NO. DESCRIPTION DATE <br />as <br />co <br />N <br />0 <br />0 <br />ELECTRICAL SYMBOL LEGEND <br />BASIC MATERIALS <br />BASIC MATERIALS CONT. <br />TELEPHONE/COMPUTER RACEWAY SYSTEM <br />SYMBOL DESCRIPTION <br />SYMBOL DESCRIPTION <br />SYMBOL DESCRIPTION <br />Sa SINGLE POLE SWITCH <br />- 0 CONDUIT TURNING UP <br />UP <br />X = MOUNTING (F)LUSH, (S)URFACE, (M)ODULAR <br />FURNITURE ADAPTOR (P)OLE, F(L)OOR, & (R)ACEWAY <br />(SUBSCRIPT INDICATES ITEM CONTROLLED) <br />-*DN CONDUIT TURNING DOWN <br />-N = # OF VOICE JACKS <br />S3 THREE-WAY SWITCH <br />N = # OF DATA JACKS <br />CONDUIT STUB <br />N = # OF FIBER PORTS <br />S4 FOUR-WAY SWITCH <br />N = # OF VIDEO PORTS <br />-� CONDUIT CONTINUED <br />SP SINGLE POLE SWITCH <br />X N N N N COMMUNICATIONS "INFORMATION OUTLET" MTD. AT <br />WITH PILOT LIGHT <br />FLEXIBLE CONDUIT <br />410 ROOM # - OUTLET # RECEPTACLE HEIGHT UNLESS OTHERWISE NOTED. <br />RECEPTACLE <br />C = ABOVE THE COUNTER REFER TO SPECIFICATIONS FOR MANUFACTURER'S <br />DUPLEX <br />- - - - - EXISTING TO BE REMOVED <br />W = WALL MOUNTED PART NUMBER. <br />e- TWIST LOCK RECEPTACLE <br />EXISTING TO REMAIN <br />T <br />SURGE PROTECTION TYPE (TVSS) <br />EXISTING AFFECTED BY THIS PROJECT <br />DUPLEX RECEPTACLE WITH <br />- - - - FUTURE <br />EACH HALF ON SEPARATE CIRCUIT <br />(BREAKER SHALL BE TWO POLE WITH COMMON TRIP) <br />NEW <br />DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER <br />LIGHTING <br />NURSE CALL SYSTEMS <br />DUPLEX SAFETY RECEPTACLE MOUNT <br />COVERPLATES WITH SPANNER HEAD SCREWS <br />A FIXTURE DESIGNATION <br />DUPLEX RECEPTACLE WITH TOP HALF SWITCHED <br />LED / FLUORESCENT FIXTURE <br />ENHANCED PATIENT STATION WITH <br />INTEGRAL CODE BLUE AND STAFF ASSIST <br />SIMPLEX RECEPTACLE (EWC DENOTES <br />a �_ LOWER CASE LETTER INDICATES <br />STAFF EMERGENCY STATION <br />-� <br />ELECTRIC WATER COOLER. COORDINATE WITH EWC <br />EWC <br />CONTROL CIRCUIT SWITCH LEG <br />INSTALLER FOR MOUNTING HEIGHT) <br />STAFF EMERGENCY ANNUNCIATOR <br />CIRCUIT NUMBER <br />GFI RECEPTACLE MOUNTED ABOVE COUNTER <br />--® CODE BLUE EMERGENCY STATION <br />TWO DUPLEX RECEPTACLES WITH COMMON COVER <br />LED I FLUORESCENT FIXTURE DIAGONAL SHADING DENOTES <br />© <br />TO LIGHT FIXTURE CONNECTED TO CRITICAL BRANCH. <br />CORRIDOR DOME LIGHT CEILING MOUNTED <br />TWO DUPLEX RECEPTACLES WITH COMMON COVER <br />HID OR LED I FLUORESCEN FIXTURE <br />O CORRIDOR ZONE LIGHT <br />MOUNTED ABOVE COUNTER <br />EXIT LIGHT FIXTURE <br />ISOLATED GROUND DUPLEX RECEPTACLE, <br />® DIRECTION ARROWS AS SHOWN <br />IG (ORANGE DEVICE) <br />(SHADED