Laserfiche WebLink
U <br />Q <br />0 <br />Ln <br />0 <br />to <br />-0 <br />X <br />.0 <br />P <br />O <br />M <br />,n <br />c� <br />n <br />_o <br />o� <br />co <br />0 <br />N <br />Ny <br />ti <br />3' <br />0 <br />CL <br />M <br />(+ <br />0 <br />0 <br />Q <br />U <br />E <br />LL <br />C0 <br />Cl) <br />P <br />cII <br />M <br />r- <br />LO <br />lfl <br />WCO <br />■11111� <br />112 1/2 <br />'10 <br />C ��� ��� @ <br />LAV-HC o o (ED <br />1/2"CW 1/2"CW <br />1/2"HW ".HW <br />L DF-HC I � <br />FCO <br />FCO 1/21,CW 4" <br />00, 4" 4" <br />SEE MAIN PLAN ON THIS <br />SHEET FOR CONTINUATION <br />IN THIS AREA <br />3" <br />WH O <br />SEE MAIN PLAN ON THIS <br />SHEET FOR CONTINUATION <br />IN THIS AREA <br />O� ENLARGEC <br />SCALE: 1/4"=1 '-0 <br />O <br />1/2-HW <br />MSB <br />3/4' CW <br />3/4 "HW <br />EWH-5 <br />- 3/4' CW <br />3/4"HW <br />3/4"CW&HW DROP TO <br />(1) MSB <br />I� PLUMBING PLAN <br />uv SCALE: 1/8"=1'-0" <br />O <br />3"VTR <br />I <br />3"V <br />I �'I <br />L- <br />2"V., <br />.01 i 3„V <br />2"VI 1 I <br />12"V <br />1 2"V I I wco <br />2"v 2"V I 1 FD I I <br /><� ,�'-1 L J 2�, 4"-HC <br />3" <br />4„ I 4oe <br />�� LAV-HC <br />FD <br />1 <br />I 4„ <br />I FCO <br />I <br />I <br />2"V I <br />I <br />4,. <br />I <br />SANITARY RISER <br />SCALE: N.T.S. <br />KEYED NOTES: O <br />1. 4" SANITARY/GREASE PIPING BELOW SLAB. <br />EXTEND DRAIN LINE UP 12" ABOVE FINISH FLOOR <br />AND CAP FOR FUTURE, INVERT SHALL BE 4'-0" <br />B.F.F. (MINIMUM) <br />2. 11/2" DOMESTIC WATER LINE BELOW SLAB, EXTEND <br />UP ALONG WALL AND VALVE/CAP, ABOVE <br />CEILING, FOR FUTURE. <br />3, 2" DOMESTIC WATER LINE BELOW SLAB. EXTEND <br />UP ALONG WALL AND VALVE/CAP, ABOVE <br />CEILING, FOR FUTURE. <br />4. 11/2" DOMESTIC WATER LINE BELOW SLAB. VALVE <br />AND CAP 12" ABOVE FINISH FLOOR, <br />5. 4" SANITARY PIPING BELOW SLAB. INSTALL <br />FLOOR CLEAN -OUT, FOR FUTURE. <br />6. INSTALL SHUTOFF VALVE 5'-0" A.F.F, <br />PLUMBING <br />LEGEND <br />SANITARY SEWER (SAN) <br />VENT (V) <br />ts-------i <br />COLD WATER (CW) <br />S - <br />HOT WATER (HW) <br />5 - - <br />GAS LINE (G) <br />5 GAS -� <br />FLOOR CLEANOUT (FCO) <br />S + FCO <br />CLEANOUT TO GRADE (COTG) <br />COTG <br />PIPE DROP <br />5 - +- <br />PIPE RISE <br />S - <br />GATE VALVE <br />GAS COCK <br />S= <br />HOSE BIBB (HB) <br />5 1i HB <br />POINT OF CONNECTION <br />PLUMBING GENERAL NOTES <br />1. THE REQUIREMENTS OF THE GENERAL CONDITIONS AND SUPPLEMENTARY <br />GENERAL CONDITIONS SHALL APPLY TO ALL PLUMBING WORK. INSTALLATION <br />SHALL BE IN ACCORDANCE WITH THE 2010 FLORIDA BUILDING CODE, STATE <br />AND LOCAL CODES AND THE LATEST AMENDMENTS THERETO. <br />2. THE WORK COVERED BY THIS SECTION OF