HVAC GENERAL NOTES <br />I. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL MATERIAL AND EQUIPMENT IN <br />STRICT ACCORDANCE WITH APPLICABLE CODES AND STANDARDS, AND PER <br />MANUFACTURER'S DIRECTIONS. <br />2. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL NECESSARY PERMITS, LICENSE, <br />INSPECTIONS, APPROVALS, AND FEES. <br />3. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL OTHER TRADES BEFORE <br />INSTALLATION OF ANY MATERIALS OR EQUIPMENT. <br />4. THESE DRAWINGS ARE DIAGRAMMATIC AND SHOW GENERAL LOCATION AND <br />ARRANGEMENT OF ALL MATERIALS AND EQUIPMENT. THE DRAWINGS SHALL BE <br />FOLLOWED AS CLOSELY AS BUILDING CONSTRUCTION AND ALL OTHER WORK WILL <br />PERMIT. <br />5. DO NOT SCALE DRAWINGS FOR MEASUREMENTS. <br />G. ALL DUCT DIMENSIONS SHOWN ARE INTERIOR DUCT DIMENSIONS. <br />7. ALL PENETRATIONS THROUGH EXTERIOR WALLS 4 ROOF SHALL BE FLASHED 4 <br />COUNTERFLASHED IN A WATERPROOF MANNER. (COLOR TO MATCH EXTERIOR). <br />8. SEAL ALL PENETRATIONS OF RATED WALLS WITH FIRE DAMPER, SEALANT MATERIAL <br />APPROVED BY LOCAL CODE. <br />q. ALL SUSPENDED MATERIALS AND EQUIPMENT SHALL BE INDIVIDUALLY SUPPORTED <br />FROM THE BUILDING STRUCTURE. DO NOT SUSPEND ITEMS FROM THE CEILING OR <br />ITS SUPPORT SYSTEM. <br />10. INSTALL ALL CONTROL DEVICES, INCLUDING THERMOSTATS AND SWITCHES, 4'-0" <br />ABOVE FINISHED FLOOR. PROVIDE THE REQUIRED DEVICES) FOR ALL SYSTEMS <br />WHETHER LOCATED ON THE PLANS OR NOT. <br />11. LOCATE CEILING DIFFUSERS IN ACCORDANCE WITH ARCHITECTURAL REFLECTED <br />CEILING PLANS (IF PROVIDED). <br />12. PROVIDE MANUFACTURER'S RECOMMENDED CLEARANCES AROUND MECHANICAL UNITS <br />FOR MAINTENANCE AND FILTER REMOVAL. <br />13. ALL PIPING AND DUCTWORK LOCATIONS SHALL BE COORDINATED W/ WORK UNDER <br />OTHER DIVISIONS OF THE SPECIFICATIONS, TO AVOID INTERFERENCE. <br />14. ALL SUPPLY AND RETURN DUCT SHALL BE INSULATED. CONCEALED SHEET METAL <br />DUCT MAY BE EXTERNALLY INSULATED WITH MINERAL FIBER BOARD OR BLANKET <br />OR MAY BE INTERNALLY INSULATED WITH DUCT LINER (R-VALUE = 5). THE <br />FIRST 15' FROM THE AIR HANDLER SHALL BE INTERNALLY LINED. INTERNALLY <br />LINED INSULATION SHALL MEET BACTERIOLOGICAL STANDARD ASTM C 665. <br />EXPOSED SPIRAL DUCTWORK DOES NOT REQUIRE INSULATION UNLESS PLANS SHOW <br />OTHERWISE (WHEN IN CONDITIONED SPACE). <br />15. CERTIFIED TEST AND BALANCE CONTRACTOR SHALL BALANCE SYSTEM TO AIR <br />QUANTITIES INDICATED ON PLANS AND PROVIDE OWNER'S REPRESENTATIVE WITH <br />COMPLETE BALANCE REPORT. IF BALANCING DAMPERS ARE NOT PROVIDED