I 1_ <br />THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE <br />DRAWINGS OF ALL OTHER DISCIPLINES AND THE SPECIFICATIONS. THE <br />CONTRACTOR SHALL VERIFY THE REQUIREMENTS OF OTHER TRADES AS TO <br />SLEEVES, CHASES, HANGERS, INSERTS, ANCHORS, HOLES, AND OTHER ITEMS TO <br />BE PLACED OR SET IN THE STRUCTURAL WORK. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL SAFETY <br />PRECAUTIONS AND OSHA REGULATIONS DURING WORK. THE ENGINEER WILL NOT <br />ADVISE ON NOR ISSUE DIRECTION AS TO SAFETY PRECAUTIONS AND PROGRAMS. <br />THE STRUCTURAL DRAWINGS REPRESENT THE FINISHED STRUCTURE AND DO <br />NOT INDICATE THE METHODS OR MEANS OF CONSTRUCTION. THE CONTRACTOR <br />SHALL PROVIDE ALL TEMPORARY GUYING AND BRACING REQUIRED TO ERECT AND <br />HOLD THE STRUCTURE IN PROPER ALIGNMENT UNTIL ALL STRUCTURAL WORK AND <br />CONNECTIONS HAVE BEEN COMPLETED. THE INVESTIGATION, DESIGN, SAFETY, <br />ADEQUACY, AND INSPECTION OF ERECTION BRACING, SHORING, TEMPORARY <br />SUPPORTS, ETC., IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. <br />THE ENGINEER SHALL NOT BE RESPONSIBLE FOR THE METHODS, TECHNIQUES <br />AND SEQUENCES OF PROCEDURES TO PERFORM THE WORK. THE SUPERVISION <br />OF THE WORK IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. <br />DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION, WHERE <br />CONDITIONS ARE NOT SPECIFICALLY SHOWN, SIMILAR DETAILS OF <br />CONSTRUCTION SHALL BE USED, SUBJECT TO APPROVAL BY THE ENGINEER. <br />LOADING APPLIES TO THE STRUCTURE DURING THE PROCESS OF CONSTRUCTION <br />SHALL NOT EXCEED THE SAFE LOAD- CARRYING CAPACITY OF THE STRUCTURE <br />MEMBERS. THE LIVE LOADING USED IN THE DESIGN OF THIS STRUCTURE ARE <br />INDICATED IN THE "DESIGN CRITERIA NOTES". DO NOT APPLY ANY CONSTRUCTION <br />LOADS UNTIL THE STRUCTURAL FRAMING IS PROPERLY CONNECTED TOGETHER <br />AND UNTIL ALL TEMPORARY BRACING IS IN PLACE <br />G/C. BUILDER TO SUBMIT SHOP DRAWINGS, IN NO CASE SHALL REPRODUCTION <br />OF THE CONTRACT DRAWINGS BE USED AS SHOP DRAWINGS. AS A MINIMUM, <br />SUBMIT THE FOLLOWING FOR REVIEW: <br />A. CONCRETE MIX DESIGNS INCLUDING MASONRY GROUT. <br />B. MASONRY CONSTRUCTION MATERIAL CERTIFICATES. <br />C. MATERIAL TEST REPORTS FOR MASONRY UNIT STRENGTH fm. <br />D. REINFORCING STEEL SHOP DRAWINGS. <br />E. STRUCTURAL STEEL SHOP DRAWINGS <br />F. POST -TENSIONED SLAB -ON -GRADE SYSTEM SHOP DRAWINGS. (*) <br />G. PRE -CAST HOLLOW CORE SLABS. (*) <br />H. PRE-ENGINEERED WOOD TRUSS SYSTEM. (* SEE NOTES) <br />ITEMS MARKED (*) SHALL HAVE SHOP DRAWINGS AND CALCULATIONS SIGNED AND <br />SEALED BY A FLORIDA REGISTERED ENGINEER. <br />8. CONTRACTOR TO MAKE PROVISIONS OF WINDOW PROTECTION AGAINST FLYING <br />DEBRIS. METHOD TO BE APPROVED BY INSPECTOR AT C.O. INSPECTION. <br />9. SIGNED & SEALED FOR STRUCTURAL PORTION OF DRAWING ONLY <br />10. PLANS IN ACCORDANCE WITH FBC-2020 7TH EDITION FOR WIND LOADS & <br />PRESSURES AS NOTED IN DESIGN CRITERIA. <br />1. STAPLES NOT PERMITTED <br />2. DRYWALL NAILS SHALL CONFORM TO ASTM C 514. <br />3. SIDING APPLIED TO 5/8" NET WOOD