Laserfiche WebLink
-M <br />MECHANICAL / PLUMBING DEMOLITION PLAN <br />1/8" = V-0" <br />PLUMBING LEGEND <br />ALL SYBOLS SHOWN MAY NOT APPEAR IN ALL DRAWINGS. <br />SYMBOLS ARE SHOWN SCHEMATIC AND MAY NOT BE TO SCALE. <br />SYMBOL <br />DESCRIPTION <br />— <br />DOMESTIC COLD WATER PIPING (CW) <br />— — — <br />DOMESTIC HOT WATER PIPING (HW) <br />— — — — — <br />DOMESTIC HOT WATER RETURN PIPING (HWR) <br />—Q <br />PIPING UP <br />PIPING DOWN <br />�— <br />DIRECTION OF FLOW <br />04 <br />GATE VALVE (GV) <br />BALL VALVE <br />TEMPERATURE AND PRESSURE RELIEF VALVE (T&P) <br />►Pi <br />PRESSURE REDUCING VALVE (PRV) <br />SS <br />SANITARY SEWER PIPING <br />— — — — — — — <br />SANITARY VENT PIPING <br />-00 <br />P-TRAP <br />FLOOR DRAIN OR FLOOR SINK W/ P-TRAP (FD) <br />—30 <br />HUB DRAIN W/ P-TRAP (HD) <br />tr,l FCO/ <br />FLOOR CLEANOUT OR GRADE CLEANOUT <br />WOO <br />CLEANOUT OR WALL CLEANOUT <br />NEW CONNECTION TO EXISTING <br />PLUMBING ABBREVIATIONS <br />AAV AIR ADMITTANCE VALVE DS DOWNSPOUT <br />AFF ABOVE FINISH FLOOR GC GENERAL CONTRACTOR <br />AFG ABOVE FINISH GRADE PRV PRESSURE REDUCING VALVE <br />A/C ABOVE CEILING RPZ-BFP REDUCED PRESSURE ZONE BFP <br />B/F BELOW FLOOR SS SANITARY SEWER <br />BFF BELOW FINISH FLOOR TP TRAP PRIMER <br />BFP BACKFLOW PREVENTER V PLUMBING VENT <br />B/G BELOW GRADE VTR VENT THRU ROOF <br />DCV-BFP DUAL CHECK VALVE BFP W WASTE <br />r� <br />EXISTING <br />VTR I <br />I � j <br />I 13"V <br />I I �''3"V <br />I Ii� <br />y LAV <br />i <br />i <br />3"V <br />I � • <br />I <br />I <br />311V� <'4 <br />STING <br />S <br />4"SS <br />3"W <br />3"FD <br />W/TP <br />/_ EXISTING <br />4 SANITARY RISER DIAGRAM <br />M1-1 NTS <br />PLUMBING FIXTURE SCHEDULE <br />ROUGH -IN SIZE <br />ITEM <br />DESCRIPTION <br />FIXTURE MANUFACTURER <br />FITTING MANUFACTURER <br />REMARKS <br />AND MODEL NUMBER <br />AND MODEL NUMBER <br />CW <br />HW <br />SAN <br />HWC <br />WATER CLOSET (HANDICAP) <br />ZURN Z5562 <br />ZURN Z5955SS-EL SEAT <br />1/2" <br />- <br />4" <br />1, 2, 4 <br />WC <br />WATER CLOSET <br />ZURN Z5572 <br />ZURN Z5955SS-EL SEAT <br />1/2" <br />- <br />4" <br />2,4 <br />LAV <br />LAVATORY (WALL -HUNG) <br />AMERICAN STANDARD COMRADE 0124 <br />ZURN Z7440-FC FAUCET <br />1/2" <br />1/2" <br />1-1/4" <br />1, 3, 4, 5, 6, 7 <br />REMARKS: <br />1. ADA COMPLIANT. <br />2. DUAL FLUSH (1.6/1.0 GPF), PRESSURE ASSISTED, TANK TYPE. <br />3. FAUCET: ADA COMPLIANT, SINGLE LEVER HANDLE, 0.5 GPM VANDAL RESISTANT AERATOR. <br />4. SUPPLIES: CHROME PLATED BRASS ANGLE TYPE SUPPLY KIT WITH WHEEL HANDLE & 12" RISER. <br />5. P-TRAP: 17 GAUGE CHROME PLATED CAST BRASS, ADJUSTABLE, WITH CLEANOUT PLUG. <br />6. DRAIN & SUPPLY COVERS: TRUEBRO LAV GUARD. <br />7. PROVIDE WITH LAVATORY CARRIER. <br />i"HW DOWN Y2"HW DOWN <br />Yz"CW DOWN iz"CW DOWN <br />�/z"CW <br />f <br />T� I _gip Iro <br />LAV WCHWC LAV <br />2 PLUMBING PLAN - WATER <br />M1-1 1/4" = V-0" <br />EXIST. 