IN <br />RETURN DUCTWORK, CONTRACTOR SHALL BALANCE SUPPLY SIDE TO AIR <br />QUANTITIES INDICATED ON PLANS AND SHALL BALANCE OUTSIDE AIR AND RETURN <br />AIR FLOWS AT THE AIR HANDLER TO AIR QUANTITIES INDICATED IN THE SCHEDULE. <br />PROVIDE NEW AIR FILTERS FOR EACH UNIT. <br />16. AS REQUIRED BY LOCAL CODES, MECHANICAL CONTRACTOR SHALL PROVIDE U.L. <br />LISTED FIRE DAMPERS WHERE REQUIRED FOR FIRE PROTECTION REQUIREMENTS OF <br />THE NVAC SYSTEM * THE UL ASSEMBLY. <br />17. PROVIDE I YEAR WARRANTY ON ALL EQUIPMENT AND 5 YEAR WARRANTY ON ALL <br />COMPRESSORS. <br />18. ALL INTAKE OPENINGS SHALL BE LOCATED A MINIMUM OF 10'-0" FROM ALL EXHAUST <br />LOCATIONS. <br />Iq. ALL ACTUACTORS ON MOTORIZED DAMPERS, SMOKE DAMPERS, AND FIRE -SMOKE <br />DAMPERS ARE TO BE LOW VOLTAGE UNLESS OTHERWISE NOTED. <br />20. A COMPLETE SYSTEM OF SEISMIC RESTRAINTS SHALL BE DESIGNED BY MASON <br />INDUSTRIES 4 SEALED BY THEIR REGISTERED ENGR 4 INSTALLED BY THIS CONTR. <br />AS REQ'D BY APPLICABLE CODES FOR THE LOCALE OF THIS PROJECT. <br />21. CONDENSATE DRAIN PIPING SHALL BE SCHEDULE 40 PVC PIPE AND FITTINGS. <br />DRAINS FROM AIR HANDLING UNITS SHALL BE TRAPPED. <br />22. ALL MAIN DUCTWORK SHALL BE GALVANIZED SHEET METAL CONSTRUCTED IN <br />ACCORDANCE WITH SMACNA STANDARDS. RUNOUTS FROM MAIN/BRANCH DUCTS MAY <br />BE FLEXIBLE DUCT CONFORMING TO THE REQUIREMENTS OF UL 181 FOR CLASS I <br />FLEXIBLE AIR DUCTS. MAX 10' FLEX PER RUNOUT. <br />23. THE MECHANICAL CONTRACTOR SHALL PROVIDE LOW VOLTAGE CONTROL LINES TO <br />THE ROOFTOP UNIT. COORDINATE ROUTING AND INSTALLATION WITH THE GENERAL <br />CONTRACTOR. <br />24. ELECTRICAL CONTRACTOR TO PROVIDE ALL HIGH VOLTAGE ELECTRICAL WIRING, <br />CONDUIT, DISCONNECT SWITCHES, FUSES, ECT. TO ROOFTOP UNITS. ALL FINAL <br />ELECTRICAL CONNECTIONS ARE BY ELECTRICAL CONTRACTOR. <br />25. MECHANICAL CONTRACTOR SHALL VERIFY LOCATION OF ALL PENETRATIONS FOR <br />RELIEF HOODS, OUTSIDE AIR HOODS, LOUVERS, AND WALL CAPS WITH ARCHITECT <br />* OWNER PRIOR TO INSTALLATION. <br />26. MECHANICAL CONTRACTOR SHALL PAINT ALL RELIEF HOODS, INTAKE HOODS, <br />LOUVERS, AND VENT CAPS. CONFIRM COLOR WITH ARCHITECT It OWNER PRIOR TO <br />INSTALLATION. <br />27. EXISTING NVAC EQUIPMENT HAS BEEN ASSUMED TO BE IN GOOD WORKING ORDER. <br />ENGINEER AND MC ARE NOT RESPONSIBLE FOR OPERATIONAL PERFORMANCE OR <br />WARRANTY OF EXISTING EQUIPMENT. <br />25. MC SHALL PREPARE ALL EXPOSED DUCT, GRILLES, PIPING, AND UNITS FOR <br />PAINTING. GC WILL BE RESPONSIBLE FOR PAINTING, <br />29. MC SHALL CONSULT OWNER