Laserfiche WebLink
UNIT SHALL HAVE A 30 YEAR WARRANTY <br />WITH A 5 OHM GROUND AND INSPECTION <br />AS NOTED. NO EXCEPTIONS <br />TOP <br />PRODUCTS SHALL BE PSI. CALL 407-380-9200 JOHN WEST <br />TWIST ALL LEADS TOGETHER WITH AS MOUNTED <br />TURNS AS PRACTICAL AND AND NEATLY TIE <br />WRAP. CONDUCTORS SHALL BE AS SHORT AS <br />SIDE MOUNT SURGE SUPPRESSION DEVICE WHEREVER POSSIBLE, TOP <br />POSSIBLE DO NOT EXCEED 6 FEET <br />SPD <br />MOUNTED WHERE THERE IS NO SPACE ADJACENT TO PANEL, BOTTOM <br />MOUNT IS REQUIRED WHEN PANEL HAS BOTTOM FEED LUGS <br />UTILIZE TVSS FURNISHED CHASE NIPPLE <br />MODIFY NIPPLE FOR ATTACHING SURGE DEVICE <br />THE CONTRACTOR SHALL COORDINATE INSTALLATION METHODS WITH <br />TO PANEL <br />THE MANUFACTURER'S REP. THE CONTRACTOR SHALL SUBMIT COLOR <br />LOCATE BREAKER IN POSITION CIRCUIT 1 OR <br />PHOTOGRAPHS OF THE ACTUAL INSTALLATION. TAG EACH PHOTO <br />2 FOR TOP FEED OR BOTTOM LEFT OR RIGHT <br />djG <br />WITH THE PANEL DESIGNATION. PHOTOS SHALL INCLUDE BOTH <br />POSITION BOTTOM FEED. BREAKER AND TVSS <br />EXTERIOR VIEW AND INTERIOR POWER WIRING VIEW. SUBMIT PHOTOS <br />SHALL HAVE A WITHSTAND AIC RATING <br />TO THE MANUFACTURER'S REP. CORRESPOND TO THE REP FOR <br />EQUAL OR HIGHER THAN THE PANELBOARD <br />ANY CORRECTIONS REQUIRED FOR ACCEPTANCE. IF ADDITIONAL <br />RATING <br />INFORMATION IS REQUIRED BY THE MANUFACTURER'S REP THE <br />30/3P <br />CONTRACTOR SHALL COMPLY TO DIRECTIONS AND CORRECTIONS AS <br />MINIMUM TOTAL SURGE RATINGS <br />BREAKER <br />REQUIRED. UPON FINAL ACCEPTANCE BY THE MANUFACTURER'S <br />PER MODE PER CATEGORY; <br />REP, SUBMIT PHOTOS AND MANUFACTURER'S FINAL ACCEPTANCE TO <br />"B" = 50000 AMPS ALL PANELBOARDS <br />PANELBOARD <br />THE ENGINEER. CC ALL COPIES VIA E-MAIL OF ALL <br />"C" = 160000 AMPS MAIN DISTRIBUTION <br />OR <br />CORRESPONDENCE AND FINAL ACCEPTANCE TO THE ENGINEER. <br />PANEL AND DISTRIBUTION PANELS <br />DISTRIBUTION <br />FAILURE TO DO THIS TASK WILL VOID THE WARRANTY AND AS A <br />PANEL RESULT THE CONTRACTOR SHALL BE RESPONSIBLE FOR <br />REPLACEMENT OF TVSS UNITS AND COMPONENTS. THE COST OF <br />REPLACEMENT OR REPAIR WILL BE THE CONTRACTOR'S <br />MODES OF PROTECTION; RESPONSIBILITY AT NO COST TO THE OWNER. THE RESPONSIBILITY <br />SHALL BE IN AFFECT THROUGHOUT THE PERIOD OF THE <br />CATEGORY "C" PSI XNL-200 FOR MDP1 MANUFACTURER'S LISTED WARRANTY. PROVIDE SERIAL NUMBER WITH <br />SHOP DRAWINGS FOR WARRANTY RECORDING AND STATUS <br />30 YEAR WARRANTY WITH A 5 OHM GROUND <br />rD TRANSIENT VOLTAGE SURGE <br />�"o SUPPRESSION FOR POWER <br />NTS <br />BIMETALLIC <br />FITTING AND <br />ALUMINUM COPPER DOWN <br />GROUND LOOP CONDUCTOR <br />WHERE SHOWN <br />EXOTHERMIC <br />CONNECTION IN <br />TEST WALL <br />GROUND ROD <br />SECTIONAL <br />COUPLING PROVIDE <br />COPPER CLAD <br />SELF TIGHTENING <br />GROUND <br />COUPLINGS AT ALL <br />(3/4"x10-) <br />ROD EXTENSIONS <br />EACH. (4) MIN. <br />DEMARK TYPE ONLY <br />REQUIRED <br />GROUND ROD TOTAL <br />SECTION 40' LONG <br />MINIMUM 5 