GENERAL STRIICTIIRAL NOTES' <br />THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE <br />DRAWINGS OF ALL OTHER DISCIPLINES AND THE SPECIFICATIONS. THE <br />CONTRACTOR SHALL VERIFY THE REQUIREMENTS OF OTHER TRADES AS TO <br />SLEEVES, CHASES, HANGERS, INSERTS, ANCHORS, HOLES, AND OTHER ITEMS TO <br />BE PLACED OR SET IN THE STRUCTURAL WORK. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL SAFETY <br />PRECAUTIONS AND OSHA REGULATIONS DURING WORK. THE ENGINEER WILL NOT <br />ADVISE ON NOR ISSUE DIRECTION AS TO SAFETY PRECAUTIONS AND PROGRAMS. <br />THE STRUCTURAL DRAWINGS REPRESENT THE FINISHED STRUCTURE AND DO <br />NOT INDICATE THE METHODS OR MEANS OF CONSTRUCTION. THE CONTRACTOR <br />SHALL PROVIDE ALL TEMPORARY GUYING AND BRACING REQUIRED TO ERECT AN <br />HOLD THE STRUCTURE IN PROPER ALIGNMENT UNTIL ALL STRUCTURAL WORK AN <br />CONNECTIONS HAVE BEEN COMPLETED. THE INVESTIGATION, DESIGN, SAFETY, <br />ADEQUACY, AND INSPECTION OF ERECTION BRACING, SHORING, TEMPORARY <br />SUPPORTS, ETC., IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. <br />THE ENGINEER SHALL NOT BE RESPONSIBLE FOR THE METHODS, TECHNIQUES <br />AND SEQUENCES OF PROCEDURES TO PERFORM THE WORK. THE SUPERVISION <br />OF THE WORK IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. <br />DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION, WHERE <br />CONDITIONS ARE NOT SPECIFICALLY SHOWN, SIMILAR DETAILS OF <br />CONSTRUCTION SHALL BE USED, SUBJECT TO APPROVAL BY THE ENGINEER. <br />LOADING APPLIES TO THE STRUCTURE DURING THE PROCESS OF CONSTRUCTION <br />SHALL NOT EXCEED THE SAFE LOAD- CARRYING CAPACITY OF THE STRUCTURE <br />MEMBERS. THE LIVE LOADING USED IN THE DESIGN OF THIS STRUCTURE ARE <br />INDICATED IN THE "DESIGN CRITERIA NOTES". DO NOT APPLY ANY CONSTRUCTIO <br />LOADS UNTIL THE STRUCTURAL FRAMING IS PROPERLY CONNECTED TOGETHER <br />AND UNTIL ALL TEMPORARY BRACING IS IN PLACE <br />G/C. BUILDER TO SUBMIT SHOP DRAWINGS, IN NO CASE SHALL REPRODUCTION <br />OF THE CONTRACT DRAWINGS BE USED AS SHOP DRAWINGS. AS A MINIMUM, <br />SUBMIT THE FOLLOWING FOR REVIEW: <br />A. CONCRETE MIX DESIGNS INCLUDING MASONRY GROUT. <br />B. MASONRY CONSTRUCTION MATERIAL CERTIFICATES. <br />C. MATERIAL TEST REPORTS FOR MASONRY UNIT STRENGTH fm. <br />D. REINFORCING STEEL SHOP DRAWINGS. <br />E. STRUCTURAL STEEL SHOP DRAWINGS <br />F. POST -TENSIONED SLAB -ON -GRADE SYSTEM SHOP DRAWINGS. (*) <br />G. PRE -CAST HOLLOW CORE SLABS. (*) <br />H. PRE-ENGINEERED WOOD TRUSS SYSTEM. (* SEE NOTES) <br />ITEMS MARKED (*) SHALL HAVE SHOP DRAWINGS AND CALCULATIONS SIGNED AND <br />SEALED BY A FLORIDA REGISTERED ENGINEER. <br />8. CONTRACTOR TO MAKE PROVISIONS OF WINDOW PROTECTION AGAINST FL <br />DEBRIS. METHOD TO BE APPROVED BY INSPECTOR AT C.O. INSPECTION. <br />19. SIGNED & SEALED FOR STRUCTURAL