ADA NOTES: <br />THE GENERAL CONTRACTOR SHALL ACQUAINT HIMSELF WITH THE BARRIER FREE REQUIREMENTS FOR THE <br />APPLICABLE STATES AND THE AMERICAN DISABILITIES ACT (ADA) AND SHALL INSURE THAT THIS FACILITY <br />WILL BE ACCESSIBLE ACCORDING TO THE STRICTER REQUIREMENTS OF THE APPLICABLE STANDARDS. THE <br />FOLLOWING IS A PARTIAL LIST OF REQUIREMENTS. <br />1. DOOR HARDWARE SHALL BE MOUNTED BETWEEN 36" AND 42" ABOVE FLOOR AND BE LEVER TYPE. <br />2. TOILETS: <br />A. LAVATORY TO HAVE LEVER HANDLES, SPRING FAUCETS OR SELF METERING FAUCETS. <br />B. A COAT HOOK 48" ABOVE THE FLOOR SHALL BE MOUNTED ON THE BACK SIDE OF THE BARRIER FREE <br />STALL DOOR. <br />C. LOCATE THE WATER CLOSET 18" FROM THE CENTER LINE OF THE FIXTURE TO THE WALL. THE SEAT <br />WILL BE 17" TO 19" ABOVE THE FLOOR TO THE TOP OF SEAT. FLUSH HANDLE TO BE ON <br />EXPOSED SIDE OF WATER CLOSET. <br />D. PROVIDE ONE 42" AND ONE 36" LONG x 1 1/2" OUTSIDE DIAMETER PEENED GRAB BARS, 1 112" <br />FROM THE WALL WITH ONE BEHIND AT 6" FROM THE WALL AND ONE ADJACENT TO AT 12" <br />FROM THE WALL 33-36" PARALLEL TO AND ABOVE THE FLOOR. <br />E. LAVATORY TO BE MOUNTED 34" MAX. ABOVE THE FINISHED FLOOR TO RIM WITH KNEE SPACE <br />OF 30" IN WIDTH AND 27" IN CLEAR HEIGHT. (29" CLEAR UNDER FRONT EDGE) <br />F. INSTALL MIRROR 40" MAX. ABOVE THE FINISHED FLOOR (TO BOTTOM) AND 72" TO TOP. <br />G. DISPENSERS TO BE MOUNTED A MAXIMUM OF 42" ABOVE THE FLOOR TO ALL OPERATING OR DISPENSING <br />SLOTS. <br />H. TOILET PAPER DISPENSERS MOUNTED 19" MIN. TO CENTER LINE ABOVE THE FLOOR. <br />STRUCTURAL NOTES <br />I- GOVERNING CODES: <br />THIS DESIGN IS BASED ON THE FOLLOWING CODES: <br />A- FLOR <br />IDA A BUILDING CODE 2004 WITH 2O06 AMENDMENTS. <br />B- BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE ACI 318 (2002 EDITION). <br />C- SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR <br />BUILDING, ASD DESIGN METHOD. <br />D- BUILDING CODE REQUIREMENTS FOR MANSONRY STRUCTURES, ACI 530-02/ASCE 5-02/ TMS <br />402-02. <br />E- STRUCTURAL WELDING CODE D1.1. <br />II- DESIGN LOADS: <br />A- WIND LOAD BASED ON USING THE ASCE 7-02 "MINIMUM DESIGN LOADS FOR BUILDING AND <br />OTHER STRUCTURES" METHODS OF CALCULATION FOR WIND PRESSURES AND THE FOLLOWING <br />FACTORS: <br />1- MEAN ROOF HEIGHT OF LESS THAN 30'-0". <br />2- WIND SPEED OF 110 MPH. <br />3- EXPOSURE CATEGORY "B". <br />4- IMPORTANCE FACTOR OF 1.0 (BUILDING CATEGORY II). <br />5- INTERNAL PRESSURE COEFFICIENT OF +/- 0.18 (ENCLOSED BUILDING). <br />6- THIS BUILDING IS IN A WIND BORNE DEBRIS REGION AS