OR OWNER'S REP WITH REGARD TO ALL DEMO/REMOVED <br />EQUIPMENT FOR DISPOSAL, REUSE OR RESALE. <br />30. ALL CUTTING AND PATCHING OF WALLS AND FLOORS FOR MECHANICAL EQUIPMENT <br />SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR. <br />31. THE MECHANICAL CONTRACTOR SHALL COORDINATE THE REQUIRED OPENINGS IN ROOF <br />TRUSSES WITH THE G.C. IN ORDER TO PROVIDE ADEQUATE SPACE, ACCESS AND <br />SUPPORT FOR THE MECHANICAL UNIT. <br />32. THE GENERAL CONTRACTOR SHALL PROVIDE PLATFORMS AS REQUIRED FOR THE <br />INSTALLATION OF THE MECHANICAL UNIT, AND SUITABLE WALKING SURFACES AND <br />WORKING AREAS FOR ACCESS AND MAINTENANCE. THE MECHANICAL CONTRACTOR <br />SHALL COORDINATE THE REQUIREMENTS FOR THESE ITEMS WITH THE GENERAL <br />CONTRACTOR. <br />MECHANICAL LEGEND <br />18xl4n RECTANGULAR DUCT <br />( 110 ROUND METAL DUCT <br />6" <br />FLEX/RIGID ROUND DUCT <br />ELBOW WITH TURNING VANES <br />L_ <br />VOLUME DAMPER <br />`: - <br />SUPPLY TAP WITH VOLUME DAMPER <br />® <br />SUPPLY DIFFUSER/GRILLE <br />0 <br />RETURN REGISTER/GRILLE <br />® <br />VERTICAL SUPPLY DUCT <br />0 <br />VERTICAL RETURN DUCT <br />O <br />T-STAT <br />SD <br />DUCT SMOKE DETECTOR <br />® <br />REMOTE SENSOR <br />(WITH 4°F ADJ. SETPOINT) <br />Q <br />MECHANICAL EQUIPMENT <br />TYPE XX <br />® <br />CEILING EXHAUST FAN <br />�}- <br />3/4" DOOR UNDER CUT <br />PACKAGED HEAT PUMP ROOF <br />TOP UNIT SCHEDULE <br />SUPPLY - FAN DATA <br />HEATING <br />CAPACITY <br />COOLING <br />CAPACITY <br />ELECTRICAL. <br />DATA <br />UNIT <br />AREA <br />MANUFACTURER <br />UNIT <br />EER/ <br />UNIT <br />NOTES <br />MIN.EXT. <br />NO. <br />SERVED <br />TOTAL <br />O/A <br />S.P. <br />FAN <br />MOTOR <br />CAPACITY <br />AUX. ELEC <br />TOTAL <br />SQ�SIBLE <br />VOLT/PH <br />MAX <br />MCA <br />4 MODEL <br />TONNAGE <br />SEER <br />WEIC,HT(LBS) <br />CFM <br />CFM <br />1. <br />RPM <br />H.P. <br />MBH <br />KW <br />ME94 <br />MBH <br />FUSE <br />RTU-I <br />SEE PLANS <br />6000 <br />1400 <br />0.6" <br />MFG <br />5A <br />q0.2 <br />42.0 <br />180.8 <br />136.4 <br />208/30 <br />250 <br />235.0 <br />ARRI ER <br />15.0 <br />q.3 <br />2215 <br />1-8 <br />yRTU-2 <br />SEE PLANS <br />6000 <br />1400 <br />0.6" <br />MFG <br />5.q <br />90.2 <br />42.0 <br />180.8 <br />136.4 <br />20B/30 <br />250 <br />235.0 <br />ARRI ER <br />15.0 <br />q.3 <br />2215 <br />1-8 <br />NOTES: <br />I. <br />COOLING CAPACITIES ARE RATED IN ACCORDANCE WITH ARI STANDARD 210/2g0 AT 95*F AMBIENT OUTDOOR <br />5. ALL ACCESSORIES AND OPTIONS ARE