QUADRANT INDICATES FACE(S) OF FIXTURE) <br />DUPLEX RECEPTACLE <br />NOTE: <br />TICK MARKS SHOWN ON ANY DEVICE REPRESENTS <br />RECEPTACLE CONNECTED TO THE EMERGENCY CIRCUIT <br />GENERAL DEMOLITION NOTES <br />GENERAL NOTES <br />(RED DEVICE) TYPICAL FOR ANY DEVICE IN LEGEND <br />LIGHT SWITCHES SHALL BE MOUNTED 48 INCHES ABOVE FINISHED FLOOR TO CENTER LINE OF <br />® SPECIAL PURPOSE RECEPTACLE, RATING AS NOTED <br />1. DEVICE, UNLESS OTHERWISE NOTED. <br />® GROUND BAR <br />1. ALL DEVICES SHOWN ON DEMOLITION PLANS ARE EXISTING. REFER TO SYMBOL <br />LEGEND FOR DEVICE DESCRIPTION. <br />RECEPTACLES SHALL BE LOCATED 18 INCHES ABOVE FINISHED FLOOR TO CENTER LINE OF <br />® CABLE TRAY <br />2. DEVICE, UNLESS OTHERWISE NOTED. ABOVE COUNTER RECEPTACLES SHALL BE MOUNTED 6" <br />2. EXISTING CONDITIONS SHOWN ON THIS DRAWING ARE TAKEN FROM ORIGINAL <br />ABOVE BACK SPLASH TO CENTERLINE OF DEVICE. <br />JUNCTION BOX <br />DRAWINGS AND FIELD INVESTIGATION. ALL EXISTING CONDITIONS MUST BE <br />VERIFIED PRIOR TO BID. FIELD CONDITIONS SHALL GOVEN. <br />3. THE EQUIPMENT GROUNDING TERMINAL BARS OF THE NORMAL AND ESSENTIAL ELECTRICAL <br />O CONDUIT SEAL -OFF FITTINGS <br />3. THE DEMOLITION PLAN IS NOT INCLUSIVE OF ALL ELECTRICAL DEVICES WITHIN THE <br />SYSTEM PANELBOARDS SERVING THE SAME PATIENT VICINITY SHALL BE BONDED TOGETHER WITH <br />AN INSULATED, CONTINUOUS, COPPER CONDUCTOR NOT SMALLER THAN NUMBER 10. <br />PROJECT AREA. IT IS INTENDED TO PROVIDE THE CONTRACTOR WITH A GENERAL <br />®C3 SURGE SUPRESSOR <br />KNOWLEDGE OF THE EXISTING CONDITIONS WITHIN THE PROJECT AREA. ANY <br />4. EQUIPMENT SHALL BE OF MATERIALS SUITABLE FOR AND RATED FOR THE ENVIRONMENT IN WHICH <br />C3 = SERVICE ENTRANCE DEVICE <br />DISCREPANCIES OR CONDITIONS NOT SHOWN ON THIS PLAN SHALL BE BROUGHT <br />THEY ARE TO BE INSTALLED. <br />B3 = DISTRIBUTION BOARD DEVICE <br />TO THE ATTENTION OF THE ENGINEER. THE CONTRACTOR IS RESPONSIBLE FOR ALL <br />A3 = PANELBOARD DEVICE <br />REQUIRED DEMOLITION WHETHER SHOWN ON THE PLANS OR NOT. <br />5. A. WORKING CLEARANCES FOR ELECTRICAL EQUIPMENT SHALL BE IN COMPLIANCE WITH NEC <br />110. <br />SHUNT -TRIP BUTTON - FLUSH MOUNTED UNLESS <br />4. ALL CONDUITS SERVING OTHER SPACES OR FLOORS, THAT RUN THROUGH THE <br />® OTHERWISE NOTED NEMA 311 FOR EXTERIOR LOCATIONS <br />PROJECT AREA SHALL REMAIN ACTIVE DURING CONSTRUCTION, SO AS NOT TO <br />B. THE EXCLUSIVELY DEDICATED SPACE EXTENDING FROM FLOOR TO STRUCTURAL CEILING WITH <br />CAUSE ANY DISRUPTION TO THESE OTHER SPACES. IT IS THE CONTRACTOR'S <br />A WIDTH AND DEPTH OF THE PANELBOARD OR SWITCHBOARD