Laserfiche WebLink
J <br />Q <br />tr <br />r- <br />U <br />fkf <br />cn <br />U) <br />0 <br />Z <br />Q <br />Q' <br />0 <br />w <br />0 <br />Q <br />D' <br />0 <br />O_ <br />tL <br />J <br />_J <br />CL <br />w <br />N <br />rn <br />(n <br />cn <br />w <br />Z <br />O <br />ra <br />O <br />(V <br />N <br />0 <br />0 <br />W <br />Q <br />V) <br />PLOTTED: 3/25/2020 03:16 PM DAVID GENERAL STRUCTURAL NOTES <br />GENERAL CONDITIONS CONCRETE (CAST4N-PLACE) ALUMINUM <br />1. ALL STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE MECHANICAL, CIVIL, <br />ELECTRICAL., AND SHOP DRAWINGS AND SPECIFICATIONS. <br />2. THE CONTRACTOR SHALL REVIEW AND VERIFY DIMENSIONS SHOWN IN ALL PLANS AND <br />REVIEW ALL FIELD CONDITIONS THAT MAY AFFECT THE WORK DEPICTED ON THE DRAWINGS. <br />SHOULD DISCREPANCIES APPEAR, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IN <br />WRITING TO OBTAIN ENGINEER'S CLARIFICATION BEFORE COMMENCING WITH THE WORK. <br />3. FOR ALL ITEMS EMBEDDED IN OR PASSING THROUGH CONCRETE, THE CONTRACTOR SHALL <br />INITIALLY REFER TO MECHANICAL FOR TYPE, SIZE, LOCATION, AND SPECIAL INSTALLATION <br />REQUIREMENTS FOR THESE ITEMS. <br />4. THE CONTRACTOR SHALL TAKE ALL NECESSARY MEASURES TO PROTECT EXISTING <br />STRUCTURES FROM DAMAGE WHEN WORKING IN AND AROUND EXISTING STRUCTURES <br />PERFORMING WORK SUCH A DEMOLITION, FOUNDATION EXCAVATIONS, AND OTHERS. <br />5. SIZE AND LOCATION OF EQUIPMENT PADS AND ANCHOR BOLTS SHALL BE PER EQUIPMENT <br />MANUFACTURER'S REQUIREMENTS. <br />6. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND <br />SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, <br />EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. <br />7. STANDARD DETAILS APPLY TO ALL SIMILAR SITUATIONS ON THE PROJECT EXCEPT WHERE A <br />DIFFERENT DETAIL IS SHOWN_ <br />DESIGN CRITERIA <br />BUILDING CODES AND REFERENCES: <br />1. 2017 FLORIDA BUILDING CODE, 6TH EDITION (FBC) <br />2. REINFORCED CONCRETE: <br />WATER RETAINING ENVIRONMENTAL STRUCTURES: ACI 350-06 "CODE REQUIREMENTS <br />FOR ENVIRONMENTAL ENGINEERING CONCRETE STRUCTURES" <br />ALL OTHER STRUCTURES: ACI 318-14 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL <br />CONCRETE" <br />3. STRUCTURAL STEEL- AISC MANUAL OF STEEL CONSTRUCTION 14TH EDITION <br />4. ALUMINUM: ADM1-2010, ALUMINUM DESIGN MANUAL <br />5. LIVE LOADS: <br />WALKWAYS, STAIRWAYS AND LANDINGS: 100 PSF <br />SLABS ON GRADE 300 PSF <br />6. WIND DESIGN CRITERIA <br />RISK CATEGORY III <br />ULTIMATE DESIGN WIND SPEED, VULT 140 MPH <br />NOMINAL DESIGN WIND SPEED, VAM 108 MPH <br />EXPOSURE CATEGORY C <br />ENCLOSURE CLASSIFICATION ENCLOSED <br />FOUNDATIONS <br />GEOTECHNICAL REPORT: <br />1. GEOTECHNICAL ENGINEERING SERVICES REPORT "PROPOSED ZEPHYRHILLS