<br />ELECTRICAL SYMBOL LEGEND
<br />BASIC MATERIALS
<br />BASIC MATERIALS CONT.
<br />TELEPHONE/COMPUTER RACEWAY SYSTEM
<br />SYMBOL DESCRIPTION
<br />SYMBOL DESCRIPTION
<br />SYMBOL DESCRIPTION
<br />Sa SINGLE POLE SWITCH
<br />- 0 CONDUIT TURNING UP
<br />UP
<br />X = MOUNTING (F)LUSH, (S)URFACE, (M)ODULAR
<br />FURNITURE ADAPTOR (P)OLE, F(L)OOR, & (R)ACEWAY
<br />(SUBSCRIPT INDICATES ITEM CONTROLLED)
<br />-*DN CONDUIT TURNING DOWN
<br />-N = # OF VOICE JACKS
<br />S3 THREE-WAY SWITCH
<br />N = # OF DATA JACKS
<br />CONDUIT STUB
<br />N = # OF FIBER PORTS
<br />S4 FOUR-WAY SWITCH
<br />N = # OF VIDEO PORTS
<br />-� CONDUIT CONTINUED
<br />SP SINGLE POLE SWITCH
<br />X N N N N COMMUNICATIONS "INFORMATION OUTLET" MTD. AT
<br />WITH PILOT LIGHT
<br />FLEXIBLE CONDUIT
<br />410 ROOM # - OUTLET # RECEPTACLE HEIGHT UNLESS OTHERWISE NOTED.
<br />RECEPTACLE
<br />C = ABOVE THE COUNTER REFER TO SPECIFICATIONS FOR MANUFACTURER'S
<br />DUPLEX
<br />- - - - - EXISTING TO BE REMOVED
<br />W = WALL MOUNTED PART NUMBER.
<br />e- TWIST LOCK RECEPTACLE
<br />EXISTING TO REMAIN
<br />T
<br />SURGE PROTECTION TYPE (TVSS)
<br />EXISTING AFFECTED BY THIS PROJECT
<br />DUPLEX RECEPTACLE WITH
<br />- - - - FUTURE
<br />EACH HALF ON SEPARATE CIRCUIT
<br />(BREAKER SHALL BE TWO POLE WITH COMMON TRIP)
<br />NEW
<br />DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER
<br />LIGHTING
<br />NURSE CALL SYSTEMS
<br />DUPLEX SAFETY RECEPTACLE MOUNT
<br />COVERPLATES WITH SPANNER HEAD SCREWS
<br />A FIXTURE DESIGNATION
<br />DUPLEX RECEPTACLE WITH TOP HALF SWITCHED
<br />LED / FLUORESCENT FIXTURE
<br />ENHANCED PATIENT STATION WITH
<br />INTEGRAL CODE BLUE AND STAFF ASSIST
<br />SIMPLEX RECEPTACLE (EWC DENOTES
<br />a �_ LOWER CASE LETTER INDICATES
<br />STAFF EMERGENCY STATION
<br />-�
<br />ELECTRIC WATER COOLER. COORDINATE WITH EWC
<br />EWC
<br />CONTROL CIRCUIT SWITCH LEG
<br />INSTALLER FOR MOUNTING HEIGHT)
<br />STAFF EMERGENCY ANNUNCIATOR
<br />CIRCUIT NUMBER
<br />GFI RECEPTACLE MOUNTED ABOVE COUNTER
<br />--® CODE BLUE EMERGENCY STATION
<br />TWO DUPLEX RECEPTACLES WITH COMMON COVER
<br />LED I FLUORESCENT FIXTURE DIAGONAL SHADING DENOTES
<br />©
<br />TO LIGHT FIXTURE CONNECTED TO CRITICAL BRANCH.
