ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST X FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GAP,AGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />SECOND FLOOR ELECTRICAL PLAN (ELEVATION A&B <br />1 /4" = 1'-011 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />SWITCH <br />° <br />4 1/2" <br />DOORJAMB <br />DUPLEX <br />OUTLET c� <br />TRIM <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />p Z <br />S <br />SMOKE DETECTOR <br />1'-0" <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" <br />NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" <br />ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" <br />SHALL BE <br />SPLIT 110V DUPLEX OUTLET <br />MOUNTED <br />HORIZONTAL <br />AT 12" - TOP PLUG IS HOT <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />© STRUCTURED WIRE OUTLET <br />SWITCH AT 36" <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" <br />-� PUSH-BUTTON DOORBELL <br />-�- CLG MNT LT FIXTURE <br />+ CLG MNT PREWIRE - FIXTURE BY OWNER <br />+ SURFACE MNT FIXTURE <br />-}- WALL MNT FIXTURE <br />NOTE: <br />- 40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />04 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />�6 50W MR16 4" LOW VOLTAGE OWNER <br />08 50W PAR20 NFL 4" MINI ROUND RECESS <br />00 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-0 CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />C SMOKE DETECTOR <br />cU-18m UNDER CABINET 18" <br />-S-18m SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />— U-36 = UNDER CABINET 36" <br />S-36 — SINGLE 36" FLUOR STRIP <br />— D-36 — DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />® 48"CLG MNT WRAPPED FLUOR LIGHT <br />FF24:;;g 24" VANITY LIGHTING <br />F;—,36:7mR 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />p� DOUBLE FLOOD LIGHT W/ COVERS AND <br />V 150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />IMK( MASTER STATION <br />ELEC PANEL <br />VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />EM A/C REGISTER <br />CT THERMOSTAT <br />OB SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />i <br />cA 4) Iv L ^ E <br />^` > o o <br />I.'C �O <br />W U <br />3Mo. o�� a; <br />N Cn <br />V � 0- co, <br />4)." r <br />u 0 $ <br />`o <br />p 8 <br />�_ U <br />N <br />�w Q O- <br />^, N � <br />W L cO Ec <br />0 CO m <br />a <br />w <br />W Q W J W O <br />U <br />i- F_ <br />QdX- W LL.o �000�0 <br />O <br />CQ1wxg0_ZOwO COWL) <br />O O <br />U) O Z <br />Vr 0 �fA W F fn W x <br />oxJ <br />CL <br />QOwO� PZ2w� <br />OQ o � U_ <br />o¢ <br />Qom¢ <br />�� <br />O <br />O <br />ZW <br />F- <br />(j) 0 <br />O <br />0 � M <br />Q � CO � <br />U)LL <br />ti <br />F— W _M <br />00 <br />ZUF- <br />WZ� <br />J <br />AIL <br />?0 <br />3 <br />Virtual Re <br />Plans Review co <br />ew <br />ple <br />Assi, <br />e <br />t. Inc. <br />compliance with <br />he <br />a <br />00 <br />d a <br />P a <br />ed <br />Laebra An <br />a Kl <br />hr lIX23 <br />10 <br />O <br />0 <br />c,4 <br />0 <br />0 <br />0 <br />N <br />1- <br />o <br />N <br />N <br />a <br />O <br />� <br />IV <br />OO <br />00 <br />(y <br />� <br />O <br />O <br />N <br />r' <br />O <br />N <br />N <br />N <br />Z <br />o <br />� <br />.- <br />o <br />0 <br />0 <br />O <br />NL0 <br />w <br />p <br />o <br />0 <br />0 <br />0 <br />0 <br />l <br />i <br />> <br />� <br />CV <br />M <br />46 <br />6 <br />� <br />' Cr <br />W U) <br />Z H <br />_ <br />O Q <br />W <br />Qz <br />W <br />Woo <br />U <br />UVV5 <br />F. <br />O <br />mz> <br />OO�o <br />Z <br />~ (L <br />F- <br />w Q <br />N <br />w <br />I- <br />N <br />� <br />�O� <br />(� <br />W <br />>. <br />0 <br />zwo <br />>_ CV <br />Z <br />U <br />• <br />Z <br />azLL <br />� <br />US <br />p <br />_o <br />W <br />z <br />Z <br />w <br />LUu-) <br />N <br />0 <br />LAST PLOT DATE <br />. . <br />May 8, 2023 <br />O <br />2ND FLOOR <br />J <br />ELECTRICAL PLAN <br />A&B <br />