My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5440 Gall Blvd (2)
Zephyrhills
>
Building Department
>
Building Plans
>
5440 Gall Blvd (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 11:49:34 PM
Creation date
2/18/2025 3:30:29 PM
Metadata
Fields
Template:
Building Plans
Street #
5440
Location
Gall Blvd
Contractor
Austin Construction Group
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I I PLUMBING GENERAL NOTES 1 2 1 PLUMBING GENERAL NOTES 1 6 1 PLUMBING SCHEDULE I <br />1. ALL WORK UNDER THIS DIVISION WITH THE CODES AND STANDARDS AS LISTED ON <br />THE PROJECT DRAWINGS AND TO OTHER PERTINENT CODES MADE A PART OF SUCH <br />CODE BY REFERENCE. <br />2. TO THE BEST OF THE ENGINEERS KNOWLEDGE, THE PLANS COMPLY WITH THE <br />APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE -SAFETY <br />STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH <br />SECTION 110.8.4.4 OF THE FLORIDA BUILDING CODE AND 633 FLORIDA STATUES. <br />3. PLANS INDICATE THE SCHEMATIC LAYOUT AND LOCATION OF THE PLUMBING SYSTEM <br />COMPONENTS. UNLESS SPECIFIC DIMENSIONS ARE NOTED, THE ACTUAL LOCATION <br />OF THESE COMPONENTS SHALL BE DETERMINED IN THE FIELD IN COORDINATION WITH <br />THE WORK OF OTHER TRADES, THE USE OF MANUFACTURER'S SHOP DRAWINGS AND <br />SIMILAR CERTIFIED DATA. PLANS SHALL NOT BE SCALED. <br />4. NOTIFY THE ENGINEER OR HIS AUTHORIZED REPRESENTATIVE OF ANY DAMAGE TO <br />THE EXISTING INSTALLATION BEFORE PROCEEDING WITH WORK. <br />24. ALL SANITARY, VENT AND WATER PIPING SHALL BE TESTED BEFORE CONCEALED IN <br />ANY WAY. ALL JOINTS SHALL BE MADE DRIP TIGHT BEFORE BEING CONCEALED. <br />DOMESTIC WATER PIPING SHALL BE TESTED AT 1-1 /2 TIMES OPERATING PRESSURE OR <br />100 PSI, WHICH EVER IS GREATER. <br />25. DISINFECT POTABLE WATER SYSTEM PER THE FBC. PROVIDE DOCUMENTATION IN THE <br />CLOSE OUT DOCUMENTS. <br />26. PIPING TO THE INLET OF A WATER HEATER AND PIPING CONVEYING WATER HEATED <br />BY A WATER HEATER SHALL BE INSULATED IN ACCORDANCE WITH SECTION C404.4 <br />OF THE FLORIDA BUILDING CODE, ENERGY CONSERVATION. <br />1 3 1 CODE CRITERIA <br />5. WHERE THE CEILING SPACE IS USED AS A RETURN AIR PLENUM, ALL PLUMBING WORK <br />IN THAT SPACE SHALL COMPLY WITH THE REQUIREMENTS OF NFPA-70 (NED) AS IT NOTE: <br />RELATES TO THAT APPLICATION. THE USE OF PVC WITHIN THE PLENUM IS STRICTLY ALL CODES SHALL COMPLY WITH THE FLORIDA STATUES 69A-3.012 AND THE STATE FIRE <br />PROHIBITED. COORDINATE WITH OTHER INSTALLERS TO PREVENT THE INSTALLATION MARSHALL'S RULE. THIS LIST IS NOT INCLUSIVE OF ALL CODES AND STANDARDS THAT <br />OF PROHIBITED MATERIALS. MAY OR MAY NOT APPLY TO THIS PROJECT. <br />6. SUBMIT SHOP DRAWINGS OF ALL FIXTURES AND MATERIALS FOR REVIEW BY OWNER. <br />INSTALL AND TEST ALL REQUIREMENT AND MATERIALS IN ACCORDANCE WITH THE <br />MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. SUBMIT DRAWINGS <br />AND CUT SHEETS FOR ALL PRODUCTS ALL AT ONE TIME. INDEX ALL ITEMS TO THE <br />PROJECT MANUAL OR DRAWINGS AS APPLICABLE. SHOP DRAWINGS THAT