My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7880-7898 Gall Blvd
Zephyrhills
>
Building Department
>
Building Plans
>
7880-7898 Gall Blvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 4:19:27 PM
Creation date
2/18/2025 3:52:55 PM
Metadata
Fields
Template:
Building Plans
Street #
7880-7898
Location
Gall Blvd
Contractor
DesignTech International
Building Plans - Permit #
14509-14513
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11 i 1 I II I'I11M III 11 <br />1I-L- I--p=�111 w i I - <br />1/2" o ALL THREADED <br />HANGER ROD <br />LOCKING NUT -� <br />SUPPORT NUT <br />HEAVY DUTY <br />CLEVIS HANGER <br />INSULATION WITH <br />VAPOR BARRIER <br />PIPING <br />18 GA. GALV'D <br />STEEL SADDLE <br />3 TIMES PIPE DIA. <br />OR 9" MIN LENGTH <br />PIPE HANGER DETAIL <br />SCALE: NONE <br />WATER HAMMER ARRESTOR <br />EQUAL TO PRECISION PLUMBING <br />PRODUCTS MODEL WITH <br />(SWE <br />BRAT <br />MAIN <br />PPP SIZING CHART <br />FIXTURE <br />UNITS <br />SIZE <br />(SWEAT) <br />PART <br />NUMBER <br />1-11 <br />1/2" <br />SWA-500 <br />12-32 <br />3/4" <br />SWA-750 <br />33-60 <br />1" <br />SWA-1000 <br />61-113 <br />11/ " <br />SWA-1250 <br />114-154 <br />11/2" <br />SWA-1500 <br />155-330 <br />2" <br />SWA-2000 <br />DROP TO PLUMBING <br />FIXTURES <br />NOTES: <br />1. PROVIDE A WATER HAMMER ARRESTOR ON EACH <br />HOT WATER AND COLD WATER DROP. <br />2. ARRESTORS SHOULD ALWAYS BE INSTALLED SO <br />THAT THERE IS AN UNOBSTRUCTED SHOCK PATH <br />TO THE ARRESTOR. <br />3. ARRESTORS SHOULD ALWAYS BE PLACED AS NEAR <br />TO THE SOURCE OF SHOCK AS POSSIBLE. <br />WATER HAMMER ARRESTOR DETAIL <br />SCALE: NONE <br />U <br />a <br />0 <br />0 <br />2 <br />X <br />la <br />�o <br />Y <br />N <br />i <br />.; <br />co <br />0 <br />co <br />J <br />�o <br />_M <br />O <br />C4 <br />N <br />3 <br />a <br />0 <br />N" <br />a_ <br />co <br />ti <br />LO <br />0 <br />0 <br />U <br />U_ <br />U) <br />U) <br />N <br />es <br />M <br />Lo <br />CD <br />CAST IRON CLEANOUT <br />WITH COVER FOR DUTY <br />AS REQUIRED <br />PVC SCH. 40 EXTENSION <br />(SAME SIZE AS SEWER UP <br />TO 6" DIA.) <br />6" THICK 24x24 <br />CONC, PAD. <br />GRADE OR PAVING <br />INVERT ELEVATIONS <br />SUBJECT TO FIELD <br />VERIFICATION <br />PVC SCH 40 LONG <br />SWEEP 1/4 BEND <br />OR COMB. "Y" & <br />1/8 BEND. (USE <br />REDUCING TYPE <br />WHERE REQUIRED). <br />--------------- <br />INVERT ELEVATIONS <br />SUBJECT TO FIELD <br />VERIFICATION <br />SEWER MATERIAL <br />AS SPECIFIED. <br />CLEANOUT TO GRADE DETAIL <br />SCALE: NONE <br />WASTE OR VENT RISER <br />PIPING TO LAVATORY <br />FIRE -RETARDANT INSERT <br />FOR 1/2" COPPER PIPE <br />GALVANIZED BRACKET <br />W/OPENINGS ON 4" <br />AND 8" CENTERS <br />STAINLESS STEEL BAND <br />ATTACHED TO WASTE RISER <br />(EQUAL TO HOLDRITE #110) <br />WATER PIPING SUPPORTS <br />SCALE: NONE <br />THERMAL EXPANSION TANK: AMTROL <br />"THERM X TROL" ST- 5 <br />VACUUM BREAKER; <br />WATTS 288A <br />OR EQUAL <br />r <br />DIELECTRIC UNION (TYP) <br />PROVIDE DRAINPAN WITH 1" <br />NEOPRENE STAND-OFFS, <br />ROUTE 1" COPPER <br />DRAIN LINES TO <br />MOP SERVICE BASIN <br />SECURELY ANCHOR TO <br />WALL STUDS WITH A i <br />MINIMUM OF FOUR (4) <br />1/4"o STEEL FASTENERS. <br />J <br />(2) VERTICAL & (2) <br />DIAGONAL ANGLES <br />11/2"0/2"x'/8" ALL WELDED <br />STEEL ANGLE MOUNTING 30 <br />SHELF PRIMED & PAINTED <br />WHITE GLOSS ENAMEL. <br />GATE VALVE (TYP) <br />AT 5-0" A.F.F. <br />CHECK VALVE <br />AT 5'-0" A.F.F. <br />HEAT TRAP <br />ASME T&P RELIEF VALVE <br />DRAIN VALVE <br />SAFETY PAN; 24 <br />1 GAGE GALVANIZED <br />SHEET METAL, 1-1/2" <br />DEEP, SOLDERED <br />LIQUIDTIGHT <br />MOUNT BOTTOM OF SHELF <br />AT 6'-8" A.F.F. <br />3/4"HW i 1 <br />3/4 "CCWW A <br />I __'j <br />WATER HEATER DETAIL <br />SCALE: NONE <br />LAVATORY <br />J.R. SMITH <br />#2698 <br />DOWN IN WALL — <br />FLOOR DRAIN WITH <br />TRAP PRIMER <br />CONNECTION PER <br />SPECIFICATIONS. <br />FLOOR <br />1/2" CPVC <br />SAFEWASTE <br />TO TRAP— <br />TRAP PRIMER DETAIL <br />SCALE: NONE <br />PLUMBING FIXTURE SCHEDULE <br />ROUGH -IN <br />MARK <br />FIXTURE, MODEL #, DESCRIPTION <br />WASTE <br />VENT <br />CW <br />HW <br />WC-HC <br />WATER CLOSET, HANDICAPPED <br />"CADET" <br />2" <br />1/2" <br />--- <br />AMERICAN STANDARD #2467.016 <br />WHITE ELONGATED, PRESSURE ASSISTED 1.6 GALLON FLUSH, TANK TYPE <br />WATER CLOSET, OLSONITE #95 WHITE SEAT, CP STOP AND SUPPLY. <br />LAV-HC <br />LAVATORY, WALL HUNG, HANDICAPPED <br />"LUCERENE" <br />1-1/2" <br />2„ <br />1/2" <br />1/2" <br />AMERICAN STANDARD #0355.012 <br />WITH 17401.172H 6" GOOSENECK FAUCET AND 4" WRIST BLADE HANDLES, <br />1-1/2 CP P-TRAP, CP STOPS, SUPPLIES. <br />DF-HC <br />DRINKING FOUNTAIN, DUAL LEVEL, HANDICAPPED <br />1-1/2" <br />2" <br />1/2" <br />--- <br />ELKAY EDFP217C <br />NON-REFRIGERATED, NON -ELECTRIC DRINKING FOUNTAIN, 1-1/4" 20 GAUGE <br />CP P-TRAP LESS CO, STOP AND SUPPLY. MOUNT LOWER NOZZLE AT 30" <br />A.F.F. FOR ADA COMPLIANCE. <br />MSB <br />MOP SERVICE BASIN <br />3" <br />2" <br />3/4" <br />3/4" <br />FIAT MSB2424 <br />24"x24" MOLDED STONE MOP SERVICE BASIN WITH 830-AA FAUCET, 832-AA <br />HOSE BRACKET AND HANGER. <br />EWH-5 <br />ELECTRIC WATER HEATER <br />--- <br />--- <br />3/4" <br />3/4" <br />A.O. SMITH DEL-5 <br />FOAM INSULATED, GLASS -LINED 5 GALLON TANK, THREE (3) YEAR WARRANTY <br />WATER HEATER. 