TO BE FACTORY INSTALLED. <br />AIR TEMP., 80-F DRY BULB, 67' WET BULB ENTRANCE AIR TEMP., AND NOMINAL AIR QUANTITY LISTED. <br />6. PROVIDE SINGLE POINT ELECTRICAL CONNECTION. <br />2. PROVIDE 7-DAY PROGRAMABLE THERMOSTAT AND REMOTE SENSER FOR EACH <br />UNIT. <br />7. DUCT SMOKE DETECTOR TO BE PROVIDED BY E.C. AND INSTALLED BY M.C. <br />3. <br />PROVIDE FACTORY ROOF CURB AND AIR SIDE ECONOMIZER SECTION WITH BAROMETRIC <br />8. CATALOG NUMBERS AND MANUFACTURERS ARE TO INDICATE TYPE AND QUALITY OF <br />RELIEF DAMPER FOR EACH UNIT. <br />UNIT DESIRED. SUBMIT CUTSHEETS OF THESE AND ALTERNATE MANUFACTURERS <br />4. <br />PROVIDE NEW FILTERS FOR EACH UNIT AT TURNOVER TO OWNER. <br />FOR ARCHITECT AND OWNER APPROVAL PRIOR TO PURCHASE OF ANY UNITS. <br />INFORMATION ON ALTERNATE UNITS PROPOSED BY THE CONTRACTOR SHALL INCLUDE <br />THE ADD/DEDUCT ASSOCIATED WITH ACCEPTANCE OF THAT UNIT (OR THE <br />ALTERNATE PACKAGE AS A WHOLE). <br />DIFFUSER SCHEDULE <br />NEM <br />LE <br />E <br />FACTURODEL <br />SYMBOL <br />CFM <br />PATTERN <br />DAMPER <br />MATERIAL <br />SERVICE <br />FINISH <br />ER <br />NOTES <br />® <br />TAS NOTED <br />AS NOTED <br />2424 <br />LAY -IN <br />4-WAY <br />YES <br />STEEL <br />SUPPLY <br />NOTE 2 <br />PRICE SMD <br />I <br />© <br />AS NOTED <br />AS NOTED <br />2424 <br />SURFACE <br />4-WAY <br />YES <br />STEEL <br />SUPPLY <br />NOTE 2 <br />PRICE SMD <br />I <br />© <br />AS NOTED <br />AS NOTED <br />12x12 <br />SURFACE <br />4-WAY <br />YES <br />STEEL <br />SUPPLY <br />NOTE 2 <br />PRICE SMD <br />I <br />Op <br />AS NOTED <br />AS NOTED <br />2424 <br />LAY -IN <br />PERFORATED <br />YES <br />STEEL <br />RETURN <br />NOTE 2 <br />PRICE PDDR <br />I <br />O <br />AS NOTED <br />AS NOTED <br />2424 <br />SURFACE <br />PERFORATED <br />YES <br />STEEL <br />RETURN <br />NOTE 2 <br />PRICE PDDR <br />I <br />NOTES: <br />I. DIFFUSER DESIGNATIONS ON PLANS AS FOLLOWS: <br />2. <br />FINISH TO MATCH / BE ABLE <br />MATCH CEILING OR WALL OR DOOR <br />DIFFUSER OR <br />NECK SIZE. 8x4 DIFFUSER TYPE <br />A <br />AS NOTED ABOVE <br />AIR QUANTITY -�' 75 <br />ROOF TOP <br />AIR HANDLI <br />HIGH DENSI <br />GASKET 2' <br />PREFABRIC <br />ROOF CURE <br />2" RIGID IN <br />FLASHING <br />BUILT-UP F <br />SEAL ALL E <br />OPENINGS W <br />HARDENING <br />DUCT LINER FROM UNIT G.W.B. t I' RIGID INSULATION. v <br />DISCHARGE AND INTAKE. SEAL AND STAGGER ALL SEAMS. <br />HEAT PUMP ROOFTOP UNIT <br />NO SCALE <br />UNIT HEATER SCHEDULE <br />TAG LOCATION MOUNTING CAPACITY ELECTRICAL