SHTG,15/32" WOOD STRUCTURAL PANEL OR 10 PARTICLEBOARD SHT <br />4. CORROSION RESISTANT NAILS SPACED 8" O.C. AT EDGES 818' O.C. AT INTERMEDIATE SUPPORTS. <br />NAILS SHALL HAVE A MIN EDGE DISTANCE OF 3/8" <br />5. SIDING APPLIED TO STUDS SPACED 18.O.C. MAX. <br />6. SIDING APPLIED DIRECTLY TO STUDS SPACE 24" O.C. MAX. <br />7. USE ANNULAR OR SPIRAL THREAD NAILS FOR COMBINATION SUBFLOOR UNDERLAYMENT (SINGLE FLOOR) <br />8. NAIL MUST BE OF SUFFICIENT LENGTH TO ACCOMMODATE THICKNESS OF SIDING AND SHTG. IF USED, <br />AND ALLOW MIN. STUD PENETRATION OF 11120 <br />9. FOR V WOOD STRUCTURAL PANELS,12" O.C. INTERMEDIATE NAILING SHALL BE PERMITTED. <br />TABLE R302.6 DWELLING -GARAGE SEPARATION <br />WOOD CONSTRUCTION, CONNECTIONS AND NAILING REQUIREMENTS SHALL CONFORM TO <br />THE 2020 FLORIDA BUILDING CODE. REFERENCE FASTENING SCHEDULE TABLE. <br />ALL WOOD FRAMING MATERIAL SHALL BE SURFACED DRY AND USED AT 19% MAXIMUM <br />MOISTURE CONTENT. <br />ALL LOAD BEARING WALL FRAMING SHALL BE NO.2 GRADE SOUTHERN PINE or SPF or P.T. <br />ALL JOIST AND RAFTER FRAMING SHALL BE NO.2 GRADE, SOUTHERN PINE OR HEM -FIR. <br />ALL FRAMING EXPOSED TO THE WEATHER OR IN CONTACT WITH MASONRY OR CONCRETE <br />SHALL BE PRESSURE -TREATED IN ACCORDANCE WITH THE AMERICAN WOOD PRESERVERS <br />ASSOCIATION SPECIFICATIONS. <br />BOLT HEADS SHALL BE CAREFULLY CENTERED AND DRILLED NOT MORE THAN 1/16" <br />LARGER THAN THE BOLT DIAMETER. BOLTED CONNECTIONS SHALL BE SNUGGED TIGHT <br />BUT NOT TO THE EXTENT OF CRUSHING WOOD UNDER WASHERS. <br />PREFABRICATED "MICRO -LAM" LUMBER HEADERS AND BEAMS SHALL AS MANUFACTURED <br />BY "TRUSS JOIST MacMILLIAN CORP." BOISE, IDAHO OR APPROVED EQUAL. <br />DO NOT CUT OR NOTCH MICRO -LAM MATERIAL WITHOUT THE MANUFACTURER'S APPROVAL. <br />8. PREFABRICATED METAL JOIST HANGERS, HURRICANE CLIPS, HOLD-DOWN ANCHORS AND <br />OTHER ACCESSORIES SHALL BE AS MANUFACTURED BY "SIMPSON STRONG TIE COMPANY", <br />OR EQUAL. INSTALL ALL ACCESSORIES AS PER THE MANUFACTURES REQUIREMENTS. ALL <br />STEEL SHALL HAVE A MINIMUM THICKNESS OF 0.04 INCHES (PER ASTM A446, GRADE A) AND <br />BE GALVANIZED (COATING G60). <br />►� �13����1'uM:I� <br />INTERIOR LOAD BEARING WALLS SPF #2 <br />ALL EXTERIOR FRAMING SPF #2 <br />ALL FRAME WALLS TO BE CONSTRUCTED USING SPF #2, STUD QUALITY OR BETTER <br />ALL HEADER, BEAMS, COLUMNS ETC, TO BE SYP #2 OR BETTER <br />ALL PLYWOOD USED FOR EXTERIOR APPLICATIONS SHALL BE APA RATED STRUCTURAL <br />SHEATHING 15/32' EXP 1 OR 7/16' STRUCTURAL 1, U.N.O. <br />ALL PLYWOOD USED FOR INTERIOR APPLICATIONS SUCH AS SUB FLOORING AND <br />SHEAR WALLS SHALL BE APA RATED SHEATHING EXP 1 U.N.O. <br />IF ❑SB BOARD IS TO BE USED IN PLACE OF PLYWOOD IS TO HAVE SIMILAR OR <br />GREATER SECTION PROPERTIES. <br />ONLY STRUCTURAL LUMBER TO BE USED FOR AN EXTERIOR APPLICATION, WOOD IN <br />CONTACT WITH CONCRETE IS TO RECEIVE A STANDARD GRADE PRESSURE TREATING. <br />WHEN PRE ENGINEERED TRUSSES ARE CALLED FOR ON THE PLANS THE <br />MANUFACTURER IS TO SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD. <br />DESIGN, FABRICATE