PORTION OF DRAWING ONLY <br />10. PLANS IN ACCORDANCE WITH FBC-2020 7TH EDITION FOR WIND LOADS & <br />PRESSURES AS NOTED IN DESIGN CRITERIA. <br />SLAP ON GRADE NOTES_ <br />PROVIDE CONCRETE SLABS OVER A MINIMUM 6 MIL POLYETHYLENE VAPOR <br />BARRIER, PROPERLY LAPPED AND TAPED. <br />WALKWAYS AND OTHER EXTERIOR SLABS ARE NOT INDICATED ON THE <br />STRUCTURAL DRAWINGS. SEE THE SITE PLAN AND ARCHITECTURAL DRAWINGS <br />FOR LOCATIONS, DIMENSIONS, ELEVATIONS, JOINTING DETAILS AND FINISH <br />DETAILS. PROVIDE 4" WALKS REINFORCED WITH 6X6 - WI.4XWI .4WWF UNLESS <br />OTHERWISE NOTED. <br />ALL CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF ACI 301, <br />"SPECIFICATION FOR STRUCTURAL CONCRETE BUILDINGS". GUIDE FOR <br />CONCRETE FLOOR AND SLAB CONSTRUCTION" ACI 302. HOT WEATHER <br />CONCRETING SHALL BE IN ACCORDANCE W/ ACI 306 <br />FLASHING SHALL COMPLY WITH R903.2 <br />UNDERLAYMENT SHALL COMPLY WITH SECTION R905.1.1 <br />VALLEYS SHALL COMPLY WITH R905.2.8.2 <br />DRIP EDGE SHALL COMPLY WITH R905.2.8.2 <br />PER FLORIDA BUILDING CODE 2020, 7th EDITION <br />PROPER ATTACHMENT OF SOFFITS PANELS TO RESIST <br />WIND LOADS, IN ACCORDANCE WITH R704.2.1/R702.2.2 <br />PER FLORIDA BUILDING CODE 2020, 7th EDITION <br />ASPHALT ROOF <br />SHINGLES ARE CLASSIFIED IN ACCORDANCE WITH <br />ASTM D7158-CLASS G OR H, OR ASTM D3181-CLASS F <br />IN ACCORDAN E WITH TABLE R905.2.6.1, FBC 7th <br />EDITION (2020) - RESIDENTIAL. <br />SEPARATION <br />FROM THE RESIDENCE AND ATTICS <br />NET Egg 7}{MA'T/E2R�IIAA{L�ypS M gpp�� p� <br />98UIR NTAAPPLIED TO THEUGARAGE SIDE <br />FROM HABITABLE ROOMS ABOVE THE GARAGE <br />BEARD SRTE4UTAj2N-T CH TYPE X GYPSUM <br />uTRUCTURE($1 SU _POaJRTIREGWFII�00R[�C,EILINS SE�$EMBLIES <br />ORTEQUIVAB!NUT 1/2-INCH GYPSUM BOARD <br />rGARAGESSEuDFFOORRLaaOttCrrAETERAD LESS THAN 3 FEET FROM A DWELLING <br />NIT ON SAME LOT <br />�nUIV EXTERALENTIOR W�l6j6I T A THINR10ARD THIS REA <br />0� <br />STFFI NOTFSo <br />ALL STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN <br />WITH THE "MANUAL OF STEEL CONSTRUCTION" OF THE RISC. <br />UNLESS OTHERWISE NOTED, ALL MATERIALS SHALL BE IN ACCORDANCE WITH THE <br />FOLLOWING ASTM SPECIFICATIONS: <br />MEMBER <br />HHS <br />STEEL PIPE <br />OTHER SHAPES/PLATES <br />CONNECTION BOLTS <br />TREADED RODS <br />ASTM <br />A500 (Grad B) <br />A53 (TYPE E, GR B) <br />A36 <br />325(Grad A) <br />307(Grad A) <br />A36 <br />MIN. STRENGTH <br />46 KSI <br />35 KSI <br />36 KSI <br />90 KSI <br />45 KSI <br />36 KSI <br />3. ALL CONNECTIONS SHALL BE SHEAR TYPE CONNECTIONS AND DESIGNED BY THE <br />FABRICATOR BASED ON THE AISC MANUAL PART 2 WITH REACTIONS FROM THE <br />"ALLOWABLE UNIFORM LOAD" TABLES UNLESS REACTIONS ARE SHOWN ON PLAN. SUBMIT <br />SHOP DRAWINGS AND CALCULATIONS SIGNED AND SEALED BY A PROFESSIONAL