Laserfiche WebLink
PLOTTED: 3/24/2020 03:11 PM JOHN KRAMER <br />GENERAL NOTES <br />I F REFERENCED DATA <br />E <br />0 <br />0 <br />0 <br />cV <br />0 <br />0 <br />3 <br />-41 <br />w <br />0 <br />nB <br />N <br />lei <br />0 <br />C4 <br />oA <br />0 <br />0 <br />w <br />1. TOPOGRAPHIC SURVEY WAS PERFORMED BY DEUEL & ASSOCIATES <br />(727-822-4151), A LICENSED PROFESSIONAL LAND SURVEYOR, <br />DATED AUGUST 14, 2018. <br />2. RIGHT-OF-WAY LINES AND PROPERTY LINES OBTAINED FROM PASCO COUNTY <br />PROPERTY APPRAISER'S GIS DATABASE. <br />3. ALL ELEVATIONS ARE REFERENCED TO NGVD 1929. THE SITE -SPECIFIC FACTOR <br />TO CONVERT ELEVATIONS IN NGVD 1929 TO NAVD 88 IS NGVD-0.855=NAVD 88. <br />THE HORIZONTAL DATUM IS BASED UPON NORTH AMERICAN DATUM 83/1990 <br />ADJUSTMENT (NAD83/90), FLORIDA WEST ZONE. <br />4. THE SURVEY INFORMATION CONTAINED HEREIN WAS OBTAINED FOR DESIGN <br />PURPOSES AND MAY NOT BE AN ADEQUATE REPRESENTATION OF ACTUAL <br />CONDITIONS FOR PROJECT CONSTRUCTION. NO EXCAVATION WAS PERFORMED TO <br />VERIFY THE LOCATION OR EXISTENCE OF ANY UNDERGROUND UTILITIES, <br />ENCROACHMENTS, IMPROVEMENTS, STRUCTURES, OR FOUNDATIONS. <br />UNDERGROUND UTILITY LINE LOCATIONS ARE BASED UPON VISIBLE SURFACE <br />EVIDENCE, AVAILABLE RECORD DRAWING INFORMATION AND SCHEMATIC <br />INFORMATION PROVIDED BY UTILITY COMPANIES. INVERT, PIPE SIZE & TYPE AND <br />DIRECTION WAS OBTAINED WHERE ACCESSIBLE. <br />5. GEOTECHNICAL INVESTIGATION AND RECOMMENDATIONS PERFORMED BY <br />PROFESSIONAL SERVICE INDUSTRIES, INC. REFER TO REPORT DATED OCTOBER <br />15, 2018, APPENDIX A OF THE PROJECT SPECIFICATIONS. <br />GENERAL <br />6. THE CONTRACTOR SHALL COMPLY WITH ALL CONDITIONS AND REQUIREMENTS OF <br />ALL PERMITS (FDEP, FDOT, PASCO COUNTY BUILDING DEPARTMENT, ETC) <br />OBTAINED FOR THIS PROJECT. <br />7. THE CONTRACTOR IS ADVISED NOT TO SCALE FROM DRAWINGS BUT TO FIELD <br />VERIFY ALL DIMENSIONS. THE DIMENSIONS OF SPECIFIED AND FURNISHED <br />PRODUCTS AND MATERIALS TAKE PRECEDENCE OVER DIMENSIONS INDICATED ON <br />THE DRAWINGS. IF SIGNIFICANT DEVIATIONS OCCUR, THE CONTRACTOR SHALL <br />NOTIFY THE ENGINEER AT LEAST 72 HOURS PRIOR TO CONSTRUCTION FOR A <br />DETERMINATION AND RESOLUTION. <br />8. THE CONTRACTOR SHALL VERIFY THAT ALL CLEARANCES CAN BE MET. IF ANY <br />CLEARANCES CANNOT BE MET, THE CONTRACTOR SHALL NOTIFY THE OWNER AND <br />ENGINEER IN WRITING A MINIMUM OF 15 WORKING DAYS PRIOR TO <br />CONSTRUCTING AND SUCH ITEM. <br />CONSTRUCTION LAYOUT&IMITS OF CONSTRUCTION <br />9. THE CONTRACTOR SHALL OBTAIN THE SERVICES OF A PROFESSIONAL LAND <br />SURVEYOR LICENSED IN THE STATE OF FLORIDA FOR LAYOUT AND <br />ESTABLISHMENT OF ELEVATIONS OF NEW WORK. PROOF OF