AND ERECT WOOD TRUSSES IN ACCORDANCE WITH THE "DESIGN <br />SPECIFICATION FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES" BY THE <br />ANSI/TPI 1-2007 BCSI <br />UNTREATED W❑❑b SHALL NOT BE IN DIRECT CONTACT WITH C❑NCRETE, SEAT PLATES <br />SHALL BE PROVIDED AT BEARING L❑CATIONS WITHOUT WOODEN TOP PLATES, <br />ALL EXTERIOR FRAME WALLS SHALL BE STUCCO FINISH- 7/8' STUCCO FINISH PER <br />ASTM C, 926, APPLY 3 LAYERS W/ TOTAL THICKNESS 7/8' OVER METAL LATH, FIRST <br />2 LAYERS 3/8' THICK EACH, 3RD LAYER 1/8' THICK <br />INSTALLATION OF EXTERIOR LATHING & FRAMING SHALL COMPLY TO ASTM C 1063 <br />PER FLORIDA CODE R703.7 <br />FASTENERS AND TIE DOWNS <br />FASTENERS AND TIE DOWNS SHALL CONSIST OF BUT ARE NOT LIMITED TO <br />SHAPES, ANGLES, CHANNELS ; ASTM A36/36M 05 F = 36 Ks! <br />ROUND METAL PIPE : ASTM A53, GRADE B Fy, = 35y Ks! <br />SQUARE METAL TUBING ASTM A500, GRADE B Fy = 46Ksi <br />HIGH STRENGTH BOLTS ASTM A325 <br />MACHINE BOLTS : GALVANIZED ASTM A307 <br />SHEET METAL ACCESSORIES SHALL CONFORM TO : Fy = 33KsiWITH G90 <br />GALVANIZED C❑ATING IN ACCORDANCE WITH ASTM A525-87. <br />NAILS SHALL CONSIST OF : COMMON WIRE NAILS WITH MINIMUM DIAMETER AS <br />FOLLOWS : 8d = 0.131', 10d = 0.148', 12d = 0.148', 16d = 0.162 <br />ALL FASTENERS AND TIE DOWNS EMBEDDED IN CONCRETE OR USED IN AN EXTERIOR <br />APPLICATION ARE TO RECEIVE AN ANTI -CORROSIVE C❑ATING BY MANUFACTURER <br />PRIOR TO INSTALLATION. <br />ALL FASTENERS AND TIE DOWNS ARE TO PROVIDE THE UPLIFT CAPACITY CALLED <br />FOR IN THE PLANS ARE A MINIMUM. <br />ALL FASTENER TIE DOWNS, BEAM HANGERS, J❑IST HANGERS, AND FLOOR TRUSS <br />STRAPPING ARE TO BE INSTALLED IN ACCORDANCE WITH THE PLANS AND <br />SPECIFICATIONS. <br />CONCRETE EMBEDDED 'J' BOLTS USED FOR UPLIFT ARE TO BE WET SET PRIOR TO <br />INITIAL SET OF THE CONCRETE, SPACING AND ALIGNMENT ARE TO BE IN ACCORDANCE <br />WITH THE DESIGN PLANS, U.N,D, ALTERNATES TO "J' BOLTS ARE NOTED ON PLANS. <br />CONCRETE EMBEDDED TIE DOWNS USED FOR TRUSS AND WALL UPLIFT ARE TO BE <br />PLACED AROUND EMBEDDED REINFORCING PRIOR TO OR WHILE PLACING GROUT. <br />NOTE: <br />GYPSUM BOARD MAY BE INSTALLED USING GWB54 NAILS TO SET IN PLACE. FIELD <br />FASTENING SHOULD BE TYPE "W' 11/4" DRYWALL SCREWS AT 12" D.C. FOR CEILINGS AND 1 <br />DRYWALL SCREWS AT 12" D.C. FOR WALLS, ALL ENDS AND EDGES OF WALLBA❑RD SHALL <br />OCCUR OVER AND BE SCREWED TO SUPPORTS, MAXIMUM SCREW SPACING AT ENDS <br />(EDGES IN VERTICAL APPLICATION) SHALL BE 6' D.C. AT EACH SUPPORT, MINIMUM SCREW / <br />NAIL DISTANCE FROM EDGE SHALL BE ' THIS SHALL APPLY TO BOTH CEILING AND WALL <br />INSTALLATION, DRYWALL SHIMS SHALL BE USED ONLY WHERE NECESSARY, OPENINGS <br />CUT FOR OUTLETS, SWITCHES, ETC, SHALL BE OF A TOLERANCE THAT CAN BE COVERED <br />ADEQUATELY WITH NORMAL SWITCH PLATES AND COVERS WITH❑UT ADDITIONAL TAPING <br />OR CAULKING. DRYWALL SHALL NOT BE INSTALLED WITHOUT PROPER BACKING, <br />NOTE: <br />ALL HEADERS, BEAMS, ETC ARE TO BE SYP #2 OR BETTER AND OR MICROLAM <br />AS INDICATED ON THE DRAWINGS AND CAN NOT