Laserfiche WebLink
PLOTTED: 3/24/2020 03:13 PM JOHN KRAMER <br />F <br />3 <br />0 <br />0 <br />U <br />C <br />0 <br />Rol <br />LL- <br />O <br />U <br />O <br />B <br />r- <br />co <br />N <br />w <br />0 <br />LAJ <br />a <br />ji <br />STORMWATER POLLUTION PREVENTION PLAN <br />THIS PLAN SHALL BE IN ACCORDANCE WITH THE FLORIDA EROSION AND SEDIMENT CONTROL MANUAL. <br />SITE DESCRIPTION AND GENERAL INFORMATION <br />PROJECT NAME AND LOCATION <br />WASTEWATER TREATMENT FACILITY, ADVANCE WATER TREATMENT UPGRADE, ZEPHYRHILLS FLORIDA. <br />OWNER NAME AND ADDRESS <br />CITY OF ZEPHYRHILLS <br />39825 ALSTON AVENUE <br />ZEPHYRHILLS, FLORIDA <br />PROJECT DESCRIPTION <br />THE <br />PROJECT <br />CONSISTS <br />OF <br />SEQUENCE <br />OF <br />MAJOR ACTIVITIES <br />THE ORDER OF MAJOR ACTIVITIES WILL BE AS FOLLOWS: <br />1. INSTALL SILT FENCE AS SHOWN ON PLANS. <br />2. STABILIZE CLEARED AREAS WITHIN 48 HOURS OF LAST DISTURBANCE. <br />3. COMPLETE GRADING AND INSTALL PERMANENT SODDING. <br />4. WHEN ALL CONSTRUCTION IS COMPLETE, STABILIZE (E.G. SOD, SEED/MULCH, ETC) ANY REMAINING <br />DISTURBED AREAS. <br />SUFFICIENT PRECAUTIONS SHALL BE TAKEN TO PREVENT POLLUTION OF STREAMS, CANALS, LAKES, <br />RESERVOIRS, WETLANDS, AND OTHER WATER IMPOUNDMENTS. ALSO, OPERATIONS SHALL BE CONDUCTED <br />AND SCHEDULED SO AS TO AVOID POLLUTION OR SILTATION OF STREAMS, WATER BODIES, ETC. <br />INSPECTIONS MUST OCCUR AT LEAST ONCE A WEEK AND WIiHN 24 HOURS OF THE 00 OF A STORK EVENT THAT IS 0.50 ACHES OR GREATER <br />INSPECTOR: FDEP WOES SIORYTNATER IDENTIFICATION NUMBER: FLR10 <br />LOCATION <br />RAIN DATA <br />TYPE OF CONTROL <br />(SEE eELOMI) <br />DATE INSTALLED / <br />MODIFIED <br />CURRENT CONOTiION <br />(SEE BT]-011r) <br />CORRECTIVE ACTION / OTTER REiARKS <br />DADA►, � « ••a� � � a• <br />1. SILT FENCE <br />10. STORY DRAIN NIET PROTECTION <br />19. REWORCED SOIL REUMNMIG SYSTEY <br />28. TREE PROTECTION <br />2. EARTH DIES <br />11. VEGETATIVE BUFFER STRIP <br />20. GABION <br />29. DETENTION POND <br />3. STRUCTURAL DIVISION <br />12. VEGETATIVE PRESERVATION AREA <br />21. SEDIAE NT BASIN <br />30. RETENTION POND <br />4. SWALE <br />II RETENTION POND <br />22. TEMPORARY SEED / SOD <br />31. WASTE DISPOSAL / HOUSEKEEPING <br />5. SEDWE NT TRAP <br />It CONSTRUCTION ENTRANCE STABILIZATION <br />23. PERMA *XT SEED / SOD <br />32. DAY <br />6. CHECK DAM <br />15. PERMETE R DITCH <br />24. MULCH <br />33. SAND BAG <br />8. PPE SLOPE DRAM <br />16. CURB AND GUTTER <br />25. HAY BALES <br />34. OTHER <br />9. LEVEL SPREADERS <br />17. PAVED ROAD SURFACE <br />26. GEOTEXTILE <br />9. LEVEL. SPREADERS <br />I& ROCK OUTLET PROlECT10N <br />27. RIP -RAP <br />INSPECTOR MNFORINTIOW <br />NAME QIWJFKXION DATE <br />THE ABOVE SM7URE ALSO SHALL CERTIFY THAT THIS FACILITY IS N