Laserfiche WebLink
4. <br />11'-1 3/16" <br />r--------- <br />I r— <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I � <br />NEW <br />REAR PORCH: <br />416 <br />SF <br />NEW <br />SIDE COVER <br />30 <br />5F <br />NEW <br />COV. AREAS: <br />506 <br />6F <br />I I <br />_ I I <br />� I I <br />in I� <br />■ <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />49'-2 3/8" <br />S'-0" <br />W.P. <br />GF.I. <br />W.P. <br />GF.I. <br />OPTIONAL - U.L. APPROVED Porch <br />PRE-FAB (WD. BURNING) ZERO 28'-0" X <br />CLEARANCE FIREPLACE UNIT 10'-0" CLG, HGt. <br />V-1 3/16" <br />S'-0" <br />12"A2" CM COLUMN <br />(TYP. 6 PL.) <br />SWITCHES LOCATED At TIE ELECTRICAL <br />REAR DOOON ` 1 INTO EXISTING- <br />- - - - - - T - - - - - - - - - - - - - - mac- - - - - - - - - - � - - - - - - - T <br />---------I H--------------J L_------------------I r------- <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />EXISTING HOUSE <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />I I I I <br />I I 99b�' I I <br />I I <br />LI I <br />------------------------------------------------J <br />L- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -I <br />100.00' <br />If <br />0 2' 4' <br />EXISTING HOUSE <br />ME <br />LEGEND <br />r 1 EXISTING WALL OR ITEM <br />L - - - J <br />PLATE HEIGHT = 8'-0" <br />CELL POURED SOLID w/ (905 <br />FROM FTG. TO BOND BEAM <br />OOR <br />PLAN <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />FRAMING NOTES: <br />I <br />ALL INTERIOR DIMENSIONS ARE GIVEN TO THE INDICATED <br />R602.1 GENERAL. WOOD AND WOOD -BASED PRODUCTS USED <br />CENTER OF THE STUD UNLESS NOTED OTHERWISE. <br />FORLOAD-SUPPORTING PURPOSES SHALL CONFORM TO THE <br />APPLICABLE PRO -VISIONS OF THIS SECTION. <br />ALL EXTERIOR DIMENSIONS ARE GIVEN TO THE FACE OF THE <br />STUD OR FACE OF BLOCK (AS APPROPRIATE) WHICH LINES <br />R602.1.8 WOOD STRUCTURAL PANELS. WOOD STRUCTURAL <br />WITH THE FOUNDATION BELOW. <br />PANELSHEATHING SHALL CONFORM TO DOC PS 1, DOC PS 2 OR, <br />WHENMANUFACTURED IN CANADA, CSA 0437 OR CSA 0325. <br />ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE <br />PANELSSHALL BE IDENTIFIED FOR GRADE, BOND <br />PRESSURE TREATED OR APPROVED CEDAR, OR HAVE 15 LB. <br />CLASSIFICATION, AND PER-FORMANCE CATEGORY BY A GRADE <br />FELT BARRIER. <br />MARK OR CERTIFICATE ORINSPECTION ISSUED BY AN APPROVED <br />AGENCY. <br />SEE SHEETS - S1, S2 AND ADDITIONAL -S" SHEETS <br />R602.1.9 PARTICLEBOARD. PARTICLEBOARD SHALL CONFORM <br />FOR ADDITIONAL STRUCTURAL DETAILS / NOTES <br />TOANSI A208.1. PARTICLEBOARD SHALL BE IDENTIFIED BY <br />THEGRADE MARK OR CERTIFICATE OF INSPECTION ISSUED BY <br />R602.1 GENERAL. WOOD AND WOOD -BASED PRODUCTS USED <br />ANAPPROVED AGENCY. <br />FORLOAD-SUPPORTING PURPOSES SHALL CONFORM TO THE <br />APPLICABLE PRO -VISIONS OF THIS SECTION. <br />R602.1.10 FIBERBOARD. FIBERBOARD SHALL CONFORM TOASTM <br />C208. FIBERBOARD SHEATHING, WHERE USED STRUCTUR-ALLY, <br />R602.1.1 SAWN LUMBER. SAWN LUMBER SHALL BE <br />SHALL BE IDENTIFIED BY AN APPROVED AGENCY AS <br />IDENTIFIEDBY A GRADE MARK OF AN ACCREDITED LUMBER <br />CONFORMING TO ASTM C208. <br />GRADING ORINSPECTION AGENCY AND HAVE DESIGN VALUES <br />CERTIFIED BY ANACCREDITATION BODY THAT COMPLIES WITH <br />R602.2 GRADE. STUDS SHALL BE A MINIMUM NO. 3, STANDARD <br />DOC PS 20. IN LIEUOF A GRADE MARK, A CERTIFICATION OF <br />ORSTUD GRADE LUMBER. <br />INSPECTION ISSUED BY ALUMBER GRADING OR INSPECTION <br />EXCEPTION: BEARING STUDS NOT SUPPORTING FLOORS AND <br />AGENCY MEETING THE REQUIRE-MENTS OF THIS SECTION SHALL <br />NON -BEARING STUDS SHALL BE PERMITTED TO BE UTILITY <br />BE ACCEPTED. <br />GRADE LUMBER,PROVIDED THE STUDS ARE SPACED IN <br />ACCORDANCE WITH TABLER602. 3( 5). <br />R602. 1.2 END -JOINTED LUMBER. APPROVED <br />END-JOINTEDLUMBER IDENTIFIED BY A GRADE MARK <br />R602.3 DESIGN AND CONSTRUCTION. EXTERIOR WALLS OF <br />CONFORMING TO SECTIONR602.1 SHALL BE PERMITTED TO BE <br />WOOD -FRAME CONSTRUCTION SHALL BE DESIGNED AND <br />USED INTERCHANGEABLY WITHSOLID-SAWN MEMBERS OF THE <br />CONSTRUCTED INACCORDANCE WITH THE PROVISIONS OF THIS <br />SAME SPECIES AND GRADE. END -JOINTED LUMBER USED IN AN <br />CHAPTER AND FIGURESR602.3(1) AND R602.3(2), OR IN <br />ASSEMBLY REQUIRED ELSEWHERE INTHIS CODE TO HAVE A <br />ACCORDANCE WITH AWC NDS.COMPONENTS OF EXTERIOR WALLS <br />FIRE -RESISTANCE RATING SHALL HAVE THE <br />SHALL BE FASTENED IN ACCORDANCEWITH TABLES R602.3(1) <br />DES-IGNATION "HEAT RESISTANT <br />THROUGH R602.3(4). WALL SHEATHINGSHALL BE FASTENED <br />ADHESIVE" OR "HRA " INCLUDED INITS GRADE MARK. <br />DIRECTLY TO FRAMING MEMBERS AND, WHEREPLACED ON THE <br />R602.1.3 STRUCTURAL GLUED -LAMINATED TIMBERS. <br />EXTERIOR SIDE OF AN EXTERIOR WALL, SHALL BE CAPA-BLE <br />GLUED -LAMINATED TIMBERS SHALL BE MANUFACTURED AND <br />OF RESISTING THE WIND PRESSURES LISTED IN TABLE <br />IDENTIFIED ASREQUIRED IN ANSI/AITC A190.1 AND ASTM <br />R301.2(2)ADJUSTED FOR HEIGHT AND EXPOSURE USING TABLE <br />D3737. <br />R301.2(3) ANDSHALL CONFORM TO THE REQUIREMENTS OF <br />TABLE R602.3(3). WALLSHEATHING USED ONLY FOR EXTERIOR <br />R602.1.4 STRUCTURAL LOG MEMBERS. STRUCTURAL LOG <br />WALL COVERING PURPOSES SHALLCOMPLY WITH SECTION R703. <br />MEM-BERS SHALL COMPLY WITH THE PROVISIONS OF ICC 400. <br />STUDS SHALL BE CONTINUOUS FROM SUPPORT AT THE SOLE <br />PLATE TO ASUPPORT AT THE TOP PLATE TO RESIST LOADS <br />R602.1.5 STRUCTURAL COMPOSITE LUMBER. <br />PERPENDICULAR TO THEWALL. THE SUPPORT SHALL BE A <br />STRUCTURALCAPACITIES FOR STRUCTURAL COMPOSITE LUMBER <br />FOUNDATION OR FLOOR, CEILING ORROOF