My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38220 Henry Dr (2)
Zephyrhills
>
Building Department
>
Building Plans
>
38220 Henry Dr (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2025 3:24:01 PM
Creation date
2/18/2025 3:25:05 PM
Metadata
Fields
Template:
Building Plans
Street #
38220
Location
Henry Dr
Contractor
Caledesi Construction
Building Plans - Permit #
20704
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1pf! ��HLMFWTE7 <br />DEPRESSED FOOTING BELOW <br />GENERATOR & BASE TANK. W/ #5 <br />REBAR 12"EW OC ALL CONCRETE 3000 <br />PSI GRADE 6 <br />N(--D---� <br />E2 OVERALL PLAN <br />NEW TRANSFER - <br />SWITCH ATS-EM <br />IN:C'i!w <br />NORMAL <br />--� ELEC <br />NEW S!2EMERG2ENCY <br />ROOM <br />ISTING <br />OVE EXISTING <br />ONDARY <br />CY <br />EDERS <br />NEW GENERAT <br />N,�% (B""� <br />GENERATOR PLAN LAYOUT <br />E2 0' 2' 4' 8' 16' <br />298" <br />96" <br />194' ALUMINUM <br />WEATHER <br />ENCLOSURE AND <br />A STATE CODE <br />LISTED BASE l } <br />LIGHTNING TANK. �, <br />PROTECTION INTERNAL— � <br />SEE O O MUFFLER 91" 11'-5" <br />DETAILS <br />I <br />I GENERATOR I <br />BASE TANK <br />35� BASE TANK <br />96"-�I• 6" <br />ELEVATION C-C <br />350 KW GENERATOR ELEVAl10NS WITH A NOA ENCLOSURE <br />�E200) Ms <br />11 <br />350 KW <br />120/208V. 30 4W DIESEL <br />GENERATOR <br />SEE NOTE 11. FLOW AT <br />100% EQUALS 26.5 GPH. <br />DEMAND LOAD IS 799E <br />WHICH EQXS 20.9 GPH. <br />TOTAL OF 96 RS OF <br />OPERATION 1999 <br />USEABLE GALLOW-UNIMUM <br />. SET LOW,,6E u AT <br />Z 1499 WAODE <br />HOURS. <br />rE <br />LISTED DOUBLE LINED BASE <br />TANK <br />THE CONTRACTOR SHALL PROVIDE <br />SIGNED AND SEALED DRAWINGS BY <br />A FLORIDA REGISTERED STRUCTURAL <br />ENGINEER SUBMIT WITH THE <br />GENERATOR SHOP DRAWINGS <br />6" REINFORCED CURB ABOVE GRADE FOR GENERATOR AND FUEL TANK. <br />SMOOTH FINISH (BRUSH FINISH IS NOT ACCEPTABLE), 1 /2" CHAMFER ON <br />EDGE. PITCH PAD TOWARDS FUEL INTAKE WITH A 1/16' SLOPE. EXTEND PAD <br />4' BEYOND TANK BASE. PROVIDE STAINLESS STEEL TANK HOLD DOWN BOLTS, <br />NUTS AND WASHERS. BOLTS SHALL BE PRESET WITHIN THE SLAB WITH A <br />RIGHT ANGLE "J' TYPE END. LOCATE ALL BOLTS PER THE MANUFACTURERS <br />TEMPLATE. <br />O AND DARE GROUND <br />ROD NUMBERS. <br />B <br />O n <br />REFER TO ELEVATION <br />DETAILS FOR DIMENSIONS <br />PROVIDE A FIRE <br />EXTINGUISHER It <br />ENCLOSURE <br />D <br />E2 <br />('-A EMERGENCY GENERATOR <br />E200 N 0' 2' 4' 8' 16' <br />NOTES <br />OPROVIDE A TEMPORARY GENERATOR AND QUICK CONNECT WHICH SHALL BE UTILIZED FOR THE EMERGENCY POWER <br />REQUIREMENTS UNTIL AN AHCA APPROVAL HAS BEEN SECURED. REMOVE THE TEMPORARY GENERATOR, FUEL TANK, MANUAL <br />TRANSFER SWITCH, WIRING AND QUICK CONNECT AFTER AHCA 100% INSPECTION APPROVAL THE GENERATOR CAN BE LEASED. <br />COORDINATE LOCATION PRIOR TO BID SUBMITTAL <br />OTHE CONCRETE PAD SHALL EXTEND 4' BEYOND THE GENERATOR BASE TANK AND 6' ABOVE GRADE. PROVIDE A DEPRESSED <br />SLAB PER WEIGHTS OF THE GENERATOR, FUEL TANK AND A FULL DIESEL TANK. A STRUCTURAL ENGINEER SHALL SIZE PADS <br />BASED UPON APPROVED SHOP DRAWINGS AND SOIL CONDITIONS. COORDINATE WITH THE ENGINEER. DATA SHOWN ON THIS PLAN <br />SHALL BE VERIFIED SUBMIT SIGNED AND SEALED STRUCTURAL DRAWINGS WITH THE SHOP DRAWINGS <br />3O PROVIDE A NEW 3/4-C FROM THE GENERATOR TO THE NEW ANNUNCIATOR PANEL THE PANEL SHALL BE LOCATED AT THE <br />NURSE STATION. EXTEND ABOVE THE CEILING TO THE EXISTING ANNUNCIATOR LOCATION AREA AT THE NURSE STATION. THE NEW <br />ANNUNCIATOR SHALL BE LOCATED WHERE DIRECTED BY THE OWNER'S REPRESENTATIVE. THE CONDUIT SHALL ALSO BE USED <br />FOR THE TEMPORARY GENERATOR. <br />4O PROVIDE THE EMERGENCY FEEDER FROM THE GENERATOR TO THE PANEL "D" LOCATION. REFER TO THE ONE -LINE DIAGRAM, <br />THIS PLAN AND SITE PLAN. <br />5O PROVIDE NEW HEATERS AND CHARGER 20A CIRCUITS. REFER TO THE PANELBOARD SCHEDULES. DO NOT SHARE NEUTRALS. <br />HEATERS SHALL DEACTIVATE WHEN THE GENERATOR STARTS PER 5.3.5 NFPA 110. CHARGER ON CIRCUIT EL-20. HEATER SHALL <br />BE ON CIRCUIT EC-10 <br />6O PROVIDE A BATTERY LIGHT CIRCUIT IN GENERATOR HOUSING. THE BATTERY AND LIGHTS ARE PROVIDED WITH THE GENERATOR. <br />CONNECT TO LIFE SAFETY CIRCUIT EL-19. REFER TO SCHEDULES <br />O7 PROVIDE 4' WP EXTERIOR WALL WRAPAROUND LED TYPE "Al". SWITCH SHALL BE KEY OPERATED TYPE WITH A BYPASS RELAY <br />TO OPERATE DURING EMERGENCY TRANSFER. PROVIDE PHOTOCELL FOR OFF DURING DAYLIGHT PERIOD. CONNECT TO THE LIFE <br />SAFETY CIRCUIT. REFER TO SCHEDULES. FIXTURE SHALL BE COLUMBIA LXEM4 40 ML RFA ED USSL TP.1. <br />SO PROVIDE (4)10' GROUND RODS MINIMUM TO PROVIDE A 5 OHM GROUND AT THE SERVICE ENTRY AND THE GENERATOR. RUN <br />COPPER DOWN CONDUCTOR IN 1" PVC UV LISTED SCHED 80. PROVIDE ACCESS BOX AND GROUNDING PER DETAILS <br />O9 THE GENERATOR TANK IS DOUBLE WALL HEAVY DUTY BASE MOUNT TYPE LOCATED BELOW GENERATOR. PROVIDE LEAK <br />SUPERVISION WIRING TO THE ANNUNCIATOR PANEL THE TANK SHALL BE NOA COMPLIANT <br />10 PROVIDE A WP GFI DUPLEX CONVENIENCE RECEPTACLE WITHIN THE ENCLOSURE. CIRCUIT TO LIFE SAFETY EL-19. REFER TO <br />PANEL SCHEDULES. <br />11 FUEL SHALL BE DIESEL PROVIDE A DIESEL BASE TANK AS PART OF THE GENERATOR PACKAGE. AS SPECIFIED PROVIDE A 100% <br />FILLED TANK AFTER FINAL TESTING AND 100% ACCEPTANCE. <br />12 PROVIDE 42' CLEAR MINIMUM DIMENSION FROM THE GENERATOR SIDES TO ANY OBSTRUCTION. PROVIDE 36" MINIMUM CLEAR <br />FROM ENDS <br />13 PROVIDE A "EMERGENCY STOP" WEATHERPROOF PUSHBUTTON SWITCH AT 5'-0" OUTSIDE OF THE ENCLOSURE. PROVIDE A <br />PHENOLIC RED NAMEPLATE WITH WHITE 1/2" HIGH LETTERS "EMERGENCY GENERATOR STOP". THIS STOP SWITCH IS EXISTING AS <br />PART OF THE RELOCATED GENERATOR. <br />14 HAND DIGGING SHALL BE DONE AT THE NEW GENERATOR AND FEEDER LOCATIONS. CALL "SAFE DIG' AND MARK ALL ITEMS <br />15 THE ENCLOSURE DOORS MUST CLEAR ANY OBSTRUCTION WHEN OPENED. PROVIDE POSITIVE LATCHES TO HOLD THE DOORS IN <br />THE OPEN 180 DEGREE POSITION FOR INSPECTION AND MAINTENANCE <br />16 MOUNT PANELS AND ELECTRICAL EQUIPMENT ON THE WALLS WITH 1" PVC COATED CHANNELS. DO NOT MOUNT DIRECTLY TO <br />THE CONCRETE WALL FREE STANDING EQUIPMENT SHALL BE BOLTED TO A