COMPLIANCE WITH THE STORMMNTER POLLUTION PREVENTION PLAN NO THE STATE <br />OF FLIORM GEIMBC PERMIT FOR STORIM 70 DISCIORGE FROM LARGE NO SWILL CONSTRUCTION ACTIVITIES IF THERE ARE NOT MY INCIDENTS OF <br />DEI4M ABOVE. <br />s s s s s s <br />"I CERTIFY UNDER PEMLTY OF IN THAT THIS DOCLUDIT AND ALL ATTACHMMTS WERE PREPARED UNDER MY DRECTION OR SIIPEIMION N ACCORDANCE <br />WITH A SYS" DESIGNED 70 ASSURE THAT QUALIFIED PERSONNEL PROPERLY GATHERED AND EYM JATED THE INFORMATION SUBMITTED. BASED ON YY NOURY <br />OF THE PERSON OR PERSONS WHO MANAGE THE SYSTEK OR THOSE PERSONS ORECTLY RESPONSIBLE FOR GAD40 MNG THE MNFORd111TKK THE INFORMATION <br />SUBMITTED IS. TO THE BEST OF MY KNOWLEDGE AND 00EF. TRUE. ACCUPATT:. AND COMPLETE 1 AM AWARE THAT THERE ARE SO4FICNNT PEN&71ES FOR <br />SUBMITTING FALSE INFORMATION. INCLUDING THE POSSIBILITY OF FINE AND I PPo90NIlE NT FOR KNOWING VIOLATIONS." <br />NAME (RESPONSIBLE IIUTHIORBlt7 <br />DATE <br />De mcD AHOLMES <br />DRAWN JKRAMER <br />VTR. DATE REVOM BY APM C�EacED TFRIEDRICH <br />• � 1 a r <br />as � - . � . •.a <br />too •#. <br />•�I��I��I �I��I��I <br />lit v:1-7"12 <br />STANDARD DETAIL <br />TRENCH MATH NATIVE BACKFILL <br />9' MAX. <br />(RED) <br />STORAGE HT. <br />1 Y MIN. <br />ion mun <br />es <br />CERTIFICATE OF AUTHORIZATION *1841 <br />730 NE WALDO ROAD. GAINESVILLE. FLORIDA 32641 / (352) 377- 5821 <br />324 S HYDE PARK AVE, SUITE 250, TAMPA, FLORIDA 33606 / (813) 258- 0703 <br />PONDING HEIGHT <br />EXTRA STRENGTH FILTER FABRIC <br />NEEDED NTHOUT MARE MESH SUPPORT <br />i■■■■■■IM ■I■■■■■■■/" <br />■■■■m■■■■■■■■■■■IP' <br />mill ■■■■■■■■■■■■■■�� <br />mile■� <br />-NI/ I a « <br />/✓ <br />RUNOFF NOTES: <br />1. INSPECT AND REPAIR FENCE AFTER EACH <br />STORM EVENT AND REMOVE SEDIMENT MAVEN <br />NECESSARY. <br />2. REMOVED SEDIMENT SHALL BE DEPOSITED <br />INSTALLING A TO AN AREA THAT MALL NOT CONTRIBUTE <br />SEDIMENT OFF -SITE AND CAN BE <br />FILTER FABRIC SILT FENCE '�,,,CE STABILIZED- <br />3. LACED ON SLOPE <br />5< CITY INDEX NO. 607; 3 OF 3 CONTOURS TO MAXIMIZE PONDING EFFICIENCY. <br />N.T.S. <br />ALTERNATE DETAIL <br />TRENCH NTH GRAVEL <br />SILT FENCE DETAIL 10 <br />Hrs <br />WASTEWATER TREATMENT FACILITY <br />ADVANCED WATER TREATMENT UPGRADE <br />CITY OF ZEPHYRHILLS, FLORIDA <br />STORMWATER POLLUTION <br />PREVENTION PLAN <br />RUNOFF WATER <br />WITH SEDIMENT <br />1.5FT <br />IMENT <br />FDOT COARSE AGGREGATE NO 1 <br />GRAVEL (1FT DEPTH) <br />WIRE MESH/ <br />FILTER FABRIC <br />GRAVEL AND WIRE MESH DROP <br />INLET SEDIMENT FILTER DETAIL <br />NTS <br />DOUGLAS R. YOUNG <br />P.E. #44204 <br />F <br />E <br />C <br />Z <br />0 <br />V <br />U) <br />Z <br />0B <br />0 <br />w <br />0 <br />LL <br />PROJECT W. DATE: A <br />26110-025-01 MARCH 2O20 <br />om W. DWc NO: <br />C7 <br />