DEVIATE <br />FROM THE REQUIREMENTS OF THE CONTRACT DOCUMENTS SHALL LIST ALL <br />DIFFERENCES IN A COVER LETTER ATTACHED TO TOP OF T5HE SUBMITTAL. <br />7. PIPING AND OTHER ITEMS OF THE PLUMBING SYSTEM SHALL BE SUPPORTED DIRECTLY <br />FROM THE BUILDING STRUCTURE AND NOT FROM THE CEILING, CEILING SUSPENSION <br />SYSTEM, DUCTWORK, PIPING, OR ELECTRICAL SYSTEMS. <br />8. HANGERS, ANCHORS AND SUPPORTS SHALL SUPPORT THE PIPING AND CONTENTS OF <br />THE PIPING HANGERS AND STRAFING MATERIALS SHALL BE OF APPROVED MATERIALS <br />THAT WILL NOT PROMOTE GALVANIC ACTIONS. PROVIDE PIPE SADDLES BELOW <br />INSULATED PIPES. <br />9. HANGERS AND ANCHORS SHALL BE ATTACHED TO THE BUILDING CONSTRUCTION IN <br />AN APPROVED MANNER. <br />10. PROVIDE ALL OFFSETS AND FITTINGS REQUIRED FOR A FULLY FUNCTIONAL SYSTEM. <br />MAKE CONNECTION TO SITE UTILITIES. COORDINATE WITH SITE UTILITY CONTRACTOR <br />AS REQUIRED. <br />11. CONCEAL PIPING ABOVE CEILING, WITHIN WALL OR CHASES OR AS SPECIFICALLY <br />NOTED. <br />12. ALL EXPOSED PIPE AND FITTINGS IN FINISHED AREAS SHALL BE CHROME PLATED. IF <br />PIPING IS NOT AVAILABLE CHROME PLATED, PIPING SHALL BE PAINTED WITH <br />CHROME COLORED PAINT. <br />13. COORDINATE PIPING WITH ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMERS, <br />ECT.) PRIOR TO ANY INSTALLATION. DO NOT ROUTE ANY PIPING OVER ANY <br />ELECTRICAL DEVICES. <br />14. ALL WALL MOUNTED LAVATORIES SHALL BE ATTACHED TO FLOOR MOUNTED <br />CARRIERS. <br />15. PRIOR TO ANY EXCAVATION OR DEMOLITION, THE CONTRACTOR SHALL <br />COORDINATE HIS WORK WITH OTHER TRADES. <br />16. THE LOCATIONS OF ALL CLEANOUTS, VALVES, GAUGES, ECT. SHALL BE LOCATED FOR <br />ACCESS AND/OR SERVICE IN REFERENCE TO THE FINISHED BUILDING. REFER TO THE <br />DRAWINGS FOR APPLICABLE DETAILS. WALL CLEANOUT SHALL BE 18" A.F.F. <br />17. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND ROUGHING <br />DIMENSIONS OF ALL PLUMBING FIXTURES, DRAINS, ECT. <br />18. DIELECTRIC UNIONS SHALL BE INSTALLED AT ALL CONNECTIONS OR DISSIMILAR <br />METALS (SUCH AS COPPER TO GALVANIZED STEEL,) <br />19. WASTE AND SOIL PIPING SHALL BE PVC TYPE DWV AND SHALL CONFORM TO ONE <br />OF THE FOLLOWING STANDARDS: ASTM D 2665, ASTM D 2949 OR CSA B181.2. FITING <br />SHALL BE PVC AND SHALL CONFORM TO ONE OF THE FOLLOWING STANDARDS: <br />ASTM D 2665, ASTM D 3311 OR ASTM F 1866. JOINTS SHALL BE SOLVENT CEMENTING. <br />A PURPLE PRIMER THAT CONFORMS TO ASTM F 656 SHALL BE APPLIED TO JOINT <br />SURFACES (CLEAN AND FREE FROM MOISTURE). SOLVENT CEMENT NOT PURPLE IN <br />COLOR AND COFMING TO ASTM D 2564 OR CSA B137.3 SHALL BE APPLIED TO ALL <br />JOINT SURFACES. JOINTS SHALL BE IN ACCORDANCE WITH ASTM D 2855. SLOPE ALL <br />SANITARY PIPING 3" TO 6" AT A MINIMUM SLOPE OF g' PER FOOT <br />20. HOT AND COLD WATER PIPING SHALL BE CPVC AND SHALL CONFORM TO NSF 61 <br />AND ONE OF THE FOLLOWING STANDARDS, ASTM B 75, ASTM B 88, ASTM B 251, OR <br />ASTM B 447. FITTINGS SHALL BE COPPER OR COPPER ALLOY AND SHALL CONFORM <br />TO NSF 61 AND ONE OF