WWTF AWT <br />UPGRADE, PREPARED BY PROFESSIONAL SERVICE INDUSTRIES, INC (PSI), PSI PROJECT NO. <br />07752716, DATED OCTOBER 15, 2018. ANY INTERPRETATION OF THE CONTENTS OF THE <br />GEOTECHNICAL REPORT IS THE RESPONSIBILITY OF THE CONTRACTOR <br />1. <br />ALL MATERIALS AND METHODS OF CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI 318 <br />1. <br />ALUMINUM DESIGN, DETAILING, FABRICATION, AND ERECTION SHALL CONFORM TO THE <br />REQUIREMENTS. <br />LATEST EDITION OF THE ALUMINUM DESIGN MANUAL. <br />2. <br />ALL CONCRETE SHALL BE AIR -ENTRAINED WITH A MINIMUM OF 4,000 PSI COMPRESSIVE <br />2. <br />ALUMINUM IN CONTACT WITH OR EMBEDDED IN CONCRETE OR MASONRY SURFACES SHALL <br />STRENGTH AT 28 DAYS UNLESS OTHERWISE NOTED. <br />BE COATED WITH A HEAVY COATING OF ALKALI RESISTANCE BITUMINOUS PAINT. <br />3. <br />WATER REDUCING AGENT SHALL BE IN ACCORDANCE WITH ASTM C494. <br />3. <br />ALL BOLTS USED IN CONNECTIONS WITH ALUMINUM MEMBERS SHALL BE STAINLESS STEEL <br />A316, UNLESS NOTED OTHERWISE. <br />4. <br />ALL CONCRETE SURFACES EXPOSED TO AIR, UNLESS OTHERWISE NOTED IN THE <br />SPECIFICATIONS, SHALL BE TREATED WITH AN APPROPRIATE CURING COMPOUND AS SOON <br />4. <br />ALL WELDING OF ALUMINUM STRUCTURES SHALL CONFORM TO "STRUCTURAL WELDING CODE <br />AS FINISHING IS COMPLETED OR FORMS ARE REMOVED. <br />- ALUMINUM", AWS D1.2, LATEST EDITION. <br />5. <br />ALL EXPOSED CORNERS SHALL HAVE A MINIMUM CHAMFER OF 3/4" UNLESS OTHERWISE <br />STAINLESS STEEL, <br />NOTED. <br />1 _ <br />STAINLESS STEEL PLATES, SHEETS AND STRUCTURAL SHAPES SHALL BE IN ACCORDANCE TO <br />6. <br />THE CONTRACTOR SHALL OBTAIN ENGINEER'S APPROVAL FOR THE LOCATIONS OF <br />ASTM A240. <br />CONSTRUCTION JOINTS THAT ARE NOT SHOWN ON THE DRAWINGS. <br />2. <br />STAINLESS STEEL MATERIALS SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE: <br />REINFORCING STEEL <br />a. EXTERIOR AND SUBMERGED USE: TYPE 316 <br />1. <br />REINFORCEMENT SHALL CONFORM TO ASTM A615, GRADE 60 REQUIREMENTS. WELDED WIRE <br />TYPE 316L (INHERE WELDED) <br />FABRIC SHALL CONFORM TO ASTM A315 REQUIREMENTS. ALL ACCESSORIES SHALL BE IN <br />CONFORMANCE WITH ACI 315 REQUIREMENTS. <br />3. <br />ALL WELDING OF STRUCTURAL STAINLESS STEEL SHALL CONFORM TO "STRUCTURAL <br />WELDING CODE - STAINLESS STEEL", AWS D1.6, LATEST EDITION. <br />2. <br />REINFORCING STEEL SHALL HAVE THE FOLLOWING CLEAR COVER UNLESS OTHERWISE <br />NOTED: <br />4. <br />STAINLESS STEEL BOLTS, NUTS AND WASHERS SHALL BE TYPE 316 IN ACCORDANCE TO ASTM <br />F593 UNLESS NOTED OTHERWISE. <br />a. CONCRETE CAST AGAINST EARTH 3" <br />b. FORMED SURFACE IN CONTACT WITH SOIL, SEWAGE, 2" <br />FLOTATION CONSIDERATION <br />WATER OR EXPOSED TO WEATHER <br />1. <br />STRUCTURES WERE DESIGNED