EL_ECTRICAL_) PLUMBING & MECHANICAL_:
<br />IN ACCORDANCE WITH CHAPTER 471,003 (2) (1) OF THE FLORIDA ADMINISTRATIVE CODE, ELECTRICAL
<br />PLUMBING AND MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE RESPECTIVE CONTRACTOR TO
<br />MEET ALL APPLICABLE CODES. THE ELECTRICAL, PLUMBING AND MECHANICAL SYSTEMS DRAWN HEREON
<br />ARE BASED UPON A DESIGN PROVIDED BY THE OWNER TO ADDRESS HIS/HER REQUIREMENTS,
<br />ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN, (WITHIN 6' FEET OR SINKS), GARAGE AND AT
<br />EXTERIOR LOCATI❑NS SHALL BE WIRED INT❑ A GROUND FAULT INTERRUPTER "GFI" CIRCUIT, "AFI" CIRCUIT,
<br />ALL ELECTRICAL OUTLETS IN BEDROOMS & FIXTURES SHALL BE WIRED INT❑ AN ARC -FAULT INTERRUPTER,
<br />SMOKE DETECTORS SHALL BE PLACE IN EACH BEDROOM AND IN HALL WAY AREAS ADJACENT
<br />TO BEDROOM AND OTHER LIVING AREAS,
<br />GROUND WIRE FORM REBAR TO ELECTRICAL PANEL PER N.E.C.
<br />DUCTS IN GARAGE AND DUCTS PENETRATING THE WALLS OR CEILING SEPARING THE DWELLING FROM THE
<br />GARAGE SHELL BE CONSTRUCTED OF MINIMUM N❑,26 GAUGE SHEET OR OTHER APPROVED MATERIALS
<br />AND SHALL HAVE NO OPENINGS INT❑ THE GARAGE (FBC 6TH EDITI❑N 2017 R309)
<br />FLORIDA STATUTE 471
<br />ONLY REQUIRES ENGINEERING ON RESIDENTIAL IF THE COST OF THE INDIVIDUAL PLUMBING, ELECTRICAL,
<br />PRECTRICALCAN
<br />DI 15OVENS
<br />$O2
<br />5b0VER MECHANICAL250 FIXTURE UNITS PLUMBING, OVER 600 AMPS
<br />FBC BUILDING CHAPTER 1 (105,312)
<br />MECHANICAL:
<br />CONDENSATE
<br />LINES SHALL
<br />DISCHARGE
<br />AT LEAST 12" AWAY FROM THE STRUCTURE SIDEWALL, WHETHER BY UNDERGROUND
<br />PIPING, TAIL
<br />EXTENSIONS,
<br />OR SPLASH
<br />BLOCKS.
<br />2020 FMC, 7TH EDITION - EQUIPMENT DISCONNECT MUST BE WITHIN SIGHT OF THE EQUIPMENT.
<br />BATHROOMS MUST BE VENTILATED MECHANICALLY AND EXHAUSTED TO BUILDING EXTERIOR.
<br />AIR HANDLER FLOAT SWITCHES ARE REQUIRED TO SHUT DOWN THE UNIT OR OTHER APPROVED DEVICE TO ALERT THE HOME
<br />OWNER THAT THE CONDENSATE DRAIN LINE IS NOT WORKING PROPERLY.
<br />THERE MUST BE A NOTICE POSTED ON THE ELECTRICAL PANEL ALERTING THE HOME OWNER THAT THE AIR HANDLER IS
<br />LOCATED IN THE ATTIC (WHEN APPLICABLE).
<br />NOTE:
<br />MECHANICAL CONTRACTOR TO DETERMINE UNIT SIZE PER ENERGY CALCULATIONS
<br />IN ACCORDANCE WITH CHAPTER 471.003 (2) OF THE FLORIDA ADMINSTRATI❑N CODE,
<br />MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE
<br />RESPECTIVE CONTRACTORS TO MEET ALL APPLICABLE CODES. THE SYSTEMS DRAWN
<br />HEREON ARE BASED UPON THE HOMEOWNERS/CONTRACTORS REQUIREMENTS,
<br />SMOKE DETECTORS:
<br />SMOKE DETECTOR PLACEMENT AND LOCATION SHALL BE CHECKED AT FRAMING. THE PROPER PLACEMENT OF UNITS SHALL BE
<br />IN ACCORDANCE WITH THE NATIONAL FIRE PREVENTION CODE SAFETY ACT. MINIMUM REQUIREMENT SHALL BE AS SET FORTH IN
<br />7TH EDITION, 2020 FLORIDA BUILDING CODE AND NFPA-70/NATIONAL ELECTRIC CODE 2017 (NEC2017).
<br />CARBON MONOXIDE DETECTORS:
<br />EVERY BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION IS ISSUED ON OR AFTER 07/01 /08 AND HAVING A
<br />FOSSIL—FUEL—BURINING HEATER OR APPLIANCE, A FIREPLACE, OR AN ATTACHED GARAGE SHALL HAVE AN OPERATIONAL
<br />CARBON MONOXIDE ALARM INSTALLED WITHIN 10 FEET OF EACH ROOM USED FOR SLEEPING PURPOSED. IN NEW CONSTRUCTION,
<br />ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHEN SUCH WIRING IS SERVED FROM THE LOCAL
<br />POWER UTILITY. SUCH ALARMS SHALL HAVE BATTERY BACK UP.