LICENSE SHALL BE <br />SUBMITTED TO THE ENGINEER BEFORE BEGINNING LAYOUT. <br />10. NO DISTURBANCE SHALL BE ALLOWED OUTSIDE OF THE RIGHT OF WAYS AND/OR <br />THE LIMITS OF CONSTRUCTION SHOWN ON THE DRAWINGS UNLESS APPROVED BY <br />THE OWNER OR SPECIFICALLY NOTED ON THE DRAWINGS. <br />EXISTING CONDITIONS <br />11. LOCATIONS, ELEVATIONS, AND DIMENSIONS OF EXISTING UTILITIES, STRUCTURES, <br />AND OTHER FEATURES ARE SHOWN BASED ON THE BEST INFORMATION <br />AVAILABLE AT THE TIME OF PREPARATION OF THESE DRAWINGS BUT ARE NOT <br />PURPORTED TO BE ABSOLUTELY CORRECT. THERE MAY BE OTHER <br />IMPROVEMENTS, UTILITIES, ETC. WHICH ARE WITHIN THE PROJECT AREA. <br />CONTRACTOR SHALL VERIFY, PRIOR TO CONSTRUCTION, THE LOCATIONS, <br />ELEVATIONS, DIMENSIONS, TYPES, AND CONDITIONS OF ALL EXISTING UTILITIES, <br />STRUCTURES, AND OTHER FEATURES (WHETHER OR NOT SHOWN ON THE <br />DRAWINGS) AFFECTING THE WORK. <br />12. PRIOR TO SHOP DRAWING PREPARATION AND SUBMITTAL AND PURCHASE OF <br />RELATED MATERIALS, THE CONTRACTOR SHALL FIELD VERIFY EXISTING UTILITIES <br />(LOCATION, SIZE, MATERIALS OF CONSTRUCTION, OUTSIDE DIAMETER, WALL <br />THICKNESS, ROUNDNESS, ELEVATIONS, ETC.) TO WHICH CONNECTION(S) WILL BE <br />MADE. CONTRACTOR SHALL INCLUDE FIELD MEASUREMENTS ON SHOP DRAWINGS. <br />13. THE CONTRACTOR SHALL NOTIFY THE OWNER AND ENGINEER IN WRITING <br />IMMEDIATELY IF CONFLICTS BETWEEN THE DRAWINGS AND ACTUAL CONDITIONS <br />ARE DISCOVERED. THE CONTRACTOR SHALL ACCURATELY RECORD ANY SUCH <br />CONFLICTS ON THE RECORD DRAWINGS. <br />14. ANY PROPERTY CORNERS, MONUMENTS, OR BENCH MARKS WITHIN THE PROJECT <br />AREA SHALL BE PROTECTED UNLESS OTHERWISE INDICATED FOR DEMOLITION. IF <br />ANY SUCH ITEMS ARE IN DANGER OF DAMAGE OR HAVE BEEN DAMAGED, THE <br />CONTRACTOR SHALL NOTIFY THE OWNER AND THE ENGINEER IMMEDIATELY AND <br />REPLACE/RESTORE THESE ITEMS AT NO ADDITIONAL COST TO THE OWNER. IF <br />OWNER CHOOSES TO SELF PERFORM THE WORK OR INCURS RELATED EXPENSES, <br />THE CONTRACTOR SHALL REIMBURSE THE OWNER FOR ALL COSTS ASSOCIATED <br />WITH THE EFFORT. <br />UTILITY COORDINATION <br />15. THE CONTRACTOR SHALL NOTIFY ALL UTILITIES NEAR THE PROJECT AREA AT <br />LEAST 48 HOURS PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE NOTIFYING <br />"SUNSHINE 811 CALL OF FLORID9 AT LEAST 48 HOURS PRIOR TO ANY DIGGING <br />WORK TO HAVE ALL EXISTING UTILITIES LOCATED. THE PHONE NUMBER IS <br />1-800-432-4770 AND THE WEB SITE IS WWW.SUNSHINE811.COM, IN INSTANCES <br />WHERE DIGGING OCCURS IN WETLANDS, THE NOTIFICATION PERIOD SHALL BE <br />INCREASED FROM AT LEAST 48 HOURS TO AT LEAST 10 DAYS. <br />16. FLORIDA LAW (FS 553.851) REQUIRES THAT PERSONS MAKING EXCAVATIONS IN <br />PUBLIC