MUST BE CLEAR OF ALL PIPING, <br />RESPONSIBILITY TO INSURE THAT ALL CONDUITS, NEW OR EXISTING, WITHIN THE <br />DUCTS, EQUIPMENT FOREIGN TO THE ELECTRICALEQUIPMENT OR ARCHITECTURAL <br />© POWER CONNECTION TO EQUIPMENT <br />PROJECT AREA ARE PROPERLY SUPPORTED AND PROVIDED WITH BONDING <br />6, APPURTENANCES IN ACCORDANCE WITH NEC 408. <br />BUSHING IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE. <br />MAGNETIC MOTOR STARTER OR CONTACTOR <br />CRITICAL AND LIFE SAFETY LIGHT SWITCHES SHALL BE ROUTED IN CONDUIT AND BOXES OTHER <br />® SIZE AS NOTED <br />5. ALL ITEMS REMOVED UNDER THIS PROJECT SHALL BE DISPOSED OR TURNED OVER <br />7. THAN THAT FOR THE NORMAL BRANCH. ESSENTIAL SYSTEM SWITCHES SHALL BE RED IN COLOR. <br />TO THE OWNER AT THE OWNER'S DISCRETION. <br />EDH-X <br />ELECTRIC DUCT HEATER <br />8. PATIENT CARE AREAS SHALL BE PROVIDED WITH GROUNDING IN ACCORDANCE WITH NEC 517. <br />�M/� <br />6. THIS CONTRACTOR SHALL PROVIDE ELECTRICAL FOR PHASING WORK AS REQUIRED <br />OR DIRECTED BY THE ARCHITECT, REFER TO ARCHITECURAL PHASING PLAN. <br />WHEN ELECTRICAL BOXES ARE LOCATED IN VERTICAL FIRE -RESISTIVE ASSEMBLIES, (CLASSIFIED <br />MOTOR CONNECTION, NUMBER DENOTES HORSEPOWER <br />TEMPORARY ELECTRICAL SERVICES (POWER,LIGHTING, NURSE CALL, FIRE ALARM, <br />AS FIRE/SMOKE AND SMOKE PARTITIONS), THEY SHALL BE INSTALLED WITHOUT AFFECTING THE <br />ETC) SHALL BE PROVIDED WHEN NEW WORK AFFECTS SERVICES NEEDING TO <br />FIRE CLASSIFICATION. ALL OF THE FOLLOWING CONDITIONS SHALL BE MET: <br />®F VARIABLE FREQUENCY DRIVE <br />REMAIN ACTIVE. IF FIRE ALARM SYSTEM CANNOT BE MAINTAINED IN THE <br />CONSTRUCITON AREA, A FIRE WATCH SHALL BE PROVIDED. <br />A. ALL ELECTRICAL BOXES SHALL BE METALLIC. <br />® DIRECT DIGITAL CONTROL PANEL <br />7, UNLESS OTHERWISE NOTED, ALL EQUIPMENT, WIRING DEVICES, LIGHT FIXTURES, <br />B. BOX OPENING SHALL OCCUR ONLY ON ONE SIDE OF FRAMING SPACE. <br />CONDUIT AND WIRE IN THE PROJECT AREA SHALL BE REMOVED. THE CONTRACTOR <br />TRANSFORMER <br />SHALL INVESTIGATE THE PROJECT AREA PRIOR TO BID TO DETERMINE ALL <br />C. BOX OPENING SHALL NOT EXCEED 16 SQUARE INCHES. <br />REQUIRED DEMOLITION. <br />D. ALL CLEARANCES BETWEEN OUTLET BOX AND GYPSUM BOARD SHALL BE COMPLETELY <br />® AUTOMATIC TRANSFER SWITCH <br />B. CONTRACTOR SHALL PROVIDE MEANS OF AUTOMATIC SMOKE DETECTION VIA <br />FILLED WITH JOINT COMPOUND (OR OTHER APPROVED MATERIAL). <br />IL <br />INSTALLED SMOKE DETECTORS CONNECTED TO THE FACITLITY FIRE ALARMS <br />SYSTEM FOR COVERAGE DURING NON -OCCUPIED PERIODS WITHIN THE <br />E. PROVIDE A WALL AROUND OUTLETS LARGER THAN 