BE REVISED. <br />MASONRY INSTALLATION - WINDOWS <br />BUCKSTRIPS SHOULD BE PLACED AND SET IN A BEAD OF SEALANT. SEAL THE EXTERIOR JOINT BETWEEN THE MASONRY AND THE <br />BUCKSTRIP. ALL GAPS ARE TO BE SEALED. BUCKSTRIPS WILL RUN THE ENTIRE LENGTH OF THE WINDOW OPENING. IF THE SILL IS <br />PRE -CAST, A BUCKSTRIP IS NOT REQUIRED. BUCKSTRIPS ARE TO BE MADE OF PRESSURE TREATED SPRUCE, YELLOW PINE, OR <br />COMPARABLE LUMBER. UNDER FLORIDA BUILDING CODE, A BEVEL OR TAPER LOCATED ON THE BUCK IS PERMITTED IF THE WINDOW <br />FRAME IS COMPLETELY SUPPORTED AT BOTH THE INTERIOR AND EXTERIOR BY THE BUCKSTRIP. <br />3/4" THICK WOOD BUCKSTRIPS : <br />FASTENERS FOR INSTALLATION WILL BE MASONRY SCREWS (MINIMUM 3/16" X 2 3/4"), INSTALLED THROUGH THE BUCKSTRIP AND <br />WINDOW INTO THE MASONRY. WINDOW MAY BE SHIMMED AS NECESSARY PROVIDED A SCREW EMBEDMENT (MINIMUM 1 1/4") IS <br />MAINTAINED IN THE MASONRY. FASTENERS WILL BE LOCATED A MAXIMUM OF 4" FROM EACH CORNER AND A MAXIMUM OF 18" O.C. <br />THEREAFTER IT IS RECOMMENDED NOT TO INSTALL FASTENERS THROUGH THE SILL OF THE WINDOW. BUCKSTRIPS SHOULD MEASURE <br />NO LESS THAN 3/4" X 2 1/8". <br />1 1/2" THICK (OR GREATER) WOOD BUCKSTRIPS (NOT SHOWN) : <br />WINDOW FASTENERS FOR INSTALLATION SHOULD BE A MINIMUM #10 X 1 1/2" WOOD SCREWS, INSTALLED INTO THE BUCKSTRIP <br />THROUGH THE WINDOW. WINDOW MAY BE SHIMMED AS NECESSARY PROVIDED A SCREW EMBEDMENT (OF MINIMUM 1 1/4") IS <br />MAINTAINED IN THE BUCKSTRIP. FASTENERS SHOULD BE LOCATED A MAXIMUM OF 4" FROM EACH CORNER AND A MAXIMUM OF 18" <br />O.C. IT IS RECOMMENDED NOT TO INSTALL FASTENERS THROUGH THE SILL OF THE WINDOW. BUCKSTRIPS SHOULD BE NO LESS THAN <br />1 1/2' X 2 1 /8". TO MAINTAIN A 1 1 /4" EMBEDMENT, BUCKSTRIPS SHOULD BE INSTALLED USING MINIMUM 3/16" X 2 3/4" <br />MASONRY SCREWS AND BE 18" O.C. THEREAFTER. <br />FRAME INSTALLATION - WINDOWS <br />INSTALLATION FASTENERS FOR WINDOWS ARE TO BE A 1 1/2" (MINIMUM), 4D NAILS OR #6 X 1 1/2" DRYWALL SCREW, WITH AN <br />EMBEDMENT OF 1 1/2" (MINIMUM). FASTENERS SHOULD BE LOCATED AT A MAXIMUM OF 4" FROM EACH CORNER AND 18" O.C. <br />THEREAFTER FOR SCREWS AND 9" O.C. FOR NAILS. IT IS RECOMMENDED FOR ALL SCREWS AND/OR NAILS TO BE SEALED, <br />PREVENTING INTRODUCTION OF WATER AND AIR. PRODUCT MAY BE SHIMMED AS NECESSARY. <br />ATTACH WINDOW AND DOOR FRAMES TO BLOCK WALL <br />WITH TAPC❑N SCREWS SPACED AT WINDOE/DOOR <br />MANUFACTURERS SPEC'S (TAPCONS MUST PENETRATE <br />THROUGH BUCKSTRIPS AND INTO BLOCK 1-1/4' MIN.) <br />4' P,T, BUCKSTRIP <br />TACHED TO BLOCK <br />TH 0.097' X 1-3/8' <br />NAILS SPACED AT <br />D.C. MAXIMUM <br />'ONRY BLOCK <br />NOTE, WINDOWS AND DOORS MUST BE INSTALLED SUCH <br />THAT THE MINIMUM GAP BETWEEN THE FRAM AND <br />BUCKSTRIPS IS 1/2'.L IF THICKER BUCKSTRIP MATERIAL <br />IS NEEDED RIP IT FROM 1-1/2' MATERIAL AND ATTACH <br />TO BLOCK WITH 3/16' TAPC❑NS AT 8' ❑,C. (TAPCON MUST <br />PENETRATE BLOCK 1-1/4' MINIMUM) <br />WINDOW BUCKSTRIP DETAIL DOOR BUCKSTRIP DETAIL <br />NOT TO SCALE NOT TO SCALE <br />2020 FBC RESIDENTIAL SECTION R703,4 FLASHING <br />APPROVED C❑RRISION RESISTANT FLASHING SHALL BE APPLIED SHINGLE FASHION IN A MANNER TO PREVENT ENTRY <br />OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURE FRAMING COMPONENTS. <br />SELF ADHERED MENBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. ALL EXTERIOR FENESTRATION <br />PRODUCTS SHALL BE SEALED AT THE JUNCTION WITH THE BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA <br />800 OR ASTM C920 CLASS 25 GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION. ASTM <br />C 1281 AAMA 812 OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE TYPE OF SEALANT, FLUID APPLIED <br />MEMBRANES USED AS FLASHING IN EXTERIOR WALLS SHALL COMPLY WITH AAMA 714, THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED C❑RR❑SI❑N RESISTANT FLASHINGS SHALL BE INSTALLED AT <br />THE FOLLOWING L❑CATIONS. <br />1, EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALLd FINISH OR TO THE WATER RESISTANT BARRIER C❑MPLYING WITH SECTION <br />703.2 FOR SUBSEQUENT DRAINAGE. MECHANICALLY ATTACHED FLEXIBLE FLASHINGS SHALL COMPLY WITH AAMA <br />712. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR <br />MORE OF THE FOLLOWING. <br />1.1 THE FENESTRATION MANUFACTURERS INSTALLATION AND FLASHING INSTRUCTIONS OR THE APPLICATIONS <br />NOT ADDRESSED IN THE FENESTRATION MANUFACTURERS INSTRUCTIONS IN ACCORDANCE WITH THE <br />FLASHING MANUFACTURERS INSTRUCTIONS. WHERE FLASHING INSTRUCTIONS OR DETAILS ARE NOT <br />PA❑NVFLLASSHING SHALL IBE SHALL BE <br />SLOPED IINASUCHEASMAN � R AST TOI❑DIRECTD WATERD TO❑� DOOR <br />SURFACE <br />OF THE EXTERIOR WALL FINISH OR TO THE WATER RESISTANT BARRIER FOR SUBSEQUENT DRAINAGE <br />OPENINGS USING PAN FLASHING SHALL BE INCORP❑RATE FLASHING OR PROTECTION AT THE HEAD AND SIDES <br />MORE OF THE FOLL❑WING, <br />1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A REGISTERED DESIGN PR❑FESSI❑NAL <br />1.3 IN ACCORDANCE WITH OTHER APPROVED METHODS <br />1.4 IN ACCORDANCE WITH FMA/AMMA 100 FMA/AAMA 200 FMA/WDMA 250 FMA/AMMA/WDMA 300 <br />OR FMA/AAMA/WDMA 400 <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS WITH <br />PROJECTING LIPS ON BOTH SIDES UNDER STUCCO C❑PINGS <br />3. UNDER AND AT THE ENDS OF MASONRY WOOD OR METAL C❑PINGS AND SILLS <br />4, CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM <br />5. WHERE EXTERIOR PORCHES, DECKS AND STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD FRAME CONSTRUCTION <br />6. AT WALL AND ROOF INTERSECTIONS <br />7. AT BUILT-IN GUTTERS <br />EXTERIOR COVERING R703 <br />R703,7 EXTERIOR PLASTER <br />INSTALLATION OF THESE MATERIALS SHALL BE IN COMPLIANCE WITH ASTM C926, ASTM C1063 AND THE <br />PROVISIONS OF THE CODE, <br />R703.7.1 LATH <br />LATH AND LATH ATTACHMENTS SHALL BE OF CORRISION-RESISTANT MATERIALS, EXPANDED METAL OR WOVEN <br />WIRE LATH SHALL BE ATTACHED WITH 1-1/2-INCH-LONG (38mm), 11 GAGE NAILS HAVING A 7/16-INCH (11.1 mm) <br />HEAD, OR 7/8-INCH LONG (22.2 mm), 16 GAGE STAPLES, SPACED NOT MORE THAN 6 INCHES (152 mm), OR <br />AS OTHERWISE APPROVED <br />R703.72 PLASTER <br />PLASTERING WITH