NEW CONCRETE SLAB. UTILIZE STAINLESS STEEL <br />BOLTS NUTS AND WASHERS. <br />17 RECEPTACLE CONDUIT AT GENERATOR AND JUNCTION BOX COVERPLATES ON LIFE SAFETY CIRCUITS SHALL HAVE PAINTED YELLOW <br />BANDS. CONDUIT INSIDE THE NOA SHALL HAVE YELLOW BANDS FOR LIFE SAFETY AND ORANGE BANDS FOR CRITICAL. <br />18 ALL CONDUITS (ANNUNCIATOR, FEEDER AND CIRCUITS) SHALL RISE TO THE GENERATOR BASE WITHIN THE TANK BASE CUT OUT <br />AREA RUN IN SCHED 40 PVC. PROVIDE A FLEXIBLE SEALTIGHT CONNECTION TO THE GENERATOR BASE AND EXTEND WITHIN THE <br />GENERATOR HOUSING WITH FLEXIBLE SEALTIGHT CONDUIT. COORDINATE WITH THE MANUFACTURERS WIRING ARRANGEMENT AND <br />REQUIRED CUT OUT LOCATION. <br />19 THE RADIATOR EXHAUST END OF THE GENERATOR SHALL BE LOCATED ON THE SOUTH SIDE. THE CONTROL PANEL END SHALL <br />BE LOCATED ON THE NORTH SIDE. <br />20 PROVIDE 30 DAY RECORDED AMPERE READINGS FOR MDP AND PANEL A2 FEEDER PRIOR TO ATS NORMAL COORDINATE WITH <br />THE OWNER PRIOR TO SUBMITTING THE BID. INCLUDE THIS COST IN THE BID. THE OWNER MAY PROVIDE THIS INFORMATION. THE <br />RECORDED READING (AT 10 MINUTE INTERVALS) SHALL BE SUBMITTED TO THE PROJECT ENGINEER FOR ACCEPTANCE <br />21 CONDUIT FEEDERS, CIRCUITS ANNUNCIATOR CONDUIT AND START CIRCUIT ARE NEW. RUN BELOW GRADE IN A TRENCH PER <br />DETAIL ON E300 <br />22 PROVIDE A HEAVY DUTY CAST GRADE JB FOR CONNECTION TO THE EXISTING GENERATOR LIGHTING, RECEPTACLE, CHARGER <br />STARTING CIRCUIT AND HEATING CIRCUITS. <br />23 COORDINATE WITH UTILITY COMPANY TO PROVIDE THE NEW SECONDARY SERVICE TO MDP. REMOVE THE CONDUCTORS DURING <br />THE POWER SHUT DOWN AFTER THE INSTALLATION OF THE NEW SERVICE IS AS COMPLETE AS POSSIBLE. <br />24 PROVIDE A 3/4' CONDUIT FROM THE GENERATOR TO THE NEW ANNUNCIATOR AT THE NURSE STATION. LOCATE THE <br />ANNUNCIATOR WHERE DIRECTED BY THE OWNER'S PROJECT REPRESENTATIVE. UTILIZE THE EXISTING CONDUIT IF POSSIBLE AND <br />IF COMPLIANT. <br />25 REMOVE THE EXISTING 30 KW GENERATOR FEEDERS, CIRCUITS, ANNUNCIATOR AND ALL ELECTRICAL VERIFY EXISTING LOCATION <br />PRIOR TO BID. REFER TO PHASING PLAN <br />26 PROVIDE NEW NORMAL AND EMERGENCY FEEDERS FROM MDP1 AND THE GENERATOR TO THE EXISTING WIRING TROUGHS SWITCH. <br />REFER TO THE POWER ONE LINE DIAGRAM <br />w W <br />C � <br />� a <br />CO� U o WK <br />045z <br />5 Cl <br />Q N ON <br />�� Z m[Liw <br />m~� <br />.� O0 zZ <br />n, W <br />W p =3� <br />Z� Z NWz <br />vi a <br />�p J z�w <br />°aSO� ¢SoZ <br />W <br />w �- <br />Z � NWz <br />J a: <br />I <br />N�wo <br />W W <br />w CL3Wo <br />oZ Z o <br />O 0 CD <br />Q Z W <br />W z w <br />c= <br />r LA w <br />Z W N <br />� m O <br />P7 C) O <br />000 c z <br />Il_ W w >- <br />I waw <br />U ��o <br />ul <br />x <br />�•� <br />•. <br />dam- <br />�: tv <br />u_ Z <br />; o �:y= <br />W <br />LUv <br />w <br />REV <br />i►i►in <br />REV <br />REV 1n GENERAL REV. 02/13/18 <br />AHCA STAGE III MAIL -IN <br />REVIEW 12/26/17 <br />DATE 12/26/17 <br />DRAWN LF/BMA <br />CHKD BY BOB DONNELLY <br />E200 <br />
The URL can be used to link to this page
Your browser does not support the video tag.