16 SQUARE INCHES. THE INTEGRITY OF <br />LEI30AR NON -FUSED DISCONNECT SWITCH, SIZE AS NOTED <br />CONSTRUCTION AREA, IF DESIRED, A DOCUMENTED FIRE WATCH OF THE ENTIRE <br />THE WALL RATING SHALL BE MAINTAINED. <br />NF NF DENOTES NON -FUSED <br />AREA PERFORMED IN INCREMENTS NO GREATER THAN ONE HOUR MAY BE <br />I JC1 'OAR <br />PERFORED PROVIDED THAT IT IS DOCUMENTED IN FULL ACCORDANCE WITH NPFA <br />F. THE TOTAL AGGREGATE SURFACE AREA OF THE BOXES SHALL NOT EXCEED 100 SQUARE <br />FUSED DISCONNECT <br />72. COORDINATE ACTIVITY IN FIELD WITH GENERAL CONTRACTOR. <br />INCHES PER 100 SQUARE FEET. <br />t[S] 20AF <br />AR DENOTES AMP RATING OF SWITCH <br />9. "ETR" DENOTES EXISTING ELECTRICAL DEVICE TO REMAIN. <br />G. OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE RESISTIVE ASSEMBLIES SHALL BE <br />MCP AF DENOTES AMP FUSE SIZE <br />SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 24 INCHES. <br />SIZE /�# OF POLES <br />`3013 <br />H. OUTLET BOXES SHALL BE SECURELY FASTENED TO WALL FRAMING MEMBERS. <br />UVI COMBINATION MAGNETIC MOTOR STARTER, <br />3R <br />FACING SHALL BE CUT NOT TO EXCEED 118 INCH <br />0 SIZE AS NOTED, 3 POLE UNLESS OTHERWISE NOTED <br />I. THE OPENING IN THE GYPSUM BOARD <br />9. BETWEEN THE EDGES OF THE OUTLET BOX AND THE EDGES OF THE OPENING. <br />ENCLOSURE NEMA 1 UNLESS NOTED <br />NON-METALLIC RACEWAYS SHALL NOT BE USED TO SERVE ANY PATIENT CARE SPACE. ALL <br />NEMA STARTER SIZE <br />RADIOLOGY NOTES <br />10. WIRING SHALL BE MECHANICALLY PROTECTED BY INSTALLATION IN METALLIC RACEWAYS. <br />^ BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS, <br />11. ALL DEVICES SHALL BE MOUNTED VERTICAL, UNLESS OTHERWISE NOTED. <br />CONTRACTOR SHALL REFER TO THE RADIOLOGY VENDOR DRAWINGS FOR ALL REQUIRED <br />SURFACE MOUNTED <br />ELECTRICAL WORK IN THOSE AREAS, THE VENDOR DRAWINGS IN CONJUCTION WITH THESE <br />12. ALL RECEPTACLES SHALL BE MOUNTED SUCH THAT THE GROUND PIN IS MOUNTED UP. <br />DOCUMENTS SAHLL BE THE BASIS OF BID. All IDENTIFICATIONS INTHEVENDOR DRAWINGS <br />BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS, <br />OF TUSTOMERICONTRACTOR" SHALL BE THE RESPONSIBILITY OF THE "CONTRACTOR". IT IS <br />13. THE NUMBER OF ARROWHEADS ON THE HOMERUNS DENOTES THE NUMBER OF CIRCUITS. <br />FLUSH MOUNTED <br />THE INTENTION OF THE VENDOR DRAWINGS THAT ALL WORK (LABOR, MATERIALS, ETC.) REQUIRED <br />FOR A COMPLETE AND OPERATIONAL SYSTEM SHALL BE PROVIDED. <br />ALL NEW AND EXISTING PANELS AFFECTED BYTHIS PROJECT SHALL BE PROVIDED WITH A NEW <br />BRANCH CIRCUIT PANELBOARD, OVER 250 VOLTS, <br />TYPE WRITTEN