My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6444 Bar S Bar Trl
Zephyrhills
>
Building Department
>
Building Plans
>
6444 Bar S Bar Trl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 4:53:34 PM
Creation date
2/18/2025 3:36:22 PM
Metadata
Fields
Template:
Building Plans
Street #
6444
Location
Bar S Bar Trl
Contractor
Lennar Homes LLC
Building Plans - Permit #
4650
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELEC <br />METER <br />V <br />G <br />F <br />GFI <br />L— <br />PANTRY I I T GFI I GF <br />TO_ . <br />r `, DISP� <br />0 <br />:01,o <br />GFI AT <br />r 30" A.F.F. <br />4'-3" 5'-8" <br />KITCHEN <br />r• -_•_ .._...• . -, <br />GF1 co GF <br />A <br />GFI -10' <br />TILITIY <br />GFI AT <br />30" A.F.F. = <br />r 01 <br />GF <br />U/ <br />6'-0" <br />GFI <br />DINING <br />ROOM <br />O \ <br />-ELEC \ <br />PANEL <br />! TWO CAR GARAGE <br />48 <br />0 <br />GFI I `V <br />i <br />110V CLG <br />i <br />MNT. <br />_—_OUTLET --_ <br />i <br />I <br />I <br />I <br />I o <br />I <br />Q <br />Uj <br />i <br />i <br />i <br />F_ <br />---------------J <br />A/C <br />DISI <br />WP <br />GFI <br />HDMI <br />LIVING <br />i ROOM <br />u_ 2'-11 3/4" <br />C� <br />I <br />o <br />f <br />SS <br />PW_D_R\ <br />BATH J <br />TO 2N <br />LR ELE <br />o GFIffI <br />N WP <br />v� 4'-8" <br />- - - - - - - <br />ENTRY <br />FIRST FLOOR ELECTRICAL PLAN (ELEVATION A <br />1 /4" = 1'-0" <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST 3' FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN 44" AFF <br />BATHROOM 39" AFF <br />LAUNDRY ROOM 36" AFF <br />EXTERIOR WATERPROOF 12" AFF <br />GARAGE GENERAL PURPOSE 42" AFF <br />RANGE 2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />210 or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to Tooter steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />VIRTUAL REVIEW ASSIST 1St, Inc. \ <br />I e\J'e.``v s ed <br />th <br />th <br />��rni�ted and aPp <br />>:°I�r�;, V/00`h the 2020 PX2300 <br />'10 C10111.1 <br />d�.cjitiprr by Debra Are I�Ia�r <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />SWITCH — <br />DOORJAMB DUPLEX <br />OUTLET i7 <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oZ <br />S <br />SMOKE DETECTOR <br />1'-0" <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />SWITCH AT 36" <br />6 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />--0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" <br />PUSH-BUTTON DOORBELL <br />-rI} CLG MNT LT FIXTURE <br />{TB} CLG MNT PREWIRE - FIXTURE BY OWNER <br />{}- SURFACE MNT FIXTURE <br />-} WALL MNT FIXTURE <br />NOTE: <br />C ND OPALEX - ALTERNATE <br />TUB SHOWERCANS MAY BE <br />C 50W PAR30 NFL 6" WHITE BAFFLE USEDIF <br />APPROVED BY <br />C 50W MR16 4" LOW VOLTAGE OWNER <br />C 50W PAR20 NFL 4" MINI ROUND RECESS <br />�� 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-ir CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />CosCOMBINATION <br />DETECTOR <br />0S SMOKE DETECTOR <br />=U-18= UNDER CABINET 18" <br />=S-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />4= 48"CLG MNT WRAPPED FLUOR LIGHT <br />9F24:;;9 24" VANITY LIGHTING <br />F;—,36:FFR 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />ED CHIMES (DELETE W/ INTERCOM) <br />IMMF MASTER STATION <br />ELEC PANEL <br />VACUM OUTLET AT 12" <br />WA CEILING RETURN AIR <br />ED A/C REGISTER <br />OTJ THERMOSTAT <br />an SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />N <br />N LO E <br />�;M <br />W L o <br />N <br />Co N <br />z. D M M <br />W E L <br />� p u0 o <br />CD 0 <br />s U�10 <br />W <br />L 0O �r <br />co <br />W <br />'n <br />lyj '_1W O I- <br />F-~ C 0 ¢< z� <br />W Y Q z <br />�J r, <br />Z) <br />¢8X J W 0, (1) L'U�Q <br />0Www0_"0EEo_om0z <br />W(nww< <br />W J0 <br />U <br />O Z <br />fnW�W(nW W <br />< LU<-zWZO��p� <br />J <br />LL <br />OW �F- 2YOQQ <br />M OQQ� <br />Q <br />O� 0 <br />LL Q O F LL <br />O <br />O <br />N <br />Z LLJ <br />O I- <br />> (n O <br />0COMO <br />M � <br />�(1)LL-ti <br />< LU < Lo <br />i2 M <br />Q Q 00 <br />>- <br />Z U F- <br />z <br />w <br />W <br />O <br />O <br />O <br />I <br />9_ <br />M <br />O <br />N <br />o0000 <br />N <br />r` <br />p <br />N <br />N <br />O <br />N <br />N <br />�- <br />N <br />O <br />N <br />N <br />CD <br />o <br />O <br />� <br />O <br />� <br />CD <br />o <br />N <br />o <br />I <br />I <br />g <br />w <br />o <br />0 <br />0 <br />0 <br />0 <br />l <br />I <br />i <br />V <br />> <br />VJ <br />}~ <br />zz <br />W <br />Qw <br />O}, <br />}� <br />W <br />z <br />O <br />^ <br />�00 <br />U <br />i1 <br />O <br />zj <br />Or< <br />Z <br />d—d <br />Q <br />m w <br />N <br />zoo <br />LLI <br />. <br />O <br />�O <br />Q <br />z <br />gUjof <br />wLL <br />az <br />U, z <br />LL <br />Q <br />F <br />0U� <br />0 <br />W <br />z <br />z <br />z <br />w <br />LU <br />J <br />� <br />O <br />0 <br />LAST PLOT DATE <br />N <br />• <br />March 29, 2022 <br />Z <br />0 <br />1 ST FLOOR <br />ELECTRICAL PLAN A <br />
The URL can be used to link to this page
Your browser does not support the video tag.