DEFINED BY FLORIDA <br />BUILDING CODE. ALL GLAZING IS ASSUMED TO BE PROTECTED IN ACCORDANCE <br />WITH SECTION 1609.1.4 OF FLORIDA BUILDING CODE. <br />B- ROOF LIVE LOAD OF 20 PSF WITH ALLOWABLE LOAD REDUCTIONS BASED ON AREA AS OUTLINED <br />IN THE FLORIDA BUILDING CODE. ROOF DRAINAGE SHALL CONFORM TO THE REQUIREMENTS OF <br />THE FLORIDA PLUMBING CODE SECTION 11.OVERFLOW DRAINS SHALL BE LOCATED SO THAT, IN <br />THE EVENT OF THE PRIMARY DRAINS BEING BLOCKED, NO MORE THAN 3Z OF WATER CAN <br />ACCUMULATE BEFORE ENTERING THE OVERFLOWS. <br />C- ROOF DEAD LOAD OF 20 PSF. <br />D- FRONT ENTRY ROOF DEAD LOAD OF 17 PSF TOTAL (7 PSF TOP CHORD,10 PSF CEILING). <br />E- ALLOWABLE SOIL BEARING OF 2,000 PSF. <br />III- SHOP DRAWINGS: <br />A- WHEN SHOP DRAWINGS ARE REQUIRED (3) COPIES MINIMUM SHALL BE SUBMITTED WITH (1) <br />COPY TO BE RETAINED BY THE REVIEWER. CONTRACTOR SHALL ALLOW FOR (10) TEN BUSINESS <br />DAYS FOR SHOP DRAWING REVIEW. <br />IV- DRAWINGS AND SPECIFICATIONS: <br />A- DO NOT SCALE THESE DRAWINGS FOR DIMENSIONS NOT GIVEN. ADVISE PROJECT ARCHITECT OS <br />ANY CONFLICTS BETWEEN THESE DRAWINGS AND THE ARCHITECTURAL DRAWINGS. VERIFY ALL <br />FIELD CONDITIONS AND CONFIRM COLUMN LOCATIONS IN RESPECT TO ARCHITECTURAL WALL <br />ALIGNMENT PRIOR TO THE START OF WORK. <br />B- THESE DRAWINGS ARE TO BE USED IN COMBINATION WITH THE ARCHITECTURAL, MECHANICAL, <br />PLUMBING AND CIVIL DRAWINGS. REFER TO THESE OTHER DRAWINGS FOR DETAILS THAT RELATE <br />TO STRUCTURAL COMPONENTS. <br />C- THESE CONSTRUCTION DOCUMENTS HAVE BEEN PREPARED FROM THE MOST COMPLETE <br />INFORMATION AVAILABLE TO THE ENGINEER. ALL DATA ON EXISTING CONSTRUCTION CONDITIONS <br />ARE APPROXIMATE AND SHALL BE VERIFIED PRIOR TO COMMENCING WORK. <br />D- THE CONTRACTOR SHALL COMPLY WITH THE MANUFACTURER'S INSTRUCTIONS AND <br />RECOMMENDATIONS TO THE EXTEND -PRINTED INFORMATION ARE MORE DETAILED OR STRIGENT <br />THAN THE REQUIREMENTS CONTAINED IN THE PLANS. <br />E- THE PLANS SHOW THE LOCATION OF ALL FIXTURES AND EQUIPMENT, AND ARE INTENDED TO <br />CONVEY THE GENERAL INTENT OF THE WORK IN SCOPE AND LAYOUT. THEY ARE NOT INTENDED TO <br />SHOW IN MINUTE DETAIL EVERY AND ALL OF THE ACCESSORIES INTENDED FOR THE PURPOSE OF <br />EXECUTION OF THE WORK, BUT IT IS UNDERSTOOD THAT SUCH DETAILS ARE PART OF THIS WORK. <br />F- THE CONTRACTOR SHALL PERFORM NO PORTION OF THE WORK AT ANY TIME WITHOUT CONTRACT <br />DOCUMENTS OR, WHERE REQUIRED, APPROVED SHOP DRAWINGS, PRODUCT DATA OR <br />SUPPLEMENTAL DETAILS FOR SUCH PORTION OF THE WORK. <br />G- THE