DIRECTORY. <br />SURFACE MOUNTED <br />THESE PLANS ARE INTENDED TO GIVE THE CONTRACTOR A GENERGAL KNOWLEDGE OF THE WORK ASSOCIATED WITH <br />THE INTALLATION OF EQUIPMMENT IN THE SELECTED S, IT IS NOT INTENDED TO INDICATE ALL <br />BRANCH CIRCUIT PANELBOARD, OVER 250 VOLTS, <br />-� <br />C,O OR DIMENSIONS ORLOCATIONS OFEQUOLOGY <br />CONNECTIONS, BOX SE ETC, PMENT. ALL EQUIPMENT SHALL E <br />CODES <br />FLUSH MOUNTED <br />INSTALLED PER THE OWNER APPROVED MANUFACTURER'S INSTALLATION DRAWINGS. INSTALLATION SHALL BE <br />COORDINATED IN FIELD WITH RADIOLOGY EQUIPMENT MANUFACTURER. EQUIPMENT MANUFACUTER SHALL SUPLLY <br />1. LIFE SAFETY CODE - NFPA 101(2012). <br />BRANCH CIRCUIT CONDUIT CONCEALED ABOVE <br />FIXED LENGTH CABLES, WHEREBY ALL MEASUREMENTS SHALL BE DETERMINED FROM ELECTRICAL THROUGH RUNS <br />CEILING OR IN WALL. CONDUIT SHALL INCLUDE <br />INDICATED ON VENDOR DRAWINGS, ANY CHANGES TO EQUIPMENT PLACEMENT OR TROUGH ROUTINGS AT JOB SITE WILL <br />2. NATIONAL ELECTRICAL CODE - NFPA 70 (2011). <br />CAUSE THE DELIVERY OF INACCURATE AND ERRONEOUS CABLEE LENGTHS. THIS MAY RESULT IN ADDITOINAL COST FOR <br />3. NATIONAL FIRE PROTECTION ASSOCIATION 72 (2010); NATIONAL FIRE ALARM & SIGNALING CODE. <br />PHASE, NEUTRAL AND GROUND CONDUCTORS <br />REPLACEMENT CABLES AND DELAY EQUIPMENT INSTALLATION. COORDINATE PLACEMENT OF ALL EQUIPMENT WITH <br />4. NATIONAL FIRE PROTECTION ASSOCIATION 99 (2012). HEALTH CARE FACILITIES <br />AS REQUIRED FOR CIRCUITS (UNLESS OTHERWISE NOTED). <br />EQUIPMENT INSTALLER PRIOR TO ROUGH -IN. THE FOLLOWING MUST BE PERFOREDIPROVIDED AS REQUIRED: <br />5. BUILDING CODE: FLORIDA BUILDING CODE (2014 5TH EDITION). <br />6. FGI - GUIDELINES FOR DESIGN & CONSTRUCTION OF THE HEALTH CARE FACILITIES. (2010) <br />BRANCH CIRCUIT CONDUIT CONCEALED IN SLAB, <br />A. REDUNDANT GROUNDING FOR THE PATIENT CARE AREA VIA THE RACEWAY SYSTEM. THE <br />7. NFPA 90A, 2012 EDITION, STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING & VENTILATING SYSTEMS. <br />UNDERGROUND OR UNDER FLOOR. <br />EQUIPMENT MUST BE FASTENED TO THE RACEWAY SYSTEM OR BE BONDED TO THE RACEWAY SYSTEM BY THE USE <br />ELECTRICAL DRAWING INDEX <br />�r _\ BRANCH CIRCUIT CONDUIT EXPOSED <br />OF FLEXIBLE METAL CONDUIT OR BONDING STRAPS. <br />B, SEPERATE RACEWAYS OR CONTINUOUS BARRIERS FOR THE SEPERATION OF INTERCONNECTING CABLES PER <br />SHEET <br />DESCRIPTION <br />ISSUED <br />CIF- GROUND OR GROUND ROD AS NOTED <br />VOLTAGE RATING AND CLASS. POWER AND CLASS 1 CIRCUIT WIRING SHALL BE ROUTED TOTALLY SEPERATE FROM <br />CLASS 2 AND CLASS 3 CIRCUIT WIRING. PROVIDE A CHART AND/OR