NO. DESCRIPTION DATE <br />PLUMBING FIXTURE SCHEDULE SYMBOL LEGEND ABBREVIATIONS GENERAL NOTES <br />SYMBOL DESCRIPTION SYMBOL DESCRIPTION 1. REFERENCE THE SPECIFICATIONS FOR MATERIAL AND EQUIPMENT INSTALLATION <br />S-1 CA - COMPRESSED AIR CA - COMPRESSED AIR <br />STANDARDS. <br />SM1 SHOCK ARRESTER AFF -ABOVE FINISH FLOOR 2. THE PLUMBING INSTALLATION SHALL COMPLY WITH ALL STATE AND LOCAL CODES. <br />=AV. _ - _ -ACID VENT AW - ACID WASTE <br />SINGLE COMPARTMENT SELF RIMMING SINK CONSTRUCTED OF TYPE 30218-8 STAINLESS STEEL, 22' PISTON OPERATED, TYPE'K' COPPER BARREL WITH BRASS THREADED ADAPTOR. ALL JOINTS SHALL AW - ACID WASTE AV - ACID VENT 3. UTILITIES AND SERVICES INDICATED ARE TAKEN FROM VARIOUS OLD AND NEW SURVEYS, AS- <br />X 19" X 5-1/2' DEEP. INTERIOR AND TOP SURFACES SHALL BE POLISHED TO A HIGH LUSTER FINISH. BE MADE WITH 95-5 LEAD FREE SOLDER. THE PISTON SHALL BE EQUIPPED WITH TWO (2)'0' RINGS TO _ _ _ CB - CATCH BASIN BUILT RECORDS AND FIELD INVESTIGATIONS. UNFORSEEN CONDITIONS PROBABLY EXIST <br />_ =AW- _ _ - -BELOW GROUND ACID WASTE CD - CONDENSATE DRAIN <br />PROVIDE SINK WITH STAINLESS STEEL CRUMB CUP STRAINER. PROVIDE FIXTURE PUNCHED FOR PROVIDE A PERMANENT MECHANICAL BARRIER BETWEEN FLUID AND PRE -LOAD AIR CHARGE. - - - AND NEW WORK MAY NOT BE FIELD LOCATED EXACTLY AS SHOWN ON DRAWINGS. <br />3-HOLE FAUCET INSTALLATION ON 4-INCH CENTERS. ARRESTORS MAY BE INSTALLED IN VERTICAL AND HORIZONTAL POSITION. CD - ABOVE GROUND CONDENSATE DRAIN CFH - CUBIC FEET PER HOUR COOPERATION WITH OTHER TRADES IN ROUTING AND BURIAL DEPTHS, AS DETERMINED <br />CO -CLEANOUT DURING CONSTRUCTION, WILL BE NECESSARY. <br />8-INCH WIDESPREAD COMBINATION CHROME PLATED BRASS FAUCET, WITH RIGID GOOSENECK (5.3/8' THE ARRESTOR SHALL BE FULLY GUARANTEED FOR ENTIRE SYSTEM LIFE. _-CD-_ _ _ - - BELOW GROUND CONDENSATE DRAIN CONT - CONTINUATION <br />WIDE) SPOUT AND 2.0 GPM LAMINAR FLOW REGULATOR, VANDAL RESISTANT 4-INCH WRIST BLADE DA -DENTAL AIR CW - DOMESTIC COLD WATER 4. FIELD VERIFY EXISTING INSTALLATIONS. MODIFY EXISTING PLUMBING SYSTEMS, WHICH ARE <br />HANDLES WITH COLOR CODED INDEXES AND RENEWABLE SEATS IN MONEL, OUTLET OF SPOUT TO BE NOTE: DI - DEIONIZED WATER TO REMAIN ACTIVE, TO FACILITATE RECONNECTION AND EXTENSION OF THE NEW WORK. <br />DI - DEIONIZED WATER DN - DOWN <br />MINIMUM OF 5- INCHES ABOVE RIM OF FIXTURE. DS - DOWNSPOUT <br />DV -DENTAL VACUUM 5. NOTIFY OWNER AT LEAST 24 HOURS PRIOR TO INTERRUPTING EXISTING SERVICE. <br />SHOCKARRESTORS SHALL BE PROVIDED AT ALL FIXTURES AND BATTERIES OF