ENGINEE <br />4. ALL WELDING SHALL BE IN ACCORDANCE WITH AWS D1.1 AND AISC 14th EDITION SEC. 8. <br />USING E70XX ELECTRODES. UNLESS OTHERWISE NOTED, PROVIDE CONT. MIN. SIZED <br />FILLET WELDS PER AISC REQUIREMENTS. ALL WELDING SHALL BE DONE BY A CURRENTLY <br />CERTIFIED WELDER IN ACCORDANCE WITH "AWS". <br />5. HOLES IN STEEL FOR OTHER TRADES SHALL BE DRILLED OR PUNCHED AND DETAILED <br />ON THE SHOP DRAWINGS. ALL SLOTTED HOLES SHALL BE PROVIDE WITH SMOOTH EDGES. <br />BURNING OF HOLES AND TORCH CUTTING AT THE SITE IS NOT PERMITTED. <br />6. U.O.N. ALL STRUCTURAL STEEL SHALL BE SHOP PAINTED WITH ONE COAT OF TYPE I, <br />OXIDE PRIMER PAINT, SEE SPECIFICATIONS. IF APPLICABLE, VERIFY THAT PRIMER <br />COATINGS ARE COMPATIBLE WITH SPRAYED ON FIRE PROOFING. <br />7. COLUMNS, ANCHOR BOLTS BASE PLATES ETC. HAVE BEEN DESIGNED FOR THE FINAL <br />COMPLETED CONDITION AND HAVE NOT BEEN INVESTIGATED FOR POTENTIAL LOADING <br />ENCOUNTERED DURING STEEL ERECTION AND CONSTRUCTION. ANY INVESTIGATION OF <br />THE COLUMNS, ANCHOR BOLTS, BASE PLATES, ETC. FOR ADEQUACY DURING THE STEEL <br />ERECTION AND CONSTRUCTION PROCESS IS THE SOLE RESPONSIBILITY OF THE <br />CONTRACTOR. <br />8. UNLESS OTHERWISE NOTED, ALL STRUCTURAL STEEL PERMANENTLY EXPOSED TO THE <br />WEATHER, INCLUDING ALL BRICK SHELF ANGLES SHALL BE HOT -DIPPED GALVANIZED IN <br />ACCORDANCE WITH ASTM A153. <br />9. PROTECTION COATINGS DAMAGED DURING THE TRANSPORTING, ERECTING AND FIELD <br />WELDING PROCESSES SHALL BE REPAIRED IN THE FIELD TO MATCH THE SHOP APPLIED <br />COATING. <br />10. ALL REINFORCED STEEL SHALL CONFORM TO ACI 318-14. <br />MIN. REBAR YIELD STRENGTH: Fy = 60.000 PSI <br />THE BUILDING SHALL BE PREPARED AND TESTED IN ACCORDANCE WITH THE <br />RECOMMENDATIONS OF THE SOILS ENGINEER. <br />IF THE SITE PREPARATION REQUIREMENTS ARE NOT SPECIFIED BY A <br />GEOTECHNICAL REPORT THE FOLLOWING PROCEDURES SHOULD BE USED AS A <br />MINIMUM. <br />WITHIN AN AREA A MINIMUM OF 5 FEET BEYOND THE BUILDING LIMITS, EXCAVATE <br />MINIMUM OF 4" OF EXISTING SOIL. REMOVE ALL ORGANICS, PAVEMENT, ROOTS, <br />DEBRIS AND OTHERWISE UNSUITABLE MATERIAL. <br />THE SURFACE OF THE EXPOSED SUBGRADE SHALL BE INSPECTED FOR POCKETS <br />OF SOFT OR UNSUITABLE MATERIAL. EXCAVATE UNSUITABLE SOIL AS DIRECTED <br />BY THE GEOTECHNICAL ENGINEERITESTING AGENCY. <br />FILL ALL EXCAVATED AREAS WITH APPROVED CONTROLLED FILL. PLACE IN <br />LIFTS AND COMPACT TO A MINIMUM OF 95% OF THE MAXIMUM DRY DENSITY <br />ON THE MODIFIED PROCTOR TEST. <br />ALL CONTROLLED FILL MATERIAL SHALL BE A SELECT GRANULAR MATERIAL FREE <br />FROM ALL ORGANICS OR OTHERWISE DELETERIOUS MATERIAL. <br />PROVIDE FIELD DENSITY TESTS FOR EACH 2O00 P.S.F. OF BUILDING AREA FOR <br />EACH LIFT OF CONTROLLED FILL. <br />NOTM- <br />1. STAPLES NOT PERMrTTED <br />2. DRYWALL NAILS SHALL