PORTLAND CEMENT PLASTER SHALL BE NOT LESS THAN THREE COATS WHERE APPLIED OVER <br />METAL LATH OR WIRE LATH AND SHALL BE NOT LESS THAN TWO COATS WHERE APPLIED OVER MASONRY, <br />CONCRETE, PRESSURE -PRESERVATIVE TREATED WOOD, OR DECAY -RESISTANT WOOD AS SPECIFIED IN SECTION <br />R317.1 OR GYPSUM BACKING. IF THE PLASTER SURFACE IS COMPLETELY COVERED BY VENEER OR OTHER <br />FACING MATERIAL OR IS COMPLETELY CONCELAED, PLASTER APPLICATION NEED BE ONLY TWO COATS, PR❑VIDED <br />THE TOTAL THICKNESS IS AS SET FORTH IN TABLE R702.1(1) <br />R7033.21 WEEP SCREEDS <br />A MINIMUM 0.019-INCH (0.5 mm) (NO. 26 GALVANIZED SHEET GAGE), CORRISION-RESISTANT WEEP SCREED OR <br />PLASTIC WEEP SCREED, WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3-1/2 INCHES (89 mm) SHALL BE <br />PR❑VIDED AT OR BELOW THE FOUNDATION PLATE LINE ON EXTERIOR STUD WALLS IN ACCORDANCE WITH ASTM <br />C926. THE WEEP SCREED SHALL BE PLACED NOT LESS THAN 4 INCHES (102 mm) ABOVE THE EARTH OR 2 <br />INCHES (51 mm) ABOVE PAVED AREAS AND SHALL BE OF A TYPE THAT WILL ALLOW TRAPPED WATER TO DRAIN <br />TO THE EXTERIOR OF THE BUILDING. THE WEATHER -RESISTANT BARRIER SHALL LAP THE ATTACHMENT FLANGE, <br />THE EXTERIOR LATH SHALL COVER AND TERMINATE ON THE ATTACHMENT FLANGE OF THE WEEP SCREED, <br />R703.7.3 WATER-RESISTANT BARRIERS <br />WATER-RESISTANT BARRIERS SHALL BE INSTALLED AS REQUIRED IN SEDCTION R703,2 AND, WHERE APPLIED OVER <br />WOOD -BASED SHEATHING, SHALL INCLUDE A WATER RESISTIVE VAPOR -PERMEABLE BARRIER WITH A PERFORMANCE <br />AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER, THE INDIVIDUAL LAYERS SHALL BE INSTALLED <br />(INSTALLED IN ACCORDANCE WITH SECTION R703.4) INTENDED TO DRAIN TO THE WATER -RESISTIVE BARRIER IS <br />DIRECTLY BETWEEN THE LAYERS. <br />EXCEPTION: WHERE THE WATER-RESISTANT BARRIER THAT IS APPLIED OVER WOOD -BASED SHEATHING HAS A <br />WATER RESISTANCE EQUAL TO OR GREATER THAN THAT OF 60-MINUTE GRADE D PAPER AND IS SEPERATED <br />FROM THE STUCCO BY AN INTERVENING, SUBSTANTIALLY NONWATER-ABSORBING LAYER OR DESIGNED DRAINAGE <br />SPACE. <br />R703.7.4 APPLICATION <br />EACH COAT SHALL BE KEPT IN A M❑IST CONDITION FOR AT LEAST 48 HOURS PRIOR TO APPLICATION OF THE <br />NEXT COAT. <br />EXCEPTION: APPLICATIONS INSTALLED IN ACCORDANCE WITH ASTM C926 INCLUDING THE REFERENCE IN ASTM <br />C926 SECTION 8 TO SECTION X1.4.2 OF THE APPENDIX. <br />R703.7,5 CURING <br />THE FINISH COAT FOR TWO -COAT CEMENT PLASTER NOT BE APPLIED SOONER THAN SEVEN DAYS AFTER <br />APPLICATION OF THE FIRST COAT. FOR THREE -COAT CEMENT PLASTER, THE SECOND COAT SHALL NOT BE <br />APPLIED SOONER THAN 48 HOURS AFTER APPLICATION OF THE FIRST COAT, THE FINISH COAT FOR THREE COAT <br />CEMENT PLASTER SHALL NOT BE APPLIED SOONER THAN SEVEN DAYS AFTER APPLICATION OF THE SECOND COAT. <br />EXCEPTION: APPLICATION INSTALLED IN ACCORDANCE WITH ASTM C926 INCLUDING THE REFERENCE IN ASTM <br />C926 SECTION 8 TO SECTION X1A,2 OF THE APPENDIX, <br />STUCCO FINISH PER ASTM 926-C <br />7/8" THICK - 3 LAYERS (3/8" SCRATCH COAT, 3/8" <br />BROWN COAT, 1/8" FINISH