CONTRACTOR IS RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION TO ENSURE <br />THE SAFETY OF THE BUILDING UNTIL THE STRUCTURAL SYSTEM IS COMPLETED. THE STRUCTURAL <br />SYSTEM IS UNSTABLE UNTILL ALL CONNECTIONS HAVE BEEN MADE AND ALL CONCRETE HAS <br />REACHED THE MINIMUM DESIGN STRENGTH AS SPECIFIED IN THESE DRAWINGS. <br />V- CONCRETE: <br />A- 3,000 PSI CONCRETE REQUIREMENT FOR FOUNDATIONS, BLOCK FILL, SLAB -ON -GRADE AND <br />SIDEWALKS. <br />B- MAXIMUM SLUMP: 4" (+/-1") FOR ALL CONCRETE, EXCEPT USE 8'-11" FILLING CELLS IN BLOCK. FLY <br />ASH, IF USED, SHALL NOT EXCEED 20% BY WEIGHT OT TOTAL CEMENTITIOUS CONTENT. SLUMP <br />LIMITS SHALL BE STRICTLY ADHERED TO. <br />C- THE CONCRETE SHALL CONTAIN THE MAXIMUM SIZE AGGREGATE PERMITTED BY ACI CODE UP TO <br />a MAXIMUM. THE GUIDELINES FOR MAXIMUM AGGREGATE SIZE ARE NOT GREATER THAN y THE <br />NARROWEST OPENING IN THE FORMS, AND/OR I THE DEPTH OF THE SLAB. <br />D- CONCRETE FORMWORK SHALL BE IN A CLEAN CONDITION FOR USE AS FINISHED SURFACE FORMS. <br />FORMS SHALL NOT BE REMOVED UNTIL THE CONCRETE IS OF SUFFICIENT STRENGTH TO SUPPORT <br />ITS OWN WEIGHT AND PROPOSED CONSTRUCTION LOADS. <br />E- MINIMUM CONCRETE COVER: <br />CONCRETE PERMANENTLY EXPOSED TO EARTH= 3 INCHES. <br />CONCRETE EXPOSED TO EARTH OR WEATHER=12 INCHES. <br />CONCRETE NOT EXPOSED TO EARTH OR WEATHER= 3/4 INCHES. <br />F- CONCRETE SHALL BE BATCHED, MIXED AND TRANSPORTED IN ACCORDANCE WITH THE <br />SPECIFICATIONS FOR READY -MIXED CONCRETE ASTM C94. CONCRETE SHALL BE PLACED WITH -IN <br />90 MINUTES OF BATCH TIME. <br />G- EXPANSION AND CONTRACTION JOINTS: FLOOR (CONTRACTION) JOINTS SHALL BE SAW CUT OR <br />PREFABRICATED AT A MAXIMUM SPACING OF 2 TO 3 TIMES THE SLAB THICKNESS IN FEET (i.e. 8'-12' <br />O/C FOR A 4" THICK SLAB). THESE CONTRACTION JOINTS SHALL BE APPROXIMATELY 8" WIDE AND <br />EXTEND TO A MINIMUM DEPTH OF i THE SLAB THICKNESS. A 4" PERIMETER EXPANSION (ISOLATION) <br />JOINT SHALL BE USED AT FLOORS ADJOINING WALLS AND AROUND ALL COLUMNS. THESE <br />ISOLATION JOINTS SHALL BE FORMED BY INSTALLING AN ASPHALT IMPREGNATED FIBER SHEET <br />THAT EXTENDS THE ENTIRE THICKNESS OF THE SLAB. <br />VI- CONCRETE REINNFORCEMENT: <br />A- REINFORCING STEEL BARS SHALL BE GRADE 60 (60 KSI ASTM A615) STEEL AND TIED WITH <br />DRAWN STEEL WIRE. <br />B- WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. <br />C- PLACEMENT OF REINFORCING STEEL SHALL BE AS SHOWN ON PLANS AND PER THE "MANUAL OF <br />STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES", ACI 315 MANUAL ON <br />PLACING STEEL REINFORCING. <br />D- PROVIDE MINIMUN LAP SPLICE OF 48 BAR DIAMETERS, BUT NOT LESS THAN 18 INCHES, FOR ALL <br />REINFORCING BARS, UNLESS NOTED OTHERWISE. STAGGER SPLICES IN ADJACENT BARS AT <br />LEAST 24 INCHES, EXCEPT IN BEAMS AND COLUMNS. <br />E- IN WALL FOOTINGS, GRADE BEAMS AND BOND BEAMS, PROVIDE BENT BARS AT CORNERS AND <br />INTERSECTIONS OF THE SAME NUMBER AND SIZE AS THE STRAIGHT BARS. <br />VII- CAST IN PLACE CONCRETE: <br />A- THE CONCRETE SUPPLIER SHALL PROVIDE MIX DESGNS OF ALL CONCRETE USED IN <br />STRUCTURAL APPLICATIONS. <br />B- WHEN POURING AGAINST EARTH, THE EMBANKMENT SHALL BE WETTED FIRST AND ALL POURS ON <br />DIRECT SUN DAYS WILL BE MISTED AT LEAST TWICE FOLLOWING INITIAL SET. ISOLATION JOINTS <br />SHALL BE PROVIDED AT ALL COLUMNS AND EXPANSION FELT AT THE PERIMETER OF THE SLAB. <br />C- FINISH ON THE SURFACE OF FLOOR SHALL BE MACHINED TROWELED FOLLOWED BY HAND FINISHING <br />AS REQUIRED. <br />D- EXTERIOR WALKS AND PARKING AREAS TO BE LIGHT BRUSHED FINISHED. <br />E- CURING OF CONCRETE SHALL BE IN ACCORDANCE WITH ACI 318. <br />VIII- FOUNDATIONS: <br />A- MAXIMUM SOIL BEARING PRESSURE USED FOR DESIGN ..... 2,000 PSF. <br />B- PREPARE SUBGRADE IN ACCORDANCE WITH GEOTECHNICAL REPORT, IF THERE IS ANY. <br />C- NOTIFY ENGINEER IF FOOTING EXCAVATION REVEALS UNSUITABLE OR UNSTABLE SOILS, OR <br />MATERIALS OR CONDITIONS NOT ANTICIPATED IN THE ORIGINAL REPORT. <br />D- CONCRETE PLACEMENT SHALL OCCUR IMMEDIATELY AFTER FOOTING EXCAVATION AND <br />PLACEMENT OF REINFORCING STEEL. ANY FREESTANDING WATER SHALL BE PUMPED OUT OF <br />FOOTING EXCAVATION PRIOR TO CONCRETE PLACEMENT. <br />E- A QUALIFIED TESTING LABORATORY SHALL BE RETAINED TO PERFORM THE FOLLOWING MINIMUM <br />IN -PLACE DENSITY TESTS: THIS SUGGESTED TESTING SHALL BE USED IN ABSENCE OF TESTING <br />PROGRAM SUGGESTED BY A SOIL ENGINEER AS CONTAINED IN A SOIL REPORT PERFORMED FOR <br />THIS PROJECT. <br />1- ONE DENSITY TEST FOR EACH 2,500 SQUARE FEET OF COMPACTED SUBGRADE. <br />2- ONE DENSITY TEST AT EACH COLUMN. <br />3- ONE DENSITY TEST PER 50 FEET OF WALL FOOTING. <br />IX- STEEL BAR JOIST: <br />A- THE DESIGN, FABRICATION AND ERECTION OF STEEL JOIST SHALL CONFORM TO THE <br />"AMERICAN INSTITUTE OF STEEL CONSTRUCTION STANDARD SPECIFICATION FOR OPEN <br />WEB STEEL JOIST" (LATEST EDITION). <br />B- JOISTS SUPPLIED UNDER THIS SECTION SHALL BE FABRICATED BY A RECOGNIZED MANUFACTURER, <br />USING CORD OR WEB SECTIONS FABRICATED FROM STEEL HAVING A YIELD STRENGTH OF AT LEAST <br />36 KSI BUT NOT EXCEEDING 50 