NOTE: IN ALTERATIONS, APROJECTION OF5/8"MAXIMUM INTO THE REQUIRED ACCESSIBILITY NOTES.
<br />32 MIN. CLEAR WIDTH SHALL BE PERMITTED FOR THE LAWIDTH LATCH SIDE STOP. CLEAR ANY AMOUNT o
<br />�------F- Lobby
<br />4 MAX. I _ _ —, 1. FOR RESTROOMS ACCESSIBLE TO THE PUBLIC. "
<br />W I THE WALLS AND FLOORS OF TOILET, BATHING AND SHOWER
<br />ROOMS SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACE. r'
<br />O N THE INTERSECTIONS OF SUCH FLOORS WITH WALLS SHALL HAVE A
<br />LLI I SMOOTH, HARD, NONABSORBENT VERTICAL BASE THAT EXTENDS
<br />o Z I I z = Z I m I UPWARD ONTO THE WALLS AT LAST 4 INCHES. WALLS AND
<br />U = I o r PARTITIONS WITHIN 2 FEET OR URINALS AND WATER CLOSETS
<br />2 — — — — SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACE, TO A s
<br />MIN. 00 e I N X HEIGHT OF 4 FEET ABOVE THE FLOOR, AND EXCEPT FOR
<br />STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS
<br />Z SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY
<br />4 ACCESSORIES SUCH AS GRAB BARS, TOWEL BARS, PAPER
<br />NOTE: X SHALL BE <25in.; Z SHALL BE > X, DISPENSERS AND SOAP DISHES, PROVIDED ON OR WITHIN WALLS,
<br />NOTE: CLEAR WIDTH 32" MIN. BETWEEN — — — — Z SHALL BE INSTALLED AND SEALED TO PROTECT STRUCTURAL
<br />FACE OF THE DOOR AND THE STOPEli — — — — /, WHEN X S < 20in, THEN Y SHALL BE 48in. MAXIMUM. ELEMENTS FROM MOISTURE.
<br />WHEN X IS 20 TO 25in., THEN Y SHALL BE 44in. MAXIMUM 48"
<br />NOTE: OPERABLE PARTS SHALL BE I 5 PROTRUDING OBJECTS J E C T S 2. ALL DIMENSIONS N ABOVE FINISHED FLOOR (A." OR WELLS FARGO
<br />OPERABLE WITH ONE HAND AND SHALL .�.� FWD REACH DETAIL DIMENSIONS THAT ARE NOT STATED AS "MAXIMUM" OR "MINIMUM"
<br />NOT REQUIRE TIGHT GRASPING, Z I 1/4" = 1'-0" 1 O ARE ABSOLUTE. ADVISORS
<br />PINCHING,OR TWISTING OF THE WRIST. ( I I NOTE: X — 1'-O" MIN. IF DOOR HAS I 1/2" = 1'-0" 3. ALL DIMENSIONS ARE TO FINISH SURFACES AND SHALL BE
<br />THE FORCE REQUIRED TO ACTIVATE OD CONSIDERED "CLEAR" DIMENSIONS. T FOOT TURNING ZEPHYRHILLS
<br />� BOTH A CLOSER AND A LATCH. , CIRCLE IS A "GEAR" DIMENSION CONTINUOUS NUOUS FROM THE FLOOR
<br />OPERABLE PARTS SHALL BE 5 POUNDS I I I AUDIBLE/VISIBLE STROBE / DOOR FRAME AND UP THE WALLS. THE FINISHED BASE AND/OR TRIM MATERIALS
<br />MAXIMUM. I I i ,/ SHALL NOT DIMINISH THE REQUIRED 5 FOOT DIMENSION AT THE RELOCATION
<br />FLOOR OR THE WALLS OF THE ROOM.