CONFORM TO ASTM C 5% <br />3. SIDING APPLIED TO 5W NET WOOD SHTG, ISW WOOD STRUCTURAL PANEL OR 11r PARTIICLEBOARD SHIM <br />4. CORROSION RESISTANT NAILS SPACED 8' O.C. AT EDGES 8 8' O.C. AT INTERMEDIATE SUPPORTS. <br />NAILS SHALL HAVE A MIN EDGE DISTANCE OF 3W <br />5. SIDING APPLIED TO STUDS SPACED 18' O.C. MAX. <br />8. SIDING APPLIED DIRECTLY TO STUDS SPACE W O.C. MAX. <br />7. USE ANNULAR OR SPIRAL THREAD NAILS FOR COMBINATION SUBFLOOR/UNDERLAYMENT (SINGLE FLOOR) <br />6. NAIL MUST BE OF SUFFICIENT LENGTH TO ACCOMMODATE THKMESS OF SIDING AND SHTG. IF USED, <br />AND ALLOW MIN. STUD PENETRATION OF 110 <br />9. FOR 1' WOOD STRUCTURAL PANELS,120 O.C. INTERMEDIATE NAILING SHALL BE PERMITTED. <br />TABLE R302.6 DWELLING -GARAGE SEPARATION <br />1. ROOF WOOD TRUSS SYSTEMS SHALL BE DESIGNED BY THE MANUFACTURER TO <br />SUPPORT THE FOLLOWING LOADS: <br />A. ROOF TRUSS GRAVITY LOADING CASE <br />TOP CHORD LOADING: <br />LIVE LOAD: 20 PSF (ON THE HORIZONTAL PROJECTION) <br />DEAD LOAD: 25 PSF (ON THE SURFACE AREA) FOR ASPHALT SHINGLES <br />35 PSI (ON SURFACE AREA) FOR CEMENT OR CLAY TILE <br />BOTTOM CHORD LOADING: <br />ATTIC LIVE LOAD: 10 PSF <br />ATTIC LIVE LOAD WITH STORAGE: 30 PSF <br />DEAD LOAD (FOR 11T CD GYPSUM):5 PSF FOR 1/2" CD GYPSUM <br />B. ROOF TRUSS WIND LOADING CASE <br />TRUSSES ARE TO BE DESIGNED FOR WIND LOADING AS SHOWN ON DESIGN <br />ANALYSIS, UPLIFT SHALL DEDUCT 2/3 OF DEAD LOADS. <br />2. WOOD TRUSSES SHALL BE DESIGNED BY THE MANUFACTURER IN ACCORDANCE <br />WITH THE APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE "NDS" NATIONAL <br />DESIGN SPECIFICATION FOR WOOD CONSTRUCTION ANSI/AF&PA AND THE NATIONAL <br />DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION <br />"ANSVTPI". <br />3. WOOD MATERIALS SHALL BE SOUTHERN PINE, DOUGLAS FIR OR LARCH AND SHA <br />BE KILN DRIED AND USED AT 19% MAXIMUM MOISTURE CONTENT. PROVIDE GRADE <br />NO.2 OR BETTER REQUIRED TO SATISFY STRESS REQUIREMENTS. <br />4. CONNECTOR PLATES SHALL BE NOT LESS THAN 0.036 INCHES (20 GAUGE) IN <br />COATED THICKNESS, SHALL MEET OR EXCEED ASTM A653 GRADE 33 OR HIGHER AND <br />SHALL BE HOT DIPPED GALVANIZED ACCORDING TO ASTM A-525 (COATING G60). <br />5. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY AND PERMANENT BRACING <br />AS REQUIRED FOR SAFE ERECTION AND PERFORMANCE OF THE TRUSS. THE <br />GUIDELINES SET FORTH BY THE TRUSS PLATE INSTITUTION PUBLICATION "HIB-91, <br />COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLING AND BRACING <br />METAL PLATE CONNECTED WOOD TRUSSES" SHALL BE A MINIMUM REQUIREMENT. <br />6. TRUSS MEMBERS AND COMPONENTS SHALL NOT BE CUT, NOTCHED, DRILLED NOR <br />OTHERWISE ALTERED IN ANY WAY WITHOUT THE WRITTEN APPROVAL OF THE TRUSS <br />MANUFACTURER'S ENGINEER. <br />7. SUBMIT COMPLETE SHOP DRAWING FOR ALL WOOD TRUSSES