<br />CORRIDOR DOME LIGHT CEILING MOUNTED
<br />TWO DUPLEX RECEPTACLES WITH COMMON COVER
<br />HID OR LED I FLUORESCEN FIXTURE
<br />O CORRIDOR ZONE LIGHT
<br />MOUNTED ABOVE COUNTER
<br />EXIT LIGHT FIXTURE
<br />ISOLATED GROUND DUPLEX RECEPTACLE,
<br />® DIRECTION ARROWS AS SHOWN
<br />IG (ORANGE DEVICE)
<br />(SHADED QUADRANT INDICATES FACE(S) OF FIXTURE)
<br />DUPLEX RECEPTACLE
<br />NOTE:
<br />TICK MARKS SHOWN ON ANY DEVICE REPRESENTS
<br />RECEPTACLE CONNECTED TO THE EMERGENCY CIRCUIT
<br />GENERAL DEMOLITION NOTES
<br />GENERAL NOTES
<br />(RED DEVICE) TYPICAL FOR ANY DEVICE IN LEGEND
<br />LIGHT SWITCHES SHALL BE MOUNTED 48 INCHES ABOVE FINISHED FLOOR TO CENTER LINE OF
<br />® SPECIAL PURPOSE RECEPTACLE, RATING AS NOTED
<br />1. DEVICE, UNLESS OTHERWISE NOTED.
<br />® GROUND BAR
<br />1. ALL DEVICES SHOWN ON DEMOLITION PLANS ARE EXISTING. REFER TO SYMBOL
<br />LEGEND FOR DEVICE DESCRIPTION.
<br />RECEPTACLES SHALL BE LOCATED 18 INCHES ABOVE FINISHED FLOOR TO CENTER LINE OF
<br />® CABLE TRAY
<br />2. DEVICE, UNLESS OTHERWISE NOTED. ABOVE COUNTER RECEPTACLES SHALL BE MOUNTED 6"
<br />2. EXISTING CONDITIONS SHOWN ON THIS DRAWING ARE TAKEN FROM ORIGINAL
<br />ABOVE BACK SPLASH TO CENTERLINE OF DEVICE.
<br />JUNCTION BOX
<br />DRAWINGS AND FIELD INVESTIGATION. ALL EXISTING CONDITIONS MUST BE
<br />VERIFIED PRIOR TO BID. FIELD CONDITIONS SHALL GOVEN.
<br />3. THE EQUIPMENT GROUNDING TERMINAL BARS OF THE NORMAL AND ESSENTIAL ELECTRICAL
<br />O CONDUIT SEAL -OFF FITTINGS
<br />3. THE DEMOLITION PLAN IS NOT INCLUSIVE OF ALL ELECTRICAL DEVICES WITHIN THE
<br />SYSTEM PANELBOARDS SERVING THE SAME PATIENT VICINITY SHALL BE BONDED TOGETHER WITH
<br />AN INSULATED, CONTINUOUS, COPPER CONDUCTOR NOT SMALLER THAN NUMBER 10.
<br />PROJECT AREA. IT IS INTENDED TO PROVIDE THE CONTRACTOR WITH A GENERAL
<br />®C3 SURGE SUPRESSOR
<br />KNOWLEDGE OF THE EXISTING CONDITIONS WITHIN THE PROJECT AREA. ANY
<br />4. EQUIPMENT SHALL BE OF MATERIALS SUITABLE FOR AND RATED FOR THE ENVIRONMENT IN WHICH
<br />C3 = SERVICE ENTRANCE DEVICE
<br />DISCREPANCIES OR CONDITIONS NOT SHOWN ON THIS PLAN SHALL BE BROUGHT
<br />THEY ARE TO BE INSTALLED.
<br />B3 = DISTRIBUTION BOARD DEVICE
<br />TO THE ATTENTION OF THE ENGINEER. THE CONTRACTOR IS RESPONSIBLE FOR ALL
<br />A3 = PANELBOARD DEVICE
<br />REQUIRED DEMOLITION WHETHER SHOWN ON THE PLANS OR NOT.
<br />5. A. WORKING CLEARANCES FOR ELECTRICAL EQUIPMENT SHALL BE IN COMPLIANCE WITH NEC
<br />110.
<br />SHUNT -TRIP BUTTON - FLUSH MOUNTED UNLESS
<br />4. ALL CONDUITS SERVING OTHER SPACES OR FLOORS, THAT RUN THROUGH THE
<br />® OTHERWISE NOTED NEMA 311 FOR EXTERIOR LOCATIONS
<br />PROJECT AREA SHALL REMAIN ACTIVE DURING CONSTRUCTION, SO AS NOT TO
<br />B. THE EXCLUSIVELY DEDICATED SPACE EXTENDING FROM FLOOR TO STRUCTURAL CEILING WITH
<br />CAUSE ANY DISRUPTION TO THESE OTHER SPACES. IT IS THE CONTRACTOR'S
<br />A WIDTH AND DEPTH OF THE PANELBOARD OR SWITCHBOARD MUST BE CLEAR OF ALL PIPING,
<br />RESPONSIBILITY TO INSURE THAT ALL CONDUITS, NEW OR EXISTING, WITHIN THE
<br />DUCTS, EQUIPMENT FOREIGN TO THE ELECTRICALEQUIPMENT OR ARCHITECTURAL
<br />© POWER CONNECTION TO EQUIPMENT
<br />PROJECT AREA ARE PROPERLY SUPPORTED AND PROVIDED WITH BONDING
<br />6, APPURTENANCES IN ACCORDANCE WITH NEC 408.
