My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5632 Gall Blvd (4)
Zephyrhills
>
Building Department
>
Building Plans
>
5632 Gall Blvd (4)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2025 3:16:18 PM
Creation date
2/18/2025 3:32:18 PM
Metadata
Fields
Template:
Building Plans
Street #
5632
Location
Gall Blvd
Contractor
CAL DEV
Building Plans - Permit #
10094
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Y <br />r <br />1 A 4 Jl� /-SCOPE OF WORK GENERAL NOTES: <br />i <br />................................ ..... ...... <br />I <br />'� ELECTRICAL DEMOLITION PLAN <br />E 1/8" = V-0" <br />2 ELECTRICAL PLAN <br />El-1 1/8" = 1'-0" <br />I <br />I ( ■ <br />... ....J ......__ 3 1 <br />3 <br />■ <br />. <br />n_.—_.. .......... <br />.............. <br />1. THE E.C. SHALL WAKE SAFE' EXISTING WALLS AND CEILINGS BEING <br />REMOVED WHICH CONTAIN ELECTRICAL DEVICES SO THAT WALLS AND <br />CEILINGS MAY BE REMOVED BY DEMOLITION CONTRACTOR. <br />2. ANY ELECTRICAL DEVICES WHICH ARE LOCATED IN WALLS NOT <br />BEING REMOVED MAY BE LEFT INTACT. REROUTE AND RECONNECT <br />BRANCH CIRCUIT AS NECESSARY TO RE -ENERGIZE DEVICES LEFT <br />WITHOUT POWER DUE TO DEMOLITION; INCLUDING ADJACENT AREAS <br />THAT ARE NOT WITHIN PROJECT LIMITS, BUT ARE FED THROUGH THIS <br />PROJECT AREA. <br />3. REMOVE ANY EXISTING BRANCH PIPE AND WIRE OR LOW VOLTAGE <br />CABLING NOT BEING USED FROM THIS PROJECT AREA. <br />4. ALL WORK PERFORMED SHALL BE IN COMPLIANCE WITH THE NEC, <br />THE FLORIDA BUILDING CODE AND ALL OTHER APPLICABLE LOCAL <br />CODES OF THE AHJ. <br />KEYED NOTES: <br />ODISCONNECT AND REMOVE EXISTING VANITY LIGHT FIXTURES IN <br />RESTROOM. MAINTAIN EXISTING LIGHTING BRANCH CIRCUITING <br />FOR REUSE WITH NEW LIGHTING LAYOUT. REMOVE EXISTING <br />CONDUIT AND WIRING SERVING THESE FIXTURES BACK TO <br />NEAREST J-BOX. <br />ODISCONNECT AND REMOVE ALL EXISTING ELECTRICAL DEVICES <br />FROM WITHIN THIS AREA. DISCONNECT EXISTING RESTROOM <br />EXHAUST FAN FOR REMOVAL BY MECHANICAL CONTRACTOR. <br />ODISCONNECT AND REMOVE ALL EXISTING ELECTRICAL/FIRE ALARM <br />DEVICES IN WALLS BEING DEMOLISHED. <br />CONNECT NEW EXHAUST FAN TO EXISTING BRANCH LIGHT CIRCUIT <br />SERVING THIS ROOM. <br />OPROVIDE NEW V x 4' FLUORESCENT LIGHT FIXTURE WITH ONE T8 <br />LAMP WITH ELECTRONIC BALLAST AND CONNECT TO EXISTING <br />BRANCH LIGHTING CIRCUIT SERVING THIS AREA. PROVIDE NEW <br />WALL MOUNTED OCCUPANCY SENSOR AND CONNECT TO NEW <br />FIXTURE AND CEILING FAN FOR CONTROLS. PROVIDE NEW <br />CONDUIT AND WIRING FOR ALL NEW WORK. NEW FIXTURES AND <br />OCCUPANCY SENSORS SHALL MATCH BANK (BOA) STANDARDS. <br />i PROVIDE NEW GFI RECEPTACLE IN WALL AT 48" AFF. CONNECT TO <br />NEAREST 20A, 1P CIRCUIT FEEDING CONVENIENCE RECEPTACLES. <br />PROVIDE ALL NEW WIRING AND CONDUIT. <br />OPROVIDE NEW FIRE ALARM STROBE/VISUAL DEVICE. CONNECT TO <br />EXISTING BUILDING FIRE ALARM SYSTEM. NEW DEVICE SHALL <br />MATCH EXISTING AND BE COMPATIBLE WITH EXISTING FIRE ALARM <br />SYSTEM. <br />OPROVIDE NEW RECEPTACLE IN NEW WALL AT 18" AFF. CONNECT <br />TO 20A, 1P CIRCUIT FEEDING CONVENIENCE RECEPTACLES IN THIS <br />ROOM. PROVIDE ALL NEW WIRING AND CONDUIT. <br />OPROVIDE NEW CEILING MOUNTED SMOKE DETECTOR. CONNECT TO <br />EXISTING BUILDING FIRE ALARM SYSTEM. NEW DEVICE SHALL BE <br />COMPATIBLE WITH EXISTING FIRE ALARM SYSTEM. <br />ELECTRICAL LEGEND <br />- <br />EXISTING TO REMAIN <br />......EXISTING <br />TO BE REMOVED <br />II <br />— <br />( <br />--- <br />IE <br />I <br />NEW <br />� <br />I <br />1'x4' FLUORESCENT WRAPAROUND LIGHT <br />i <br />FIXTURE W/ 90 MIN. EMERGENCY BATTERY BACKUP <br />_J <br />WALL MOUNTED OCCUPANCY SENSOR <br />WATT STOPPER #DW-100 OR EQUAL <br />- <br />DUPLEX RECEPTACLE <br />a.1 <br />�..............._ <br />__ . <br />(� <br />GFCI DUPLEX RECEPTACLE <br />i <br />04 <br />FIRE ALARM VISUAL APPLIANCE <br />=;i <br />= <br />FIRE ALARM SMOKE DETECTOR <br />........................__........... 5 <br />\ <br />� <br />NaS <br />EXHAUST FAN MOTOR <br />Ir fl!) <br />EF <br />EXHAUST FAN <br />Scale: <br />0' 8' 16' 24' <br />NELSC�►N <br />Florida Certificate of Authorization #28010 1 <br />1349 West Peachtree Street, NE <br />Atlanta, GA 30309 <br />Phone: (404) 873-3697 <br />Fax: (678)904-1510 <br />. �V:* <br />.tea' <br />• <br />Vrd <br />OJohn David Addison �Seal: PE#59239 SLF������1�9 <br />Consultant: <br />CBRE BANK OF AMERICA <br />CB RICHARD ELLIS <br />Beek of 6700 Lakeview Center <br />Drive <br />Second Floor <br />Client: Tampa, Florida 33619 <br />BANK OF AMERICA ADA REMEDIATION <br />Zephyrhills Location <br />5632 Gall Boulevard <br />Zephyrhills, Florida 33539 <br />Project Title & Address: <br />ELECTRICAL PLAN <br />Sheet Title: <br />Proj. No.: <br />09.00683.80 <br />Drawn By: <br />Checked By: DA E 1 _ 1 <br />JA <br />P.M.. <br />SARAH ROLAND <br />ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED ON <br />SITE BY THE CONTRACTOR AND SUB -CONTRACTORS. THE PROJECT <br />MANAGER SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES PRIOR <br />TO PROCEEDING WITH THE WORK. <br />© NELSON ALL RIGHTS RESERVED <br />
The URL can be used to link to this page
Your browser does not support the video tag.