DIAPHRAGM OR SHALL <br />SHALL BE ESTAB-LISHED AND MONITORED IN ACCORDANCE WITH <br />BE DESIGNED IN ACCORDANCE WITHACCEPTED ENGINEERING <br />ASTM D5456. <br />PRACTICE. <br />EXCEPTION: JACK STUDS, TRIMMER STUDS AND CRIPPLE STUDS <br />R602.1.6 CROSS -LAMINATED TIMBER. CROSS -LAMINATED <br />ATOPENINGS IN WALLS THAT COMPLY WITH TABLES R602.7(1) <br />TIM-BER SHALL BE MANUFACTURED AND IDENTIFIED AS <br />ANDR602.7(2). <br />REQUIRED BYANSI/APA PRG 320. <br />R602.1.7 ENGINEERED WOOD RIM BOARD. ENGINEERED WOODRIM <br />BOARDS SHALL CONFORM TO ANSI/APA PRR 410 OR SHALLBE <br />EVALUATED IN ACCORDANCE WITH ASTM D7672. <br />STRUCTURALCAPACITIES SHALL BE IN ACCORDANCE WITH <br />EITHER ANSI/APAPRR 410 OR ESTABLISHED IN ACCORDANCE <br />WITH ASTM D7672.RIM BOARDS CONFORMING TO ANSI/APA PRR <br />410 SHALL BEMARKED IN ACCORDANCE WITH THAT STANDARD. <br />INTERIOR ELECTR I CAL OUTLET LOCATIONS <br />PADDLE FAN SWITCH <br />(LOCATE OVER FAN <br />LIGHT SWITCH) <br />LIGHT SWITCH <br />DUPLEX OUTLET At <br />KITCHEN COUNTER, REFRIG., <br />WASHER AND GARAGE OUTLETS <br />DUPLEX OUTLET AT <br />° o VANITY COUNTER <br />® STANDARD <br />DUPLEX OUTLET <br />� v - <br />� a <br />0 <br />n <br />ELECTRICAL SYMBOLS LEGEND <br />CEILING LIGHT ® 200 AMP. PANEL ® TELEVISION PRE -WIRE <br />{R} %RECESSED CAN LIGHT Nr---_—_ � LIGHT <br />110v DUPLEX RECEPTACLE ----e SHOP FLUORESCENT TELEPHONE PRE -WIRE <br />`0 --_----' ' SMOKE ALARM <br />2'X 4' FLUORESCENT 22OY OUTLET LIGHT CARBON MONOXIDE® DETECTOR <br />F.I. 11OV GF.I. OUTLET JO JUNCTION BOX <br />_=_17 TRACK LIGHTING <br />PUSH BUTTON (G.D.O., <br />SWITCHED DUPLEX REC. 4 <br />pt7p�p� BEAUTY BAR LIGHT ' CHIMES, ETC.) <br />® OUTLET (HWH, AH, ETC.) _ FLOOD LIGHT <br />$ SINGLE POLE SWITCH \\ BRACE 4 ® DOOR BELL CHIME <br />$3 THREE WAY LIGHT SWITCH \\ / PRE -WIRE �i�'� ELECTRICAL WIRING <br />FOR FAN <br />vy GARAGE DOOR OPENER EXHAUST FAN <br />L J <br />LIG-IT/EX. FAN <br />ELECTRICAL NOTES <br />ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO ALL APPLICABLE CODES SUCH AS THE NATIONAL. <br />ELECTRICAL CODE 2011, LOCAL ORDINANCES AND POWER COMPANY REGULATIONS. <br />SUBCONTRACTOR SHALL BE LICENSED, CARRY ALL APPLICABLE.INSURANCE, AND HAVE A CURRENT COUNTY <br />OCCUPATIONAL LICENSE. AS ALLOWED, CONNECT ADDITIONAL ELECTRICAL TO EXISTING CIRCUITS. <br />SUBCONTRACTORS SHALL INCLUDE ALL SPECIAL FEES AND PERMITS, LABOR AND MATERIAL, EQUIPMENT AND <br />ELECTRICAL ENGINEERING NECESSARY TO PROVIDE AN APPROVED WORKING SYSTEM. LIGHT FIXTURES EXCLUDED <br />EXCEPT FOR FLUORESCENT FIXTURES AND RECESSED LIGHTS. <br />CONCRETE -ENCASED ELECTRODE. AN ELECTRODE ENCASED BY AT LEAST 2" OF CONCRETE, LOCATED WITHIN <br />AND NEAR THE BOTTOM OF THE CONCRETE FOUNDATION OR FOOTING THAT IS IN DIRECT CONTACT WITH THE <br />EARTH, CONSISTING OF AT LEAST 