STREETS, ALLEYS, RIGHT-OF-WAYS OR UTILITY EASEMENTS MUST FIRST <br />OBTAIN INFORMATION ON LOCATIONS OF UNDERGROUND GAS PIPELINES. <br />17. THE CONTRACTOR SHALL PRESERVE AND MAINTAIN EXISTING UTILITIES, <br />STRUCTURES, AND OTHER FEATURES WITHIN THE PROJECT AREA. ANY DAMAGE <br />SHALL BE REPAIRED BY AND AT THE EXPENSE OF THE CONTRACTOR TO THE <br />SATISFACTION OF THE OWNER. <br />18. THE CONTRACTOR IS RESPONSIBLE FOR BRACING, SHORING, OR PROVIDING <br />OTHER MEANS NECESSARY TO PROTECT AND SUPPORT EXISTING UTILITIES, <br />STRUCTURES, AND OTHER FEATURES (EXPOSED OR UNEXPOSED) THAT MAY BE <br />IMPACTED BY THE CONTRACTOR'S WORK. <br />19. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING POWER/TELEPHONE <br />COMPANIES AND ARRANGING TO HAVE UTILITIES POLES HELD AND/OR GUY WIRES <br />REMOVED AND REPLACED, IF NECESSARY FOR CONSTRUCTION, AT NO ADDITIONAL <br />COST TO THE OWNER. <br />SAFETY <br />20. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BE FAMILIAR WITH THE OSHA <br />EXCAVATION SAFETY STANDARDS AND TO ABIDE BY THEM AS COVERED UNDER <br />THE FLORIDA TRENCH SAFETY ACT. <br />21. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION SAFETY. <br />RESTORATION <br />22. ALL PAVING, STABILIZED EARTH, DRIVEWAYS, CURBS, SIDEWALKS, FENCES, SOD, <br />LANDSCAPING, CULVERTS, ETC. DISTURBED BY CONSTRUCTION ACTIVITIES SHALL <br />BE RESTORED BY AND AT THE EXPENSE OF THE CONTRACTOR TO THE <br />SATISFACTION OF THE OWNER. <br />23. ALL EXISTING SIGNS, FENCING AND MAILBOXES SHALL BE REMOVED AND <br />REINSTALLED OR REPLACED AS REQUIRED DURING CONSTRUCTION., AND SHALL <br />BE RESTORED BY AND AT THE EXPENSE OF THE CONTRACTOR TO THE <br />SATISFACTION OF THE OWNER. <br />ACCESS/MAINTENANCE OF FACILITIES <br />24. THE CONTRACTOR SHALL PROVIDE ACCESS TO ALL EXISTING UTILITIES/FACILITIES <br />AND MAINTAIN UNINTERRUPTED SERVICES THROUGHOUT THE CONTRACT PERIOD. <br />PIPING NOTES <br />25. LAY PIPE TO UNIFORM GRADE BETWEEN INDICATED ELEVATION POINTS. <br />CONTRACTOR SHALL TAKE CARE TO PROVIDE PROPER GRADE ELEVATIONS AND <br />ALIGNMENTS. <br />26. SIZE OF FITTINGS SHOWN ON PLANS SHALL CORRESPOND TO THE ADJACENT <br />STRAIGHT RUN OF PIPE UNLESS NOTED OTHERWISE. TYPE OF JOINT AND FITTING <br />MATERIAL SHALL BE AS SPECIFIED FOR THE ADJACENT STRAIGHT RUN OF PIPE <br />UNLESS NOTED OTHERWISE. <br />27. CONTRACTOR SHALL CONSTRUCT NEW BELOW GRADE PIPING WITH A MINIMUM <br />COVER OF 36" . IF A MINIMUM COVER OF 36" CANNOT BE ACHIEVED, THE <br />CONTRACTOR SHALL NOTIFY THE ENGINEER IN WRITING. <br />28. CONTRACTOR SHALL INSTALL MINIMUM OF 1 /4" THICK NEOPRENE PADDING <br />BETWEEN PIPE AND SUPPORTS FOR DUCTILE IRON PIPE AND PIPE WITH <br />COATINGS. <br />DEm n