EL_ECTRICAL_) PLUMBING & MECHANICAL_: <br />IN ACCORDANCE WITH CHAPTER 471,003 (2) (1) OF THE FLORIDA ADMINISTRATIVE CODE, ELECTRICAL <br />PLUMBING AND MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE RESPECTIVE CONTRACTOR TO <br />MEET ALL APPLICABLE CODES. THE ELECTRICAL, PLUMBING AND MECHANICAL SYSTEMS DRAWN HEREON <br />ARE BASED UPON A DESIGN PROVIDED BY THE OWNER TO ADDRESS HIS/HER REQUIREMENTS, <br />ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN, (WITHIN 6' FEET OR SINKS), GARAGE AND AT <br />EXTERIOR LOCATI❑NS SHALL BE WIRED INT❑ A GROUND FAULT INTERRUPTER "GFI" CIRCUIT, "AFI" CIRCUIT, <br />ALL ELECTRICAL OUTLETS IN BEDROOMS & FIXTURES SHALL BE WIRED INT❑ AN ARC -FAULT INTERRUPTER, <br />SMOKE DETECTORS SHALL BE PLACE IN EACH BEDROOM AND IN HALL WAY AREAS ADJACENT <br />TO BEDROOM AND OTHER LIVING AREAS, <br />GROUND WIRE FORM REBAR TO ELECTRICAL PANEL PER N.E.C. <br />DUCTS IN GARAGE AND DUCTS PENETRATING THE WALLS OR CEILING SEPARING THE DWELLING FROM THE <br />GARAGE SHELL BE CONSTRUCTED OF MINIMUM N❑,26 GAUGE SHEET OR OTHER APPROVED MATERIALS <br />AND SHALL HAVE NO OPENINGS INT❑ THE GARAGE (FBC 6TH EDITI❑N 2017 R309) <br />FLORIDA STATUTE 471 <br />ONLY REQUIRES ENGINEERING ON RESIDENTIAL IF THE COST OF THE INDIVIDUAL PLUMBING, ELECTRICAL, <br />PRECTRICALCAN <br />DI 15OVENS <br />$O2 <br />5b0VER MECHANICAL250 FIXTURE UNITS PLUMBING, OVER 600 AMPS <br />FBC BUILDING CHAPTER 1 (105,312) <br />MECHANICAL: <br />CONDENSATE <br />LINES SHALL <br />DISCHARGE <br />AT LEAST 12" AWAY FROM THE STRUCTURE SIDEWALL, WHETHER BY UNDERGROUND <br />PIPING, TAIL <br />EXTENSIONS, <br />OR SPLASH <br />BLOCKS. <br />2020 FMC, 7TH EDITION - EQUIPMENT DISCONNECT MUST BE WITHIN SIGHT OF THE EQUIPMENT. <br />BATHROOMS MUST BE VENTILATED MECHANICALLY AND EXHAUSTED TO BUILDING EXTERIOR. <br />AIR HANDLER FLOAT SWITCHES ARE REQUIRED TO SHUT DOWN THE UNIT OR OTHER APPROVED DEVICE TO ALERT THE HOME <br />OWNER THAT THE CONDENSATE DRAIN LINE IS NOT WORKING PROPERLY. <br />THERE MUST BE A NOTICE POSTED ON THE ELECTRICAL PANEL ALERTING THE HOME OWNER THAT THE AIR HANDLER IS <br />LOCATED IN THE ATTIC (WHEN APPLICABLE). <br />NOTE: <br />MECHANICAL CONTRACTOR TO DETERMINE UNIT SIZE PER ENERGY CALCULATIONS <br />IN ACCORDANCE WITH CHAPTER 471.003 (2) OF THE FLORIDA ADMINSTRATI❑N CODE, <br />MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE <br />RESPECTIVE CONTRACTORS TO MEET ALL APPLICABLE CODES. THE SYSTEMS DRAWN <br />HEREON ARE BASED UPON THE HOMEOWNERS/CONTRACTORS REQUIREMENTS, <br />SMOKE DETECTORS: <br />SMOKE DETECTOR PLACEMENT AND LOCATION SHALL BE CHECKED AT FRAMING. THE PROPER PLACEMENT OF UNITS SHALL BE <br />IN ACCORDANCE WITH THE NATIONAL FIRE PREVENTION CODE SAFETY ACT. MINIMUM REQUIREMENT SHALL BE AS SET FORTH IN <br />7TH EDITION, 2020 FLORIDA BUILDING CODE AND NFPA-70/NATIONAL ELECTRIC CODE 2017 (NEC2017). <br />CARBON MONOXIDE DETECTORS: <br />EVERY BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION IS ISSUED ON OR AFTER 07/01 /08 AND HAVING A <br />FOSSIL—FUEL—BURINING HEATER OR APPLIANCE, A FIREPLACE, OR AN ATTACHED GARAGE SHALL HAVE AN OPERATIONAL <br />CARBON MONOXIDE ALARM INSTALLED WITHIN 10 FEET OF EACH ROOM USED FOR SLEEPING PURPOSED. IN NEW CONSTRUCTION, <br />ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHEN SUCH