<br />BUSHING IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE.
<br />MAGNETIC MOTOR STARTER OR CONTACTOR
<br />CRITICAL AND LIFE SAFETY LIGHT SWITCHES SHALL BE ROUTED IN CONDUIT AND BOXES OTHER
<br />® SIZE AS NOTED
<br />5. ALL ITEMS REMOVED UNDER THIS PROJECT SHALL BE DISPOSED OR TURNED OVER
<br />7. THAN THAT FOR THE NORMAL BRANCH. ESSENTIAL SYSTEM SWITCHES SHALL BE RED IN COLOR.
<br />TO THE OWNER AT THE OWNER'S DISCRETION.
<br />EDH-X
<br />ELECTRIC DUCT HEATER
<br />8. PATIENT CARE AREAS SHALL BE PROVIDED WITH GROUNDING IN ACCORDANCE WITH NEC 517.
<br />�M/�
<br />6. THIS CONTRACTOR SHALL PROVIDE ELECTRICAL FOR PHASING WORK AS REQUIRED
<br />OR DIRECTED BY THE ARCHITECT, REFER TO ARCHITECURAL PHASING PLAN.
<br />WHEN ELECTRICAL BOXES ARE LOCATED IN VERTICAL FIRE -RESISTIVE ASSEMBLIES, (CLASSIFIED
<br />MOTOR CONNECTION, NUMBER DENOTES HORSEPOWER
<br />TEMPORARY ELECTRICAL SERVICES (POWER,LIGHTING, NURSE CALL, FIRE ALARM,
<br />AS FIRE/SMOKE AND SMOKE PARTITIONS), THEY SHALL BE INSTALLED WITHOUT AFFECTING THE
<br />ETC) SHALL BE PROVIDED WHEN NEW WORK AFFECTS SERVICES NEEDING TO
<br />FIRE CLASSIFICATION. ALL OF THE FOLLOWING CONDITIONS SHALL BE MET:
<br />®F VARIABLE FREQUENCY DRIVE
<br />REMAIN ACTIVE. IF FIRE ALARM SYSTEM CANNOT BE MAINTAINED IN THE
<br />CONSTRUCITON AREA, A FIRE WATCH SHALL BE PROVIDED.
<br />A. ALL ELECTRICAL BOXES SHALL BE METALLIC.
<br />® DIRECT DIGITAL CONTROL PANEL
<br />7, UNLESS OTHERWISE NOTED, ALL EQUIPMENT, WIRING DEVICES, LIGHT FIXTURES,
<br />B. BOX OPENING SHALL OCCUR ONLY ON ONE SIDE OF FRAMING SPACE.
<br />CONDUIT AND WIRE IN THE PROJECT AREA SHALL BE REMOVED. THE CONTRACTOR
<br />TRANSFORMER
<br />SHALL INVESTIGATE THE PROJECT AREA PRIOR TO BID TO DETERMINE ALL
<br />C. BOX OPENING SHALL NOT EXCEED 16 SQUARE INCHES.
<br />REQUIRED DEMOLITION.
<br />D. ALL CLEARANCES BETWEEN OUTLET BOX AND GYPSUM BOARD SHALL BE COMPLETELY
<br />® AUTOMATIC TRANSFER SWITCH
<br />B. CONTRACTOR SHALL PROVIDE MEANS OF AUTOMATIC SMOKE DETECTION VIA
<br />FILLED WITH JOINT COMPOUND (OR OTHER APPROVED MATERIAL).