COAT) OVER METAL <br />LATH FASTENED @ 6" O.C. VERT. INTO <br />FRAMING MEMBERS & 2 LAYERS MOISTURE <br />BARRIER. <br />PROVIDE WEED SCREED @ BOTTOM OF <br />FLANGE SET BELOW TOP OF FOUNDATION AND <br />PLATE LINE. <br />SEPARATION <br />MATERIAL <br />FROM THE RESIDENCE AND ATTICS <br />NOT LESS THAN 1/2-INCH GYPSUM BOARD OR <br />EQUIVALENT THE GARAGE SIDE <br />FROM HABITABLE ROOMS ABOVE THE GARAGE <br />THAPPLIED NV <br />D8IRDEUR ERBIVACENT CH TYPE X GYPSUM <br />USEDCFORESEPERATIONTREQUIRED BY THIS ASSEMBLIES <br />NOT <br />TEQUIVALENTN 1/2-INCH GYPSUM BOARD <br />GARAGES LOCATED LESS THAN 3 FEET FROM A DWELLING <br />NOT LESS THAN 1/2-INCH GYPSUM BOARD OR <br />UNIT ON SAME LOT <br />EQUIVALENT APPLIED TO THE INTERIOR SIDE <br />IF EXTERIOR WALLS THAT ARE WITHIN THIS AREA <br />REQUIRED SAFETY GLAZING IN HAZARDOUS L❑CATIONS <br />(RE: FBRC R308,4) <br />IRND08,A THEEDMAANS IMPACT EDLI❑NDSS�CTID�INVIRD3UOAJ.4GSHAALELD AREASlTIHECTESIT REQUIREMENTS❑ OFNCPSCA 6 ❑CFR,LPARTI❑1201 SUCH AS <br />CATEGORY I OR CATEGORY II AS INDICATED IN TABLE R308,3.1 <br />1E1��XCpELPTIOENDSi ED �� g E I �R q ❑THE FIRE IS /� <br />2, L❑UEREDWWINDOWSA AND JALOUSIES SHALL ❑C❑MPANY WITH SECTION R308.2NT LOCATIONS SALL COMPANY WITH ANSI Z97.1-14 <br />R308.4 HAZARDOUS LOCATIONS. <br />p SI E IC H Z <br />THE 1F GLAZINGGIN SWINGING N DIR�D PT (JAL❑USIESRD❑US L❑CATIONS FOR THE PURPOSE OF GLAZING <br />2, GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SLIDING AND BIFOLD CLOSET DOOR <br />ASEMBLIES <br />3. GLAZING IN STORM DOORS <br />4, GLAZING IN ALL UNFRAMED SWINGING DOORS <br />5. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHROOMS, AND SHOWERS <br />GLAZING IN ANY PART OF A BUILDING WALL ENCLOSURE THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE <br />GLAZING IS LESS THAN 60 INCHES MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE <br />6, GLAZING, IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS <br />WITHIN 24-INCH ARC OF THE DOOR IN A CLOSED P❑SITI❑N AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES <br />ABOVE THE FLOOR OR WALKING SURFACE <br />7. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE L❑CATIONS DESCRIBED IN ITEMS 5 AND 6 <br />ABOVE, THAT MEETS ALL OF THE FOLLOWING CONDITIONS: <br />7.1 EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET, <br />7.2 BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR <br />7.3 TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR <br />7.4 ONE OR MORE WALKING SURFACES WITHIN 36 INCHES H❑RTIZONTALLY OF THE GLAZING <br />8. ALL GLAZING IN RAILINGS REGARDLESS OF AN AREA OR HEIGHT ABOVE WALKING SURFACE, INCLUDED ARE STRUCTUAL <br />BALUSTER PANELS AND NONSTRUCTURAL IN FILL -PANELS, <br />9. GLAZING IN WALLS AND FENCES ENCLOSING IND❑❑R OR OUTDOOR SWIMMING POOLS, HOT TUBS AND SPAS WHERE THE <br />BOTTOM EGDE OF THE GLAZING IS LESS THANK 50 INCHES ABOVE A WALKING SURFACE AND WITHIN 60 INCHES <br />H❑RTIZ❑NALLY OF THE WATER'S EDGE. THIS SHALL BE APPLY TO SINGLE GLAZING AND ALL PANELS IN MULTIPLE GLAZING. <br />10. GLAZING ADJACENT