THESE SPECIFICATIONS <br />CONSISTS OF FURNISHING ALL LABOR, EQUIPMENT, MATERIALS AND <br />SERVICE NECESSARY FOR AND REASONABLY INCIDENTAL TO THE PROPER <br />COMPLETION OF ALL PLUMBING WORK SHOWN ON THE DRAWINGS AND <br />SPECIFIED. MATERIALS OR PRODUCTS SPECIFIED BY TRADE NAME, <br />MANUFACTURER'S NAME OR CATALOG NUMBER SHALL BE INTERPRETED AS <br />ESTABLISHING A STANDARD OF QUALITY AND DESIGN. SUBSTITUTIONS SHALL <br />NOT BE ALLOWED UNLESS THEY ARE SUBMITTED FOR REVIEW TO USE AND <br />APPROVED BY THE ARCHITECT. FIXTURES BY ELDER, KOHLER OR <br />AMERICAN-STANDARD ARE APPROVED EQUAL. <br />3. FURNISH SIX (6) COPIES OF SHOP DRAWINGS OF EQUIPMENT OR <br />FIXTURES FOR APPROVAL PRIOR TO PURCHASING. <br />4. PLUMBING CONTRACTOR SHALL COORDINATE WITH ARCHITECTURAL, CIVIL, <br />STRUCTURAL, ELECTRICAL, MECHANICAL AND ALL OTHER TRADES FOR PIPE <br />ROUTING AND EQUIPMENT PLACEMENT. AVOID INTERFERENCE WITH <br />ARCHITECTURAL FEATURES, BEAMS, FOOTINGS, WINDOWS, ETC. NOTIFY <br />ARCHITECT IMMEDIATELY OF ANY CONFLICTS. SLEEVES SHALL BE <br />INSTALLED WHERE PIPING PASSES THROUGH STRUCTURE. FLOOR - F=1, <br />T=1. <br />5. CONTRACTOR SHALL KEEP A RECORD OF THE LOCATIONS OF ALL <br />CONCEALED WORK AND UPON COMPLETION OF THE JOB, SHALL SUPPLY AS - <br />BUILT DRAWINGS SHOWING IN COLORED PENCIL ON BLACK LINE PRINTS ANY <br />DEVIATION FROM THE ORIGINAL DRAWINGS. THESE DRAWINGS SHALL <br />INDICATE DIMENSIONS OF BURIED UTILITY LINES FROM BUILDING WALLS. <br />6. ALL WORK SHALL BE GUARANTEED, BOTH MATERIAL AND INSTALLATION, FOR <br />A PERIOD OF ONE YEAR FROM ACCEPTANCE BY OWNER. <br />7. PROVIDE WALL CARRIERS FOR ALL WALL HUNG PLUMBING FIXTURES. ALL <br />WALL HUNG PLUMBING FIXTURES SHALL BE CAPABLE OF SUPPORTING A <br />250 POUND VERTICAL LOAD. <br />8. INSULATE P-TRAP AND SUPPLIES UNDER WALL HUNG HANDICAPPED LAVATORY <br />FOR ADA COMPLIANCE. <br />SANITARY, WASTE AND VENT PIPING <br />1. SANITARY, WASTE AND VENT PIPING SHALL BE SCHEDULE 40 PVC <br />(ASTM-2665) WITH APPROVED PVC SOLVENT WELDED FITTINGS. COMPLY <br />WITH FLORIDA BUILDING CODE. PVC PIPING SHALL NOT BE RUN IN RETURN <br />AIR PLENUM OR FIRE RATED ASSEMBLIES. <br />2. ALL SOIL AND WASTE PIPING, 2-1/2" AND SMALLER, SHALL BE SLOPED AT <br />1/4" PER FOOT. LARGER WASTE PIPING SHALL BE SLOPED AT 1/8" PER <br />FOOT. <br />3. ALL VENTS THROUGH ROOF SHALL BE A MINIMUM OF 10'-0" OR AS <br />REQUIRED BY CODE AWAY FROM FRESH AIR INTAKES. <br />4. ALL VENTS THROUGH ROOF SHALL BE PROVIDED WITH FOUR (4) POUND <br />SHEET LEAD FLASHING EXTENDING UPWARD AROUND THE PIPE AND TURNED <br />DOWN INSIDE THE PIPE. <br />5. EXPOSED WASTE DRAINS, IN TOILETS, SHALL BE CHROME PLATED BRASS <br />WITH MATCHING ESCUTCHEONS. <br />6. CLEANOUT SHALL BE PROVIDED