TO BE NON -BUOYANT AFTER THEY ARE PLACED INTO <br />3. <br />LAP SPLICES SHALL BE AS SHOWN ON THE DRAWINGS. FOR LAP SPLICES NOT SHOWN ON THE <br />OPERATION. THEREFORE THE STRUCTURES MAY BE BUOYANT DURING CONSTRUCTION. <br />DRAWINGS, THE CONTRACTOR SHALL OBTAIN ENGINEERS APPROVAL <br />GENERAL CONTRACTOR SHALL PROTECT ALL STRUCTURES FROM FLOTATION DURING <br />CONSTRUCTION REGARDLESS OF GROUND WATER LEVELS UNTIL STRUCTURES ARE PLACED <br />4. <br />THE CONTRACTOR SHALL PREPARE PLACING DRAWINGS AND SCHEDULES IN CONFORMANCE <br />INTO OPERATION_ <br />WITH ACI 315 REQUIREMENTS. <br />COMPACTION GROUTING <br />1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND INCIDENTALS <br />REQUIRED TO PERFORM COMPACTION GROUTING PROGRAM FOR SINKHOLE MITIGATION <br />PURPOSES. REFER TO APPENDIX A.1 IN THE PROJECT SPECIFICATIONS FOR THE COMPACTION <br />GROUTING SPECIFICATION WHICH INCLUDES GROUTING REQUIREMENT AND LOCATIONS OF <br />GROUT POINTS ACROSS THE SITE. <br />STONE COLUMNS (VIBRO REPLACEMENT) <br />1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND INCIDENTALS <br />REQUIRED TO INSTALL STONE COLUMNS (VIBRO REPLACEMENT) WITHIN THE FOOTPRINT OF <br />THE FOUNDATION(S) OF THE FOLLOWING PROPOSED STRUCTURES: <br />- TERTIARY FILTERS AND FILTER PUMP STATION WET WELL <br />2. THE STONE COLUMN INSTALLATION SHALL MEET OR EXCEED THE PERFORMANCE CRITERIA <br />PROVIDED BELOW: <br />- MINIMUM ALLOWABLE BEARING PRESSURE....................................................2,500 PSF (NET) <br />- MAXIMUM TOTAL SETTLEMENT: ......................................................................... 1 1/2" <br />- MAXIMUM DIFFERENTIAL SETTLEMENT............................................................314" <br />3. STONE COLUMN INSTALLATION SHALL BE MONITORED AND SHALL NOT DAMAGE OR DISRUPT <br />ADJACENT STRUCTURES. REFER TO SPECIFICATION 02466 "STONE COLUMNS (VIBRO <br />REPLACEMENT" FOR ADDITIONAL REQUIREMENTS. <br />711 N ORANGE AVE, STE A <br />WINTER PAWL, FL 32789 <br />PH: 321-972.4989 <br />W E K I VA WMVA PROD. NO.1&169 <br />FL ENG BUSINESS NO.31920 <br />ENGINEERING <br />DERM D.MORRIS <br />DRAWN D.MORRIS <br />WE ItF1MloNs gr IMPM.1 qccm J.SOBCZAK <br />5. UNLESS OTHERWISE NOTED, THE MINIMUM REINFORCING FOR WALLS AND SLABS SHALL BE <br />AS FOLLOWS_ <br />MINIMUM REINFORCING <br />THICKNESS <br />6" <br />8" <br />10" <br />12" -16" <br />18" - 22" <br />24" <br />REINF. EACH WAY <br />#4 @ 12" <br />#5 @12" <br />#5 Q 12" <br />#5 @ 12" <br />#6 @ 12" <br />#7 @ 17 <br />LOCATION <br />CTR <br />CTR <br />EF <br />EF <br />EF <br />EF <br />STRUCTURAL STEEL <br />1. DESIGN, FABRICATION, ERECTION MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE <br />WITH THE LATEST AISC SPECIFICATIONS AND THE DESIGN