=- AmDTLAKrr U <br />r-.- ...-.. II <br />MECHANICAL 2 BEDROOM - <br />SCALE: <br />1 <br />(WITH LI <br />4"0 DRYER <br />MECHANICAL 1 BEDROOM RA <br />SCALE: 1 /4"=1'-0" <br />GENERAL NOTES: <br />1. UNLESS OTHERWISE MOTED, ALL DUCTWORK TO BE MOUNTED AS TIGHT TO FLOOR DECKING ABOVE <br />TO CREATE WORKABLE SPACE FOR ALL TRADES IN SOFFIT AREAS. <br />KEY NOTES: <br />QQ INSTALL 4"0 DRYER VENT WITH LINT TRAP MOUNTED IN WALL FOR CLEANING ACCESS. <br />COORDINATE FINAL DUCTWORK ROUTING AND LOCATION WITH ARCHITECTURAL CEILING AND <br />SOFFIT PLAN. <br />O2 INSTALL EXHAUST WALL CAP IN LOCATION AS SHOWN AND PAINT WALL CAP TO MATCH BUILDING <br />EXTERIOR COLOR. COORDINATE WITH ARCHITECT FOR FINAL COLOR SELECTION PRIOR TO <br />PAINTING. <br />O3 PROVIDE EXHAUST FAN PER EQUIPMENT SCHEDULE ON DRAWING M301 AND PER EQUIPMENT <br />DESIGNATION ON SHEETS M101 THROUGH M103. <br />® PROVIDE AIR HANDLING UNIT PER EQUIPMENT SCHEDULE ON DRAWING M301 AND PER <br />EQUIPMENT DESIGNATION ON SHEETS M101 THROUGH M103. <br />Q5 CONTRACTOR SHALL PROVIDE MOTORIZED DAMPER AND VOLUME DAMPER IN OUTSIDE AIR <br />DUCTWORK MOUNTED IN MECHANICAL CLOSET. CONTRACTOR SHALL BALANCE OUTSIDE AIR TO <br />CFM AS SHOWN IN THE AIR HANDLER SCHEDULE. <br />© COORDINATE WITH ARCHITECT TO PROVIDE FULLY LOUVERED DOORS FOR THE CLOSET TO <br />PROVIDE DIRECT RETURN AIRFLOW TO THE AIR HANDLER MOUNTED IN THE CLOSET. <br />O7 CONTRACTOR SHALL ROUTE REFRIGERANT PIPING DOWN FROM ROOF IN FIRE RATED CHASE AND <br />TIE INTO AIR HANDLER MOUNTED IN CLOSET. CONTRACTOR SHALL ALSO TIE 3/4" PVC <br />CONDENSATE DRAIN LINE INTO CONDENSATE RISER LOCATION IN THE FIRE RATED CHASE. <br />CONTRACTOR TO MAINTAIN MINIMUM 1/8" PER FOOT FOR SLOPE FOR ALL DRAIN LINES. <br />SYSTEM SUMMARY <br />HVAC DESIGN PARAMETERS <br />CITY <br />SUMMER DESIGN <br />OUTDOOR <br />SUMMER DESIGN <br />INDOOR <br />WINTER DESIGN <br />OUTDOOR <br />WINTER DESIGN <br />INDOOR <br />TAMPA, <br />FL <br />93.47/76.47 <br />75-F / 50%RH <br />29.6F <br />70'F <br />BUILDING <br />U-VALUE <br />GLASS <br />U-VALUE <br />SYSTEM <br />VENTILATION RATE <br />AS PER ASHRAE 62.1 <br />FILTRATION CRITERIA <br />ASHRAE 52.2 <br />ROOF = 0.1034 <br />WALL = 0.0626 <br />GLASS = 0.65 <br />SC = 0.25 <br />R A SUITE <br />5 CFM PERSON & 0.06 CFM SQ.Fr. <br />2"-MERV 11 <br />1-BEDROOM <br />5 CFM PERSON & 0.06 CFM SQ.FT. <br />2"-MERV 11 <br />2-BEDROOM <br />5 CFM PERSON & 0.06 CFM SQ.Fr. <br />2"-MERV 11 <br />2-BEDROOM ADA <br />5 CFM PERSON & 0.06 CFM SQ.Fr. <br />2"-MERV 11 <br />SYSTEM OCCUPANCY <br />DESIGN NOTES: <br />SYSTEM <br /># OF PEOPLE <br />OUTSIDE AIR <br />(CFM) <br />TYPE OF <br />OCCUPANCY <br />R/A SUITE <br />1 <br />20 <br />DWELLING UNIT <br />1-BEDROOM <br />3 <br />40 <br />DWELLING UNIT <br />2-BEDROOM <br />5 <br />60 <br />DWELLING UNIT <br />2-BEDROOM ADA <br />5 <br />60 <br />DWELLING UNIT <br />N <br />CEILING <br />12x100 <br />INTERIOR WALL <br />w <br />C-> <br />O <br />150.5 <br />' <br />IN E WALL <br />o <br />(BETWEEN STUDS) <br />w <br />C-> <br />Q <br />12000 <br />-FLOOR — <br />(APPLIES TO ALL APARTMENT BEDROOM TRANSFER GRILLES) <br />TRANSFER <br />DUCT <br />-EF-AP TMNT <br />3 <br />......... .................................... <br />1800.1 <br />.. ... 20� .205� <br />I 12x100 12 <br />x, 00 <br />00 <br />x <br />o <br />4"0 DRYER VENT) =-.... <br />(WITH LINT TRAP) <br />10 1 <br />; <br />12x100 `I 112x100 <br />A'9.12xloq) 12000x <br />T <br />3 <br />pL �� 063, 'o <br />12x8(D <br />Ij0 <br />CAP � \—WAL@LCAP WALLOI <br />ICAL) (TYPICAL) (iYPIC <br />MECHANICAL 2 BEDROOM ADA. <br />SCALE: 1 /4"44' <br />rr • - .. - II <br />MECHANICAL 1 BEDROOM- <br />SCALE: 1/4"=1'-O" <br />Furr, <br />Wegman & <br />Banks <br />Architects, P.A. AR0006480 <br />625 EAST ORANGE ST. <br />LAKELAND, FL 33801 <br />E-MAIL: INFO@FW BARCHITECTS.COM <br />W W W.FWBARCHITECTS.COM <br />PH. 863.688.1211 <br />® COPYRIGHT 2021 <br />FURR, WEGMAN & BANKS ARCHITECTS, PA <br />THE DESIGN AND CONCEPTS DEPICTED HEREWITH ARE THE SOLE <br />PROPERTY OF FURR, WEGMAN & BANKS ARCHITECTS, PA. <br />NO REPRODUCTION, REVISION OR REUSE OF THIS DRAWING IS <br />AUTHORIZED WITHOUT SPECIFIC WRITTEN PERMISSION. <br />ALL RIGHTS RESERVED. <br />\ \\1 11///// <br />B <br />o• R� E Rs' <br />�= <br />= * No. 36539 <br />STATE OF �\ <br />SCOFF/$pM; P.E. <br />FL. UC. 86532-28-2023 <br />U � <br />� <br />4; zr <br />�Iill = U <br />Tel 'a: W ' i <br />g <br />a C4 <br />4 GNP <br />6 <br />�ZOM�W <br />y �aZ <br />20 <br />MFIt <br />� � E <br />z <br />z <br />O <br />w <br />w <br />'V'J <br />^ <br />V! <br />F- <br />1 <br />z <br />O <br />a. <br />w <br />0 <br />U) <br />W <br />0 <br />z <br />O <br />0) <br />w <br />w <br />Q <br />0 <br />ar <br />CV <br />Ch <br />d <br />to <br />Cfl <br />ti <br />N <br />O <br />N <br />ti <br />N <br />Co <br />Cif <br />O <br />z <br />Q <br />Q <br />J <br />� <br />0- <br />/W <br />z <br />W <br />Z <br />F <br />W <br />z <br />j <br />2 <br />CD <br />O <br />F_ <br />z <br />0 <br />Q <br />Uo <br />o <br />�m <br />� <br />J <br />Q <br />zZ <br />U <br />(W <br />O <br />M <br />o <br />TH ZJ <br />O <br />O <br />2 <br />+ � <br />MI <br />U <br />mQ � >- <br />w <br />U) <br />W <br />°' °- <br />Q CoLLI CoN <br />_ <br />Q_ <br />PROJ MGR: <br />CKD BY: <br />MC/DB <br />SIN <br />JOB NUMBER: <br />21-19 <br />SHEET NUMBER: <br />M201 <br />Z:\Furr Wegman & Banks Architects\211036 - Healthier Stay Pasoo Dormhory\Design\211036 M201.dwg, August 27, 2021 4:06 PM, SHAWN JEFFREY, <br />