My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5326 8th St
Zephyrhills
>
Building Department
>
Building Plans
>
5326 8th St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 11:20:37 PM
Creation date
2/18/2025 3:30:04 PM
Metadata
Fields
Template:
Building Plans
Street #
5326
Location
8th St
Contractor
Racine Construction
Building Plans - Permit #
15974
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BUILDING CODE SUMMARY <br />FOR ALL COMMERCIAL PROJECTS <br />Name of Project: Wells Fargo WFA Relocation <br />Address: 5326 8th Street, Zephyrhills, Florida 33542 <br />Proposed Use: Wells Fargo Advisor Group - Financial Services <br />Owner or Authorized Agent: Jonathan Zak- Project Manager <br />Phone # 832.727,4563 <br />Owned By: ❑ City/County <br />■ Private ❑ State <br />Code Enforcement Jurisdiction: ■ City Zephyrhills <br />❑ County Pasco ■ State FL <br />PROJECT SUMMARY <br />Building description: ONE STORY CMU BUILDING FOR TRADITIONAL BANKING <br />LEAD DESIGN PROFESSIONAL: AL COOPER, ARCHITECTURAL DESIGN COLLABORATIVE <br />DESIGNER FIRM NAME <br />LICENSE# PHONE# E-MAIL <br />Architectural ADC AI Cooper <br />10460 407.629.1188 acooper@adcintemational.net <br />Civil NA NA <br />NA NA NA <br />Electrical NA NA <br />NA NA NA <br />Fire Alarm NA NA <br />NA NA NA <br />Plumbing NA NA <br />NA NA NA <br />Mechanical NA NA <br />NA NA NA <br />Sprinkler -Standpipe NA NA <br />NA NA NA <br />Structural NA NA <br />NA NA NA <br />YEAR EDITION OF CODE: 2010 Florida Building Code <br />❑ New Construction ❑ Addition ❑ Upfit ❑ Renovation (Existing Bldg.) ❑ Repair ■ Alteration ❑ Reconstruction <br />BUILDING DATA <br />Construction Type: ❑ I -A ❑ I-B ❑ II -A <br />■ II-B ❑ III -A <br />❑ III-B ❑ IV ❑ V-A <br />❑ V-B <br />Mixed Construction: ■ No <br />❑ Yes Types: <br />Sprinklers: ■ No ❑ Partial ❑ Yes ❑ NFPA 13 <br />❑ NFPA 13 ❑ NFPA 13D ❑ ESFR <br />Standpipes: ■ No ❑ Yes NFPA 14-00 Type: ❑ 1 <br />❑ II ❑ III ❑ Wet ❑ Dry <br />Fire District: ■ No ❑ Yes Flood Hazard Area: ■ No ❑ Yes <br />Building Height:_ Exist. Feet Number of Stories <br />1 ❑ Unlimited per <br />_ <br />Mezzanine: ■ No ❑ Yes <br />High Rise: ■ No ❑ Yes Central Reference Sheet # (if provided) <br />Compliant High Rise: ■ No ❑ Yes <br />Gross Building Area (sq. ft.): RENO/ <br />RENO/ <br />FLOOR EXISTING NEW UPFIT <br />FLOOR EXISTING NEW UPFIT <br />6th Floor <br />14th Floor <br />5th Floor <br />13th Floor <br />4th Floor <br />12th Floor <br />3rd Floor <br />11th Floor <br />2nd Floor <br />10th Floor <br />Mezzanine <br />9th Floor <br />1st Floor 1,264 <br />8th Floor <br />Basement <br />7th Floor <br />TOTAL 1,264 <br />ALLOWABLE AREA <br />Primary Occupancy: ❑ Assembly ❑ A-1 <br />❑ A-2 ❑ A-3 ❑ A-4 ❑ A-5 <br />■ Business ❑ Education ❑ Factory <br />❑ F-1 Moderate ❑ F-2 Low <br />❑ Hazardous ❑ H-1 Detonate ❑ H-2 Deflagrate <br />❑ H-3 Combust ❑ H-4 Health ❑ H-5 HPM <br />❑ Institutional ❑ 1-1 ❑ 1-2 <br />❑ 1-3 ❑ 1-4 <br />1-3 Condition ❑ 1 <br />❑ 2 ❑ 3 ❑ 4 ❑ 5 <br />❑ Mercantile ❑ Residential ❑ R-1 <br />❑ R-2 ❑ R-3 ❑ R-4 <br />❑ Storage ❑ S-1 Moderate ❑ S-2 Low <br />❑ High -piled <br />❑ Utility and Miscellaneous ❑ Parking Garage <br />❑ Open ❑ Enclosed ❑ Repair Garage <br />Secondary Occupancy: NA <br />LIFE SAFETY SYSTEM REQUIREMENTS <br />N.C. = Non Combustible <br />Emergency Lighting: <br />■ No <br />❑ Yes <br />N.R. = Not Required <br />Exit Signs: <br />❑ No <br />■ Yes <br />N/A = Not Applicable <br />Fire Alarm: <br />■ No <br />❑ Yes <br />S = Section <br />Smoke Detection Systems: <br />❑ No <br />■ Yes - Home Style Smoke Detectors <br />T = Table <br />Panic Hardware: <br />❑ No <br />❑ Yes <br />Life Safety Systems Generator: <br />■ No <br />❑ Yes <br />EXIT REQUIREMENTS <br />NUMBER AND ARRANGEMENT OF EXITS <br />FLOOR, ROOM OR <br />SPACE DESIGNATION <br />MINIMUM 2 <br />NUMBER OF EXITS <br />TRAVEL DISTANCE <br />ARRANGEMENT MEANS OF <br />EGRESS SECTION 1015.2 <br />REQUIRED <br />SHOWN <br />ON PLANS <br />ALLOWABLE TRAVEL <br />DISTANCE <br />(TABLE 1016.1) <br />ACTUAL <br />TRAVEL <br />DISTANCE <br />SHOWN ON <br />PLANS <br />REQUIRED <br />DISTANCE <br />BETWEEN <br />EXIT DOORS <br />ACTUAL <br />DISTANCE <br />SHOWN ON <br />PLANS <br />Existing 1st Floor <br />1 <br />2 <br />2007300' <br />34'-9" <br />NA <br />NA <br />1 Corridor Dead Ends (Section 1018.4) <br />2 Single Exits (Table 1021.2), Spaces w/ 1 means of egress (Table 1015.1) <br />3 Common Path of Travel (Section 1014.3) <br />EXIT WIDTH <br />USE GROUP <br />SPACE <br />7 <br />DES <br />(a) <br />(b) <br />(c) <br />EXIT WIDTH (in) <br />AREA' <br />sq. ft. <br />AREA' <br />PER <br />OCCUPANT <br />EGRESS WIDTH <br />PER OCCUPANT <br />(Section 1005.1) <br />REQUIRED WIDTH <br />(Section 1005.1) <br />ACTUAL WIDTH— <br />SHOWN ON PLANS <br />STAIR <br />LEVEL <br />STAIR <br />LEVEL <br />STAIR <br />LEVEL <br />Existing - Business <br />1,264 <br />100 <br />NA <br />.2 <br />NA <br />2.6 <br />NA <br />64 <br />1 See Table 1004.1.2 to determine whether net or gross area is applicable, <br />See definition "Area, Gross" and "Area, Net" (Section 1002). <br />2 Minimum stairway width (Section 1009.4); min. corridor width (Section 1018.2); <br />min. doorwidth (Section 1008.1) <br />3 Minimum width of exit passageway (Section 1023.2) <br />4 See Section 1005.6 for converging exits. <br />5 The loss of one means of egress shall