<br />L — _ — — _L _ HOLD UP LIGHT GC SHALL LAY OUT THE WORK TO ACCOMMODATE THE THICKNESS
<br />FIRE EXTINGUISHER / OF MATERIALS AND ALLOW FOR VARIATIONS IN EXISTING AND NEW 6326 8th STREET
<br />FRONT APPROACH PULL/PUSH SIDE AND/OR HOSE CABINET / i SURFACES AND MATERIALS TO PROVIDE THE REQUIRED "CLEAR"
<br />i THERMOSTAT LOCATION
<br />DIMENSIONS. ZEPHYRHILLS, FL 33542 �
<br />j (DO NOT LOCATE DIRECTLY 4. IF TOILETS ARE UPGRADED FOR ADA. REFER TO SHEET A3.40 FOR
<br />ABOVE DIMMERS) ADDITIONAL ACCESSIBILITY DETAILS, NOTES AND THE
<br />LOCATION FOR: LIGHT / ACCESSORIES AND FIXTURE SCHEDULES.
<br />Z Z SWITCH, DIMMERS, % , AREA OF 5. DETAILS SUPERSEDE PLANS. IN THE EVENT OF CONFLICTING ^
<br />EGRESS BUTTON, CARD INFORMATION GC TO CONTACT ARCHITECT IMMEDIATELY.
<br />READER, (ETC.) , REFUGE
<br />\ A ITECTU DESIGN RATIVE
<br />\\ \\ CLUSTER - SEE PLAN FOR 6. FLOOR SURFACES SHALL BE SLIP -RESISTANT.
<br />00 \ \ 6 5 QUANTITY OF EACH
<br />\ \\ CLUSTER \ 7. EVERY CORRIDOR AND AISLE SERVING AN OCCUPANT LOAD OF 10�
<br />\ \\\ OR MORE SHALL BE NOT LESS THAN 44" IN WIDTH.
<br />X o U \\ \\ ul X W 8. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE
<br />NOTE: Y = 3'-0" MIN. IF Y= 5'-0"; LLO LL �° p \\ \\\ SHALL NOT EXCEED 1/2" IN HEIGHT. LEVEL CHANGES NOT
<br />X= 3-6" MIN. IF Y= 4'-6". I w LU \\ \ Q U tY Q EXCEEDING 1/4" MAYBE VERTICAL. BEVEL OTHERS WITH A SLOPE
<br />W o N USE GANG -TYPE COVER \\ � < Lu W NO GREATER THAN 1:2 945 N. PENNSYLVANIA AVE
<br />z z \ PLATES FOR MORE THAN \ F- H ~
<br />LU _ `' \\ ONE DEVICE OF THE SAME \\ Q W Q 9. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WINTER PARK, FL 32789
<br />\\ TYPE \\ �$LI Q = Q WHICH ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH A OFFICE: (407) 629-1188
<br />\\ \\ O U = U FAX: (407
<br />SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, ) 388-1220
<br />HINGE APPROACH, PULL SIDE PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED WWW.A)388-1RNATIONAL.NET
<br />\ SCHED. DOOR HARDWARE \\ TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO
<br />GRASP THE OPENING HARDWARE. MOUNT DOOR OPENING
<br />NOTE: ALL DIMENSIONS TO CENTER LINE OF DEVICES. HARDWARE BETWEEN 30" AND 44" ABOVE FLOOR FINISH. CLIENT ISSUE DATES
<br />SEE PLANS FOR SPECIFIC LOCATIONS. 10. MAXIMUM PULL OR PUSH EFFORT TO OPERATE DOORS SHALL
<br />NOT EXCEED 8.5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS NO. DESCRIPTION DATE
<br />FOR INTERIOR DOORS, MEASURED AT RIGHT ANGLES TO HINGED
<br />4 TYPICAL MOUNTING HEIGHT DETAIL S I G N A G E DETAIL DOORS AND AT CENTER PLANE OF SLIDING OR FOLDING DOORS 1 TEST FIT 09/02/14
<br />9 CORRESPONDING DEVICES OR AUTOMATIC DOOR OPERATORS
<br />1�2" 1'-0" 1/2" = 1'-0" MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. MAXIMUM 2 50% REVIEW SET 11/05/14
<br />� I I EFFORT TO OPERATE REQUIRED FIRE DOORS MAY BE INCREASED 3 9696 REVIEW SET 11/12/14
<br />NOT TO EXCEED 15 POUNDS.