TO STAIRWAYS, LANDINGS, AND RAMPS WITHIN 36 INCHES HORTIZONALLY OF A WALKING <br />SURFACE WHEN THE EXPOSSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES ABOVE THE PLANE OF THE <br />ADJACENT WALKING SURFACE, <br />11, GLAZING ADJACENT TO STAIRWAYS WITHIN 60 INCHES H❑RTIZ❑NALLY OF THE BOTTOM TREAD OF A STAIRWAY IN <br />ANY DIRECTION WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES ABOVE THE NOSE OF THE TREAD, <br />EXCEPTION, THE FOLLOWING PRODUCTS, MATERIALS AND USES ARE EXEMPT FROM THE ABOVE HAZARDOUS LOCATIONS: <br />1. OPENINGS IN DOORS THROUGH WHICH A 3-INCH SPHERE IS UNABLE TO PASS, <br />2. DECORATIVE GLASS IN ITEMS 1,6 OR 7. <br />3. GLAZING IN SECTION R308.4. ITEM 6. WHEN THERE IS AN INTERVENING WALL ❑R OTHER PERMANENT BARRIER BETWEEN THE <br />DOOR AND THE GLAZING. <br />4. GLAZING IN SECTION R308,4,2, ITEM 3, IN WALLS PERPENDICULAR RO THE PLANE OF THE DOOR IN A CLOSED P❑SITI❑N OR <br />WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET OR STORAGE AREA 3 FEET OR LESS IN DEPTH, GLAZING IN <br />THESE APPLICATIONS SHALL COMPANY WITH SECTION R308.4, ITEM 2, <br />5. GLAZING IN SECTION R308,43, WHEN A PROTECTIVE BAR IS INSTALLED ON THESE ACCESSIBLE SIDE(S) OF THE GLAZSING 36 <br />INCHES ± 2 INCHES ABOVE THE FLOOR, THE BAR DHALL BE CAPABLE OF WITHSTANDING A HORIZONTAL LOAD OF 50 POUNDS <br />PER LINEAR FOOT WITHOUT CONTACTING THE GLASS AND BE A MINIMUM OF 1-1/2 INCHES <br />6. OUTBOARD PANES IN INSULATING GLASS UNITS AND ❑THE MULTIPLE GLAZED PANELS IN SECTION R308.4, ITEM 7, WHEN <br />THE BOTTOM EDGE OF THE GLASS IS 25 FEET OR MORE ABOVE GRADE, A ROOF, WALKING SURFACES, OR OTHER HORTIZ❑NAL <br />(WITHIN 45 DEGREES OF HORTIZ❑NTAL SURFACE ADJACENT TO THE GLASS EXTERIOR. <br />7. LOUVERED WINDOWS AND JALOUSIES COMPLYING WITH THE REQUIREMENTS OF SECTION R308,2 <br />8. MIRRORS AND OTHER GLASS PANELS MOUNTED OR HUNG ON A SURFACE THAT PROVIDES A CONTINUOUS BACKING SUPPORT, <br />9. SAFETY GLAZING IN SECTION R308.4 IS NOT REQUIRED WHERE, <br />9.1 THE SIDE OF STAIRWAY, LANDING OR RAMP HAS A GUARDRAIL OR HANDRAIL, INCLUDING BALUSTERS OR IN -FILL PANELS, <br />C❑MPLYING WITH THE PREVISIONS OF SECTION 1014 OF THE FLORIDA BUILDING CODE, BUILDING AND <br />9.2 THE PLANE OF THE GLASS IS GREATER THEN 18 INCHES FROM THE RAILING, <br />D.W.SMITH,M.S.,P.E.#53608 <br />FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 <br />PROJECTS ENGINEERING CONSULTANT <br />9909 WALLAST❑N DRIVE-DADE CITY, FLORIDA 33525 <br />PHONE: ( CELL) 813-469-2289 E-MAIL: dwsf[pe@eo.rthtink.net <br />BOWMAN PATRICIA <br />4616 WISTERIA DR <br />ZEPHYRHILLS, FLORIDA <br />N OTES <br />SHEET OF <br />I hereby certif y that I have reviewed this plan and f ound it to be in <br />compliance with ASCE 7-16 and the Florida Building Code 2020 7th Edition <br />David W, Smith, RE, #53608 <br />RICK COLLHARDT - DRAFTSMAN <br />PHONE:(CELU 813-781-3651 E-MAIL: rgollhardt@tarp <br />SCALE DATE <br />DO NOT SCALE 1 JUN 2023 <br />DESIGN/DRAWN CHECKED <br />. rn core R. GOLLHARDT D.W.S.PE <br />3OF4 <br />JOB NO. <br />2023-0514 <br />