SHOWING MEMBER <br />SIZES, SPAN, DIMENSIONS, CHORD PITCH, LOADING AND REACTIONS. SHOP <br />DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER AND SHALL BEAR THE SEAL OF A <br />PROFESSIONAL ENGINEER REGISTERED IN FLORIDA. <br />8. IF THE NET UPLIFT FORCES SHOWN ON THE FINAL ENGINEERED TRUSS <br />CALCULATIONS ARE GREATER THAN THE CAPACITY OF THE SPECIFIED CONNECTC <br />THE CONTRACTOR SHALL SUPPLY CONNECTORS TO MEET THOSE UPLIFT FORCES <br />A MINIMUM. <br />TYPE MODEL# MANUFACTUREUPLIFT CAP. FASTENERS <br />A <br />H2.5A <br />SIMPSON <br />545# <br />10 - 8d <br />B <br />H5 <br />SIMPSON <br />455# <br />8 - 8d <br />C <br />H10S <br />SIMPSON <br />1010# <br />16 - 8"1 1/2" <br />D <br />H14 <br />SIMPSON <br />1350# <br />12 - 8dX 1 1/20 <br />13-8d <br />E <br />H10A 2 <br />SIMPSON <br />1080# <br />9- W 1 1/2" <br />F <br />LTS <br />SIMPSON <br />74M <br />12 -10d <br />G <br />MTS <br />SIMPSON <br />10" <br />14 -10d <br />H <br />SP1 <br />SIMPSON <br />585# <br />10 -10d <br />1 <br />SP2 <br />SIMPSON <br />1065# <br />12 -10d <br />J <br />DSP <br />SIMPSON <br />7&W <br />8 -10d <br />K <br />(1)FGTR <br />SIMPSON <br />5000# <br />18 SDS 114" X 3" <br />21 /20 X 5" TITEN <br />L <br />(2)FGTR <br />SIMPSON <br />9400# <br />36 SDS 1/40 X 3" <br />41/2" X 5" TITEN <br />M HETA20 SIMPSON 1810# 9 -10DX 1 1/20 <br />N HETA24 SIMPSON 1810# 9 -10DX 1 1/20 <br />NOTES: <br />USP CONNECTORS MAY BE SUBSTITUTED IF THEY MEET OR <br />EXCEED THE UPLIFT VALUES SHOWN. <br />CONNECTOR SCHEDULE TABLE IS BASED ON LATEST SIMPSON <br />CATALOG, FOR SP #2 <br />FLORIDA APPROVAL <br />10456.2 <br />10456.2 <br />10"6.5 <br />10446.5 <br />10"6.5 <br />10456.7 <br />13872.14 <br />10456.10 <br />10456.10 <br />10456.1 <br />11473.2 <br />11473.2 <br />11473.3 <br />11473.3 <br />R703.3.2Fasteners. <br />Exterior wall coverings shall be securely fastened with aluminum, ggalvanized <br />stainless steel or rust -preventative coated nails in accordance wlfh Table F 703.3(1) <br />or with other Approved corrosion -resistant fasteners in accordance with the wall <br />covering manuracturer <br />EXTERIOR COVERING R703 <br />R703.7 EXTERIOR PLASTER <br />INSTALLATION OF THESE MATERIALS SHALL BE IN COMPLIANCE WITH ASTM C926, ASTM C1063 AND THE <br />PROVISIONS OF THE CODE. <br />R703.7.1 LATH <br />LATH AND LATH ATTACHMENTS SHALL BE OF CORRISION-RESISTANT MATERIALS. EXPANDED METAL OR WOVEN <br />WIRE LATH SHALL BE ATTACHED WITH 1-1/2-INCH-LONG (38mm), 11 GAGE NAILS HAVING A 7/16-INCH (11.1 mm) <br />HEAD, OR 7/8-INCH LONG (22.2 mm), 16 GAGE STAPLES, SPACED NOT MORE THAN 6 INCHES (152 mm), OR <br />AS OTHERWISE APPROVED <br />R703.7.2 PLASTER <br />PLASTERING WITH PORTLAND CEMENT PLASTER SHALL BE NOT LESS THAN THREE COATS WHERE APPLIED OVER <br />METAL LATH OR WIRE LATH AND SHALL