<br />24"
<br />11, THE BOTTOM 10" OF ALL DOORS (EXCEPT SLIDING AND 4 100% CD/B.I.S. 11/25/14
<br />AUTOMATIC)LU TO AL OWTHE DOORTSMOOTH UNINTERRUPTED SURFACE
<br />O BE BY WHEELCHAIR5 100% CD/P.I.S. 01/15/15
<br />z FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS
<br />Q CONDITION. PROVIDE A 10" HIGH SMOOTH PANEL ON THE PUSH
<br />SIDE OF NARROW FRAME DOORS.
<br />¢U¢ _
<br />NOTE: Y = 4'-0" MIN.; I W 12. EVERY REQUIRED ENTRANCE OR PASSAGE DOORWAY SHALL BE
<br />Y= 4'-6" MIN. IF DOOR HAS A LATCH APPROACH, PULL SIDE Q NOT LESS THAN 3IN WIDTH AND NOT LESS THAN 6-8" IN HEIGHT.
<br />CLOSER Q INSULATE HOT WATER DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES
<br />AND SHALLE
<br />DD � PIPES AND DRAIN TO DOORWAY IS NOT° LESS THAN 32AT THE CLEAR WIDTH OF THE
<br />O PREVENT CONTACT
<br />L- 13. WHERE A PAIR OF DOORS IS UTILIZED, AT LEAST ONE OF THE
<br />LINE OF REQUIRED DOORS SHALL PROVIDE A CLEAR, UNOBSTRUCTED OPENING
<br />CLEARANCE WIDTH OF 32" WITH THE LEAF POSITIONED AT AN ANGLE OF 90
<br />24 I MIRROR DEGREES FROM ITS CLOSED POSITION.
<br />I 22 I } MIN. I \ 14. IDENTIFY ACCESSIBLE ENTRANCES WITH AT LEAST ONE }
<br />STANDARD SIGN AND WITH ADDITIONAL DIRECTIONAL SIGNS, AS
<br />MIN. I I REQUIRED, VISIBLE FROM APPROACHING PEDESTRIAN WAYS.
<br />U 15, THE FLOOR OR LANDING ON EACH SIDE OF AN ENTRANCE OR
<br />PASSAGE DOOR SHALL BE LEVEL AND CLEAR, THE LEVEL AND
<br />L _ _ L — I I CLEAR AREA SHALL HAVE A LENGTH IN THE DIRECTION OF DOOR —%
<br />- SWING OF AT LAST 60" AND THE LENGTH OPPOSITE THE
<br />o X DIRECTION OF DOOR SWING OF 44" AS MEASURED AT RIGHT
<br />X > ANGLES TO THE PLANE OF THE DOOR IN ITS CLOSED POSITION. JAN 15 2015
<br />Q _ 1 (REFER TO ADA DRAWING FOR CLEARANCES BASED ON L
<br />NOTE: Y= 3'-6" MIN.; Z z o U x DIFFERENT APPROACHES)
<br />NOTE: Y = 3 6 MIN.; I � J rt J Cooper III AA-CO01315 STATE #AR-0010460
<br />Y= 4'-0" MIN. IF DOOR HAS A Y= 4'-0" MIN. IF DOOR HAS A Ir
<br />CLOSER CLOSER — — — — — — — L N a LU 16. FLOORS OR LANDINGS SHALL BE NOT MORE THAN 1/2" LOWER
<br />THAN THE THRESHOLD OF THE DOORWAY. CHANGE IN LEVEL REVISIONS
<br />48 0 0 BETWEEN 114" AND 1/2" SHALL BE BEVELED WITH A SLOPE NO
<br />GREATER THAN 1:2. NO. DESCRIPTION DATE
<br />HINGE APPROACH, PUSH SIDE LATCH APPROACH, PUSH SIDE 8" MIN. KNEE CLEARANCE 6"MAX. TOE CLR 17. TO ALERT THE VISUALLY IMPAIRED, MARK THE UPPER APPROACH
<br />AND THE LOWER TREAD OF EACH INTERIOR STAIR WITH A STRIP
<br />17" MIN. DEPTH OF CLEARLY CONTRASTING COLOR AT LEAST 2" WIDE PLACED
<br />PARALLEL TO AND NOT MORE THAN 1" FROM THE NOSE OF THE
<br />w STEP OR LANDING. THE STRIP SHALL BE OF A MATERIAL THAT IS
<br />z SLIP RESISTANT AS THE OTHER TREADS OF THE STAIR.