<br />ELECTRICAL:
<br />ALL OUTLETS SHALL BE ON AN AFCI (ARC FAULT CIRCUIT INTERRUPTER) PROTECTED CIRCUIT & TAMPER PROOF, PER
<br />2020 7TH EDITION FLORIDA BUILDING CODE, RESIDENTIAL (PART VIII — ELECTRICAL)
<br />NEC 2017: 210.12 — ARC FAULT PROTECTION IS NO LONGER LIMITED TO SLEEPING AREAS AND NOW INCLUDE KITCHENS.
<br />NEC 2017: 210.8 — INCLUDE GFCI PROTECTION ON CIRCUITS INCLUDING BUT NOT LIMITED TO OUTDOORS, DISHWASHERS,
<br />PORCH AND LANAI.
<br />ALL OUTSIDE MECHANICAL EQUIPMENT TO HAVE (1) 110 VOLT GFI WP OUTLET WITHIN 25' OF EQUIPMENT IN SITE PLAN.
<br />NOTES:
<br />UNLESS ❑THERWISE NOTED
<br />1.
<br />ELECTRICAL OUTLETS HEIGHTS AS MEASURED FROM FINISHED FLOOR
<br />CENTERED LINE OF THE BOX TO BE, 12' AFF (GENERAL)
<br />KITCHEN
<br />44' AFF
<br />BATHROOM
<br />39' AFF
<br />LAUNDRY ROOM
<br />36' AFF
<br />EXTERI❑R WATERPROOF
<br />12' AFF
<br />GARAGE GENERAL PURPOSE
<br />42' AFF
<br />RANGE
<br />2' AFF
<br />2.
<br />ALL TRIM PLATES & DEVICES
<br />TO BE GANGED, WHERE
<br />P❑SSIBLE
<br />3.
<br />ELECTRICAL SWITCHES TO BE 42' CENTERLINE AFF,
<br />4.
<br />ELECTRICAL PLAN IS INTENDED FOR
<br />BID PURPOSES ONLY. ALL
<br />WORK SHALL
<br />BE DONE IN STRICT ACCORDANCE WITH THE NATI❑NAL ELECTRIC CODE, LATEST
<br />EDITI❑N, BY LICENSED ELECTRICAL
<br />CONTRACTOR WHO SHALL BE
<br />RESP❑NSIBLE
<br />FOR THE INSTALLATI❑N & SIZING OF
<br />ALL ELECTRICAL, WIRING &
<br />ACCESS❑RIES.
<br />5,
<br />GROUND WIRE FORM REBAR TO
<br />ELECTRICAL PANEL PER
<br />N,E.C, 2017
<br />SYKBOL
<br />DESCRIPTION
<br />SWITCH
<br />$3
<br />3 WAY SWITCH
<br />$4
<br />4 WAY SWITCH
<br />RHEOSTAT SWITCH
<br />8
<br />110 V RECEPTICLE(1/2 SWITCHED)
<br />8
<br />110 V RECEPTICLE
<br />8GFI
<br />110 V RECEPTICLE - GROUND FAULT
<br />8AFI
<br />110 V RECEPTICLE - ARC FAULT
<br />8wp
<br />110 V RECEPTICLE - WATERPROOF OUTLET
<br />�+
<br />220 V RECEPTICLE
<br />DUPLEX OUTLET IN FLOOR
<br />110 V QUAD
<br />lbwP
<br />110 V QUAD WATERPROOF OUTLET
<br />®
<br />RECESSED INCANDESCENT
<br />}
<br />LIGHT FIXTURE - WALL OR CEILING (TYP)
<br />EXHAUST BATH FAN 110 V 50 CFM'S
<br />EXHAUST FAN/LIGHT C❑MBINATI❑N
<br />®
<br />FL❑URESCENT FIXTURE
<br />FLOOD LAMPS
<br />VANTITY LIGHT
<br />cp
<br />PUSH BUTTON FOR GARAGE OPENER
<br />s&D
<br />SMOKE /FIRE DETECTOR/ALARM
<br />cam+
<br />SMOKE/CARBON M❑N❑XIDE DETECTOR - COMBO
<br />©
<br />CARBON M❑N❑XIDE DETECTOR
<br />CEILING FAN ONLY
<br />CEILING FAN /LIGHT
<br />FAN W/L
<br />Cam'
<br />DISC❑NNECT
<br />ELECTRICAL METER
<br />ELECTRICAL PANEL
<br />ELECTRICAL PLAN
<br />D.W. SMITH,M. S.,P.E. #53608
<br />FLORIDA PR❑FESSI❑NAL ENGINEER LICENSE NUMBER 53608
<br />PROJECTS ENGINEERING CONSULTANT
<br />9909 WALLAST❑N DRIVE—DADE CITY, FLORIDA 33525
<br />PHONE: ( CELL) 813-469-2289 E-MAIL; dwsf Ipe@earth I i nk, net
<br />RICK GOLLHARDT - DRAFTSMAN
<br />PHONE: ( CELL)813-781-3651 E-MA I L: r o I I hardt@tars aba , rr, com R
<br />�1
<br />EXISTING
<br />PANEL
<br />BOWMAN PATRICIA
<br />4616 WISTERIA DR
<br />ZEPHYRHILLS, FLORIDA
<br />ELECTRICAL PLAN
<br />SHEET OF
<br />4OF4
<br />SCALE
<br />DATE
<br />JOB NO,
<br />DO NOT SCALE
<br />1 JUN 2023
<br />2023-0514
<br />DESIGN/DRAWN
<br />CHECKED
<br />GOLLHARDT
<br />D.W.S.PE
<br />
|