MTA MANUFACTURER t MOM NO. NOTES <br />MOM w V PH HZ <br />UH-1 STORAGE r-I jcx)r: 1nFn 25.6 7.5 208 3 60 MARKEL F3FUH07 1-4 <br />NOTES: <br />I. INTERNAL THERMOSTAT <br />2. MOUNT HEATER @ 8' A.F.F <br />3. UNIT DISCONNECT <br />4. U.L. LISTED <br />FAN SCHEDULE <br />UNIT SERVICE AM CFM S.P. RPM TYPE 4 MIN. MOTOR 14P MANUFACTURER DRIVE CONTROL SCHEME REMARKS <br />NO. SERVED ARRANGEMENT 4 VOLTAGE 4 MODEL NO. <br />EF-1 EXHAUST TOILETS 75 MIN 0.25" q50 CEILING 29 WATTS/0.58A GREEN14ECK DIRECT A 1-5 <br />120/1 0 5P-AI10 <br />NOTES: <br />I. SCREEN <br />2. BACKDRAFT DAMPER <br />3. COLOR BY ARCHITECT <br />4. INTEGRAL DISCONNECT SWITCH <br />5. SPEED CONTROLLER <br />CONTROL OPTIONS: <br />A. CONTROL W/ ROOM LIGHTS <br />ECONOMIZER HOOD WITH <br />FILTER ACCESS PANEL. <br />FRESH AIR INLET <br />I CONDENSATE <br />TO SPLASH BLOCK <br />IONIZATION TYPE SMOKE <br />DETECTOR TO SHUT DOWN UNIT <br />UPON ACTIVATION. FURNISHED BY E.C., <br />INSTALLED BY M.C. WIRED TO <br />FIRE ALARM SYSTEH BY E.C. <br />LOCATE WHERE INDICATED ON FLOOR <br />PLAN AND SCHEDULE. FOR ADDITIONAL <br />INFO, SEE ELECTRICAL PLANS. <br />AIR <br />FLOW <br />SPIN IN COLLAR WITH <br />INTERGRAL SCOOP <br />VOLUME DAMPER WITH <br />3/8" LOCKING QUADRANT <br />AND END BEARING. - <br />Charlotte, North Carolina 28203 <br />tel 704.373.0068 fax 704.373.0260 <br />MECHANICAL ELECTRICAL PLUMBING <br />° ook <br />-o <br />e <br />- e <br />STATE OF c <br />I a 01 \ e <br />♦♦ <br />of <br />i •°....• <br />LE SHEET METAL DUCT. <br />END BEARING <br />CIRCULAR CLAMP <br />FLEXIBLE DUCT. <br />NOTES: <br />I. SEE FLOOR PLANS AND SPECIFICATIONS <br />FOR DUCT INSULATION REQUIREMENTS. <br />2. TAP OFF TOP/SIDE/BOTTOM OF DUCT AS REQUIRED <br />BRANCH TAKEOFF TO SINGLE OUTLET <br />NO SCALE <br />HANGER <br />FAN <br />EXHAUST GRILLE CEILING <br />COLOR TO MATCH CEILING <br />3 EXHAUST FAN DETAIL <br />NO SCALE <br />EXHAUST DUCT <br />�o <br />N0 Lo't <br />NN0) <br />p <br />1 <br />(``,/I <br />�00C; <br />fnNO) U <br />c � <br />'j) <br />w O O U <br />4+-- <br />� ) <br />LL <br />., <br />�Qorn� <br />Z(1p 2 <br />� <br />cM <br />O <br />\1✓J <br />L-m <br />UC <br />1< <br />UUo <br />.. <br />a <br />o �- <br />000 • <br />ISSUED FOR REVIEW <br />DATE: <br />ISSUED FOR PERMIT <br />DATE: <br />ISSUED FOR CONSTRUCTION <br />DATE: <br />w <br />Q <br />0 <br />z <br />0 <br />0 <br />rA <br />W <br />ILL! <br />w <br />CHECKED BY: SABER <br />SHEET <br />m 1 <br />LRZ-1019-M01.dwg, Plotted By, Rick <br />Dec 29, 2010 - 441pm <br />