HVAC CONTRACTOR NOTE: THIS DESIGN WAS CREATED FOR HEAT LOAD AND ENERGY CODE CALCULATION PURPOSES ONLY. INSTALLING HVAC CONTRACTOR MAY USE OR MODIFY THIS DESIGN AS NEEDED TO SATISFY THE PERMIT JURISDICTION - INTERPRETATION OF THE BUILDING CODES WILL VARY BY JURISDICTION AND PLANS EXAMINER DESPITE THE BUILDING CODES BEING "UNIFIED". ALL PERMIT COMMENTS MUST BE ADDRESSED BY THE INSTALLING HVAC CONTRACTOR. INSTALLING HVAC CONTRACTOR IS REQUIRED TO SIGN THE HVAC DRAWINGS AND CALCULATIONS FOR PERMITTING. INSTALLING HVAC CONTRACTOR HAS THE OPTION OF PROVIDING ALTERNATE HVAC DRAWINGS AND CALCULATIONS. <br />M Toilet <br />S22,4",25 CFM,Reg:8x4 <br />S43,4",20 CFM,Reg:8x4 <br />S6,4",11 CFM,Reg:8x4 <br />H. V. A. C. PLAN <br />SCREENED ROOF CAP FASTEN <br />TO STRUCTURE FOR UP <br />TO 200 MPH WIND MAX. <br />ENGINEERED FASTENING <br />DETAIL + MANUFACTURERS <br />INSTALLATION INSTRUCTIONS <br />ARE SUPPLIED ON SITE BY THE <br />INSTALLING CONTRACTOR <br />GENERAL EXHAUST DUCT <br />VENT TO EXTERIOR - WALL <br />OR ROOF - FMC 501,601,603 <br />SCREENED CAP - FASTEN <br />TO STRUCTURE FOR UP TO <br />2D0 MPH WIND MAX.ENGINEERED <br />FASTENING DETAIL+ MANUFACT- <br />URERS INSTALL INSTRUCTIONS <br />At <br />ARE SUPPLIED ON SITE BY THE <br />INSTALLING CONTRACTOR <br />J EXTERIOR SURFACE -WALL / SOFFIT <br />EXTERIOR ROOF SURFACE <br />M <br />CEILING EXHAUST <br />FAN VENTED TO <br />BUILDING EXTERIOR <br />FMC 501 <br />INTEGRAL <br />BACKDRAFT <br />DAMPER <br />EXHAUST FAN DETAIL @ ii <br />N.T.S <br />SCREENED ROOF CAP FASTEN <br />TO STRUCTURE FOR UP <br />TO 200 MPH WIND MAX. <br />ENGINEERED FASTENING <br />DETAIL + MANUFACTURERS <br />INSTALL INSTRUCTIONS ARE <br />SUPPLIED ON SITE BY THE <br />INSTALLING CONTRACTOR <br />FMC 401.5 <br />BUILDING VENTILATION AIR DUCT <br />TO EXTERIOR APPROVED LOCATION <br />FMC 401,403,601,603,604 <br />SCREENED CAP FASTEN <br />TO STRUCTURE FOR UP <br />TO 200 MPH WIND MAX. <br />ENGINEERED FASTENING <br />DETAIL + MANUFACTURERS <br />INSTALL INSTRUCTIONS ARE <br />SUPPLIED ON SITE BY THE <br />INSTALLING CONTRACTOR <br />FMC 401.5 <br />EXTERIOR SURFACE - WALL / SOFFIT <br />EXTERIOR ROOF SURFACE <br />VENTILATION AIR DUCT s <br />CONNECTS TO RETURN <br />AIR PLENUM DUCT + <br />HONEYWELL ARD 24V, <br />6VA MOTORIZED VENT- <br />ILATION AIR DAMPER <br />INTERLOCKED WITH <br />INDOOR AIR FAN MOTOR <br />SEE HVAC FLOOR PLAN <br />DRAWING FOR CONFIG. <br />FMC401,303,306 <br />VENTILATION AIR DETAIL @ il <br />N.T.S <br />UN -SCREENED ROOF CAP + BACK EXTERIOR ROOF SURFACE <br />DRAFT DAMPER, FASTEN TO <br />STRUCTURE FOR UP TO 200 MPH <br />WIND MAX. ENGINEERED FAST- <br />ENING DETAIL + MANUFACTURERS <br />INSTALLATION INSTRUCTIONS <br />ARE SUPPLIED ON SITE BY <br />THE INSTALLING CONTRACTOR <br />NOMINAL T' EXHAUST <br />DUCT VENTED TO <br />EXTERIOR - SEE FMC <br />505 FOR FULL <br />INSTALLATION <br />COMPLIANCE <br />UN -SCREENED CAP + <br />BACKDRAFT DAMPER, FASTEN <br />TO STRUCTURE FOR UP <br />TO 200 MPH WIND MAX. <br />ENGINEERED FASTENING <br />DETAIL + MANUFACTURERS <br />INSTALL INSTRUCTIONS ARE <br />SUPPLIED ON SITE <br />EXTERIOR SURFACE - WALL / SOFFIT <br />RANGE EXHAUST DETAIL <br />I DOMESTIC RANGE <br />HOOD (<FMC 400 <br />50 CF ) I <br />DOMESTIC RANGE <br />MAY ALSO BE DOWN <br />FLOW OR DUCTLESS <br />N.T.S <br />UN -SCREENED ROOF CAP + BACK <br />EXTERIOR ROOF SURFACE <br />DRAFT DAMPER, FASTEN TO <br />STRUCTURE FOR UP TO 200 MPH <br />WIND MAX.ENGINEERED FAST- <br />ENING DETAIL + MANUFACTURERS <br />INSTALLATION INSTRUCTIONS <br />ARE SUPPLIED ON SITE BY <br />THE INSTALLING CONTRACTOR <br />DOMESTIC <br />4" EXHAUST DUCT NOT TO EXCEED 35' <br />(< 200 CFM) <br />DEVELOPED LENGTH, SEE FMC 504 FOR <br />STYLE CLOTHES <br />FULL COMPLIANCE - VENT TO EXTERIOR <br />DRYER - FMC 504 <br />WALL OR ROOF, PROVIDE WALL BOX OR <br />DRYER INSTALLATION INSTRUCTIONS <br />FOR LENGTHS LONGER THAN 35 FEET <br />UN -SCREENED CAP + BACK <br />DRAFT DAMPER, FASTEN TO <br />STRUCTURE FOR UP TO 200 <br />MPH WIND MAX. ENGINEERED <br />FASTENING DETAIL + MFG <br />INSTALL INSTRUCTIONS ARE <br />SUPPLIED ON SITE BY THE <br />9SOFFIT <br />INSTALLING CONTRACTOR <br />FLEXIBLE TRANSITION <br />DUCT CONNECTION <br />EXTERIOR SURFACE -WALL <br />BY OTHERS - 8' MAX. <br />DRYER EXHAUST DETAIL <br />N.T.S <br />TYPICAL PIPE COVER <br />MAY MOUNT INTERIOR <br />FASTEN WITH #12, 1/2" <br />GALV. SCREW @ 2' O.C. <br />HIGH VOLTAGE <br />DISCONNECT <br />SWITCH <br />REFRIGERANT <br />PIPING+ CONTROL <br />WIRING FMC 305, <br />1107 - ROUTING <br />MAY VARY <br />4" THICK CONCRETE SLAB <br />OR CODE APPROVED EQUAL <br />FMC 303 + 304 <br />CONDENSING UNIT <br />FMC 303,304,306 <br />EXTERIOR I <br />BUILDING <br />WALL <br />EQUIPMENT TIE <br />DOWN - ENGINEERED <br />FASTENING DETAIL + <br />MFG. INSTALLATION <br />INSTRUCTIONS ARE <br />SUPPLIED ON SITE <br />BY INSTALL CONTR. <br />GRADE 3" BELOW SLAB <br />CONDENSER / SLAB DETAIL <br />N.T.S <br />RETURN AIR PLENUM MECHANICALLY <br />FASTEN TO EQUIPMENT FLANGE <br />FMC 601,602,603,604 <br />VENTILATION <br />AIR DUCT <br />FMC 401 - <br />SEE NOTE 2 <br />(2) WATER DETECTION <br />DEVICES FMC 307.2.3.1 <br />PRIMARY CONDENSATE <br />DRAIN LINE, ROUTE TO <br />(4) 3/8" THREADED ROD + 2" UNISTRUT CHANNEL <br />SUSPEND FROM TOP TRUSS CHORD OR APPROVED <br />STRUCTURE - ENGINEERED FASTENING DETAIL + <br />MFG INSTALLATION INSTRUCTIONS ARE SUPPLIED <br />ON SITE BY THE INSTALLING CONTRACTOR <br />4RRING <br />G + <br />05, 1107 <br />NG UNIT <br />04,306 <br />SUPPLY PLENUM <br />oMECHANICALLY <br />FASTEN TO <br />EQUIPMENT <br />FMC 601, 602, <br />603,604 <br />EXTERIOR,DISCHARGE HIGH r <br />12" FROM BUILDING FMC 307 VOLTAGE <br />DISCONNECT AUXILLARY DRAIN PAN + WATER <br />- SWITCH DETECTION DEVICE FMC 307.2.3 <br />AIR HANDLER MAY MOUNT IN ATTIC, GARAGE, OR EXPOSED IN SPACE <br />AIR HANDLER / HORIZONTAL DETAIL <br />N.T.S <br />TRI - BOX <br />REDUCER -BOX <br />SEE HVAC DRAWING <br />FOR BRANCH + TRUNK WIZ <br />DUCT SIZES 1 QTY. <br />H <br />ARROW <br />INDICATES <br />AIRFLOW <br />L W DIRECTION <br />DUCTBOARD TRUNK TO BRANCH JUNCTION BOX - CONSTRUCT, <br />SEAL AND SUSPEND FROM STRUCTURE FMC 601,602,603,604 <br />SEE httpsonergygovsltesprodfiles20l3l2f5cg5_duct_spittter box_boach.pdf <br />BOX <br />MARK <br />DIMENSIONS - INCHES <br />W <br />H <br />L <br />A <br />13 <br />13 <br />18 <br />B <br />17 <br />17 <br />18 <br />C <br />21 <br />21 <br />18 <br />H <br />W <br />* = CAP SIZE EQUALS OUTLET <br />TRUNK DUCT SIZE + 2" <br />MODIFY TO FIT STRUCTURE <br />BOX <br />MARK <br />DIMENSIONS - INCHES <br />W <br />H <br />L <br />W2 <br />D <br />13 <br />13 <br />1 18 <br />E <br />17 <br />17 <br />18 <br />F <br />21 <br />21 <br />18 <br />FLEX DUCT JUNCTION BOX DETAIL <br />N.T.S <br />INSTALL FLEX DUCT WITH 45 <br />DEGREE ELBOWS NEAR THE <br />TRUNK AND BOOT CONNECTIONS. <br />ALLOW W'MIN. STRAIGHT DUCT <br />AT BOOT AND TRUNK CONNEC - <br />TIONS. DUCT BENDS SHALL <br />MAINTAIN ACENTER LINE RADIUS <br />OF NOT LESS THAN ONE DUCT <br />DIAMETER. USE UL181 CLASS 1 <br />FMC 601, 603, 604 <br />SUPPLY / RETURN AIR <br />DUCT TRUNK OR FLEX <br />JUNCTION BOX CONSTRUCT, <br />SEAL, AND SUSPEND FROM <br />STRUCTURE FMC 601,603,604 <br />INSTALLING CONTRACTOR <br />MAY USE THIS SECONDARY <br />*OPTIONAL* <br />VOLUME DAMPER <br />PROVIDE ACCESS FOR <br />ADJUSTMENT FMC 603.18 <br />FASTEN REGISTER <br />OR GRILLE TO <br />REGISTER BOX. <br />CEILING REGISTER BOX <br />PROVIDE PRIMARY <br />FASTEN TO STRUCTURE <br />VOLUME DAMPER <br />WITH REGISTER BOX RAILS <br />+ ADJ. CURVED <br />MAY MOUNT FLOOR, WALL, <br />BLADES - FMC <br />OR CEILING STRUCTURE <br />MA <br />; #, ' AND AIR DEVICE TYPE MAY <br />M <br />MAYY MOUNT <br />VARY FROM SHOWN <br />it <br />FLOOR, WALL, <br />FMC 601,603,604 <br />OR CEILING <br />DUCTBOARD / FLEX DUCT DETAIL <br />O <br />N.T.S <br />CV) <br />0) <br />LC) <br />Q <br />R <br />O <br />r4') <br />Li <br />f— <br />X <br />Q <br />LL_ <br />� <br />� <br />Q <br />J <br />Q_ <br />c� <br />cr <br />N <br />I` <br />Q <br />C!1 <br />cn <br />Q <br />N <br />In <br />U} <br />ro <br />z <br />DO <br />W <br />z <br />C <br />� <br />C) <br />a_ <br />1� <br />Z <br />n <br />W <br />J <br />� <br />N <br />I I <br />J <br />C) <br />Z <br />W <br />< <br />n, <br />z <br />W <br />tD7=N: <br />C.T. D <br />SCALE: <br />1 /4" <br />CHECKED & APPROVED <br />SHEET 2 <br />