FIXTURES WHETHER DWG - DRAWING SCHEDULE DISCONNECTION AND TIE-INS TO MINIMIZE DISRUPTION OF SERVICES. SERVICES <br />318 INCH I.P.S. CHROME PLATED ANGLE SUPPLY, LOOSE KEY STOP, REDUCER, WROUGHT BRASS OR NOT THEY ARE SHOWN ON THE DRAWINGS. _ _ _ - DOMESTIC COLD WATER EXIST OR (E) - EXISTING ARE NOT TO BE LEFT DISRUPTED DURING NON -NORMAL CONTRACTOR WORKING HOURS. <br />DEEP BELL FLANGE ESCUTCHEON AND 1 /2" CHROME PLATED COPPER EXTENSION TUBE WITH SWEAT - DOMESTIC HOT WATER ETR - EXISTING TO REMAIN <br />HEIT <br />CONNECTION. BASIS OF DESIGN °F -DEGREE FAHREN-DOMESTIC HOT WATER RETURN FCO - FLOOR FAHREN 6. PLANS ARE NOT COMPLETELY TO SCALE. PIPE ROUTING SHOWN IS SCHEMATIC AND IS NOT <br />F- FLOOR DRAIN INTENDED TO INDICATE EXACT ROUTING. CONTRACTOR SHALL PROVIDE ANY ADDITIONAL <br />CHROME PLATED 17 GAUGE 1-1/2 X 1-1/2 P-TRAP WITH CLEANOUT. PRECISION PLUMBING PRODUCTS - SC SERIES FOF - FUEL OIL FILL OFFSETS AND FITTINGS REQUIRED FOR PROPER INSTALLATION AND TO MAINTAIN <br />FOF - FUEL OIL FILL CLEARANCES. VERIFY STRUCTURAL, MECHANICAL AND ELECTRICAL INSTALLATIONS AND <br />BASIS OF DESIGN FOG - FUEL OIL GAGE FOG - FUEL OIL GAGE OTHER POTENTIAL OBSTRUCTIONS AND ROUTE PIPING TO AVOID INTERFERENCES. <br />FOR - FUEL OIL RETURN FOR - FUEL OIL RETURN <br />FOS - FUEL OIL SUPPLY 7. PROVIDE ALL OFFSETS AND FITTINGS AND MAKE CONNECTION TO SITE UTILITIES. <br />SINK - ELKAY LRAD-2219/LK-99 <br />FOS -FUEL OIL SUPPLY FOV -FUEL OIL VENT <br />FAUCET -CHICAGO.78&E29VP _ FS - FLOOR SINK 8. CONCEAL PIPING ABOVE CEILINGS, WITHIN WALLS OR CHASES EXCEPT IN MECHANICAL <br />- =FOV= _ _ _ - FUEL OIL VENT ROOMS OR AS SPECIFICALLY NOTED. <br />SUPPLIES - MCGUIRE - H170LK - _ = G -GAS <br />TRAP - MCGUIRE - 8912 G -GAS GPH - GALLONS PER HOUR <br />GPM - GALLONS PER MINUTE 9. PROVIDE ACCESS PANELS FOR ALL VALVES CONCEALED IN WALLS OR ABOVE NON- <br />GR - KITCHEN WASTE (GREASE) GR - KITCHEN WASTE (GREASE) ACCESSIBLE CEILINGS. <br />A - MEDICAL COMPRESSED AIR HB - HOSE BIBB <br />HD - HUB DRAIN 10. SLEEVE AND/OR FIRESTOP ALL PENETRATIONS THROUGH RATED WALLS, CEILINGS, AND <br />W V - MEDICAL VACUUM H- DOMESTIC HOT WATER FLOORS WITH U/L LISTED ASSEMBLIES. FIRESTOP ASSEMBLIES SHALL BE EQUAL TO OR <br />N - NITROGEN H -DOMESTIC HOT WATER RECIRCULATING <br />IE -INVERT ELEVATION EXCEED THE RATING OF THE WALL, CEILING OR FLOOR. SEE ARCHITECTURAL DRAWINGS <br />IE N20 - NITROUS OXIDE IW - INDIRECT WASTE FOR FINAL FINISHES. <br />O -OXYGEN KW - KILOWATT 11. FLASH AND COUNTER -FLASH ROOF PENETRATIONS. <br />LBS -POUNDS <br />S - ABOVE GROUND SANITARY MA OR A -MEDICAL AIR 12. WHEN BEAM SLEEVE PENETRATIONS ARE NECESSARY, COORDINATE PENETRATIONS WITH <br />=S= _ _ _ _ -BELOW GROUND SANITARY MV OR V -MEDICAL VACUUM ALL TRADES, THE ARCHITECT AND THE STRUCTURAL ENGINEER. <br />MH -MANHOLE <br />- SANITARY VENT NI OR N -NITROGEN 13. PROVIDE FOUNDATION PAD PENETRATION SLEEVES. ALLOW 1" MINIMUM CLEARANCE <br />N20 -NITROUS OXIDE BETWEEN SLEEVE INSIDE SURFACE AND PIPE EXTERIOR. <br />ST - ABOVE GROUND STORM NC - NORMALLY CLOSED <br />=ST= - - - _ - BELOW GROUND STORM NIC - NOT IN CONTRACT 14. SEE ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING HEIGHTS. <br />NO - NORMALLY OPEN <br />STO - OVERFLOW STORM DRAIN NP - NON -POTABLE WATER 15. PROVIDE AUTOMATIC TRAP PRIMERS FOR FLOOR DRAIN TRAP SEALS. <br />=STO= - - _ - BELOW GROUND OVERFLOW STORM NTS - NOT TO SCALE <br />OD - OUTSIDE DIAMETER 16. PROVIDE AN AIR GAP, WHEN REQUIRED BY CODE, SERVING INDIVIDUAL FIXTURES, DEVICES, <br />SW - SOFT COLD WATER OX OR O -OXYGEN APPLIANCES AND APPARATUS. <br />VAC -VACUUM AIR PRV - PRESSURE REDUCING VALVE <br />(AIR) PSI - POUNDS PER SQUARE INCH 17. ALL EXPOSED PIPE AND FITTINGS IN FINISHED AREAS SHALL BE CHROME PLATED. <br />WO - WASTE OIL PVC - POLYVINYL CHLORIDE PIPE <br />RD - ROOF DRAIN 18. MOUNT HOSE BIBBS 24" ABOVE FINISHED GRADE. <br />WOV - WASTE OIL VENT RPBP - REDUCED PRESSURE BACKFLOW PREVENTOR <br />M - WATER METER SAN - SANITARY 19. PROVIDE CLEANOUTS IN ACCORDANCE WITH ALL STATE AND LOCAL CODES. INSTALL <br />SD - STORM DRAIN CLEANOUT WITH COVER FLUSH TO FINISH SURFACE. <br />�"C-- - - - HOSE BIBB OR WALL HYDRANT SF - SQUARE FEET <br />SH - SHEET 20. COORDINATE EXACT FLOOR DRAIN LOCATIONS WITH ARCHITECTURAL DRAWINGS. SET <br />COI - CLEAN OUT PLUG ST - STORM FLOOR DRAINS BELOW FINISHED FLOOR TO ALLOW FOR FLOOR SLOPING TO THE DRAIN. <br />STO - OVERFLOW STORM DRAIN <br />C4 I F- -WALL CLEANOUT SW - SOFT COLD WATER 21. COORDINATE PIPING WITH ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMERS, ETC.) <br />COI - WALL CLEANOUT V - VENT PRIOR TO ANY INSTALLATION. DO NOT ROUTE ANY PIPING OVER ANY ELECTRICAL PANELS <br />CO VAC -VACUUM UNDER ANY CIRCUMSTANCES. ANY PIPING RUN OVER PANELS SHALL BE RE-ROUTED AT NO <br />- FLOOR CLEAN OUT VC - VACUUM CLEANING ADDITIONAL COST. <br />VTR - VENT THRU ROOF <br />FD W FD CC - FLOOR DRAIN WCO - WALL CLEANOUT 22. ALL WALL MOUNTED LAVATORIES SHALL BE ATTACHED TO FLOOR MOUNTED CARRIER <br />WTR - WATER DESIGNED TO WITHSTAND A VERTICAL LOAD OF 250 POUNDS ON THE FRONT OF THE <br />(p1 -ROOF DRAIN FIXTURE. <br />FS M - FLOOR SINK 23. PROVIDE SANITARY WASTE, VENT, DOMESTIC WATER, ETC. ROUGH -IN AND MAKE FINAL <br />Elm- SHUT-OFF VALVE IN VALVE BOX CONNECTIONS (TO INCLUDE PROVIDING ALL NECESSARY RELATED STOPS, VALVES, TRAPS, <br />ETC. AND MAKE READY FOR USE) TO ALL EQUIPMENT, WHETHER FURNISHED BY THIS <br />- SHUTOFF VALVE CONTRACTOR OR FURNISHED BY OTHERS. <br />-�61 - BALL VALVE 24. PROVIDE CERTIFIED COPY OF MEDICAL GAS TEST REPORT AT FINAL A.H.C.A. INSPECTION. <br />- CALIBRATED BALANCING VALVE <br />-N-- - CHECK VALVE (SWING) <br />-D�- -PRESSURE REDUCING VALVE <br />- SOLENOID OPERATED VALVE <br />- REDUCED PRESSURE BACKFLOW PREVENTER <br />}-- - RELIEF OR SAFETY VALVE <br />`*-bG' - GAS COCK <br />- A - GAS PRESSURE REGULATOR <br />♦ G - SHUTOFF VALVE ON RISER SHEET NAME ISSUED <br />rC -GAS COCK ON RISER <br />P0.1 GENERAL INFO, LEGENDS & SHEET INDEX Yes <br />- CONNECTION, TOP P1.1 PLUMBING AND MECHANICAL FLOOR PLAN Yes <br />y -CONNECTION, BOTTOM <br />G - ELBOW, TURNED DOWN <br />- ELBOW, TURNED UP <br />- TEE, TURNED UP <br />- TEE, TURNED DOWN <br />C - CAP <br />- DIRECTION OF FLOW <br />, = AP-XX - ALARM PANEL <br />m. MAP-XX - MASTER ALARM PANEL <br />I(.XX) M O-XX - MEDICAL GAS OUTLET <br />U ICU MGV-XX - MEDICAL GAS VALVE BOX <br />-s - CONNECT TO EXISTING <br />Q-- o - DEMOLISH TO POINT INDICATED <br />1Q - REVISION REFERENCE <br />1 - DETAIL REFERENCE: TOP -DETAIL#, <br />P2.01 BOTTOM -DRAWING# SHOWN ON <br />NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT <br />2 <br />IL <br />� <br />coo <br />.50 <br />�N� <br />E <br />L' <br />m �CD04 <br />o <br />Ce-0 <br />�� 4 <br />Qti-ti� <br />0 <br />COS z <br />U <br />rn 0 '-T <br />c� <br />� <br />z <br />00 d� <br />� <br />.O <br />t <br />L <br />LO <br />W <br />Z <br />V <br />W w <br />~ <br />W <br />Z u <br />o` <br />�a <br />Z °C <br />W <br />rA <br />r_� <br />r•� <br />Q <br />0 <br />4-j <br />�1 <br />• J <br />•� <br />O <br />O <br />rTl <br />r...4 <br />0 <br />�T <br />v <br />H <br />-Uo <br />g$ <br />Lu <br />U <br />° <br />Q <br />Fz <br />W <br />z <br />0 <br />0 <br />J <br />x <br />W <br />3 <br />U <br />oc <br />W <br />> a <br />¢p <br />x <br />ICE� <br />W <br />of <br />Nab <br />SEAT. Aaron Lee Johnson, P.E. <br />Florida License #71576 <br />�'• No 71576 •• 2 <br />yt ; * •: it <br />D: z <br />'13 STATE OF 441% <br />SHEET TITLE: <br />GENERAL INFO, LEGENDS & <br />SHEET INDEX <br />DATE: 10/25/17 <br />SCALE: AS SHOWN <br />SHEET NO.: <br />P0.1 <br />it <br />