<br />IL
<br />INSTALLED SMOKE DETECTORS CONNECTED TO THE FACITLITY FIRE ALARMS
<br />SYSTEM FOR COVERAGE DURING NON -OCCUPIED PERIODS WITHIN THE
<br />E. PROVIDE A WALL AROUND OUTLETS LARGER THAN 16 SQUARE INCHES. THE INTEGRITY OF
<br />LEI30AR NON -FUSED DISCONNECT SWITCH, SIZE AS NOTED
<br />CONSTRUCTION AREA, IF DESIRED, A DOCUMENTED FIRE WATCH OF THE ENTIRE
<br />THE WALL RATING SHALL BE MAINTAINED.
<br />NF NF DENOTES NON -FUSED
<br />AREA PERFORMED IN INCREMENTS NO GREATER THAN ONE HOUR MAY BE
<br />I JC1 'OAR
<br />PERFORED PROVIDED THAT IT IS DOCUMENTED IN FULL ACCORDANCE WITH NPFA
<br />F. THE TOTAL AGGREGATE SURFACE AREA OF THE BOXES SHALL NOT EXCEED 100 SQUARE
<br />FUSED DISCONNECT
<br />72. COORDINATE ACTIVITY IN FIELD WITH GENERAL CONTRACTOR.
<br />INCHES PER 100 SQUARE FEET.
<br />t[S] 20AF
<br />AR DENOTES AMP RATING OF SWITCH
<br />9. "ETR" DENOTES EXISTING ELECTRICAL DEVICE TO REMAIN.
<br />G. OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE RESISTIVE ASSEMBLIES SHALL BE
<br />MCP AF DENOTES AMP FUSE SIZE
<br />SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 24 INCHES.
<br />SIZE /�# OF POLES
<br />`3013
<br />H. OUTLET BOXES SHALL BE SECURELY FASTENED TO WALL FRAMING MEMBERS.
<br />UVI COMBINATION MAGNETIC MOTOR STARTER,
<br />3R
<br />FACING SHALL BE CUT NOT TO EXCEED 118 INCH
<br />0 SIZE AS NOTED, 3 POLE UNLESS OTHERWISE NOTED
<br />I. THE OPENING IN THE GYPSUM BOARD
<br />9. BETWEEN THE EDGES OF THE OUTLET BOX AND THE EDGES OF THE OPENING.
<br />ENCLOSURE NEMA 1 UNLESS NOTED
<br />NON-METALLIC RACEWAYS SHALL NOT BE USED TO SERVE ANY PATIENT CARE SPACE. ALL
<br />NEMA STARTER SIZE
<br />RADIOLOGY NOTES
<br />10. WIRING SHALL BE MECHANICALLY PROTECTED BY INSTALLATION IN METALLIC RACEWAYS.
<br />^ BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS,
<br />11. ALL DEVICES SHALL BE MOUNTED VERTICAL, UNLESS OTHERWISE NOTED.
<br />CONTRACTOR SHALL REFER TO THE RADIOLOGY VENDOR DRAWINGS FOR ALL REQUIRED
<br />SURFACE MOUNTED
<br />ELECTRICAL WORK IN THOSE AREAS, THE VENDOR DRAWINGS IN CONJUCTION WITH THESE
<br />12. ALL RECEPTACLES SHALL BE MOUNTED SUCH THAT THE GROUND PIN IS MOUNTED UP.
<br />DOCUMENTS SAHLL BE THE BASIS OF BID. All IDENTIFICATIONS INTHEVENDOR DRAWINGS
<br />BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS,
<br />OF TUSTOMERICONTRACTOR" SHALL BE THE RESPONSIBILITY OF THE "CONTRACTOR". IT IS
<br />13. THE NUMBER OF ARROWHEADS ON THE HOMERUNS DENOTES THE NUMBER OF CIRCUITS.
<br />FLUSH MOUNTED
<br />THE INTENTION OF THE VENDOR DRAWINGS THAT ALL WORK (LABOR, MATERIALS, ETC.) REQUIRED
<br />FOR A COMPLETE AND OPERATIONAL SYSTEM SHALL BE PROVIDED.
<br />ALL NEW AND EXISTING PANELS AFFECTED BYTHIS PROJECT SHALL BE PROVIDED WITH A NEW
<br />BRANCH CIRCUIT PANELBOARD, OVER 250 VOLTS,
<br />TYPE WRITTEN DIRECTORY.