AHOLMES <br />DRAww JKRAMER ionqw. <br />CERTIFICATE OF AUTHORIZATION *1841 <br />CICKED TFRIEDRICH 730 NE WALDO ROAD, GAINESVILLE, FLORIDA 32641 / (352) 377- 5821 <br />uk DA N REVISM I BY 1APPM.1 324 S HYDE PARK AVE, SUITE 250, TAMPA, FLORIDA 33606 / (813) 258- 0703 <br />UTILITY SEPARATION <br />29. EACH PROPOSED UTILITY SHALL BE LAID TO ACHIEVE THE MINIMUM HORIZONTAL <br />SEPARATION BETWEEN IT AND OTHER UTILITIES IN ACCORDANCE WITH THE <br />TYPICAL UTILITY HORIZONTAL SEPARATION DETAIL AND FDEP REQUIREMENTS. <br />30. AT LOCATIONS WHERE A PROPOSED UTILITY CROSSES ANOTHER UTILITY, THE <br />PROPOSED UTILITY SHALL BE INSTALLED IN ACCORDANCE WITH THE TYPICAL <br />UTILITY CONFLICT DETAIL AND FDEP REQUIREMENTS. <br />31. IN THE EVENT THAT A UTILITY CONFLICT CAN NOT BE RESOLVED BY MAKING A <br />MINOR ROUTE ADJUSTMENT OR BY UTILIZING THE TYPICAL UTILITY CONFLICT <br />DETAIL, THE CONTRACTOR SHALL SUBMIT A RELOCATION PLAN TO THE ENGINEER <br />FOR APPROVAL PRIOR TO COMMENCING WORK. ALL RELOCATION EFFORTS SHALL <br />BE SUBJECT TO THE APPROVAL OF THE ENGINEER AND ANY AFFECTED UTILITY <br />COMPANIES. <br />PROJECT SPECIFIC <br />32. ALL UTILITIES SHALL BE KEPT IN OPERATION EXCEPT WITH THE WRITTEN <br />CONSENT OF THE UTILITY OWNER. <br />33. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING EXISTING UTILITIES <br />AND PAVEMENT THAT THE CONTRACTOR DAMAGES DURING CONSTRUCTION AT NO <br />ADDITIONAL COST TO THE OWNER. REPAIRS SHALL BE CONDUCTED UNDER THE <br />SUPERVISION OF THE OWNER AND IN ACCORDANCE WITH THE CONTRACT <br />DOCUMENTS AND THESE DRAWINGS. <br />34. THE CONTRACTOR SHALL PROVIDE A MINIMUM OF TWO WEEKS NOTICE TO THE <br />OWNER PRIOR TO CONNECTING THE NEW CONSTRUCTION, EQUIPMENT, AND <br />PIPING TO THE CITY OF ZEPHYRHILLS WWTF. THE CONTRACTOR IS RESPONSIBLE <br />FOR COORDINATING AND SCHEDULING EACH CONNECTION WITH THE OWNER TO <br />ENSURE THAT THERE ARE MINIMAL INTERRUPTIONS TO EACH SYSTEM. <br />35. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING AND STABILIZING <br />POWER POLES DURING CONSTRUCTION. THE CONTRACTOR SHALL CONTACT THE <br />ELECTRIC UTILITY PROVIDER AND COORDINATE WITH THEM. <br />36. CONTRACTOR SHALL REMOVE TREE(S) WHEN IN DIRECT CONFLICT W/ PROPOSED <br />WORK, AS APPROVED BY THE ENGINEER. CONTRACTOR SHALL OBTAIN PERMIT(S) <br />REQUIRED. <br />WASTEWATER TREATMENT FACILITY <br />ADVANCED WATER TREATMENT UPGRADE <br />CITY OF ZEPHYRHILLS, FLORIDA <br />GENERAL NOTES <br />7.;-t; _3 I :1 <br />MICHAEL L. CLARK <br />P.E. #48898 <br />F <br />E <br />C <br />Z <br />O <br />F-- <br />C.� <br />M <br />OC <br />F- <br />Z <br />O B <br />C.� <br />O <br />ILL <br />PROJECT W. DATE A <br />26110-025-01 MARCH 2O20 <br />G4 <br />