WIRING DIAGRAM WITH MARKED CABLES TO <br />EO.1 <br />GENERAL INFO, LEGENDS & SHEET INDEX - ELECTRICAL <br />Yes <br />FACILITATE VERIFICATION OF THIS REQUIREMENT. THIS CHART MUST BE DEVELOPED BY THE EQUIPMENT <br />EO.2 <br />ELECTRICAL ONE -LINE DIAGRAM <br />Yes <br />CRITICAL BRANCH CONDUIT <br />MANUFACTURER'S ENGINEERING DEPARTMENT. <br />E1.0 <br />OVERALL FIRST FLOOR PLAN - ELECTRICAL <br />Yes <br />L `\ <br />E1.1 <br />ENLARGED CT ROOM PLAN - FIRST FLOOR - ELECTRICAL <br />Yes <br />r- LIFE SAFETY BRANCH CONDUIT <br />C. RACEWAY SHALL NOT BE EXPOSED, PROVIDE FLUSH MOUNTED WIREWAY AND CONCEALED CONDUIT. CIRCUIT <br />BREAKERS, PANELBOARDS AND EPO STATIONS SHALL BE FLUSH MOUNTED. <br />E2.1 <br />IE3.1 <br />PANEL SCHEDULES <br />Yes <br />EQUIPMENT BRANCH CONDUIT <br />ELECTRICAL SPECIFICATIONS <br />Yes <br />NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. <br />CADDY <br />FINISHED CEILING <br />VOICE CABLE <br />DATA CABLE <br />CENTERED BETWEEN <br />DOOR & CEILING <br />WALL MOUNTED LIGHT FIXTURES (COORDINATE WITH <br />ARCHITECT) <br />AS NOTED ON PLANS hL EXIT <br />ARCHITECT) <br />CENTERED OVER DOOI <br />--- PANELBOARD (WHERE APPLICABLE) <br />,FIRE HORN <br />(OR <br />CHIME) & <br />LIGHT 80" <br />AFF FROM <br />BOTTOM <br />OF DEVICE <br />1" CONDUIT -J DUPLEX 90" FA PULL <br />STUB CONDUIT IN WALL. RECEPTACLE <br />ABOVE <br />CEILING. <br />°o h <br />78" MAX. <br />TO TOP DEVICE 4,4" <br />AFF <br />SINGLE GANG BOX <br />WITH <br />OUTLET PLATE <br />AND <br />JACKS <br />n n REVIEW EACH <br />n n LOCATION FOR <br />HEIGHT <br />n n REQUIREMENT. <br />TYPICAL VOICE / DATA OUTLET <br />No Scale <br />NHD1-4 1'----ENGRAVED PANEL & CIRCUIT <br />COLORED COVERPLATE (BY BRANCH) <br />RED: CRITICAL, LIFE SAFETY, EQUIPMENT <br />LETTERING IS WHITE <br />IVORY: NORMAL BRANCH <br />LETTERING IS BLACK <br />TYPICAL SWITCH <br />3 1 MOUNTING HEIGHTS <br />No Scale <br />STATION <br />h N 0 <br />DUPLEX <br />O RECEPTACLE <br />SWITCH LOCATED IN 1 <br />ALCOVE j <br />48" o h <br />DUPLEX 0 ® 36" <br />RECEPTA L Tr f AFF <br />18" c - h <br />AFF <br />SPECIAL POWER OUTLET <br />\_ FINISHED FLOOR <br />BASIS OF DESIGN (PROVIDE EQUAL): MINTIE TECHNOLOGIES, INC. OR IC600MOBVC MOBILE ICRA PACKAGE ABATEMENT TECHNOLOGIES ECU <br />CEILING CAVITY ENVELOPE <br />-DURABLE FL STATE FIRE MARSHAL FLAME -RATED PVC SHEETING, HOSPITAL WHITE, EASY TO CLEAN WI STANDARD CLEANER <br />-ONE 20.5" DOOR <br />-TWO CLEAR PANEL WINDOWS -14.0" x 40.0" <br />NHD1-4 ENGRAVED PANEL & CIRCUIT -TWO NEGATIVE AIR PORTS <br />-11.0" ROUND PORT WITH DRAWSTRING AND SEAL <br />-3.5" ROUND HEPA VACUUM PORT WITH DRAWSTRING AND SEAL <br />-DOUBLE-REINFORCED FLOOR <br />COLORED COVERPLATE (BY BRANCH) -CLEAR POUCH TO DISPLAY WORK/INFECTION CONTROL PERMIT, WEIGHT 15 POUNDS <br />RED: CRITICAL, LIFE SAFETY, EQUIPMENT REQUIRED FOR ALL"ABOVE CEILING" WORK IN CORRIDOR SYSTEM <br />LETTERING IS WHITE SET UP PORTABLE DUST ENCLOSURE AT EACH CONSTRUCTION AREA INCORPORATE NEGATIVE AIR MACHINE AND PRESSURE MONITOR <br />(TYPICAL). MAINTAIN A 0.03" NEGATIVE PRESSURE IN THE ENCLOSURE RELATIVE TO THE ADJACENT SPACE. ALL EXISTING REGISTERS WITHIN <br />IVORY: NORMAL BRANCH ENCLOSURE AREA SHALL BE PROVIDED WITH CONSTRUCTION FILTERS. <br />LETTERING IS BLACK <br />FAN CRITERIA: <br />MANUFACTURER - HEPA-AIRE, MODEL - PREDATOR 1200 PAS <br />TYPICAL RECEPTACLE VARIABLE CFM -150 TO 900 CFM <br />ELECTRICAL:115 VOLTS, 3.5 FLA <br />PROVIDE AN INCLINED MANOMETER, DIFFERENTIAL PRESSURE TYPE, WITH WHITE FACE GAUGE AND BLACK LETTERS WITH MAXIMUM PRESSURE <br />RANGE OF 0.1" W.G. THIS SHALL BE USED BY THE CONTRACTOR TO RECORD, ON A DAILY BASIS, THE NEGATIVE PRESSURE IN THE RENOVATION <br />AREA RELATIVE TO THE ADJACENT SPACES. <br />CLOSE DAMPERS AND TAPE CLOSED ALL RETURN GRILLES SERVING AREAS WITHIN CONSTRUCTION AREA, ISOLATING THE RENOVATION AREA <br />FROM THE AIR HANDLER SYSTEM. ALL EXISTING EXHAUST REGISTERS LOCATED WITHIN THE RENOVATION AREA SHALL BE PROVIDED WITH <br />TEMPORARY CONSTRUCTIONS FILTERS. UPON COMPLETION OF CONSTRUCTION, OPEN GRILLES AND RE -BALANCE TO ORIGINAL AIRFLOW. <br />COVERPLATES & NAMEPLATES 4 1 PORTABLE DUST ENCLOSURE 2 <br />No Scale No Scale <br />0 <br />to <br />E <br />07NCLO" <br />8' <br />45 O <br />C3 <br />O <br />=mac <br />QLLr.- <br />0 <br />cm <br />c0z <br />=c� <br />Oma LL <br />z <br />N <br />�O <br />L <br />N <br />W <br />Z <br />V <br />IW W <br />W = <br />Zu <br />�a <br />Z� <br />W <br />rA <br />r__11 <br />rA <br />O <br />r�l <br />O <br />N <br />M-a <br />� <br />� <br />N <br />0 <br />O <br />0 <br />0 <br />•� <br />0 <br />O <br />0 <br />rr� <br />H <br />H <br />W <br />s� <br />r <br />J <br />eA <br />~ <br />L1J <br />-) <br />J <br />LLI <br />I- <br />z <br />c� <br />W <br />3 <br />U <br />w <br />�aa <br />x <br />9 <br />U_ <br />CK <br />SEAL <br />Christopher V. O'Hara, P.E. <br />Florida License #66504 <br />�0$.0111111 OP H ER�,,�, <br />E � <br />`��',�?�•' �` c NSF ;y-9,A <br />V: No 66504 •'� <br />STATE OF <br />c4 O R SOP. <br />SHEET nnE: <br />GENERAL INFO, LEGENDS & <br />SHEET INDEX - ELECTRICAL <br />DATE: 10/25/17 <br />SCALE: AS SHOWN <br />SHEET NO.: <br />E0,1 <br />