<br />SURFACE MOUNTED
<br />THESE PLANS ARE INTENDED TO GIVE THE CONTRACTOR A GENERGAL KNOWLEDGE OF THE WORK ASSOCIATED WITH
<br />THE INTALLATION OF EQUIPMMENT IN THE SELECTED S, IT IS NOT INTENDED TO INDICATE ALL
<br />BRANCH CIRCUIT PANELBOARD, OVER 250 VOLTS,
<br />-�
<br />C,O OR DIMENSIONS ORLOCATIONS OFEQUOLOGY
<br />CONNECTIONS, BOX SE ETC, PMENT. ALL EQUIPMENT SHALL E
<br />CODES
<br />FLUSH MOUNTED
<br />INSTALLED PER THE OWNER APPROVED MANUFACTURER'S INSTALLATION DRAWINGS. INSTALLATION SHALL BE
<br />COORDINATED IN FIELD WITH RADIOLOGY EQUIPMENT MANUFACTURER. EQUIPMENT MANUFACUTER SHALL SUPLLY
<br />1. LIFE SAFETY CODE - NFPA 101(2012).
<br />BRANCH CIRCUIT CONDUIT CONCEALED ABOVE
<br />FIXED LENGTH CABLES, WHEREBY ALL MEASUREMENTS SHALL BE DETERMINED FROM ELECTRICAL THROUGH RUNS
<br />CEILING OR IN WALL. CONDUIT SHALL INCLUDE
<br />INDICATED ON VENDOR DRAWINGS, ANY CHANGES TO EQUIPMENT PLACEMENT OR TROUGH ROUTINGS AT JOB SITE WILL
<br />2. NATIONAL ELECTRICAL CODE - NFPA 70 (2011).
<br />CAUSE THE DELIVERY OF INACCURATE AND ERRONEOUS CABLEE LENGTHS. THIS MAY RESULT IN ADDITOINAL COST FOR
<br />3. NATIONAL FIRE PROTECTION ASSOCIATION 72 (2010); NATIONAL FIRE ALARM & SIGNALING CODE.
<br />PHASE, NEUTRAL AND GROUND CONDUCTORS
<br />REPLACEMENT CABLES AND DELAY EQUIPMENT INSTALLATION. COORDINATE PLACEMENT OF ALL EQUIPMENT WITH
<br />4. NATIONAL FIRE PROTECTION ASSOCIATION 99 (2012). HEALTH CARE FACILITIES
<br />AS REQUIRED FOR CIRCUITS (UNLESS OTHERWISE NOTED).
<br />EQUIPMENT INSTALLER PRIOR TO ROUGH -IN. THE FOLLOWING MUST BE PERFOREDIPROVIDED AS REQUIRED:
<br />5. BUILDING CODE: FLORIDA BUILDING CODE (2014 5TH EDITION).
<br />6. FGI - GUIDELINES FOR DESIGN & CONSTRUCTION OF THE HEALTH CARE FACILITIES. (2010)
<br />BRANCH CIRCUIT CONDUIT CONCEALED IN SLAB,
<br />A. REDUNDANT GROUNDING FOR THE PATIENT CARE AREA VIA THE RACEWAY SYSTEM. THE
<br />7. NFPA 90A, 2012 EDITION, STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING & VENTILATING SYSTEMS.
<br />UNDERGROUND OR UNDER FLOOR.
<br />EQUIPMENT MUST BE FASTENED TO THE RACEWAY SYSTEM OR BE BONDED TO THE RACEWAY SYSTEM BY THE USE
<br />ELECTRICAL DRAWING INDEX
<br />�r _\ BRANCH CIRCUIT CONDUIT EXPOSED
<br />OF FLEXIBLE METAL CONDUIT OR BONDING STRAPS.
<br />B, SEPERATE RACEWAYS OR CONTINUOUS BARRIERS FOR THE SEPERATION OF INTERCONNECTING CABLES PER
<br />SHEET
<br />DESCRIPTION
<br />ISSUED
<br />CIF- GROUND OR GROUND ROD AS NOTED
<br />VOLTAGE RATING AND CLASS. POWER AND CLASS 1 CIRCUIT WIRING SHALL BE ROUTED TOTALLY SEPERATE FROM
<br />CLASS 2 AND CLASS 3 CIRCUIT WIRING. PROVIDE A CHART AND/OR WIRING DIAGRAM WITH MARKED CABLES TO
<br />EO.1
<br />GENERAL INFO, LEGENDS & SHEET INDEX - ELECTRICAL
<br />Yes
<br />FACILITATE VERIFICATION OF THIS REQUIREMENT. THIS CHART MUST BE DEVELOPED BY THE EQUIPMENT
<br />EO.2
<br />ELECTRICAL ONE -LINE DIAGRAM
<br />Yes
<br />CRITICAL BRANCH CONDUIT
<br />MANUFACTURER'S ENGINEERING DEPARTMENT.