22" HIGH x 22" DIAMETER, 3.0 kW ® 208 VOLT, 1 PHASE <br />ELECTRIC HEATER. U.L. LISTED AND ASHRAE 90.1-2004 APPROVED. SET <br />TEMPERATURE AT 110'F. <br />WH <br />WALL HYDRANT <br />--- <br />--- <br />3/4" <br />--- <br />ZURN Z-1322-EZ (FREEZE PROOF) <br />WALL HYDRANT, NON -FREEZE WITH POLISHED NICKEL BRONZE BOX AND <br />LOCKING COVER. PROVIDE WITH 3/4" HOSE CONNECTION AND INTEGRAL <br />BACKFLOW PREVENTER. MOUNT AT 18" A.F.G. COORDINATE WITH ARCHITECT. <br />FD <br />FLOOR DRAIN <br />3" <br />2" <br />1/2" <br />ZURN Z415-613-P <br />6" FLOOR DRAIN WITH TRAP -PRIMER CONNECTION AND TYPE "B" STRAINER. <br />COTG <br />CLEANOUT TO GRADE <br />SEE <br />--- <br />--- <br />--- <br />ZURN Z1400-HD <br />PLAN <br />D.C.C.I. BODY ADJUSTABLE TO FINISHED GRADE WITH HEAVY DUTY TOP. <br />SET IN 24"x24 % 6" CONCRETE PAD. <br />FCO <br />FLOOR CLEANOUT <br />SEE <br />--- <br />--- <br />--- <br />ZURN Z1400 <br />PLAN <br />D.C.C.I. BODY ADJUSTABLE TO FINISHED FLOOR. <br />WATER DEMAND <br />SCHEDULE <br />CW <br />HW <br />TOTAL <br />QTY <br />TOTAL <br />ABBR. <br />FIXTURE <br />EACH <br />EACH <br />EACH <br />EACH <br />ALL <br />WC-HC <br />WATER CLOSET - TANK TYPE <br />5.0 <br />-- <br />5.0 <br />2 <br />10.0 <br />LAV-HC <br />LAVATORY <br />1.5 <br />-- <br />1.5 <br />2 <br />3.0 <br />DF-HC <br />DRINKING FOUNTAIN <br />0.5 <br />-- <br />0.5 <br />1 <br />0.5 <br />MSB <br />MOP SERVICE BASIN <br />3.0 <br />3.0 <br />4.0 <br />1 <br />4.0 <br />TOTAL WSFU <br />17.5 <br />TOTAL GPM 18.6 GPM <br />PIPE SIZE= <br />1" <br />Job Number: 65173 <br />R. ST <br />' • •N <br />0 81 6 <br />f - <br />�� ' STATE OF t/ <br />0% <br />DR XV <br />ie;s l p N A� E % % <br />Joseph R. Stolz, <br />P.E. No.58186 <br />Revisions: <br />Date Description <br />I4 <br />C7 <br />Z <br />W <br />cV M <br />d <br />�gg <br />O <br />H° <br />�x <br />W <br />F- U <br />Q <br />�W <br />Z <br />H� <br />Ua <br />U a <br />a <br />O <br />W <br />o W <br />W44 <br />`� 3 <br />N <br />W <br />sx <br />Q. <br />Z <br />I�•�-I <br />W <br />W <br />� <br />O <br />� <br />P. <br />t <br />m <br />o <br />� <br />O <br />H <br />P1 <br />� <br />0 <br />WO <br />F'y <br />� <br />W <br />� <br />O <br />o <br />h�hrr•1I <br />W <br />W <br />� <br />F-•1 <br />x <br />a <br />N <br />Job Number: <br />12049.01 <br />File name: <br />Issued Date: <br />07.17.13 <br />Drawn by: <br />DC/LO <br />Checked by: <br />JS <br />SHEET NAME <br />PLUMBING <br />SCHEDULES & <br />DETAILS <br />' Colwill Engineering <br />Consulting Engineers, Inc. SHEET NUMBER <br />Engineering Business No. 9021 <br />Tel: East 1-252damo Drive Tampa, Florida 33805 P-2,0 <br />Tel: 813-241-2525 Fax: 813-241-2424 <br />© 2013 ALL RIGHTS RESERVED <br />
The URL can be used to link to this page
Your browser does not support the video tag.