BE NOT LESS THAN TWO COATS WHERE APPLIED OVER MASONRY, <br />CONCRETE, PRESSURE -PRESERVATIVE TREATED WOOD, OR DECAY -RESISTANT WOOD AS SPECIFIED IN SECTION <br />R317.1 OR GYPSUM BACKING. IF THE PLASTER SURFACE IS COMPLETELY COVERED BY VENEER OR OTHER <br />FACING MATERIAL OR IS COMPLETELY CONCELAED, PLASTER APPLICATION NEED BE ONLY TWO COATS, PROVIDED <br />THE TOTAL THICKNESS IS AS SET FORTH IN TABLE R702.1(1) <br />R703.7.2.1 WEEP SCREEDS <br />A MINIMUM 0.019-INCH (0.5 mm) (NO. 26 GALVANIZED SHEET GAGE), CORRISION-RESISTANT WEEP SCREED OR <br />PLASTIC WEEP SCREED, WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3-1/2 INCHES (89 mm) SHALL BE <br />PROVIDED AT OR BELOW THE FOUNDATION PLATE LINE ON EXTERIOR STUD WALLS IN ACCORDANCE WITH ASTM <br />C926. THE WEEP SCREED SHALL BE PLACED NOT LESS THAN 4 INCHES (102 mm) ABOVE THE EARTH OR 2 <br />INCHES (51 mm) ABOVE PAVED AREAS AND SHALL BE OF A TYPE THAT WILL ALLOW TRAPPED WATER TO DRAIN <br />TO THE EXTERIOR OF THE BUILDING. THE WEATHER -RESISTANT BARRIER SHALL LAP THE ATTACHMENT FLANGE. <br />THE EXTERIOR LATH SHALL COVER AND TERMINATE ON THE ATTACHMENT FLANGE OF THE WEEP SCREED. <br />R703.7.3 WATER-RESISTANT BARRIERS <br />WATER-RESISTANT BARRIERS SHALL BE INSTALLED AS REQUIRED IN SEDCTION R703.2 AND, WHERE APPLIED OVER <br />WOOD -BASED SHEATHING, SHALL INCLUDE A WATER RESISTIVE VAPOR -PERMEABLE BARRIER WITH A PERFORMANCE <br />AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE INDIVIDUAL LAYERS SHALL BE INSTALLED <br />(INSTALLED IN ACCORDANCE WITH SECTION R703.4) INTENDED TO DRAIN TO THE WATER -RESISTIVE BARRIER IS <br />DIRECTLY BETWEEN THE LAYERS. <br />EXCEPTION: WHERE THE WATER-RESISTANT BARRIER THAT IS APPLIED OVER WOOD -BASED SHEATHING HAS A <br />WATER RESISTANCE EQUAL TO OR GREATER THAN THAT OF 60-MINUTE GRADE D PAPER AND IS SEPERATED <br />FROM THE STUCCO BY AN INTERVENING, SUBSTANTIALLY NON WATER- ABSORBING LAYER OR DESIGNED DRAINAGE <br />SPACE. <br />R703.7.4 APPLICATION <br />EACH COAT SHALL BE KEPT IN A MOIST CONDITION FOR AT LEAST 48 HOURS PRIOR TO APPLICATION OF THE <br />NEXT COAT. <br />EXCEPTION: APPLICATIONS INSTALLED IN ACCORDANCE WITH ASTM C926 INCLUDING THE REFERENCE IN ASTM <br />C926 SECTION 8 TO SECTION X1.4.2 OF THE APPENDIX. <br />R703.7.5 CURING <br />THE FINISH COAT FOR TWO -COAT CEMENT PLASTER NOT BE APPLIED SOONER THAN SEVEN DAYS AFTER <br />APPLICATION OF THE FIRST COAT. FOR THREE -COAT CEMENT PLASTER, THE SECOND COAT SHALL NOT BE <br />APPLIED SOONER THAN 48 HOURS AFTER APPLICATION OF THE FIRST COAT. THE FINISH COAT FOR THREE COAT <br />CEMENT PLASTER SHALL NOT BE APPLIED SOONER THAN SEVEN DAYS AFTER APPLICATION OF THE SECOND COAT. <br />EXCEPTION: APPLICATION INSTALLED IN ACCORDANCE WITH ASTM C926 INCLUDING THE REFERENCE IN ASTM <br />C926 SECTION 8 TO SECTION X1.4.2 OF