4"SS B/G <br />(FIELD VERIFY) <br />30*0"�PLUMBING PLAN - SANITARY <br />M1-1 1/4" = V-0" <br />FAN SCHEDULE <br />ITEM <br />TYPE <br />SERVICE <br />CFM <br />ESP <br />DRIVE <br />RPM <br />HP <br />VOLT/0 <br />MANUFACTURER <br />REMARKS <br />IN WC <br />TYPE <br />AND MODEL NUMBER <br />EF-1 & EF-2 <br />CEILING EXHAUST <br />TOILET ROOM <br />75 <br />0.250 <br />DIRECT <br />700 <br />50W <br />120/1 <br />GREENHECK SP-690 <br />1, 2, 3 <br />REMARKS: <br />1. INTEGRAL BACKDRAFT DAMPER. <br />2. INTEGRAL DISCONNECT. <br />3. INTERLOCK FAN WITH TOILET ROOM LIGHT; SEE ELECTRICAL DRAWING. <br />KEYED NOTES: <br />OREMOVE AND DISPOSE OF THE EXISITNG WATER CLOSETS, LAVATORIES, AND <br />ASSOCIATED PIPING & FITTINGS. CAP PIPING BELOW FLOOR AND ABOVE CEILING. <br />0 REMOVE AND DISPOSE OF THE EXISITNG EXHAUST FANS; DUCTWORK SHALL REMAIN <br />FOR USE WITH THE NEW FANS. LOCATE THE NEW EXHAUST FANS (EF-1 & EF-2) <br />ABOVE THE NEW WATER CLOSETS, AND CONNECT THE 6"0 EXHAUST DUCTS TO <br />EXISTING (ABOVE THE CEILING) - FIELD VERIFY LOCATION. <br />OCONNECT NEW 1/2" HOT & COLD WATER LINES (ABOVE CEILING) TO EXISTING. <br />FIELD VERIFY EXACT LOCATION PRIOR TO CONSTRUCTION. <br />OCONNECT THE NEW 4"SS LINES TO EXISTING. FIELD VERIFY EXACT LOCATION PRIOR <br />TO CONSTRUCTION. <br />OCONNECT 3"V (ABOVE CEILING) TO EXISTING VENT STACK. FIELD VERIFY EXACT <br />LOCATION. <br />SPECIFICATIONS: <br />GENERAL <br />SCOPE: THE INTENT OF THE SPECIFICATIONS AND THE DRAWINGS IS TO PROVIDE <br />COMPLETE AND FULLY OPERATIONAL SYSTEMS. FURNISH AND INSTALL ALL LABOR, <br />MATERIAL AND EQUIPMENT NECESSARY TO COMPLETE THE WORK. <br />SITE EXAMINATION: THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, DUCTWORK <br />AND PIPING WILL BE INSTALLED, AND REPORT ANY CONDITION THAT, IN THE <br />CONTRACTOR'S OPINION, PREVENTS THE PROPER INSTALLATION OF THE WORK. <br />STANDARDS: EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE <br />PROVISIONS OF ARL, ASME, ASTM, UL, ASHRAE, SMACNA, NEMA, ANSI, NFPA, AS <br />APPLICABLE TO EACH INDIVIDUAL UNIT, ASSEMBLY OR SYSTEM. <br />CODES: ALL WORK PERFORMED SHALL BE IN COMPLIANCE WITH THE FLORIDA BUILDING <br />CODE AND ALL OTHER APPLICABLE LOCAL CODES AND ORDINANCES OF THE AUTHORITY <br />HAVING JURISDICTION. IN CASE OF CONFLICT BETWEEN THE DRAWINGS/SPECIFICATIONS <br />AND THE CODES AND ORDINANCES, THE HIGHEST STANDARD SHALL APPLY. <br />PROVIDE ELECTRIC DISCONNECT SWITCHES FOR EACH PIECE OF POWERED EQUIPMENT IF <br />NOT SHOWN TO BE PROVIDED ON THE ELECTRICAL DRAWINGS. FUSED OR NON -FUSED <br />TYPE SHALL BE INSTALLED BASED UPON EQUIPMENT CHARACTERISTICS, MANUFACTURER'S <br />RECOMMENDATIONS, AND THE ELECTRICAL DRAWINGS. <br />SUBMITTALS: SUBMIT SHOP DRAWINGS AND PRODUCT DATA FOR ALL MATERIAL AND <br />EQUIPMENT SPECIFIED AND SCHEDULED ON THE DRAWINGS. PURCHASING AND <br />FABRICATION SHALL NOT OCCUR UNTIL SUBMITTALS HAVE BEEN REVIEWED. INCLUDE ALL <br />REQUIRED PRODUCT & MATERIAL DATA. <br />PERMITS AND FEES: CONTRACTOR(S) SHALL PROCURE AND PAY FOR ALL PERMITS, FEES <br />AND INSPECTIONS NECESSARY TO COMPLETE THE WORK. <br />WARRANTY: CONTRACTOR(S) SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE <br />OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE <br />DATE OF FINAL ACCEPTANCE BY THE OWNER AND SHALL REPAIR OR REPLACE ANY <br />DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING <br />WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND <br />WORKMANSHIP. <br />1I4 UM1.300, <br />WATER PIPING ABOVE GROUND SHALL BE TYPE "L" HARD DRAWN COPPER TUBE PER ASTM <br />B88, WITH SOLDER TYPE WROUGHT COPPER FITTINGS. <br />WASTE & VENT PIPING ABOVE GROUND SHALL BE NO -HUB CAST IRON SOIL PIPE PER CISPI <br />STANDARD 301, OR DWV COPPER TUBE PER ASTM B306. <br />WASTE & VENT PIPING BELOW GROUND SHALL BE HUB -AND -SPIGOT CAST IRON SOIL PIPE <br />AND FITTINGS PER ASTM A74. JOINTS SHALL HAVE RUBBER GASKETS CONFORMING TO <br />ASTM C564. <br />WASTE & VENT PIPING MAY BE SCHEDULE 40 PVC-DWV PIPE WITH SOLVENT WELD DWV <br />FITTINGS PER ASTM D2665 & D1785, IF ACCEPTABLE TO THE LOCAL AUTHORITY HAVING <br />JURISDICTION. <br />FLOOR DRAIN: ZURN Z4156, POLISHED NICKEL BRONZE STRAINER, 1/2" TRAP PRIMER <br />CONNECTION. <br />FLOOR CLEANOUT: ZURN Z1400 ADJUSTABLE CLEANOUT, CAST IRON BODY, POLISHED <br />BRONZE HEAVY DUTY TOP. <br />0191"KNIT01111 <br />DUCTWORK SHALL BE RIGID SHEETMETAL CONSTRUCTED FROM GALVANIZED SHEET <br />STEEL. DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH THE <br />CURRENT SMACNA DUCT CONSTRUCTION STANDARDS. DUCTWORK SHALL BE ROUND OR <br />RECTANGULAR, AS SHOWN ON THE PLAN. PROVIDE ALL REQUIRED TRANSITIONS, <br />CONNECTIONS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE OPERATING <br />SYSTEM. <br />DUCT SEALANT: SEAL ALL LONGITUDINAL AND TRANSVERSE JOINTS WITH A <br />NON -HARDENING, NOWMIGRATING MASTIC OR LIQUID ELASTIC SEALANT OF A TYPE <br />RECOMMENDED BY THE MANUFACTURER FOR SEALING JOINTS AND SEAMS IN SHEET <br />METAL DUCTWORK. COVER ALL FIELD JOINTS AND FASTENING SCREWS WITH MASTIC. <br />tJE1S <br />Florida Certificate of Authorization #28010 <br />1349 West Peachtree Street, NE <br />Atlanta, GA 30309 <br />Phone: (404) 873-3697 <br />Fax: (678)904-1510 <br />�a pAVt �• <br />a - <br />• • w <br />• • w <br />• • w <br />S A► A OP <br />' v►�,r <br />• <br />John David AddisonAL E <br />Seal: PE #59239 Seal: •iq��� <br />Consultant: <br />CBRE BANK OF AMERICA <br />CEI RICHARD ELLIS <br />BU* 0f 6700 Lakeview Center <br />41WDrive <br />Second Floor <br />Client: Tampa, Florida 33619 <br />Permit Set _ 11 25 09 <br />Client Review__Set_ ____ 11 13 09 <br />Description: No: I By: Date: <br />BANK OF AMERICA ADA REMEDIATION <br />Zephyrhills Location <br />5632 Gall Boulevard <br />Zephyrhills, Florida 33539 <br />Project Title & Address: <br />MECHANICAL / PLUMBING <br />PLAN <br />Sheet Title: <br />Proj. No. <br />09.00683.80 <br />Drawn By: <br />_ JC <br />M 1 _ <br />Checked By: <br />MC <br />SARAH ROLAND <br />_ <br />LL DI AMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED ON <br />SITE BY THE CONTRACTOR AND SUB -CONTRACTORS. THE PROJECT <br />MANAGER SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES PRIOR <br />TO PROCEEDING WITH THE WORK. <br />© NELSON <br />ALL RIGHTS RESERVED <br />