My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6636 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6636 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 11:47:53 AM
Creation date
2/18/2025 3:43:40 PM
Metadata
Fields
Template:
Building Plans
Street #
6636
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4' OFF <br />SHINGLE ROOF RIDGE VENT <br />6 12 12 6 SHINGLE ROOF <br />A5 5 A5 <br />6 _..f 1 1 7�� <br />A5 12 <br />5 12 <br />11-0.1 _ ELEV AT 18'-0" 5 <br />SECOND FLOOR CEILING ELEV AT 18'-0" <br />O.H. SECOND FLOOR CEILING <br />O.H. ` z � A5 <br />w _ 7/8 STUCCO z = <br />7 - 7 OVER PLYWOOD w <br />N J In - = <br />7/8 STUCCO �? rt A5 CASING BEAD 7/8" STUCCO J <br />OVER FRAME-----,'� `V IOVER FRAME N J <br />W/ WEEPS OVER <br />10 _ <br />12 FLASHING C.J.1 C.J. 1CA C.J.1 C.J. <br />ELEV AT 10'-0" ,_ „ 3,_0" <br />A5 WEEP SECOND FLOOR FF 6 4 — — 10 -0 _ _ — 10 8 — — 10 0 6 4 —ELEV AT - <br />- 12 SECOND F OOR FF <br />12" PAINTED RAISED SCREED ...�-- <br />♦ ELEV AT 8-8 w DRIP "V <br />STUCCO BAND I FIRST FLOOR CEILING SCREED-7ELEV AT 8'-8" <br />DRIP "V" SCREED ❑ ❑� ❑ ♦ V I� WEEP %-5/8" STUCCO FIRST FLOOR CEILING <br />5/8 STUCCO El <br />1:11:1 <br />1 ❑ ❑ E <br />T PAINTED RAISED SCREED OVER CMU <br />OVER CMU <br />r <br />IT TRIM BAND <br />PAINTED METAL1:1 EED� I 1100 <br />PAINTED <br />AND RAISED <br />�❑GARAGE DOOR ° <br />_ _ Q <br />_ I _ _ ELEV AT U-0" AIIIIIII <br />11 FIRST FLOOR FF <br />_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ELEV AT 0'-0" <br />13 FIRST FLOOR FF <br />A5 <br />FRONT ELEVATION A <br />3/ 16" = 1 '-0" <br />RIDGE VENT <br />SHINGLE ■�11 <br />_..�11�1�11►1111 <br />z� I <br />�= I <br />N J <br />r L <br />C.J.1 SS <br />WEEP <br />SCREED <br />o _ <br />® 00 80 00 <br />co io <br />REAR ELEVATION A <br />3/ 16" = 1 '-0" <br />I <br />I <br />7/8" STUCCO <br />OVERFRAME <br />v C.J1 <br />CASING BEAD <br />W/ WEEPS <br />OVER <br />FLASHING <br />%-5/8" STUCCO <br />OVER CMU <br />ELEV AT 18'-0" <br />SECOND FLOOR CEILING <br />ELEV AT 1 V-0" <br />_ SECOND FLOOR FF <br />ELEV AT 8'-8" <br />FIRST FLOOR AT <br />_ ELEV AT 0'-0" <br />FIRST FLOOR FF <br />RIGHT ELEVATION A <br />3/16" = 1'-0" <br />SHINGLE ROOF <br />12 <br />5 ..•d <br />12 C.J1 <br />4 3'-4" <br />RIDGE VENT <br />I I I I <br />I I I I <br />7/8" STUCCO <br />OVER FRAME <br />C.J.1 C.J. I C.J.1 C.J.1 <br />8�-8" — — —8 -8 — — 8 -8 — — — 8'-8" —L 3-4" <br />%-5/8" STUCCO WEEP <br />OVER CMU SCREED <br />"-CASING BEAD io <br />W/ WEEPS <br />OVER <br />FLASHING <br />LEFT ELEVATION A <br />3/16" = 1'-0" <br />ELEV AT 18'-0" <br />SECOND FLOOR CEILING <br />12 <br />ELEV AT 10'4" <br />4 <br />SECOND FLOOR FF <br />_\ <br />ELEV AT 8'-8" <br />t'-0" <br />FIRST FLOOR CEILING <br />ELEV AT 0'-0" <br />FIRST FLOOR FF <br />FLASHING NOTES: <br />DUE TO CLARITY NOT ALL REQUIRED FLASHING ARE <br />INDICATED ON DRAWINGS. REFER TO FBC RES 2020 (7TH <br />EDITION), SECTION R703.4. AND R903.2 APPROVED <br />CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED AT <br />ALL ROOFING SYSTEM INTERRUPTIONS, TERMINATIONS, <br />INTERSECTIONS, AND PENETRATIONS AND IN THE <br />EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO <br />PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR <br />PENETRATION OF WATER TO THE BUILDING STRUCTURAL <br />FRAMING COMPONENTS. THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH AND <br />SHALL BE INSTALLED TO PREVENT WATER FROM <br />REENTERING THE EXTERIOR WALL ENVELOPE. APPROVED <br />CORROSION -RESISTANT FLASHING SHALL BE INSTALLED <br />AT ALL OF THE FOLLOWING LOCATIONS: <br />1. AT TOP OF ALL EXTERIOR WINDOW AND DOOR <br />OPENINGS IN SUCH A MANNER AS TO BE LEAK PROOF, <br />EXCEPT THAT SELF -FLASHING WINDOWS HAVING A <br />CONTINUOUS LAP OF NOT LESS THAN 1-1/8 INCHES (28 <br />MM) OVER THE SHEATHING MATERIAL AROUND THE <br />PERIMETER OF THE OPENING, INCLUDING CORNERS, DO <br />NOT REQUIRE ADDITIONAL FLASHING; JAMB