KSI. <br />C- BRIDGING PER THE APPLICABLE STEEL JOIST INSTITUTE SPECIFICATION 9LATEST EDITION) SHALL BE <br />USED AND SHALL BE INSTALLED BEFORE CONSTRUCTION LOADS ARE APPLIED TO THE JOISTS. THE <br />ENDS OF ALL BRIDGING LINES TERMINATING AT WALLS OR BEAMS SHALL NOT BE ANCHORED UNTILL <br />ALL THE ROOF DEAD LOADS ARE APPLIED. <br />D- ENDS OF JOISTS RESTING ON STEEL SUPPORTS SHALL BE CONNECTED WITH THE EQUIVALENT <br />OF TWO 1/8- INCH FILLET WELDS 1 INCH LONG OR WITH i INCH DIAMETER BOLTS. FIELD WELDING <br />SHALL NOT DAMAGE THE JOISTS. <br />E- ALL JOISTS ON COLUMN CENTERLINES SHALL BE SECURED BY 1 INCH DIAMETER A325 BOLTS AT THE <br />TOP CHORD BEARING. THE BOTTOM CHORD SHALL BE EXTENDED TO THE COLUMN. <br />F- JOISTS SHALL BEAR 4" MINIMUM ON MANSONRY AND 22'" MINIMUM ON STEEL U.N.O. JOISTS BEARING <br />ON MASONRY SHALL BEAR ON AN ENBEDDED STEEL PLATE. <br />G- STEEL JOISTS SHALL BE PRIMED PAINTED WITH ONE COAT OF LIGHT GRAY PRIMER MEETING THE <br />MINIMUM REQUIREMENTS OF FEDERAL SPECIFICATION TT-P-636 OR STEEL STRUCTURES PAINTING <br />COUNCIL SPECIFICATION 15-68T, TYPE I. <br />H- JOISTS GIRDERS SHALL BE PROPORTIONED SUCH THAT THEY CAN BE ERECTED WITHOUT BRIDGING. <br />THE STRUTTED ENDS OF THE BOTTOM CORD SHALL BE RESTRAINED FROM LATERAL MOVEMENT TO <br />BRACE THE GIRDER FROM OVERTURNING. <br />I- BAR JOISTS AND TRUSS GIRDERS SHALL HAVE MANUFACTURER'S STANDARD BEVELED ENDS OR <br />SLOPED SHOES, IF SLOPE EXCEEDS' INCH PER 12 INCHES. <br />J- STEEL JOISTS SHALL BE DESIGNED TO RESIST NET UPLIFT AS SHOWN ON WIND DIAGRAM SHOWN IN <br />CONTRACT DRAWINGS. <br />X- STRUCTURAL STEEL: <br />A- FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH AISC <br />"SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL <br />FOR BUILDINGS" (LATEST EDITION). <br />B- STRUCTURAL STEEL SHAPES (USED AS BEAMS AND COLUMNS) SHALL CONFORM TO ASTM A572 <br />GRADE 50 KSI UNLESS OTHERWISE NOTED ON THE CONTRACT DRAWINGS. <br />C- PLATES, CHANNELS, RODS, ANCHOR BOLTS AND ANGLES SHALL CONFORM TO ASTM A36 UNLESS <br />OTHERWISE NOTED OF THE CONTRACT DRWINGS. <br />D- STEEL PIPE SHALL CONFORM TO ASTM A53 GRADE B OR ASTM A501. <br />E- STRUCTURAL TUBING SHALL CONFORM TO ASTM A500 GRADE B (46 KSI MINIMUM). <br />F- ALL BOLTS (EXCEPT ANCHOR BOLTS) SHALL BE HIGH STRENGTH (HSB) SHALL CONFORM TO ASTM <br />A325, �" DIAMETER UNLESS NOTED OTHERWISE. HIGH STRENGTH BOLTS SHALL BE USED UNLESS <br />SPECIFICALLY NOTED ON THE DRAWINGS. <br />G- ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS IN ACCORDANCE WITH AWS "CODE FOR <br />ARC AND