<br />E1.0
<br />OVERALL FIRST FLOOR PLAN - ELECTRICAL
<br />Yes
<br />L `\
<br />E1.1
<br />ENLARGED CT ROOM PLAN - FIRST FLOOR - ELECTRICAL
<br />Yes
<br />r- LIFE SAFETY BRANCH CONDUIT
<br />C. RACEWAY SHALL NOT BE EXPOSED, PROVIDE FLUSH MOUNTED WIREWAY AND CONCEALED CONDUIT. CIRCUIT
<br />BREAKERS, PANELBOARDS AND EPO STATIONS SHALL BE FLUSH MOUNTED.
<br />E2.1
<br />IE3.1
<br />PANEL SCHEDULES
<br />Yes
<br />EQUIPMENT BRANCH CONDUIT
<br />ELECTRICAL SPECIFICATIONS
<br />Yes
<br />NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT.
<br />CADDY
<br />FINISHED CEILING
<br />VOICE CABLE
<br />DATA CABLE
<br />CENTERED BETWEEN
<br />DOOR & CEILING
<br />WALL MOUNTED LIGHT FIXTURES (COORDINATE WITH
<br />ARCHITECT)
<br />AS NOTED ON PLANS hL EXIT
<br />ARCHITECT)
<br />CENTERED OVER DOOI
<br />--- PANELBOARD (WHERE APPLICABLE)
<br />,FIRE HORN
<br />(OR
<br />CHIME) &
<br />LIGHT 80"
<br />AFF FROM
<br />BOTTOM
<br />OF DEVICE
<br />1" CONDUIT -J DUPLEX 90" FA PULL
<br />STUB CONDUIT IN WALL. RECEPTACLE
<br />ABOVE
<br />CEILING.
<br />°o h
<br />78" MAX.
<br />TO TOP DEVICE 4,4"
<br />AFF
<br />SINGLE GANG BOX
<br />WITH
<br />OUTLET PLATE
<br />AND
<br />JACKS
<br />n n REVIEW EACH
<br />n n LOCATION FOR
<br />HEIGHT
<br />n n REQUIREMENT.
<br />TYPICAL VOICE / DATA OUTLET
<br />No Scale
<br />NHD1-4 1'----ENGRAVED PANEL & CIRCUIT
<br />COLORED COVERPLATE (BY BRANCH)
<br />RED: CRITICAL, LIFE SAFETY, EQUIPMENT
<br />LETTERING IS WHITE
<br />IVORY: NORMAL BRANCH
<br />LETTERING IS BLACK
<br />TYPICAL SWITCH
<br />3 1 MOUNTING HEIGHTS
<br />No Scale
<br />STATION
<br />h N 0
<br />DUPLEX
<br />O RECEPTACLE
<br />SWITCH LOCATED IN 1
<br />ALCOVE j
<br />48" o h
<br />DUPLEX 0 ® 36"
<br />RECEPTA L Tr f AFF
<br />18" c - h
<br />AFF
<br />SPECIAL POWER OUTLET
<br />\_ FINISHED FLOOR
<br />BASIS OF DESIGN (PROVIDE EQUAL): MINTIE TECHNOLOGIES, INC. OR IC600MOBVC MOBILE ICRA PACKAGE ABATEMENT TECHNOLOGIES ECU
<br />CEILING CAVITY ENVELOPE
<br />-DURABLE FL STATE FIRE MARSHAL FLAME -RATED PVC SHEETING, HOSPITAL WHITE, EASY TO CLEAN WI STANDARD CLEANER
<br />-ONE 20.5" DOOR
<br />-TWO CLEAR PANEL WINDOWS -14.0" x 40.0"
<br />NHD1-4 ENGRAVED PANEL & CIRCUIT -TWO NEGATIVE AIR PORTS
<br />-11.0" ROUND PORT WITH DRAWSTRING AND SEAL
<br />-3.5" ROUND HEPA VACUUM PORT WITH DRAWSTRING AND SEAL
<br />-DOUBLE-REINFORCED FLOOR
<br />COLORED COVERPLATE (BY BRANCH) -CLEAR POUCH TO DISPLAY WORK/INFECTION CONTROL PERMIT, WEIGHT 15 POUNDS
<br />RED: CRITICAL, LIFE SAFETY, EQUIPMENT REQUIRED FOR ALL"ABOVE CEILING" WORK IN CORRIDOR SYSTEM
<br />LETTERING IS WHITE SET UP PORTABLE DUST ENCLOSURE AT EACH CONSTRUCTION AREA INCORPORATE NEGATIVE AIR MACHINE AND PRESSURE MONITOR
<br />(TYPICAL). MAINTAIN A 0.03" NEGATIVE PRESSURE IN THE ENCLOSURE RELATIVE TO THE ADJACENT SPACE. ALL EXISTING REGISTERS WITHIN
<br />IVORY: NORMAL BRANCH ENCLOSURE AREA SHALL BE PROVIDED WITH CONSTRUCTION FILTERS.
