE NOTICE TO, AND COORDINATE WITH UTILITY COMPANIES. OBTAIN
<br />WRITTEN APPROVAL FROM, AND COOPERATE WITH OTHER PARTIES WHO MAY BE AFFECTED BY
<br />INTERRUPTION OF SERVICES.
<br />4. CLEARLY MARK THE AREAS AND LIMITS OF DEMOLITION, CUTTING AND PATCHING. IF FEASIBLE,
<br />PRE—CUT THE LINE OF SEPARATION BETWEEN AREAS OF DEMOLITION AND AREAS TO BE PRESERVED.
<br />UTILIZE DEMOLITION AND CUTTING TECHNIQUES WHICH ARE LEAST LIKELY TO DAMAGE SURROUNDING OR
<br />w'wcR
<br />I'v ,s o°- ADJOINING WORK. WHERE FEASIBLE, USE HAND TOOLS AND SMALL POWER TOOLS THAT ARE DESIGNED
<br />FOR SAWING AND GRINDING, NOT HAMMERING OR CHOPPING. DO NOT USE EXPLOSIVES.
<br />S. STRUCTURAL REQUIREMENTS: DO NOT CUT AND PATCH STRUCTURAL WORK IN A MANNER WHICH WILL
<br />I
<br />2 x REDUCE LOAD —CARRYING CAPACITY OR LOAD —DEFLECTION RATIO. WHERE STRUCTURAL WORK MUST BE
<br />X CUT, PROVIDE ADEQUATE TEMPORARY SUPPORT (BRACING AND/OR SHORING) TO RESIST VERTICAL,
<br />1 I I LATERAL AND DYNAMIC LOADS IN THE ENTIRE TRIBUTARY AREA OF THE AFFECTED STRUCTURAL
<br />Rc"� X MEMBERS. WHERE REQUIRED, ENGAGE A LICENSED STRUCTURAL ENGINEER TO DESIGN SHORING /
<br />EXISTING EXISTING EXISTING
<br />BUFFET TABLE BUFFET TAB E BUFFET TAB E / / BRACING SYSTEMS AND JOINT OR CONNECTION DETAILS.
<br />--- - - 6. OPERATIONAL AND SAFETY LIMITATIONS: DO NOT CUT AND PATCH OPERATIONAL ELEMENTS OR SAFETY
<br />RELATED COMPONENTS IN A MANNER WHICH WILL REDUCE INTENDED PERFORMANCE OR SAFETY FACTOR,
<br />OR WHICH WILL RESULT IN INCREASED MAINTENANCE OR REDUCED OPERATIONAL LIFE.
<br />7. VISUAL REQUIREMENTS: DO NOT CUT AND PATCH WORK IN A MANNER WHICH WILL RESULT IN
<br />II
<br />LESSENING OF THE AESTHETIC QUALITIES OF THE BUILDING OR SITE, OR THAT WILL RESULT IN VISUAL
<br />EVIDENCE OF CUT AND PATCH WORK. WHERE REQUIRED, EXTEND FINISH MATERIALS OVER ENTIRE
<br />N ,4 1XI UNBROKEN SURFACE AREAS AFFECTED BY CUT AND PATCH WORK. REMOVE AND REPLACE CUT AND
<br />PATCH WORK WHICH DOES NOT MEET VISUAL REQUIREMENTS.
<br />I
<br />1 8. PROTECTION: PROTECT OTHER WORK DURING CUTTING AND PATCHING OPERATIONS TO PREVENT
<br />I� DAMAGE. PROVIDE PROTECTION OF ALL WORK FROM ADVERSE WEATHER CONDITIONS. WHERE
<br />OPENINGS ARE CREATED IN ROOF OR EXTERIOR WALLS, PROVIDE TEMPORARY ENCLOSURE OF SUCH
<br />OPENINGS ON A DAILY BASIS, AND WHENEVER ADVERSE WEATHER THREATENS OR EXISTS.
<br />ID
<br />1
<br />DE- O❑TON PLAN
<br />DEMl: _.ITION KEYED NOTES: I )
<br />1. _�'EMOVE EXISTING PARTITION AND COUNTERS. TO REMOVE UNUSED ELECTRICAL WIRING BACK
<br />10 NEAREST JUNCTION BOX.
<br />2. ' 0 REMOVE EXISTING HOOD SYSTEM IN THE KITCHEN AREA
<br />3. -10 DEMOLISH EXISTING RESTROOM.
<br />4. ='OWER PANELS TO BE REMAINED.
<br />5. 10 STRUCTURAL WORK.
<br />6. 1,CCUMULATION OF AMBULATION OF COMBUSTIBLE WASTE MATERIAL, DUST, AND DEBRIS SHALL
<br />,E REMOVED FROM THE STRUCTURE AND ITS IMMEDIATE VICINITY AT THE END OF EACH WORK
<br />:.�HIFT OR MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATIONS. NFPA 1:16.2.2.1
<br />7. ,URING DEMOLITION EXITS AND FIRE SAFETY EQUIPMENTS SHALL BE CLEARLY VISIBLE AND
<br />..iNOBSTRUCTED.