THE APPENDIX. <br />STUCCO FINISH PER ASTM 926-C <br />7/8" THICK - 3 LAYERS (3/8" SCRATCH COAT, 3/8" <br />BROWN COAT, 1/8" FINISH COAT) OVER METAL <br />LATH FASTENED @ 6" O.C. VERT. INTO <br />FRAMING MEMBERS & 2 LAYERS MOISTURE <br />BARRIER. <br />PROVIDE WEED SCREED @ BOTTOM OF <br />FLANGE SET BELOW TOP OF FOUNDATION AND <br />PLATE LINE. <br />TABLE R905.2.6.1 CLASSIFICATION OF ASPHALT SHINGLES <br />Maximum Basic Wind Speed, Vult, <br />From Figure R301.2(4) <br />Vasd as determined in accordance <br />with Section R301.2.1.3 <br />ASTM D 158 <br />ASTMI D3161 <br />110 <br />85 <br />D GorH <br />DorF <br />116 <br />90 <br />D G or H <br />D or F <br />129 <br />100 <br />G or H <br />D or F <br />142 <br />110 <br />G or H <br />F <br />155 <br />1 120 <br />G or H <br />F <br />168 <br />130 <br />H <br />F <br />181 <br />140 <br />H <br />F <br />194 <br />150 <br />H <br />F <br />REQUIRED SAFETY GLAZING IN HAZARDOUS LOCATIONS <br />(RE: FBRC R308.4) <br />RNNDI 88CA3 HppUMAN IMPACT ILNO SDS INDIVIDUAL GLAZED <br />AZLELDPASEEgASSTM INCLUDINGEEQ LASS MIRROR <br />IR OF IN HAZARDOUS <br />6 CFR LOCATIONRT S <br />SUCH <br />THOSE <br />CATEGY OR <br />I Of� CATEGORY II AS INDICATED IN TABLE R308.3. <br />EST1E1XCEPLHO�N�S: yy���p GL UgE �N RE p <br />2. L8UVERGEDg�WINLLDOgWESACA�NND I�pEALEO�USIgEpSE SHIACLLOO��q�SPAND ,Ql�l�fl♦N F�SIS$ANT LOCATIONS SALL COMPANY WITH ANSI Z97.1-14 <br />R30THE HAZARDOUS IN SWINGING DOORSREXCEPTCJALOUSIESRDONUYS wL101CHAl10CNS FOR 30THE 2PURPOSE OF GLAZING: <br />2. GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SLIDING AND BIFOLD CLOSET DOOR <br />ASEMBLIES <br />3. GLAZING IN STORM DOORS <br />4. GLAZING IN ALL UNFRAMED SWINGING DOORS <br />5. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHROOMS, AND SHOWERS <br />GLAZING IN ANY PART OF A BUILDING WALL ENCLOSURE THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE <br />GLAZING IS LESS THAN 60 INCHES MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE <br />6. GLAZING, IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS <br />WITHIN 24-INCH ARC OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES <br />ABOVE THE FLOOR OR WALKING SURFACE <br />7. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE LOCATIONS DESCRIBED IN ITEMS 5 AND 6 <br />ABOVE, THAT MEETS ALL OF THE FOLLOWING CONDITIONS: <br />7.1 EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET. <br />7.2 BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR <br />7.3 TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR <br />7.4 ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORTIZONTALLY OF THE GLAZING <br />8. ALL GLAZING IN RAILINGS REGARDLESS OF AN AREA OR HEIGHT ABOVE WALKING SURFACE, INCLUDED ARE STRUCTUAL <br />BALUSTER PANELS AND NONSTRUCTURAL IN FILL -PANELS. <br />9. GLAZING IN WALLS AND FENCES ENCLOSING INDOOR OR OUTDOOR SWIMMING POOLS, HOT TUBS AND SPAS WHERE THE <br />BOTTOM EGDE OF THE GLAZING IS LESS THANK 50 INCHES ABOVE A WALKING SURFACE AND WITHIN 60 INCHES <br />HOR71ZONALLY OF THE WATER'S EDGE. THIS SHALL BE APPLY TO SINGLE GLAZING AND ALL PANELS IN MULTIPLE GLAZING. <br />10. GLAZING ADJACENT TO STAIRWAYS, LANDINGS, AND RAMPS WITHIN 36 INCHES HORTIZONALLY OF A WALKING <br />SURFACE WHEN THE EXPOSSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES ABOVE THE PLANE OF THE <br />ADJACENT WALKING SURFACE. <br />11. GLAZING ADJACENT TO STAIRWAYS WITHIN 60 INCHES HORTIZONALLY OF THE BOTTOM TREAD OF A STAIRWAY IN <br />ANY DIRECTION WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES ABOVE THE NOSE OF THE TREAD. <br />EXCEPTION: THE FOLLOWING PRODUCTS, MATERIALS AND USES ARE EXEMPT FROM THE ABOVE HAZARDOUS LOCATIONS: <br />1. OPENINGS IN DOORS THROUGH WHICH A 3-INCH SPHERE IS UNABLE TO PASS. <br />2. DECORATIVE GLASS IN ITEMS 1.6 OR 7. <br />3. GLAZING IN SECTION R308.4. ITEM 6. WHEN THERE IS AN INTERVENING WALL OR OTHER PERMANENT BARRIER BETWEEN THE <br />DOOR AND THE GLAZING. <br />4. GLAZING IN SECTION R308.4.2. ITEM 3, IN WALLS PERPENDICULAR RO THE PLANE OF THE DOOR IN A CLOSED POSITION OR <br />WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET OR STORAGE AREA 3 FEET OR LESS IN DEPTH. GLAZING IN <br />THESE APPLICATIONS SHALL COMPANY WITH SECTION R308.4, ITEM 2. <br />5. GLAZING IN SECTION R308.4.3, WHEN A PROTECTIVE BAR IS INSTALLED ON THESE ACCESSIBLE SIDE(S) OF THE GLAZSING 36 <br />INCHES f 2 INCHES ABOVE THE FLOOR. THE BAR DHALL BE CAPABLE OF WITHSTANDING A HORIZONTAL LOAD OF 50 POUNDS <br />PER LINEAR FOOT WITHOUT CONTACTING THE GLASS AND BE A MINIMUM OF 1-1/2 INCHES <br />6. OUTBOARD PANES IN INSULATING GLASS UNITS AND OTHE MULTIPLE GLAZED PANELS IN SECTION R308.4, ITEM 7, WHEN <br />THE BOTTOM EDGE OF THE GLASS IS 25 FEET OR MORE ABOVE GRADE, A ROOF, WALKING SURFACES, OR OTHER HORTIZONAL <br />(WITHIN 45 DEGREES OF HORTIZONTAL SURFACE ADJACENT TO THE GLASS EXTERIOR. <br />7. LOUVERED WINDOWS AND JALOUSIES COMPLYING WITH THE REQUIREMENTS OF SECTION R308.2 <br />8. MIRRORS AND OTHER GLASS PANELS MOUNTED OR HUNG ON A SURFACE THAT PROVIDES A CONTINUOUS BACKING SUPPORT. <br />9. SAFETY GLAZING IN SECTION R308.4 IS NOT REQUIRED WHERE: <br />9.1 THE SIDE OF STAIRWAY, LANDING OR RAMP HAS A GUARDRAIL OR HANDRAIL, INCLUDING BALUSTERS OR IN -FILL PANELS, <br />COMPLYING WITH THE PREVISIONS OF SECTION 1014 OF THE FLORIDA BUILDING CODE, BUILDING AND <br />9.2 THE PLANE OF THE GLASS IS GREATER THEN 18 INCHES FROM THE RAILING. <br />hereby certify that I have reviewed this plan and found it to be in <br />compliance with ASCE 7-16 and the Florida Building Code 2020 7th Edition <br />David W. Smith, P.E. #53608 <br />