DRAWINGS. <br />2. STEEL MATERIAL: <br />a. W-SHAPED SECTIONS: ASTM A992, GRADE 50 <br />b. HOLLOW STRUCTURAL SECTIONS: ASTM A500, GRADE B <br />a. ALL OTHER STRUCTURAL STEEL- ASTM A36 <br />d. ALL PIPE: ASTM A53, GRADE B <br />3. WELDED CONNECTIONS SHALL BE IN ACCORDANCE WITH THE LATEST AWS STRUCTURAL <br />WELDING CODE REQUIREMENTS. ELECTRODES SHALL BE E-70)OX. <br />4. BOLTED CONNECTIONS: <br />a. MAIN CONNECTIONS: 3/4" DIA, ASTM A325 BOLTS. HOLES: 13/16" DIA CONNECTION SHALL <br />BE "BEARING" TYPE WITH THREADS EXCLUDED FROM THE SHEAR PLANE <br />b. SECONDARY CONNECTION: 314" DIA, ASTM A307 GRADE A BOLTS. <br />a ALL CONNECTION SHALL HAVE A MINIMUM OF TWO BOLTS. GUSSET PLATES SHALL BE A <br />MINIMUM OF 3/8" THICK <br />d. ALL COLUMNS AND POSTS SHALL HAVE MILLED ENDS FOR FULL BEARING AT BASE <br />PLATES. <br />n noun Jo <br />CERTIFICATE OF AUTHORIZATION *1841 <br />730 NE WALDO ROAD, GAINESVILLE, FLORIDA 32641 / (352) 377-5821 <br />324 S HYDE PARK AVE, SUITE 250, TAMPA, FLORIDA 33606 / (813) 258-0703 <br />WATERTIGHTNESS OF REINFORCED CONCRETE WATER <br />RETAINING STRUCTURES <br />HYDROSTATICALLY TEST REINFORCED CONCRETE STRUCTURES WHICH WILL CONTAIN WATER <br />PER SPECIFICATIONS AND IN ACCORDANCE TO ACI 350.1-TIGHTNESS TESTING OF <br />ENVIRONMENTAL ENGINEERING STRUCTURES. ALL REPAIRS AND RETESTING OF TANKS SHALL BE <br />ACCOMPLISHED AT NO ADDITIONAL COST TO THE OWNER. REFER TO SPECIFICATION 01810 <br />"WATERTIGHTNESS FOR HYDRAULIC STRUCTURES" FOR TESTING REQUIREMENTS. <br />WASTEWATER TREATMENT FACILITY <br />ADVANCED WATER TREATMENT UPGRADE <br />CITY OF ZEPHYRHILLS, FLORIDA <br />® Jones Edmunds Z <br />STRUCTURAL ABBREVIATIONS <br />& <br />AND <br />EXP <br />EXPANSION <br />PEMB <br />PRE-ENGINEERED <br />AT <br />FE <br />FIRE EXTINGUISHER <br />METAL BUILDING <br /># <br />NUMBER <br />FF <br />FAR FACE, FINISHED <br />PERP <br />PERPENDICULAR <br />ADDTL <br />ADDITIONAL <br />FLOOR <br />PL <br />PLATE <br />ALUM <br />ALUMINUM <br />FG <br />FINISHED GRADE <br />PLF <br />POUND PER LINEAR <br />AEWS <br />AUTOMATIC END <br />FRP <br />FIBER REINFORCED <br />FOOT <br />WELDED STUD(S) <br />PLASTIC <br />PT <br />PRESSURE TREATED <br />ALT <br />ALTERNATE <br />FT <br />FOOT <br />PROJ <br />PROJECTION <br />APROX <br />APPROXIMATELY) <br />FTG <br />FOOTING <br />PSF <br />POUNDS PER SQUARE <br />BLD <br />BUILDING <br />FV <br />FIELD VERIFY <br />FOOT <br />BM <br />BEAM <br />GA <br />GAGE <br />PSI <br />POUNDS PER SQUARE <br />BOT <br />BOTTOM <br />GALV <br />GALVANIZED <br />INCH <br />CJ <br />CONTROL JOINT <br />HK <br />HOOK <br />PVC <br />POLYVINYL CHLORIDE <br />CL <br />CENTER LINE <br />HORIZ <br />HORIZONTAL <br />R <br />RADIUS <br />CLR <br />CLEAR <br />HSS <br />HOLLOW STRUCTURAL <br />REINF <br />REINFORCING <br />CMU <br />CONCRETE MASONRY <br />SECTION <br />REQD <br />REQUIRED <br />UNIT <br />HP <br />HIGH POINT <br />RO <br />ROUGH OPENING <br />COL <br />COLUMN <br />ID <br />INSIDE DIAMETER <br />SCHED <br />SCHEDULE(D) <br />CONC <br />CONCRETE <br />JT <br />JOINT <br />SIM <br />SIMILAR <br />CONN <br />CONNECTION <br />LB(S) <br />POUND(S) <br />Si <br />SAWCUT JOINT <br />CONST JT <br />CONSTRUCTION JOINT <br />LONG <br />LONGITUDINAL <br />SMS <br />SHEET METAL SCREW <br />CONT <br />CONTINUOUS <br />LP <br />LOW POINT <br />SPECS <br />SPECIFICATIONS <br />DIA <br />DIAMETER <br />MANUF <br />MANUFACTURER <br />SQ <br />SQUARE <br />DEG <br />DEGREE(S) <br />MATL <br />MATERIAL <br />SS <br />STAINLESS STEEL <br />DO <br />DITTO <br />MAX <br />MAXIMUM <br />STD <br />STANDARD <br />DWG <br />DRAWING <br />MECH <br />MECHANICAL <br />STL <br />STEEL <br />DWL <br />DOWEL(S) <br />MFR <br />MANUFACTURER <br />T/ <br />TOP OF <br />(E) <br />EXISTING <br />MIN <br />MINIMUM <br />TB <br />TIE BEAM <br />EA <br />EACH <br />MISC <br />MISCELLANEOUS <br />T&B <br />TOP AND BOTTOM <br />EF <br />EACH FACE <br />MO <br />MASONRY OPENING <br />THK <br />THICK <br />EJ <br />EXPANSION JOINT <br />MTL <br />METAL <br />THRU <br />THROUGH <br />EL <br />ELEVATION <br />NO <br />NUMBER <br />TOC <br />TOP OF CONCRETE <br />ELEC <br />ELECTRICAL <br />NTS <br />NOT TO SCALE <br />TOS <br />TOP OF STEEL <br />EMBED <br />EMBEDMENT <br />OC <br />ON CENTER <br />TYP <br />TYPICAL <br />EOC <br />EDGE OF CONCRETE <br />OD <br />OUTSIDE DIAMETER <br />UNO <br />UNLESS NOTED <br />EQ <br />EQUAL <br />OH <br />OPPOSITE HAND <br />OTHERWISE <br />EW <br />EACH WAY <br />OPNG <br />OPENING <br />VERT <br />VERTICAL <br />EXIST <br />EXISTING <br />PCs <br />PIECES <br />WWF <br />WELDED WIRE FABRIC <br />LEGEND <br />STRUCTURAL LEGEND APPLIES TO "S" SHEETS ONLY <br />EARTH FILL <br />'�' f <br />CONCRETE <br />-.' <br />EXISTING <br />UNDISTURBED EARTH <br />CONCRETE <br />COMPACTED GRANULAR FILL <br />DEMOLITION <br />`-'_�•�`= <br />GROUT OR SAND (AS NOTED) <br />STEEL <br />GENERAL STRUCTURAL NOTES, <br />ABBREVIATIONS & SYMBOLS <br />GRATING ® PRECAST CONCRETE <br />SYMBOLS <br />SYMBOLS APPLY TO "S" SHEETS ONLY <br />COLUMN OR WALL LINE TAG <br />-ram ELEVATION TAG <br />MV EL.O.00 <br />SECTION NO. <br />BUILDING SECTION <br />INDICATOR <br />DWG. NO. OF <br />SECTION VIEW <br />1 71 <br />DAVID S. MORRIS <br />P.E. 174717 <br />DETAIL NO. <br />A DETAIL <br />S00 INDICATOR <br />DWG. NO <br />INDICATES DETAIL SECTION <br />CUT (WHERE SHOWN) <br />z <br />_O <br />V <br />Z <br />O <br />V <br />w <br />0 <br />PRMW N0: DATE: <br />26110-025-01 MARCH 2O20 <br />mm W. DWG W. <br />S1 <br />