not reduce the available capacity to less than 50 percent <br />of the total required (Section 1005.2) <br />6 Assembly Occupancies (Section 1028). <br />Spaces within occupancies or use groups shall be calculated independently (ex. lobbies, lounges, break <br />rooms and conference rooms). <br />ENERGY SUMMARY NA <br />This section for new construction, additions, change of use and interior completions. <br />ENERGY REOUIREMENTS: <br />The following data shall be considered minimum and any special attribute required to meet the energy code <br />shall also be provided. Each Designer shall furnish the required portions of the project information for the plan <br />data sheet. If energy cost budget method, state the annual energy cost budget vs. allowable annual energy cost <br />budget. <br />THERMAL ENVELOPE N/A Climate Zone: 2 <br />METHOD OF COMPLIANCE: [3 No Change to Building Envelope <br />■ Prescriptive 0 Performance [3 Energy Cost Budget <br />ELECTRICAL SYSTEM AND EOUIPMENT N/A <br />METHOD OF COMPLIANCE: 0 No Change to Building System <br />[3 Prescriptive [3 Performance 13 Energy Cost Budget <br />MECHANICAL SYSTEMS, SERVICE SYSTEMS AND EQUIPMENT N/A <br />METHOD OF COMPLIANCE: [3 No Change to Building System <br />Prescriptive [3 Energy Cost Budget <br />SHOP DRAWINGS <br />THE CONTRACTOR SHALL REVIEW FOR COMPLIANCE WITH THE CONTRACT <br />DOCUMENTS, APPROVE AND SUBMIT TO THE ARCHITECT SHOP DRAWINGS, <br />PRODUCT DATA, SAMPLES AND SIMILAR SUBMITTALS REQUIRED BY THE <br />CONTRACT DOCUMENTS IN ACCORDANCE WITH THE SUBMITTAL SCHEDULE <br />APPROVED BY THE ARCHITECT OR, IN THE ABSENCE OF AN APPROVED <br />SUBMITTAL SCHEDULE, WITH REASONABLE PROMPTNESS AND IN SUCH <br />SEQUENCE AS TO CAUSE NO DELAY IN THE WORK OR IN THE ACTIVITIES OF <br />THE OWNER OR OF SEPARATE CONTRACTORS. <br />BY SUBMITTING SHOP DRAWINGS, PRODUCT DATA, SAMPLES AND SIMILAR <br />SUBMITTALS, THE CONTRACTOR REPRESENTS TO THE OWNER AND ARCHITECT <br />THAT THE CONTRACTOR HAS (1) REVIEWED AND APPROVED THEM, (2) <br />DETERMINED AND VERIFIED MATERIALS, FIELD MEASUREMENTS AND FIELD <br />CONSTRUCTION CRITERIA RELATED THERETO, OR WILL DO SO AND (3) <br />CHECKED AND COORDINATED THE INFORMATION CONTAINED WITHIN SUCH <br />SUBMITTALS WITH THE REQUIREMENTS OF THE WORK AND OF THE CONTRACT <br />DOCUMENTS. <br />PLUMBING FIXTURE REQUIREMENTS <br />OCCUPANCY <br />WATER CLOSETS <br />URINALS <br />LAVATORIES <br />SHOWERS/ <br />TUBS <br />DRINKING FOUNTAINS <br />MALE <br />FEMALE <br />MALE <br />FEMALE <br />REGULAR <br />ACCESSIBLE <br />1st Floor, Business <br />1 <br />1 <br />1 <br />1 <br />0 <br />0 <br />ACCESSIBLE PARKING — ON STREET MUNICIPAL PARKING <br />LOT OR PARKING <br />AREA <br />TOTAL # OF PARKING SPACES <br /># OF ACCESSIBLE SPACES PROVIDED <br />TOTAL # <br />ACCESSIBLE <br />PROVIDED <br />REQUIRED <br />PROVIDED <br />REGULAR WITH 5' <br />ACCESS AISLE <br />VAN SPACES W/ 5' <br />ACCESS AISLE <br />Business <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />TOTAL <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />SPECIAL APPROVALS <br />Special Approval: (Local Jurisdiction, Department of Insurance, ICC, etc., describe below) <br />LOCATION MAP <br />19 <br />PROJECT SUMMARY AND CODE DATA <br />PROJECT NAME: WELLS FARGO WFA - RELOCATION <br />PROJECT ADDRESS: 5326 8th STREET, FLORIDA 33542 <br />PROJECT TYPE: INTERIOR TENANT IMPROVEMENT <br />THE PROJECT WILL NOT TARGET LEED CERTIFICATION <br />SQUARE FOOTAGE CALCULATIONS: <br />BUILDING FOOTPRINT: 1,534 SQ.FT. <br />A/C SQ.FT.: 1,264 SQ.FT. <br />COVERED FRONT ENTRANCE: 270 SF Under Roof <br />BUILDING GROSS SQ.FT.: 1,534 SF ( INCLUDES COVERED FRONT ENTRANCE) <br />APPLICABLE CODES <br />YEAR <br />FLORIDA BUILDING CODE <br />2010 <br />FLORIDA ACCESSIBILITY CODE <br />2012 <br />FLORIDA MECHANICAL CODE <br />2010 <br />FLORIDA PLUMBING CODE <br />2010 <br />FLORIDA FIRE PREVENTION CODE <br />NFPA 101 LIFE SAFETY CODE <br />2010 <br />NFPA 1, FIRE PREVENTION CODE <br />2010 <br />NFPA 70 NATIONAL ELECTRIC CODE <br />2008 <br />OCCUPANCY CLASSIFICATION <br />BUSINESS - GROUP B <br />CONSTRUCTION TYPE <br />TYPE IIB - UNSPRINKLED - UNPROTECTED <br />DESIGN OCCUPANT LOAD <br />13 <br />EGRESS CAPACITY: <br />EGRESS WIDTH/EGRESS UNIT: ( AVAILABLE DOORS = 2 @ 64') <br />/ (0.2" PER PERSON) <br />= 320 OCCUPANTS <br />HEIGHT AND AREA <br />ACTUAL <br />ALLOWED/REQUIRED <br />BUILDING HEIGHT <br />17'-0" ( EST) <br />55 FT/3 STORIES/23,000S.F. ALLOWED <br />BUILDING AREA <br />1,264 S.F. <br />NA <br />NOTE: BUILDING AREA MEASURED FROM OUTSIDE FACE <br />OF MASONRY WALL TO OUTSIDE FACE OF WALL <br />MEANS OF EGRESS - BUSINESS OCCUPANCY: <br />TRAVEL DISTANCE <br />34'-9" <br />75 FEET MAX. <br />COMMON PATH OF TRAVEL <br />N/A <br />N/A <br />OCCUPANT LOAD ( GROUP B) <br />@ 1 PERSON/ 100 S.F.= <br />13 PERSONS <br />NUMBER OF EXITS <br />1 <br />1 MIN. ( LESS THAN 49 PEOPLE) <br />LEVEL EGRESS WIDTH (@ 0.27PERSON) <br />64 INCHES <br />2.6 INCHES MIN. <br />VERTICAL EGRESS WIDTH <br />N/A <br />N/A <br />FIRE RATED CONSTRUCTION AND SEPARATION <br />ATTIC DRAFT STOP N/A N/A <br />FIRE PROTECTION <br />SPRINKLER <br />NONE <br />NONE <br />FIRE ALARM <br />NONE <br />NFPA10 <br />FIRE EXTINGUISHERS <br />1 <br />NFPA 10 <br />EMERGENCY LIGHTING <br />PROVIDED <br />NFPA 101 <br />EXIT SIGNS <br />PROVIDED <br />NFPA 101 <br />PROJECT NARRATIVE: <br />THIS IS AN