FLASHING <br />MAY ALSO BE OMITTED WHEN SPECIFICALLY APPROVED <br />BY THE BUILDING OFFICIAL. <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER <br />MASONRY CONSTRUCTION WITH FRAME OR STUCCO <br />WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER <br />STUCCO COPINGS. <br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR <br />METAL COPINGS AND SILLS. <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD <br />TRIM. <br />5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS <br />ATTACH TO A WALL OR FLOOR ASSEMBLY OF <br />WOOD -FRAME CONSTRUCTION. <br />6. AT WALL AND ROOF INTERSECTIONS. <br />7. AT BUILT-IN GUTTERS. <br />8. WHENEVER THERE IS A CHANGE IN ROOF SLOPE OR <br />DIRECTION. <br />9. AT ROOF CRICKET OR SADDLE. <br />10. AROUND ROOF OPENINGS. <br />GENERAL FLASHING NOTES: <br />INSTALL FLASHING IN ACCORDANCE WITH FBC RES 7TH <br />EDITION (2020), SECTION R703.4 AND IN ACCORDANCE <br />WITH STANDARD APPLICATIONS ILLUSTRATED IN THE <br />ARCHITECTURAL SHEET METAL MANUAL (LATEST <br />EDITION) AS PUBLISHED BY THE SHEET METAL AND AIR <br />CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION, <br />INC. <br />WINDOW NOTE: <br />ALL NEW WINDOWS MUST MEET A MINIMUM 'U'-VALUE OF <br />0.4 OR LESS AND A'SHGC' OF 0.25 OR LESS. (UTILIZING <br />THE PRESCRIPTIVE METHOD FOR EXISTING STRUCTURES) <br />* EGRESS NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT <br />COMPLIES WITH EGRESS CODES, IF THERE IS NO ACCESS <br />TO EXTERIOR THROUGH A DOOR. THE WINDOW MUST <br />HAVE A MAXIMUM SILL HEIGHT OF 44" ABOVE FINISH <br />FLOOR LINE OF THAT PARTICULAR ROOM <br />SHINGLE / UNDERLAYMENT NOTE: <br />ASPHALT SHINGLES ARE IN ACCORDANCE WITH TABLE <br />R905.2.6.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />SHINGLE UNDERLAYMENT SHALL COMPLY WITH SECTION <br />905.1.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />GENERAL FINISH NOTES: <br />APPLICATION OF STUCCO (EXTERIOR PLASTER) <br />MUST BE IN ACCORDANCE WITH FBC R703.7, <br />ASTM C926 AND C1063 <br />ALL LATH AND LATH ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL. (REFER TO SHEET SN1 <br />FOR THE ENGINEERED METHOD FOR LATH ATTACHMENT) <br />I'll <br />for cur <br />M <br />O <br />N <br />LO <br />co <br />' 5..i I �:. W <br />0 <br />w <br />,,Y <br />Q <br />LO E <br />> 0 o <br />M c d <br />�� to c9 <br />CQ <br />N V a0 auiP <br />Al L p <br />u <br />_ QbG <br />O LLg Q <br />'O <br />. N i w t3 <br />QN C <br />V1 <br />-TWA fL� Q E <br />v V 0 a '000 <br />LU <br />w <br />O~WJ W2 <br />w�U_Z� <br />LU 0 <br /><Uamg-joWW00-p0 <br />Q <br />OOZM0H <br />LiJ¢O0Q <br />�JZ_j<LUzw <br />H~ <br />OU)W <br />aFnWO <br />WW Z WW V5 W <br />0 n<�ZO <br />LL <br />OOX MHOLL �YZQQ <br />¢¢� <br />1 <br />O <br />Z N <br />OW <br />L f` <br />6 <br />t� F- c <br />QU)Mr" <br />z <br />F-111ZM <br />W CL 2 1- <br />< >_00 <br />Z V F- <br />W <br />W <br />Jmi <br />I- <br />UL <br />21223 <br />I <br />I <br />In <br />. <br />dap <br />.' <br />rov <br />d <br />l817th <br />by Debra Anne Kl <br />hr F <br />X0 <br />i <br />I <br />ON <br />Q <br />N <br />N <br />N <br />N <br />N <br />CQQQ <br />N <br />N <br />f+ <br />r <br />-W <br />N <br />z <br />o <br />000 <br />0 <br />N LO <br />`) <br />W <br />o <br />0 <br />0 <br />0 <br />0 <br />0; <br />C <br />Z ~ <br />Qz <br />o <br />W <br />w <br />Woo <br />V <br />VU� <br />L .� <br />F— <br />O <br />OWE <br />0E-4 <br />Q <br />Z <br />a m <br />F- <br />WT4 <br />2:im <br />L" W <br />o <br />(V <br />V <br />F- <br />NIX <br />�O� <br />W <br />�:3 <br />0 <br />O <br />ZWO <br />NQ <br />Z <br />U <br />gwU_ <br />azw <br />Z <br />52z <br />F� <br />OU <br />t1 <br />_p <br />W <br />z <br />z <br />w <br />W <br />LoJ <br />0 <br />0 <br />LAST PLOT DATE <br />• <br />z �' <br />May 8, 2023 <br />J <br />EXTERIOR <br />ELEVATIONS A <br />
The URL can be used to link to this page
Your browser does not support the video tag.