<br />8. 7 XISTING CEILING SYSTEM TO BE REMAINED
<br />9. =',NY STRUCTURAL WORK AND THE PROPOSED TEMPORARY BRACING TO MAINTAIN THE
<br />:TRUCTURAL INTEGRITY DURING CONSTRUCTION.
<br />ELECTRICAL DEMOLITION NOTES
<br />1 . THE CONTRACTOR SHALL REMOVE ALL UNUSED AND ABANDONED WIRING AND CABLING FROM THE
<br />CEILING THAT ISN'T LABELED FOR FUTURE USE, AS REQUIRED BY THE NEC. THIS SHALL INCLUDE BUT
<br />IS NOT LIMITED TO FIRE ALARM, POWER, SECURITY, CONTROLS, DATA, TELEPHONE, A/C ETC.
<br />2.CIRCUITS MADE SPARE SHALL BE UPDATED ON PANEL SCHEDULES. DIRECTORY CARDS SHALL BE
<br />REPLACED WITH NEW TYPED DIRECTORIES, INCLUDING ALL NEW LOADS IN ADDITION TO SPARES.
<br />HAND —MARKED NOTES WILL NOT BE ACCEPTED.
<br />3.CARE SHALL BE TAKEN TO RELOCATE ALL EXISTING EQUIPMENT THAT IS BEING MOVED BUT REMAINING
<br />AFTER COMPLETION OF WORK. THE CONTRACTOR SHALL BE RESPONSIBLE TO KEEP ALL EXISTING TO
<br />REMAIN OR RELOCATED EQUIPMENT AT THE SAME LEVEL OF FUNCTIONALITY FROM THE ACCEPTANCE OF
<br />THE CONTRACT OF FINAL COMPLETION. ANY DAMAGE OR LOSS OF FUNCTIONALITY SHALL BE REMEDIED
<br />BY THE CONTRACTOR AT NO ADDITIONAL EXPENSE TO THE OWNER.
<br />4.EQUIPMENT INDICATED TO BE REMOVED AND NOT RE —USED SHALL REMAIN THE PROPERTY OF THE
<br />OWNER AND RETURNED OR STORED AS DIRECTED.
<br />5.CONDUITS AND RACEWAY SYSTEMS MAY BE ABANDONED WHERE CONCEALED HOWEVER SHALL BE
<br />REMOVED WHERE EXPOSED. REMOVED OUTLETS SHALL BE PROVIDED WITH BLANK COVERS, COLOR PER
<br />THE ARCHITECT'S DIRECTION.
<br />6.EXISTING RACEWAYS AND WIRING ARE ALLOWED TO BE RE —USED PROVIDED THEY MEET THE
<br />SPECIFICATIONS FOR THE NEW SYSTEM(S).
<br />7.ALL OUTAGES SHALL BE COORDINATED WITH THE OWNER. THE CONTRACTOR SHALL PLAN TO MINIMIZE
<br />ALL OUTAGES.
<br />8.CIRCUITS SHALL STAY FUNCTIONAL WHERE DEVICES/FIXTURES ARE BEING DEMOLISHED THAT SHARE A
<br />COMMON CIRCUIT WITH DEVICES/FIXTURES THAT ARE TO REMAIN. WIRING SHALL BE REMOVED AS FAR
<br />AS POSSIBLE WHILE MAINTAINING EXISTING TO REMAIN OPERATION.
<br />9.THE CONTRACTORS SHALL REMOVE ALL EXISTING ELECTRICAL EQUIPMENT NOT REUSED OR NOT
<br />NECESSARY FOR THE COMPLETION OF THIS PROJECT.
<br />U
<br />o
<br />Q�
<br />Zo�Q�
<br />0p
<br />m
<br />O M M
<br />m w w
<br />J uj
<br />00 d
<br />Cn ¢ U)
<br />uj ui
<br />0 V) n¢
<br />zw'�Q�wZ
<br />mEs Uz
<br />00
<br />~ QQ JO
<br />Z
<br />W
<br />QC7aw�
<br />NNF�-ZZ
<br /><
<br />0
<br />�Q;.•
<br />��2;� Q
<br />•�,; �(, of
<br />�• �. _
<br />ul
<br />z
<br />:U
<br />O•LJ
<br />• I �i
<br />� y. O � -J
<br />Q ,'o
<br />Uj
<br />&all as
<br />U
<br />Q
<br />0
<br />Q
<br />Q
<br />0
<br />w
<br />�
<br />z
<br />Q
<br />M
<br />z
<br />z
<br />0
<br />U
<br />Z Q
<br />W
<br />z
<br />0
<br />W W
<br />J
<br />U O
<br />W
<br />tY
<br />w
<br />C� M
<br />N
<br />c
<br />REVISION
<br />1 1
<br />2
<br />3
<br />4
<br />5
<br />6
<br />7
<br />PROJECT TYPE:
<br />RENOVATION
<br />SCALE
<br />AS SHOWN
<br />ISSUED DATE:
<br />03_08_2024
<br />DRAWN BY:
<br />A.FENG
<br />CHECKED BY:
<br />A.LIANG
<br />SHEET
<br />■yaw
<br />
|