INTERIOR TENANT IMPROVEMENT PROJECT, LARGELY COSMETIC IN NATURE. <br />THE EXISTING BUILDING IS LANDLORD OWNED AND USED AS AN OFFICE/BUSINESS CLASSIFICATION. <br />THE NEW TENANT IS WELLS FARGO - ADVISORS GROUP. <br />THE EXISTING BATHROOM WILL BE RE -CONFIGURED TO PROVIDE AN ACCESSIBLE BATHROOM. THIS WILL REQUIRE SEVERAL <br />WALLS AND DOORS TO BE REMOVED AND REPLACED. <br />AN EXISTING OFFICE WILL BE EXPANDED TO FORM A CONFERENCE ROOM. A NEW DOOR WILL BE ADDED TO THE <br />CONFERENCE ROOM. LEVER HARDWARE WILL BE ADDED TO CUSTOMER FACING AREAS AND TO THE NEW FRONT DOOR. <br />A NEW FRONT ENTRANCE DOOR WILL BE INSTALLED. <br />ELECTRICAL OUTLETS AND SWITCHES ASSOCIATED WITH THE UPGRADE/TENANT IMPROVEMENTS WILL BE RE -LOCATED AS <br />NECESSARY. <br />SURFACES, MATERIALS AND/OR FINISHES ADJACENT TO AREAS BEING UPGRADED WILL BE REPAIRED AS NECESSARY. <br />PAINTING OF SELECTED WALLS AND/OR CEILINGS WILL BE DONE. SOME BRANDING/SIGNAGE WILL BE PLACED INSIDE TO <br />IDENTIFY THE SERVICES WELLS FARGO WILL BE PROVIDING FROM THIS OFFICE. <br />NO CHANGE TO THE BUILDING FOOTPRINT OR OCCUPANCY CLASSIFICATION IS ANTICIPATED IN THE SCOPE OF THIS <br />PROJECT. <br />INDEX OF DRAWINGS <br />COVER <br />GENERAL <br />G1.0 BUILDING CODE SUMMARY <br />G1.2 ACCESSIBILITY <br />ARCHITECTURAL <br />A1.01 FLOOR PLAN - EXISTING CONDITIONS <br />A1.02 DEMO FLOOR PLAN <br />A1.03 CONSTRUCTION PLAN <br />A1.10 REFLECTED CEILING PLAN -EXISTING CONDITIONS <br />A1.10.1 REFLECTED CEILING PLAN -NE <br />A3.40 ENLARGED RESTROOM PLANS AND ELEVATIONS <br />FINISHES <br />F1.0 FINISH PLAN <br />WELLS FARGO <br />ADVISORS <br />ZEPHYRHILLS <br />RELOCATION <br />5326 8th STREET <br />ZEPHYRHILLS, FL 33542 <br />010 <br />eft, <br />�.� <br />A41TECTUFa <br />DESIGN CISLLTIVE <br />A <br />AN <br />....a <br />--------------- <br />945 N. PENNSYLVANIA AVE <br />WINTER PARK, FL 32789 <br />OFFICE: (407) 629-1188 <br />FAX: (407) 388-1220 <br />WWW. ADCINTERNATIONAL.NET <br />CLIENT ISSUE DATES <br />NO. <br />DESCRIPTION <br />DATE <br />1 <br />TEST FIT <br />09/02/14 <br />2 <br />50% REVIEW SET <br />11/05/14 <br />3 <br />95% REVIEW SET <br />11/12/14 <br />4 <br />100% CD/B.I.S. <br />11/25/14 <br />5 <br />100% CD/P.I.S. <br />01/15/15 <br />PA <br />JAN 1 2015 <br />Albert J Cooper III AA-CO01315 STATE #AR-0010460 <br />REVISIONS <br />NO. DESCRIPTION DATE <br />DATE ISSUEDi 09/02/14 <br />REVIEWED BYi AC <br />DRAWN BYi AC <br />DESIGNED BYi AC <br />WELLS FARGO BE#: <br />108880 <br />SHEET TITLE <br />BUILDING <br />CODE <br />SUMMARY <br />SHEET NUMBER <br />GImO <br />ADC PROJECT NUMBERi 14303 <br />
The URL can be used to link to this page
Your browser does not support the video tag.