GAS WELDING IN BUILDING CONSTRUCTION" (LATEST EDITION). THE MINIMUM ELECTRODE <br />USED SHALL BE E70xx LOW HYDROGEN ELECTRODES UNLESS OTHERWISE SPECIFIED. <br />H- STRUCTURAL STEEL SHALL BE PRIMED PAINTED WITH ONE COAT OF LIGHT GRAY PRIMER MEETING <br />THE MINIMUM REQUIREMENTS OF FEDERAL SPECIFICATION TT-P-636 OR STEEL STRUCTURES <br />PAINTING COUNCIL SPECIFICATION 15-68T, TYPE I. <br />I- ALL BEAMS SHALL BE FABRICATED AND ERECTED NATURAL CAMBER UP. <br />J- CONNECTIONS MAY BE SINGLE SHEAR PLATE (OR DOUBLE ANGLE) FRAMED BEAM <br />CONNECTIONS PER AISC UNLESS NOTED OTHERWISE. ALL BOLTS SHALL BE a" DIAMETER A-325-N <br />UNLESS NOTED OTHERWISE. SHOP CONNECTIONS MAY BE BOLTED OR WELDED, WITH WELDED <br />CONNECTIONS EQUAL TO BOLTED CONNECTIONS. ALL BOLTS SHALL BE TIGHTENED SNUG TIGHT WITH <br />SUITABLE NUTS AND HARDENED WASHERS UNLESS NOTED OTHERWISE. DESIGN CONNECTIONS FOR <br />THE LARGER OF EITHER THE SHEARVALUE SHOWN ON THE DRAWINGS OR 75% OF THE MAXIMUM <br />SHEAR LISTED IN THE TABLES FOR "ALLOWABLE UNIFORM LOAD IN KIPS FOR BEAMS LATERALLY <br />SUPPORTED" AT THE BOTTOM OF EACH PAGE IN THE "PRPPERTIES AND REACTION VALUES" PART 2 OF <br />THE LATEST EDITION OF THE AISC "MANUAL OF STEEL CONSTRUCTION". <br />K- SPLICING OF STRUCTURAL STEEL WHERE NOT DETAILED IS NOT PERMITTED WITH OUT PRIOR WRITTEN <br />APPROVAL OF THE STRUCTURAL ENGINEER. <br />L- STRUCTURAL OPENINGS, SUPPORTS, ANCHORS, ETC. AROUND OR AFFECTED BY MECHANICAL, <br />ELECTRICAL AND PLUMBING EQUIPMENT SHALL BE VERIFIED WITH THE EQUIPMENT PURCHASED <br />BEFORE PROCEEDING WITH STRUCTURAL WORK AFFECTED. <br />XI- METAL ROOF DECK: <br />A- METAL ROOF DECK SHALL BE 1l" THICK, 22 Ga. TYPE B (AS IDENTIFIED BY THE STEEL DECK INSTITUTE) <br />PAINTED GRAY STEEL DECK CONFORMING TO ASTM A611 OR ASTM A653. <br />B- THE DECK SHALL BE PLACED ON THE SUPPORTING FRAMEWORK WITH A MINIMUM END LAP OF TWO <br />INCHES CENTERED OVER SUPPORTS. THE DECK SHALL BE ATTACHED TO THE SUPPORTS AND THE <br />SIDE LAP OF ADJACENT UNITS IN THE PATTERN SHOWN ON THE CONTRACT DRAWINGS. <br />C- ALL ROOF DECK OPENINGS 12" DIAMETER OR LARGER ARE TO HAVE SUPPORT ANGLES PER TYPICAL <br />DECK OPENING DETAIL, INCLUDING OPENINGS DETAIL, INCLUDING OPENINGS FOR ROOF SUMP PANS. <br />D- ROOF DECK SHALL BE LAID OUT SUCH THAT DECKING SHALL SPAN THREE SPANS WITHOUT <br />INTERRUPTION WHEREVER POSSIBLE. <br />E- DECK AND SUPPORTING MEMBERS DAMAGED BY EXCESS WELDING HEAT SHALL BE REPAIRED OR <br />REPLACED AS DETERMINED BY ENGINEER. <br />F- PUDDLE WELDS SHALL BE AT LEAST s IN EFFECTIVE DIAMETER