20 FT. OF ONE OR MORE BARE OR ZINC GALVANIZED OR OTHER ELECTRICITY <br />CONDUCTIVE COATED STEEL REINFORCING BARS OR RODS OF NOT LESS THAN 1/2 INCH DIAMETER OR CONSISTING <br />OF At LEAST 20 FEET OF BARE COPPER CONDUCTOR NOT SMALLER THAN 4 AWG. REINFORCING BARS SHALL BE <br />PERMITTED TO 15E BONDED TOGETHER BY THE USUAL STEEL TIE WIRES OR OTHER EFFECTIVE MEANS." <br />210.12 ARC -FAULT CIRCUIT -INTERRUPTER PROTECTION <br />(A) DEFINITION: ARC -FAULT CIRCUIT INTERRUPTER (AFCI) A DEVICE INTENDED TO PROVIDE PROTECTION FROM <br />THE EFFECTS OF ARC FAULTS BY RECOGNIZING CHARACTERISTICS UNIQUE t0 ARCING AND BY FUNCTIONING TO <br />DE -ENERGIZE THE CIRCUIT WHEN AN ARC FAULT IS DETECTED. <br />(13) DWELLING UNITS. ALL 120-VOLT, SINGLE PHASE, 15- AND 20-AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS <br />INSTALLED N DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING RDOMS, PARLORS, LIBRARIES, DENS, <br />BEDROOMS, SINROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, AND OTHER SPECIFIED ROOMS OR AREAS <br />SHALL BE <br />PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER COMBINATION -TYPE, INSTALLED TO PROVIDE <br />PROTECTION OF THE BRANCH CIRCUIT. <br />CARBON MONOXIDE ALARMS <br />R315.1 CARBON MONOXIDE PROTECTION. EVERY SEPARATE BUILDING OR AN ADDITION TO AN EXISTING BUILDING FOR <br />WHICH A PERMIT FOR NEW CONSTRUCTION 15 ISSUED AND HAVING A FOSSIL-FUEL-BUWIW_% HEATER OR APPLIANCE, A <br />FIREPLACE, AN ATTACHED GARAGE, OR OTHER FEATURE, FIXTURE, OR ELEMENT THAT EMITS CARBON MONOXIDE AS A <br />BYPRODUCT OF COMBUSTION SHALL HAVE AN OPERATIONAL CARBON MONOXIDE ALARM INSTALLED WITHIN 10 FEET <br />(3048 mm) OF EACH ROOM USED FOR SLEEPING PURPOSES. <br />EXCEPTION: THIS SECTION SHALL NOT APPLY TO EXISTING BUILDINGS THAT ARE UNDERGOING ALTERATIONS OR <br />REPAIR UNLESS THE ALTERATION IS AN ADDITION AS DEFINED IN SECTION R315.13. <br />R315A CARBON MONOXIDE ALARM. THE REQUIREMENTS OF SECTION R315J SHALL BE SATISFIED BY PROVIDING FOR <br />ONE OF THE FOLLOWING ALARM INSTALLATIONS: <br />(1) A HARD -WIRED CARBON MONOXIDE ALARM. <br />(2) A BATTERY -POWERED CARBON MONOXIDE ALARM. <br />(3) AWARD -WIRED COMBINATION CARBON MONOXIDE AND SMOKE ALARM. <br />(4) A BATTERY -POWERED COMBINATION CARBON MONOXIDE AND SMOKE ALARM. <br />R315.12 COMBINATION ALARMS. COMBINATION SMOKE/CARBON MONOXIDE ALARMS SHALL BE LISTED AND LABELED <br />BY A NATIONALLY RECOGNIZED TESTING LABORATORY. <br />R315.13 ADDITION SHALL MEAN: AN EXTENSION OR INCREASE IN FLOOR AREA, NUMBER OF STORIES OR HEIGHT OF A <br />BUILDING OR STRUCTURE <br />U <br />C <br />Q <br />O <br />L. <br />0 <br />c <br />O <br />N <br />C <br />O <br />U) <br />i <br />(D <br />C <br />i <br />O <br />C) <br />00 <br />O <br />CV <br />0 <br />H <br />_ <br />0 <br />tY <br />0_ <br />O <br />0 <br />