<br />Q
<br />18. CENTER ELECTRICAL RECEPTACLE OUTLETS NOT LESS THAN 15"
<br />X I Q ABOVE THE FLOOR OR WORKING PLATFORM.
<br />w
<br />cr w 19. SANITARY FACILITIES LOCATED ON AN ACCESSIBLE FLOOR OF A
<br />c p BUILDING SHALL BE ACCESSIBLE TO THE PHYSICALLY
<br />cn HANDICAPPED.
<br />48" MIN. z L a 17" MIN. 20. ENTRY TO SANITARY FACILITIES:
<br />A. 44" CLEAR AISLES OR CORRIDORS WHERE OCCUPANT
<br />LOAD IS 10 OR MORE.
<br />CLEAR B. DOORWAYS TO HAVE A 32" CLEAR OPENING.
<br />FLOOR C. ON APPROACH SIDE, PROVIDE A 60" CLEAR LEVEL SPACE
<br />\ Z I SPACE WHEN DOOR SWINGS TOWARD APPROACH AND 44" SPACE
<br />10"
<br />WHEN DOOR SWINGS AWAY FROM APPROACH. REFER TO
<br />ADA MAX• I _-0 z APPROACHENG S. FOR CLEARANCES BASED ON DIFFERENT DATE ISSUEDi 09/02/14
<br />co
<br />21. THE AMERICANS WITH DISABILITIES ACT (ADA) PROVIDES THAT REVIEWED BYi AC
<br />REACH RANGE _ _ _ _ _ _ ALTERATIONS TO A FACILITY MUST BE MADE IN SUCH A MANNER
<br />3 THE ALTERED
<br />PORTIONS OF THAT, TO THE MAXIM
<br />AC LITY ARE R EXTENT FEASIBLE, ADILY ACCESS ACCESSIBLE TO DRAWN BYi AC
<br />1/2" = 1'-0" 19" MAX. INDIVIDUALS WITH DISABILITIES. BANK AND GENERAL
<br />48" MIN. CONTRACTOR ACKNOWLEDGES THAT THE REQUIREMENTS OF DESIGNED BYi AC
<br />ADA WILL BE SUBJECT TO VARIOUS AND POSSIBLY
<br />CONTRADICTORY INTERPRETATIONS. THE ARCHITECT
<br />THEREFORE, WILL USE ITS BEST PROFESSIONAL EFFORTS TO WELLS FARGO BE#:
<br />INTERPRET ADA REQUIREMENTS AND OTHER FE
<br />LAVATORY DETAIL N 0 T USED DERAL, STATE
<br />AND LOCAL LAWS, RULES, CODES, ORDINANCES AND 108880
<br />7 REGULATIONS AS THEY APPLY TO THE PROJECT. THE
<br />1/2" = 1'-0" 8 1/2" = 1'-0" ARCHITECT, HOWEVER, CANNOT AND DOES NOT WARRANT OR
<br />48" MIN. GUARANTEE THAT WELLS FARGO WILL COMPLY WITH ALL
<br />00
<br />INTERPRETATIONS OF THE ADA REQUIREMENTS AND/ OR THE
<br />NOTE: OTHER FEDERAL, STATE AND LOCAL LAWS, RULES, CODES,
<br />GRAB BARS: THE HEIGHT OF THE TOILET TANK IMPACTS THE PLACEMENT OF ORDINANCES AND REGULATIONS AS THEY APPLY TO THE SHEET TITLE
<br />1 1/4" MIN. TO 1 1/2" DIA. MAX. SET 1 1/2" OFF WALL. TYP. GRAB BARS. DEPENDING ON THE TOILET MODEL/BRAND, GRAB PROJECT.