OR AN ENLOGATED WELD HAVING AN <br />EQUAL PERIMETER. FILLET AND SEAM WELDS WHEN USED SHALL BE A MINIMUM OF 12" LONG. WELD <br />METAL SHALL PENETRATE ALL LAYERS OF DECK MATERIAL AT END LAPS AND SIDE JOINTS AND HAVE <br />GOOD FUSION TO THE SUPPORTING MEMBERS. <br />XII- CONCRETE MASONRY: <br />A- A CONCRETE BLOCK WORK UNDER THIS SECTION SHALL BE AS PER PLANS AND SHALL BE PLUMB, <br />TRUE TO LINE WITH LEVEL COURSES ACCURATELY PLACED. WHERE NO PATTERN IS INDICATED, <br />MASONRY SHALL BE LAID IN A RUNNING BOND. <br />B- ALL CONCRETE BLOCKS SHALL HAVE A MINIMUM fm OF 2,000 PSI AND BE OF STANDARD WEIGHT <br />CONFORMING TO ASTM C-90 TYPE N-1. CONCRETE MASONRY UNITS SHALL BE DRY WHEN LAID. <br />C- MORTAR SHALL BE USED WITHIN 221 HOURS AFTER INITIAL MIXING. MORTAR THAT HAS STIFFENED DUE <br />TO EVAPORATION WITHIN THIS PERIOD SHALL NOT BE RETEMPERED OR RESTORED TO WORKABILITY. <br />MORTAR SHALL BE TYPE S (fm=3,000 PSI AT 28 DAYS) FOR ABOVE GRADE WORK, AND <br />TYPE M (fm=4,000 PSI AT 28 DAYS) FOR BELOW GRADE AND RETAINIG WALLS. <br />D- HOLLOW UNITS SHALL BE LAID WITH FULL MORTAR COVERAGE OF HORIZONTAL AND VERTICAL FACE <br />SHELLS. WEBS SHALL ALSO BE BEDDED IN ALL COURSES OF PIERS, COLUMNS, PILASTERS AND IN THE <br />STARTING COURSES ON FOOTINGS, AND WHERE ADJACENT TO CELLS OR CAVITIES TO BE FILLED WITH <br />COARSE GROUT. MORTAR JOINTS SHALL BE a THICK EXCEPT WHERE OTHERWISE INDICATED. <br />EXTERIOR WALLS TO BE COVERED SHALL HAVE FLUSH JOINTS AND INTERIOR WALLS SHALL BE <br />TOOLED WITH A ROUND JOINTER. <br />E- HORIZONTAL JOINT REINFORCING (WIRE TYPE WITH 9 GAGE EQUAL TO DUR-O-WAL) SHALL BE AT 16" <br />O.C. VERTICALLY AND SHALL EXTEND AT LEAST 6" INTO VERTICAL COLUMNS OR PILASTERS. <br />HORIZONTAL REINFORCEMENT SHALL NOT BE CONTINUOUS ACROSS CONTROL JOINTS AND SHALL BE <br />PLACED FULLY EMBEDDED IN FACE -SHELL MORTAR BEDS FOR THEIR ENTIRE LENGTH (MINIMUM <br />MORTAR COVER OF a ). <br />F- VERTICAL REINFORCEMENT (WHERE REQUIRED) SHALL BE PLACED IN THE CENTER OF MASONRY <br />CORES UNLESS SHOWN OTHERWISE. THIS REINFORCEMENT SHALL BE LAPPED (WHERE REQUIRED) A <br />MINIMUM OF 48 BAR DIAMETER OR 2'-l" WHICHEVER IS GREATER. MANSORY CORES SHALL BE FILLED <br />WITH COARSE GROUT CONFORMING TO ASTM C476. <br />1- 3,000 PSI AT 28 DAYS. <br />2- 8" AGGREGATE. <br />3- 8" -11" SLUMP. <br />G- BOND BEAMS SHALL CONSIST OF LOAD -BEARING UNITS FILLED WITH COARSE GROUT AND <br />REINFORCED AS INDICATED UNLESS NOTED OTHERWISE IN CONTACT DRAWINGS. REINFORCEMENT <br />SHALL BE CONTINUOUS EXCEPT THROUGH EXPANSION (CONTOL) JOINTS. WHERE BOND BEAM IS NOT <br />BROKEN AT CONTROL JOINT, A DUMMY CONTROL JOINT SHALL BE FORMED IN THE BOND BEAM. <br />H- UNFINISHED WORK SHALL BE STEPPED BACK FOR TOOLING WITH NEW WORK. TOOTHING MAY BE <br />EMPLOYED ONLY WHEN SPECIFICALLY APPROVED. BEFORE LAYING NEW WORK, LOOSE MORTAR <br />SHALL BE REMOVED AND THE EXPOSED JOINT THOROUGLY CLEANED. <br />I- USE MASONRY SAWS TO CUT BLOCK AS REQUIRED. <br />J- IF WALL REINFORCING IS NOT SHOWN PLANS, PLACE ONE #5 REBAR IN A CELL FILLED WITH COARSE <br />GROUT AT A MAXIMUM SPACING OF 48". ALSO FILL THE FIRST CELL ADJACENT TO ANY OPENING AND <br />LOCATED THREE FILLED CELLS AT ANY WALL CORNER OR INTERSECTION. <br />K- PROVIDE CLEAN -OUTS FOR FILLED CELLS IN LIFTS EXCEEDING 4 FEET, BUT LIFT SHALL NOT EXCEED <br />12'-0". <br />L- AT THE COMPLETION OF THE WORK ALL HOLES IN JOINTS OF MASONRY SURFACES TO BE EXPOSED OR <br />PAINTED (EXCEPT WEEP HOLES) SHALL BE FILLED WITH MORTAR AND SUITABLY TOOLED. MASONRY <br />WALLS SHALL BE DRY BRUSHED AT THE END OF EACH DAYS WORK AND ALSO AFTER FINAL POINTING <br />AND SHALL BE LEFT CLEAN AND FREE MORTAR SPOTS AND DROPPINGS. ANY CRACKS IN MASONRY <br />SHALL BE REPAIRED. DEFECTIVE JOINTS SHALL BE CUT OUT AND REPOINTED. <br />M- SPACE MASONRY CONTROL JOINTS AT A MAXIMUM OF 25'0" O.C. (U.N.0). <br />N- ALL MASONRY THAT IS RETAINING EARTH, AS IN A RETAINING WALL OR STEM WALL SHALL BE FILLED <br />SOLID FOR PORTION IN CONTACT WITH EARTH. <br />IT <br />U 0 <br />J CV N N <br />wM (��N <br />0- Z L0 Z Q m <br />mwco M <br />OQM W-wWJ <br />D <br />���'I� 0 0 o o <br />V�� �JJ <br />1.Q° CnQ�. <br />ZwU_ �� J <br />QM ZL_ <br />O�Q Qcco s'_ <br />~ CL <br />co C) wLu N <br />O <br />� <br />w <br />V <br />g <br />r^., <br />in <br />cy <br />c <br />3-.'4 <br />to <br />v/ <br />A l <br />p cq _U <br />m chi c$ Z <br />MILL <br />� <br />N m <br />J <br />.V <br />J <br />LL <br />J <br />Qa� <br />(D M M <br />o <br />cco c <br />V` <br />(D0 <br />C/WA/ <br />0 <br />' / <br />W <br />a <br />N <br />L~ <br />o <br />it <br />Z <br />Z <br />z <br />O <br />w <br />co <br />0 <br />w <br />o <br />g <br />r` <br />o <br />r <br />H <br />Z <br />N <br />c <br />d <br />C7 <br />LL <br />Q <br />o <br />tii <br />a' <br />w <br />tit <br />U <br />a <br />w <br />Y <br />LLI <br />cr_ <br />a <br />p <br />s <br />a <br />w <br />x <br />cn <br />o <br />1= <br />o <br />0 <br />°d <br />0 <br />U) <br />Z <br />O <br />Z <br />O <br />a <br />U <br />w <br />0 <br />w <br />to <br />U) <br />-t <br />cM <br />N <br />0 <br />