AT THE BASE OF EACH WASTE OR SOIL <br />STACK AT 18" A.F.F. MINIMUM, PER LATEST EDITION OF PLUMBING CODE. <br />7. TEST SANITARY, WASTE AND VENT PIPING BY A 10' WATER COLUMN FOR <br />TWENTY-FOUR (24) HOURS OR AS REQUIRED BY THE BUILDING <br />DEPARTMENT. <br />WATER PIPING <br />1. BELOW GROUND WATER PIPING SHALL BE TYPE "K" COPPER WITH VINYL <br />SLEEVE FOR CORROSION PROTECTION WITH WROUGHT COPPER FITTINGS AND <br />95-5 SOLDERED JOINTS. <br />2. ABOVE GROUND WATER PIPING SHALL BE TYPE "L" COPPER WITH WROUGHT <br />COPPER FITTINGS AND 95-5 SOLDERED JOINTS, <br />3, THE SITE SUBCONTRACTOR SHALL PROVIDE THE BACKFLOW PREVENTOR AND THE <br />WATER METER. IF SITE IS METERED WITH A "MASTER METER" CONTRACTOR <br />SHALL INSTALL A SUB -METER. <br />4. A SERVICE VALVE SHALL BE PROVIDED ON THE DOMESTIC WATER RISER AT <br />5'-0" ABOVE FINISHED FLOOR, WHERE WATER ENTERS THE BUILDING. <br />5. PROVIDE EACH FIXTURE WITH STOPS AND SUPPLIES. EXPOSED STOPS <br />AND SUPPLY PIPING SHALL BE CHROME PLATED, WITH A CHROME PLATED <br />ESCUTCHEON PLATE. <br />6. INSULATE ALL HOT WATER PIPING WITH 1" THICK, 3-1/2 POUND <br />DENSITY, RIGID FIBERGLASS INSULATION. INSULATE FITTINGS, VALVES <br />AND ALL SIMILAR ITEMS. INSULATE WATER PIPE AND P-TRAP BELOW ALL <br />HANDICAPPED LAVATORIES. <br />7. PROVIDE WATER HAMMER PROTECTION (EQUAL TO PRECISION PLUMBING <br />PRODUCT "SWA" SERIES) AT EACH FIXTURE OR GROUP OF SIMILAR FIXTURES. <br />FIELD FABRICATED MODELS ARE NOT ACCEPTABLE. <br />8. PROVIDE VACUUM BREAKERS AS REQUIRED BY CODE. <br />9. PROVIDE TRAP PRIMERS FOR ALL FLOOR DRAINS AS REQUIRED BY CODE. <br />10. TEST ALL WATER PIPING AT 100 PSIG FOR TWENTY-FOUR (24) HOURS <br />OR AS REQUIRED BY CODE. <br />11. STERILIZE ALL WATER PIPING IN ACCORDANCE WITH HEALTH <br />DEPARTMENT REGULATIONS AND AMERICAN WATER WORKS SPECIFICATIONS. <br />12. SUPPORT ALL WATER PIPING WITH PIPE HANGERS BY GRINNELL OR <br />APPROVED EQUAL. <br />Job Number: 65I73 <br />'Colwill Engineering <br />Consulting Engineers, Inc. <br />Engineering Business No. 9021 <br />Tel: East 1-252damo Drive Tampa, Florida 33805 <br />Tel; 813-241-2525 Fax: 813-241-2424 <br />© 2013 ALL RIGHTS RESERVED <br />Revisions: <br />Date I'Description <br />O <br />L7 <br />O M <br />W <br />Wd <br />O <br />�x <br />U <br />U <br />a <br />w <br />0 <br />C>� <br />W <br />x <br />Q <br />Z <br />� <br />w <br />� <br />M <br />� <br />H <br />a <br />� <br />a <br />U <br />ti <br />�+ <br />0 <br />0 <br />W <br />x <br />x <br />N <br />Job Number: <br />12049.01 <br />File name: <br />Issued Date: <br />07.17.13 <br />Drawn by: <br />CR <br />Checked by: <br />JS <br />11 SHEET NAME I I <br />PLUMBING <br />PLAN <br />SHEET NUMBER <br />P-1'00 <br />