<br />FASTENERS AND WALL SUPPORTS SHALL BE PROVIDED TO SUPPORT A BARS MOUNTED AT THE MINIMUM HEIGHT MIGHT NOT ACHIEVE
<br />VERTICAL OR HORIZONTAL FORCE OF 250 POUNDS ALONG ANY POINT ON THE THE REQUIRED MINIMUM 1 1/2" BETWEEN THE TOP OF THE 22. THE SCOPE OF WORK INDICATED ON THESE DRAWINGS IS FOR
<br />GRAB BAR, FASTENER, MOUNTING DEVICE, OR SUPPORTING STRUCTURE, TOILET TANK AND THE BOTTOM OF THE REAR GRAB BAR. SPECIFIC ITEMS SELECTED BY WELLS FARGO FOR CUSTOMER
<br />_ — _ I NOTE 54" MINIMUM ACCESS TO GOODS AND SERVICES; NOTE THAT SOME AREAS
<br />—
<br />J DIMENSION FOR OF ACCESS HAVE NOT BEEN MODIFIED TO MEET ADA
<br />30" 36" MIN. 54" SIDE GRAB BAR
<br />REQUIREMENTS. ALL OTHER AREAS OF ADA UPGRADE THAT
<br />AMAYND BE ARE
<br />AT THIS TIME ARE NOT IN THIS CONTRACT ACCESSIBILITY
<br />24" MIN. 12"MIN. 12" 42" I AND ARE NOT INDICATED ON THESE DOCUMENTS. CONTACT
<br />WELLS FARGO PROJECT MANAGER FOR ADDITIONAL
<br />24" MAX. 48" MIN. I I 12 INFORMATION CONCERNING OTHER AREAS OF ADA SCOPE OF INFORMATION
<br />a o WORK.
<br />TOILET PAPER I PROVIDE FASTENERS AND WALL
<br />I gw
<br />.. z I O W REINFORCEMENT TO SUPPORT A
<br />—Q a N a I w Z 250# MIN LOAD.
<br />b T oLu
<br />W
<br />Z U) 1 1/4" TO 1 1/2" 1 1/2
<br />IL J M z CO Z
<br />z z o o SHEET NUMBER
<br />�— m ( c) 0 I NOTE: R
<br />ACV I O Q M O I NO FIXTURES OTHER THAN TOILET
<br />co PERMITTED IN THIS AREA.
<br />I— Glm2
<br />i t o r r o —
<br />48" MIN. NOTE: 7" MIN. TO 9" IMAX T GRAB BAR
<br />REAR GRAB BAR IS POSITIONED WITH RESPECT TO THE CENTERLINE
<br />OF THE TOILET. IF THE TOILET IS NOT LOCATED CORRECTLY THE /
<br />REAR GRAB BAR WILL BE OUT OF COMPLIANCE AS WILL THE TOILET. ADC PROJECT NUMBERI 14303
<br />TYPICAL DOOR OR GATE CLEARANCES CORRIDOR WIDTH SINGLE USER TOILET DETAIL NOTE GRAB�BAR DETAIL
<br />IN ACCESSIBLE HUNG COMPARTMENTS PROVIDE N. DEEPL j`r1J MIN. FOR WALL HUNG WATER CLOSETS AND 59" MIN. DEEP3/8" = 1'-0" 1/2" = 1'-0" 1/2" = V-0" MIN. FOR FLOOR MOUNTED WATER CLOSETS MEASURED1 1/2"
<br />PERPENDICULAR TO THE REAR WALL.
<br />
|