<br />LETTERING IS BLACK
<br />FAN CRITERIA:
<br />MANUFACTURER - HEPA-AIRE, MODEL - PREDATOR 1200 PAS
<br />TYPICAL RECEPTACLE VARIABLE CFM -150 TO 900 CFM
<br />ELECTRICAL:115 VOLTS, 3.5 FLA
<br />PROVIDE AN INCLINED MANOMETER, DIFFERENTIAL PRESSURE TYPE, WITH WHITE FACE GAUGE AND BLACK LETTERS WITH MAXIMUM PRESSURE
<br />RANGE OF 0.1" W.G. THIS SHALL BE USED BY THE CONTRACTOR TO RECORD, ON A DAILY BASIS, THE NEGATIVE PRESSURE IN THE RENOVATION
<br />AREA RELATIVE TO THE ADJACENT SPACES.
<br />CLOSE DAMPERS AND TAPE CLOSED ALL RETURN GRILLES SERVING AREAS WITHIN CONSTRUCTION AREA, ISOLATING THE RENOVATION AREA
<br />FROM THE AIR HANDLER SYSTEM. ALL EXISTING EXHAUST REGISTERS LOCATED WITHIN THE RENOVATION AREA SHALL BE PROVIDED WITH
<br />TEMPORARY CONSTRUCTIONS FILTERS. UPON COMPLETION OF CONSTRUCTION, OPEN GRILLES AND RE -BALANCE TO ORIGINAL AIRFLOW.
<br />COVERPLATES & NAMEPLATES 4 1 PORTABLE DUST ENCLOSURE 2
<br />No Scale No Scale
<br />0
<br />to
<br />E
<br />07NCLO"
<br />8'
<br />45 O
<br />C3
<br />O
<br />=mac
<br />QLLr.-
<br />0
<br />cm
<br />c0z
<br />=c�
<br />Oma LL
<br />z
<br />N
<br />�O
<br />L
<br />N
<br />W
<br />Z
<br />V
<br />IW W
<br />W =
<br />Zu
<br />�a
<br />Z�
<br />W
<br />rA
<br />r__11
<br />rA
<br />O
<br />r�l
<br />O
<br />N
<br />M-a
<br />�
<br />�
<br />N
<br />0
<br />O
<br />0
<br />0
<br />•�
<br />0
<br />O
<br />0
<br />rr�
<br />H
<br />H
<br />W
<br />s�
<br />r
<br />J
<br />eA
<br />~
<br />L1J
<br />-)
<br />J
<br />LLI
<br />I-
<br />z
<br />c�
<br />W
<br />3
<br />U
<br />w
<br />�aa
<br />x
<br />9
<br />U_
<br />CK
<br />SEAL
<br />Christopher V. O'Hara, P.E.
<br />Florida License #66504
<br />�0$.0111111 OP H ER�,,�,
<br />E �
<br />`��',�?�•' �` c NSF ;y-9,A
<br />V: No 66504 •'�
<br />STATE OF
<br />c4 O R SOP.
<br />SHEET nnE:
<br />GENERAL INFO, LEGENDS &
<br />SHEET INDEX - ELECTRICAL
<br />DATE: 10/25/17
<br />SCALE: AS SHOWN
<br />SHEET NO.:
<br />E0,1