WIRING IS SERVED FROM THE LOCAL <br />POWER UTILITY. SUCH ALARMS SHALL HAVE BATTERY BACK UP. <br />ELECTRICAL: <br />ALL OUTLETS SHALL BE ON AN AFCI (ARC FAULT CIRCUIT INTERRUPTER) PROTECTED CIRCUIT & TAMPER PROOF, PER <br />2020 7TH EDITION FLORIDA BUILDING CODE, RESIDENTIAL (PART VIII — ELECTRICAL) <br />NEC 2017: 210.12 — ARC FAULT PROTECTION IS NO LONGER LIMITED TO SLEEPING AREAS AND NOW INCLUDE KITCHENS. <br />NEC 2017: 210.8 — INCLUDE GFCI PROTECTION ON CIRCUITS INCLUDING BUT NOT LIMITED TO OUTDOORS, DISHWASHERS, <br />PORCH AND LANAI. <br />ALL OUTSIDE MECHANICAL EQUIPMENT TO HAVE (1) 110 VOLT GFI WP OUTLET WITHIN 25' OF EQUIPMENT IN SITE PLAN. <br />NOTES: <br />UNLESS ❑THERWISE NOTED <br />1. <br />ELECTRICAL OUTLETS HEIGHTS AS MEASURED FROM FINISHED FLOOR <br />CENTERED LINE OF THE BOX TO BE, 12' AFF (GENERAL) <br />KITCHEN <br />44' AFF <br />BATHROOM <br />39' AFF <br />LAUNDRY ROOM <br />36' AFF <br />EXTERI❑R WATERPROOF <br />12' AFF <br />GARAGE GENERAL PURPOSE <br />42' AFF <br />RANGE <br />2' AFF <br />2. <br />ALL TRIM PLATES & DEVICES <br />TO BE GANGED, WHERE <br />P❑SSIBLE <br />3. <br />ELECTRICAL SWITCHES TO BE 42' CENTERLINE AFF, <br />4. <br />ELECTRICAL PLAN IS INTENDED FOR <br />BID PURPOSES ONLY. ALL <br />WORK SHALL <br />BE DONE IN STRICT ACCORDANCE WITH THE NATI❑NAL ELECTRIC CODE, LATEST <br />EDITI❑N, BY LICENSED ELECTRICAL <br />CONTRACTOR WHO SHALL BE <br />RESP❑NSIBLE <br />FOR THE INSTALLATI❑N & SIZING OF <br />ALL ELECTRICAL, WIRING & <br />ACCESS❑RIES. <br />5, <br />GROUND WIRE FORM REBAR TO <br />ELECTRICAL PANEL PER <br />N,E.C, 2017 <br />SYKBOL <br />DESCRIPTION <br />SWITCH <br />$3 <br />3 WAY SWITCH <br />$4 <br />4 WAY SWITCH <br />RHEOSTAT SWITCH <br />8 <br />110 V RECEPTICLE(1/2 SWITCHED) <br />8 <br />110 V RECEPTICLE <br />8GFI <br />110 V RECEPTICLE - GROUND FAULT <br />8AFI <br />110 V RECEPTICLE - ARC FAULT <br />8wp <br />110 V RECEPTICLE - WATERPROOF OUTLET <br />�+ <br />220 V RECEPTICLE <br />DUPLEX OUTLET IN FLOOR <br />110 V QUAD <br />lbwP <br />110 V QUAD WATERPROOF OUTLET <br />® <br />RECESSED INCANDESCENT <br />} <br />LIGHT FIXTURE - WALL OR CEILING (TYP) <br />EXHAUST BATH FAN 110 V 50 CFM'S <br />EXHAUST FAN/LIGHT C❑MBINATI❑N <br />® <br />FL❑URESCENT FIXTURE <br />FLOOD LAMPS <br />VANTITY LIGHT <br />cp <br />PUSH BUTTON FOR GARAGE OPENER <br />s&D <br />SMOKE /FIRE DETECTOR/ALARM <br />cam+ <br />SMOKE/CARBON M❑N❑XIDE DETECTOR - COMBO <br />© <br />CARBON M❑N❑XIDE DETECTOR <br />CEILING FAN ONLY <br />CEILING FAN /LIGHT <br />FAN W/L <br />Cam' <br />DISC❑NNECT <br />ELECTRICAL METER <br />ELECTRICAL PANEL <br />ELECTRICAL PLAN <br />D.W. SMITH,M. S.,P.E. #53608 <br />FLORIDA PR❑FESSI❑NAL ENGINEER LICENSE NUMBER 53608 <br />PROJECTS ENGINEERING CONSULTANT <br />9909 WALLAST❑N DRIVE—DADE CITY, FLORIDA 33525 <br />PHONE: ( CELL) 813-469-2289 E-MAIL; dwsf Ipe@earth I i nk, net <br />RICK GOLLHARDT - DRAFTSMAN <br />PHONE: ( CELL)813-781-3651 E-MA I L: r o I I hardt@tars aba , rr, com R <br />�1 <br />EXISTING <br />PANEL <br />BOWMAN PATRICIA <br />4616 WISTERIA DR <br />ZEPHYRHILLS, FLORIDA <br />ELECTRICAL PLAN <br />SHEET OF <br />4OF4 <br />SCALE <br />DATE <br />JOB NO, <br />DO NOT SCALE <br />1 JUN 2023 <br />2023-0514 <br />DESIGN/DRAWN <br />CHECKED <br />GOLLHARDT <br />D.W.S.PE <br />