THE FOLLOWING STANDARDS ASME B16.15, ASME B16.18, <br />ASME B16.23, ASME B16.23, ASME B16.26 OR ASME B16.29. SOLDERED JOINTS SHALL <br />BE MADE IN ACCORDANCE WITH THE METHODS OF ASTM B828. THE JOINING OF <br />WATER SUPPLY SHALL BE 95 LEAD FREE SOLDER AND THE SOLDER SHALL CONFORM <br />TO ASTM B 32. <br />21. PROVIDE VALVES WHERE INDICATED ON PLAN AND NECESSARY FOR PROPER <br />SYSTEM OPERATION AND COMPONENT ISOLATION. PROVIDE VALVES RATED FOR 125 <br />PSI OR GREATER WORKING PRESSURE IN WATER PIPING. PROVIDE LEAD FREE BRONZE <br />VALVES. BALL VALVES SHALL BE TWO-PIECE BODY, FULL PORT, WITH STAINLESS STEEL <br />BALL. <br />22. SLOPE ALL SANITARY PIPING 3" TO 6" AT A MIN. SLOPE OF 1 /8" PER FOOT. ALL <br />SANITARY PIPING 2-1/2" AND SMALLER SHALL BE SLOPED AT A MIN. OF 1 /4" PER <br />FOOT. <br />23. ALL EXPOSED PIPING UNDER ACCESSIBLE LAVATORIES SHALL BE INSULATED WITH <br />PROTECTIVE UNDER -SINK PIPE COVER AND PLUMBING ENCLOSURES AS <br />MANUFACTURE SPECIFICATIONS. <br />- FLORIDA BUILDING CODE (FBC), EIGHTH EDITION (2023) - ALL SECTIONS <br />- FLORIDA BUILDING CODE (FBC), EIGHTH EDITION (2023) - PLUMBING <br />- FLORIDA FIRE PREVENTION CODE 2023 <br />NATIONAL FIRE PROTECTION ASSOCIATION (NFPA): <br />- NFPA-70 (2020) NATIONAL ELECTRICAL CODE <br />NFPA-72 (2019) NATIONAL FIRE ALARM CODE <br />- NFPA-90A (2021) STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND <br />VENTILATING SYSTEMS <br />NFPA-90B (2021) STANDARD FOR THE INSTALLATION OF WARM AIR HEATING AND <br />AIR CONDITION SYSTEMS <br />AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS, <br />INC (ASHRAE): <br />- ASHRAE GUIDELINES 4-2019 - PREPARATION OF OPERATING AND MAINTENANCE <br />DOCUMENTATION FOR BUILDING SYSTEMS <br />- ASHRAE STANDARD 62.1-2019 AND APPROVED ADDENDA - VENTILATION FOR <br />ACCEPTABLE INDOOR AIR QUALITY <br />- ASHRAE STANDARD 126-2020 - METHOD OF TESTING HVAC AIR DUCTS <br />- ASHRAE STANDARD 180-2018 -STANDARD PRACTICE FOR INSPECTION AND <br />MAINTENANCE OF COMMERCIAL BUILDING HVAC SYSTEMS <br />4 1 ABBREVIATIONS <br />SYMBOL DESCRIPTION <br />AFF <br />ABOVE FINISHED FLOOR <br />CFM <br />CUBIC FEET PER MINUTE <br />CO <br />CLEAN OUT <br />BLDG <br />BUILDING <br />DIA <br />DIAMETER <br />ELEV <br />ELEVATION <br />EQUIP <br />EQUIPMENT <br />GPM <br />GALLON PER MINUTE <br />PVC <br />POLYVINYL CHLORIDE PIPE <br />FLEX <br />FLEXIBLE <br />GALV <br />GALVANIZED <br />VTR <br />VENT THRU ROOF <br />5 1 PLUMBING LEGEND & SYMBOLS <br />H W H W H W H W <br />n <br />COLD WATER (CPVC) <br />HOT WATER (CPVC) <br />SANITARY SOIL & WASTE (PVC) <br />SANITARY SOIL & VENT (PVC) <br />GAS LINE (BLACK IRON) <br />PIPE DROP <br />PIPE RISE <br />HANGER SPACING <br />MAXIMUM HORIZONTAL <br />MAXIMUM HORIZONTAL <br />PIPING MATERIAL <br />SPACING (FEET) <br />SPACING (FEET) <br />COPPER OR COPPER -ALLOY <br />TUBING 1-1/4" DIAMETER <br />6 <br />10 <br />AND SMALLER <br />COPPER OR COPPER -ALLOY <br />TUBING 1-1/2" DIAMETER <br />10 <br />10 <br />AND LARGER <br />PVC PIPE <br />4 <br />10 <br />PLUMBING SCHEDULE <br />MARK <br />QTY <br />ORDER <br />BY <br />SUPPLIED <br />BY <br />INSTALL <br />BY <br />DESCRIPTION <br />MANUFACTURER <br />MODEL # <br />FAUCET <br />WATER SUPPLY <br />DRAIN <br />COMMENTS <br />P1 <br />2 <br />OWNER <br />OWNER <br />G.C. <br />HAND SINK <br />ATOSA USA, INC. <br />MRS-HS-18(W) (OR EQUAL) <br />INCLUDED <br />2' HOT AND COLD <br />2" <br />INSTALL PER MANUFACTURER <br />P2 <br />1 <br />OWNER <br />OWNER <br />G.C. <br />THREE (3) COMPARTMENT SINK <br />ATOSA USA, INC. <br />MRSB-3-D (OR EQUAL) <br />T&S 5PR-8W 12 <br />2' HOT AND COLD <br />2" <br />INSTALL PER MANUFACTURER <br />P3 <br />1 <br />OWNER <br />OWNER <br />G.C. <br />COMPARTMENT (1) SINK <br />ATOSA USA, INC. <br />MRSA-11 (OR EQUAL) <br />T&S 5PR-8W12 <br />2' HOT AND COLD <br />2" <br />INSTALL PER MANUFACTURER <br />P4 <br />1 <br />EX. <br />EX. <br />EX. <br />GREASE TRAP <br />EXISTING <br />EXISTING <br />- <br />- <br />- <br />EXISTING +/- 1,000 GALLON CONCRETE TANK OUTSIDE OF BLDG. <br />P5 <br />1 <br />EX. <br />EX. <br />EX. <br />WATER HEATER <br />EXISTING <br />EXISTING <br />- <br />EXISTING <br />- <br />EXISTING GAS WATER HEATER OUTSIDE OF BLDG. <br />P6 <br />1 <br />EX. <br />EX. <br />EX. <br />MOP SINK <br />EXISTING <br />EXISTING <br />- <br />EXISTING <br />EX. <br />EXISTING MOP SINK TO BE UTILIZED <br />P7 <br />1 <br />G.C. <br />G.C. <br />G.C. <br />MOP SINK <br />PROFLO <br />PFMB2424 (OR EQUAL) <br />PF1 119 <br />HOT AND COLD <br />3" <br />INSTALL PER MANUFACTURER <br />F.S. <br />2 <br />G.C. <br />G.C. <br />G.C. <br />FLOOR SINK <br />ZURN <br />FD2376-NH3-H (OR EQUAL) <br />- <br />- <br />3" <br />12"X12" FLOOR SINK FOR 3 COMPARTMENT SINK <br />F.D. <br />2 <br />G.C. <br />G.C. <br />G.C. <br />FLOOR DRAIN <br />ZURN <br />ZN415-2NL-5B-P (OR EQUAL) <br />- <br />- <br />3" <br />3" PUSH ON FLOOR DRAIN <br />AM �® <br />fiff AV <br />ENGINEERING & CONSTRUCTION <br />AUSTIN CONSTRUCTION GROUP <br />2706 STALLONE DRIVE <br />TAMPA, FLORIDA 33605 <br />(813) 293-8883 <br />FLORIDA PE 48917 192169 - <br />CGC1521407 - CUC1224196 - <br />C F C 1430334 - F P C 15-4000052 <br />PROJECT INFORMATION: <br />CLIENT: <br />RICHARD KAZBOUR <br />PROJECT NAME: <br />HUNGRY HOWIES RESTAURANT <br />ADDITION <br />PROJECT LOCATION: <br />5440 GALL BLVD <br />ZEPHYRHILLS, FL 33542 <br />SEAL: <br />```�1� i 1l I I I►I //4 <br />Go ATS <br />�� E ••.. �� <br />.` •.• NS <br />.�co.• •. �� <br />:. • -- <br />FL COA NO. 30178 <br />ENGINEER OF RECORD <br />FL LICENSE NO. <br />TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE <br />PLANS AND SPECIFICATIONS COMPLY WITH THE <br />APPLICABLE MINIMUM BUILDING CODES <br />REVISIONS: <br />NO. <br />DATE <br />COMMENTS <br />SHEET TITLE: <br />PLUMBING <br />NOTES & SCHEDULE <br />SHEET INFORMATION: <br />DRAWN: A.C. <br />SHEET NO. <br />DATE: 7/22/2024 <br />CHECKED: K.C. <br />DATE: 7/22/2024 <br />Po . 1 <br />PROJECT NUMBER: <br />SCALE: <br />INDEX: <br />AS SHOWN <br />