OHMS <br />MAXIMUM ADD PROVIDE HEAVY <br />ADDITIONAL LENGTHS DUTY TIP. <br />TO OBTAIN 5 OHMS DEMARK TYPE <br />MAX. ONLY <br />GROUND ROD <br />�"o NTS <br />TYPICAL SS 3/8" HOLD <br />DOWN BOLT, LOCK WITH SS <br />NUT AND WASHER <br />d d "J" TYPE <br />° QONFIGURATION <br />d 4 o <br />d° e <br />24" MIN. ABOVE <br />HIGHEST <br />SURFACE <br />• <br />ALUMINUM AIR <br />TERMINAL BLUNT <br />TIP <br />2'-0" MAX. TO OUTSIDE <br />EDGE OF ROOF OR <br />STRUCTURE <br />FLAT SURFACE BASE <br />ATTACHED TO TOP <br />SURFACE WITH ADHESIVE <br />MAIN CONDUCTOR <br />SUPPORT AT 3' O.C. <br />WITH ADHESIVE CLIPS <br />C FLAT BASE AIR <br />E30 TERMINAL TYPE A <br />KS <br />THE CONTRACTOR SHALL PROVIDE SIGNED AND SEALED DRAWINGS BY A <br />FLORIDA REGISTERED STRUCTURAL ENGINEER INCLUDE WIND LOAD <br />CALCULATIONS AND SOIL DATA <br />CONCRETE PAD BELOW GENERATOR W/ <br />DEPTH OF CONCRETE #5 REBAR 12"EW OC ALL CONCRETE <br />PAD SHALL BE PER THE 3000 PSI GRADE 6. 6" ABOVE GRADE <br />STRUCTURAL ENGINEER'S WITH DEPRESSED SLAB BELOW GRADE. <br />DRAWINGS PROVIDE SMOOTH FINISH AND 1/2" <br />CHAMFERED EDGES <br />lJ V d d TT <br />d n e e d de --_I <br />,° ° <br />ELEVATION 6" ABOVE FINISHED <br />1%MICDATAD DACC TAWV GRADE REQUIRED <br />PAD SHALL EXTEND 4" BEYOND THE TANK BASE <br />MINIMUM. THE TANK HOLD DOWN BOLTS, NUTS AND <br />WASHERS SHALL BE STAINLESS STEEL. LOCATE THE <br />BOLTS AT ALL FOUR CORNERS. COORDINATE TANK <br />HOLD DOWN BOLTS WITH THE REQUIRED 4" MINIMUM <br />LISTED CLEARANCE. BOLTS SHALL EXTEND AT LEAST <br />6" WITHIN THE PAD. PITCH THE PAD 1/16" SLOPE <br />TOWARDS THE FUEL FILL LINE. <br />JLI\L.IVIIVl% LA-WL. If -"\I\ <br />I COORDINATE CONDUIT CUTOUT <br />WITH MANUFACTURERS <br />GENERATOR TANK SPEC, I <br />CONTRACT DRAWINGS AND <br />TEMPLATE. I <br />29" X 14" I <br />306" <br />G PLAN VIEW <br />E30PAD FOR GENERATOR <br />NTS <br />104" <br />fCOPPER CABLE <br />IN 1 " PVC <br />1" PVC SCHED 40 UV RATED <br />CONDUIT WITH ANCHORS <br />f <br />2' MINIMUM BELOW <br />GRADE <br />2' MINIMUM <br />#115000 CM FROM STRUCTURE <br />COPPER CABLE \ <br />( TYPICAL ) <br />COPPERWELD GROUND ROD V I f1GnIMI%A <br />CONNECTION <br />3/4" X 40'-0" (MIN) DRIVEN VERTICALLY (TYPICAL) TEST WELL <br />LOCATED IN <br />1. LOCATE GROUND RODS A MINIMUM OF <br />2'-0" FROM BUILDING STRUCTURE <br />2. TOP OF GROUND ROD SHALL BE A MINIMUM <br />OF 6" BELOW FINISHED GRADE AND TOP OF ACCESS BOX <br />(--�B DOWNLEAD TO SINGLE <br />�009/GROUND ROD DETAIL <br />NTS <br />MATCH EXISTING <br />FINISH <br />1� — <br />MARKER "BURIED <br />• . . . � • • • • CONDUIT BELOW" <br />24" ........... <br />LEAN <br />• . . COMPACTED <br />CONDUITS AS BACKFILL <br />NOTED ON -a---COMPACTED <br />PLANS. PITCH . . . . . . . . . . . . CLEAN BASE <br />CONDUIT " " " <br />TOWARDS A <br />PULL BOX <br />WIDTH TO <br />ACCOMMODATE <br />CONDUITS <br />F <br />�009/TRENCH SECTION <br />NTS <br />COMPOSITE ACCESS COVER 13 3/4-W x - <br />23 1 /4"L.. PROVIDE TWO STAINLESS STEEL <br />HEX BOLTS W/ WASHERS AND SKID <br />RESISTANT SURFACE <br />- PROVIDE ENGRAVED <br />1 /2" HIGH <br />LETTERS "GROUND" <br />FINISHED GRADE <br />BOX DIMENSIONS; <br />EXOTHERMIC 15 1/2"W x 25"L TOP <br />CONNECTION 23"W x 32 1/21 BASE <br />ONLY 18" DEEP OUTSIDE 16" <br />DEEP INSIDE <br />COMPOSITE BOX = QUAZITE PT1324BA18 <br />TRAFFIC RATED — BOX W/ COVER <br />10000# RATED BOXES <br />TAGGED <br />PROVIDE A 8" 1 O2 do O3 <br />CONCRETE BLOCK <br />ON EDGE AT THE <br />PERIMETER OF <br />THE BOX <br />3" MIN. DEEP <br />LEAVE SPACE FOR PEA STONE GROUND CONDUCTOR NOT <br />CLAMP -ON METER END SECTION ELEVATION GREATER THAN 8" R <br />TESTER. LOCATE BEND. LOCATED 24" <br />ROD OFF IC^E TE ROD BELOW GRADE (TYPICAL) <br />3/4" GROUND ROD MINIMUM DEPTH 40' 5 OHMS ((� <br />MAX WITHOUT CABLE CONNECTED LOCATE OFF CLAMP -ON <br />CENTER IN BOX AS SHOWN PLAN MEW METER SPACE <br />('A <br />E3o GROUND ACCESS BOX <br />KS <br />PANEL <br />EO <br />EQUIPMENT BRANCH <br />EMERGENCY <br />120/208V 30 4W <br />FED FROM MSB <br />NORMAL <br />EMERGENCY FROM <br />GDP -AD AND <br />GENERATOR <br />PHASE A- BLACK <br />PHASE B- RED <br />PHASE C- BLUE <br />NEUTRAL- WHITE <br />GROUND- GREEN <br />KELLY GREEN WITH <br />WHITE LETTERS <br />PANEL MDP <br />NORMAL POWER <br />120/208V 30 4W <br />FED FROM MSB <br />PHASE A- BLACK <br />PHASE B- RED <br />PHASE C- BLUE <br />NEUTRAL- WHITE <br />GROUND- GREEN <br />BLACK WITH <br />WHITE LETTERS <br />REFER TO SPECIFICATIONS FOR ADDMONAL INFORMATION <br />PROVIDE LABELS WHERE EXISTING LABELS <br />ARE NOT INSTALLED. REVISE THE LABELS <br />BASED UPON "NORMAL SERVED FROM MDP <br />AND EMERGENCY SERVED FROM EDP-1 <br />PANEL <br />CRA <br />CRITICAL BRANCH <br />EMERGENCY <br />120/208V 30 4W <br />FED FROM MDP <br />NORMAL AND <br />EMERGENCY FROM <br />EDP1 AND <br />GENERATOR <br />PHASE A- BLACK <br />PHASE B- RED <br />PHASE C- BLUE <br />NEUTRAL- WHITE <br />GROUND- GREEN <br />ORANGE WITH <br />BLACK LETTERS <br />PANEL <br />LSA <br />LIFE SAFETY BRANCH <br />EMERGENCY <br />120/208V 30 4W <br />FED FROM MDP <br />NORMAL AND <br />EMERGENCY FROM <br />EDP1 AND <br />GENERATOR <br />PHASE A- BLACK <br />PHASE B- RED <br />PHASE C- BLUE <br />NEUTRAL- WHITE <br />GROUND- GREEN JI <br />YELLOW WITH <br />BLACK LETTERS <br />('E� NAMEPLATES <br />�"o NTS <br />w <br />c� <br />� z¢ <br />,04� U o <br />`N (� p w� <br />mz <br />Q N o v� <br />Z w <br />V •- m <br />W W m <br />0 <br />a: O z w <br />S�J o 3 - <br />Z � W cn LU <br />ZCD <br />n Z w <br />(`J�[ aC:)Z <br />m <br />w <br />Lr) <br />J —W �� J <br />Z NWJ Z <br />Nzo <br />W W <br />Z W CL 3wo <br />Z Z <br />C� z>-� <br />Z W <br />LU z?w <br />o� <br />�Nd <br />N <br />U Czo <br />) <br />00 ozQ <br />I�, U i <br />I waw <br />U Uo <br />14, <br />�.co ti 0 . <br />=o•z `4" o• - <br />F- <br />/ , <br />1 1 .•O��C�� <br />0 <br />REV <br />REV <br />REV 0 GENERAL REV. 02/13/18 <br />AHCA STAGE III MAIL -IN <br />REVIEW 12/26/17 <br />DATE 12/26/17 <br />DRAWN LF/BMA <br />CHKD BY BOB DONNELLY <br />i <br />E300 <br />