Laserfiche WebLink
MAIN DISTRIBUTION <br />Three Phase, 4 Wires, 120/208 Volts, Solid Neutral, Grounding Bar, 400 Amps MB Adjusted at 300 Amps <br />Trip, 42 Poles, Indoor, Surface Mounted. <br />PANEL "B„ <br />SQUARE D N0442L4C+MQMB4LA+MH62+NC62V(S). Main Breaker LAL36400MC <br />Kw per Phase <br />Pole <br />ole <br />Brk <br />Wiring <br />Load Description <br />Load Description <br />Wiring <br />Brk <br />Pole <br />A <br />B <br />C <br />1 <br />20 <br />(2) #12 AWG, (1) #14 G <br />Small AC Unit Server Room 117 <br />Southeast Area <br />1.10 <br />Water Cooler Hall 140 <br />South Central Area <br />(2) #12 AWG, (1) #14 G <br />20 <br />2 <br />3 <br />1.10 <br />4 <br />5 <br />20 <br />(2) #12 AWG, (1) #14 G <br />General Purpose Receptacles Rooms 115, 116 <br />2.70 <br />General Purpose Receptacles Hall, Electrical, <br />(2) #12 AWG, (1) 414 G <br />20 <br />6 <br />South Central Area <br />Storage and Mechanical Rooms South Central Area <br />7 <br />20 <br />(2) #12 AWG, (1) #14 G <br />IT Server Equipment Room 117 <br />1.80 <br />General Purpose Receptacles Open Office 120 <br />(2) #12 AWG, (1) #14 G <br />20 <br />8 <br />South Central Area <br />South Central Area <br />9 <br />20 <br />(2) #12 AWG, (i) #14 G <br />General Purpose Receptacles Rooms 129, 130 <br />2.52 <br />General Purpose Receptacles Open Office 120 <br />(2) #12 AWG, (1 } #14 G <br />20 <br />10 <br />South Central Area <br />South Central Area <br />11 <br />20 <br />(2) #12 AWG. (1) #14 G <br />Flushometers Restrooms 113 and 114. Service WP <br />- <br />1.80 <br />General Purpose Receptacles Restroom 113,114, <br />(2) #12 AWG, (1) #14 G <br />20 <br />12 <br />Receptacle Condensing Unit #2 South Central Area <br />Rooms 115, 116 and Hall 140 South Central Area <br />13 <br />80 <br />(3) #4 AWG, <br />Air Handling Unit #2 <br />18.71 kW Heater <br />7.00 <br />Air Handling Unit #2 <br />(2) 4.2 HP Compressor <br />(3) #8 AWG, <br />45 <br />14 <br />15 <br />7.00' <br />16 <br />(1) #8 G <br />(1) 2 HP Motor <br />(1) 1 HP Motor <br />(1) #8 G <br />17 <br />7.00" <br />18 <br />19 <br />20 <br />(2) #12 AWG, (1) #14 G <br />Emergency Lighting <br />1.74 <br />General Purpose Receptacles Conference Room 121 <br />(2) #12 AWG, (1) #14 G <br />20 <br />20 <br />South Central Area <br />South Central Area <br />21 <br />20 <br />(2) #12 AWG, (1) #14 G <br />Emergency Lighting <br />1.60 <br />General Purpose Receptacles Conference Room <br />(2) #12 AWG, (1) #14 G <br />20 <br />22 <br />North Central Area <br />122 South Central Area <br />23 <br />20 <br />(2) #12 AWG, (1) #14 G <br />General Lighting Open Office Space 120 <br />2.40 <br />General Lighting Restrooms 113 and 114 <br />(2) #12 AWG, (1) #14 G <br />20 <br />24 <br />South Central Area <br />South Central Area <br />25 <br />20 <br />(2) #12 AWG, (1) #14 G <br />General Lighting Copy Room 127, Halls 137 and 139 <br />2.30 <br />General Lighting Rooms 115, 116, 117, 118a, 118b <br />(2) #12 AWG, (1) #14 G <br />20 <br />26 <br />North -South Central Area <br />and 119 South Central Area <br />27 <br />20 <br />(2) #12 AWG, (1) #14 G <br />General Lighting Conference Rooms 121 and 122 <br />South Central Area <br />1.60 <br />VAV Boxes 2-1 Thru BP Actuators <br />(2) #12 AWG, (1) #14 G <br />20 <br />26 <br />29 <br />15.86 <br />30 <br />150 <br />See Single Line <br />Load Center "A" <br />Load Center "BR" <br />See Single Line <br />100 <br />31 <br />11.82 <br />32 <br />Diagram this Sheet <br />Diagram this Sheet <br />33 <br />15.72 <br />34 <br />35 <br />4.32 <br />36 <br />100 <br />See Single Line <br />Load Center "C" <br />- <br />37 <br />7.54 <br />38 <br />Diagram this Sheet <br />39 <br />8-53 <br />40 <br />41 <br />42 <br />Total Connected Load per Phase in kiloWatts <br />33.30 <br />38.07 <br />34.38 <br />Connected Average amperes per phase 294.0 Amperes <br />Estimated Demand Factor = 70% Average Demand Current per Phase : 0.7 x 294 = 206 Amperes <br />u <br />SINGLE LINE DIAGRAM <br />Existing Underground Service Drop to Remain C 4" (3) 350 <br />KMill THHN (1) 4/0 AWG THHN (N). Aluminum. <br />New Service Service Extension C 4" (3) 350 KMill THHN (1) <br />4/0 AWG THHN (N), 1/0 (G) Aluminum <br />New Service Grounding Conductor (1) #1/0 AWG Aluminum. <br />Bond It to the Cold Water Grid. <br />New Grounding Electrodes: (3) 3/4" x 10' Copper Clad Steel <br />Grounding Bars one on each Corner of a 10" Side Equilateral <br />Triangle Tied with a 1/0 Aluminun Grounding Conductor <br />101 <br />3uilding <br />isting Grade <br />C <br />Room <br />136 <br />5 } is C 1-1/2", (3) # 2 AWG THW, (1) # 6 (N), (1) # 8 AWG (G) <br />6 C 1-1 /4", (3) # 4 AWG THW, (1) # 8 (N), (1) # 8 AWG (G) <br />400 Amperes, Three Phase, 208 Volts, Feed Only, Meter Pak <br />Center, Rainproof, UL Listed, 100KA, Bolt Lugs, Neutral and <br />SB Grounding Bars, for Aluminun Conductors Only. Coordinate <br />Installation with Utility Company. <br />Square D Catalog No. EZ M340OTBU <br />LOAD CENTER "A" <br />Three Phase, 4 Wires, 120/208 Volts, Floating Neutral, Grounding Bar, 200 Amps MLO, 24 Poles, Indoor, <br />Surface Mounted, With Door. <br />SQUARE D Q0324L200G+QOC24US <br />Kw per Phase <br />Pole <br />Brk <br />Wiring <br />Load Description <br />Load Description <br />Wiring <br />g <br />Brk <br />Pole <br />A <br />B <br />C <br />1 <br />20 <br />(2) #12 AWG, (1) #14 G <br />Hallways and Mechanical Room General Purpose <br />2.52 <br />General Purpose Receptacles Rooms 106 and 107 <br />(2) #12 AWG, (1) #14 G <br />20 <br />2 <br />Receptacles Southwest Area <br />Northwest Area <br />3 <br />20 <br />(2) #12 AWG, (1) #14 G <br />General Purpose Receptacles Rooms 101 and 102 <br />2 52 <br />(general Purpose Receptacles Rooms 107 and 108 <br />(2) #12 AWG, (1) #14 G <br />20 <br />4 <br />Southwest Area <br />Southwest Area <br />5 <br />20 <br />(2) #12 AWG, (1) #14 G <br />General Purpose Receptacles Rooms 102 and 103 <br />Southwest Area <br />3.06 <br />Copier of Hall 139 <br />(2) #12 AWG, (1) #14 G <br />20 <br />6 <br />7 <br />20 <br />(2) #12 AWG, (1) #14 G <br />General Purpose Receptacles Rooms 104 and 105 <br />. L 70 <br />General Purpose Receptacles Rooms 109 and 110 <br />(2) #12 AWG, (1) #14 G <br />20 <br />8 <br />Southwest Area <br />Southwest Area <br />9 <br />50 <br />() #AWG, <br />AIR HANDLER UNIT # 1 : <br />4.50* <br />CONDENSING UNIT # 1: <br />(3) #8 AWG, <br />10 <br />11 <br />(1) 2 HP BLOWER <br />4.50* <br />(1) 5.6 HP COMPRESSOR <br />40 <br />12 <br />(1)#10G <br />(1) 1 1.25 kW HEATER <br />(2) 112 HP FAN MOTOR <br />(1)#10G <br />13 <br />4 50* <br />14 <br />15 <br />(2 #8 AWG, <br />) <br />Tankless Instantaneous Water Heater <br />i-E;O <br />General Lighting Rooms 105, 106 and 107 <br />Northwest Area <br />(2) #12 AWG, (1) #14 G <br />20 <br />16 <br />40 <br />(1) #10 G <br />Nominal Load 6,000 Watts <br />17 <br />7.6 <br />General Purpose Lighting Rooms 101, 102, 103, and <br />(2) #12 AWG, (1) #14 G <br />20 <br />18 <br />104 West Area <br />19 <br />20 <br />2 #12 AWG, 1 #14 G <br />O O <br />General Lighting Halls 133, 136 and 137, Storage, <br />1.60 <br />Emer enc Lighting Southwest Area <br />g y g 9 <br />(2) #12 AWG, (1) #14 G <br />20 <br />20 <br />Janitor and Mechanical Rooms Southwest Area <br />21 <br />20 <br />(2) #12 AWG, (1) #14 G <br />General Purpose Lighting Roorns 108, 109 and 110 <br />0.60 <br />Spare <br />20 <br />22 <br />Southwest Area <br />23 <br />20 <br />(2) #12 AWG, (1) #14 G <br />VAV Boxes 1-1 thru BP Actuators <br />20 <br />24 <br />25 <br />26 <br />27 <br />28 <br />29 <br />30 <br />Total Connected Load per Phase in kiloWatts <br />11.32 <br />15.22 <br />15.36 <br />Average amperes per phase 116.0 Amperes <br />(') Since the Heating Elements (8,000 Watts) of the AHU and the Compressors of the Condensing Unit will not operate simultaneously only the largest of the two electrical loads is <br />considered in the Total Load Calculations. <br />LOAD CENTER 11Cif <br />Three Phase, 4 Wires, 120/208 Volts, Floating Neutral, Grounding Bar, 125 Amps MLO, 24 Poles, Indoor, <br />Surface Mounted, With Door. <br />SQUARE D Q0324L125G+QOC24US <br />Kw per Phase <br />Pole <br />Brk <br />Wiring <br />Load Description <br />Load Description <br />Wiring <br />Brk <br />Pole <br />A <br />B <br />C <br />1 <br />20 <br />(2) #12 AWG, (1) #14 G <br />Hallways and Mechanical Room General Purpose <br />3.68 <br />Tankless Instantaneous Water Heater <br />(2) #10 AWG, (1) #10 G <br />20 <br />2 <br />Receptacles Northeast Area <br />Nominal Load 2,600 Watts <br />3 <br />20 <br />(2) #12 AWG, (1) #14 G <br />Accounting Room 134 General Purpose Receptacles <br />3 68 <br />Rooms 127 and 128 General Purpose Receptacles <br />(2) #12 AWG, (1) #14 G <br />20 <br />4 <br />Northeast Area <br />Northeast Area <br />5 <br />20 <br />(2) #12 AWG, (1) #14 G <br />Accounting Room 134 General Purpose Receptacles <br />1.22 <br />Plotter, Room 127 <br />(2) #12 AWG, (1) #14 G <br />20 <br />6 <br />Northeast Area <br />Northeast Area <br />7 <br />20 <br />(2) #12 AWG, (1) #14 G <br />Offices 135 and 136 General Purpose Receptacles <br />Northeast Area <br />1 ^46 <br />Emergency Lights NE Section <br />(2) #12 AWG, (1) #14 G <br />10 <br />8 <br />9 <br />30 <br />AWG, <br />(1) #)#1 <br />AIR HANDLER UNIT_ # 3: <br />(1) 1/2 HP BLOWER <br />2-40 <br />CONDENSING UNIT # 3: <br />(1) 3 HP COMPRESSOR <br />(3) #10 AWG, <br />25 <br />10 <br />11 <br />2.40' <br />12 <br />( 0G <br />(1) 7.2 kW HEATER <br />(1) 1 /8 HP FAN MOTOR <br />(1)#10G <br />13 <br />2 40' <br />14 <br />15 <br />20 <br />(2) #12 AWG, (1) #14 G <br />General Lighting Rooms 128 and 134 <br />2.45 <br />General Lighting Rooms 131, 132, 133 and 135 <br />(2) #12 AWG, (1) #14 G <br />20 <br />16 <br />Northeast Area <br />Northeast Area <br />17 <br />20 <br />(2) #12 AWG, (1) #14 G <br />General Lighting Room 134 Work Area <br />Northeast Area <br />1.0 <br />VAV Boxes 2-1 Thru BP Actuators <br />(2) #12 AWG, (1) #14 G <br />20 <br />18 <br />19 <br />20 <br />SPARE <br />20 <br />21 <br />22 <br />23 <br />24 <br />Total Connected Load per Phase in kiloWatts <br />7.54 <br />8.53 <br />4.62 <br />Average amperes per phase 57.0 Amperes <br />() Since the Heating Elements (8,000 Watts) of the AHU and the Compressors of the Condensing Unit will not operate simultaneously only the largest of the two electrical loads is <br />considered in the Total Load Calculations. <br />Three Phase, 4 Wires, 120/208 Volts, Floating Neutral, Grounding Bar, 125 Amps MLO, 20 Poles, Indoor, <br />�� �� <br />LOAD CENTER "BR" <br />Flush Mounted, With Door. <br />SQUARE D Q0320L125G+QOC20US <br />Kw per Phase <br />Pole <br />Brk <br />Wiring <br />Load Description <br />Load Description <br />Wiring <br />Brk <br />Pole <br />A <br />B <br />C <br />1 <br />20 <br />(2) #12 AWG, (1) #14 G <br />Break Room 125 General Purpose Receptacles <br />2.16 <br />Break Room 125 East Countertop Receptacles <br />(2) #12 AWG, (1) #14 G <br />20 <br />2 <br />North-Central Area <br />North-Central Area <br />3 <br />20 <br />(2) #12 AWG, (1) #14 G <br />Break Room 125 North Countertop Receptacles <br />4.40 <br />l ankless Instantaneous Water Heater <br />(2) #10 AWG, (1) #10 G <br />30 <br />4 <br />North-Central Area <br />Nominal Load 2,600 Watts <br />5 <br />20 <br />(2) #10 AWG, (1) #10 G <br />Break Room Sink Tankless Instantaneous Water <br />3.30 <br />Break Room 125 Refrigerator <br />(2) #12 AWG, (1) #14 G <br />20 <br />6 <br />Heater North-Central Area 2,600 Watts <br />North Central Area <br />7 <br />20 <br />(2) #12 AWG, (1) #14 G <br />Reception/Lobby 126 General Purpose Receptacles <br />1.80 <br />Copy Room 127 General Purpose Receptacles <br />(2) #12 AWG, (1) #14 G <br />20 <br />8 <br />North-Central Area <br />North Central Area <br />9 <br />20 <br />(2) #12 AWG, (1) #14 G <br />Copy Room 127 Copier <br />3.20 <br />General Lighting Outdoor Porch and Lobby 126 <br />(2) #12 AWG, (1) #14 G <br />20 <br />10 <br />North Central Area <br />North Central Area <br />11 <br />20 <br />(2) #12 AWG, (1) #14 G <br />General Lighting Hall 123, Lobby 126, Reception <br />2.15 <br />General Lighting Break Room 125 and Restroom <br />(2) #12 AWG, (1) #14 G <br />20 <br />12 <br />North Central Area <br />124 North Central Area <br />13 <br />20 <br />(3) #12 AWG, (1) #14 G <br />2 HP Electric Motor of the SKYFOLD Retractable <br />0.50 <br />Spare <br />20 <br />14 <br />15 <br />0.50 <br />16 <br />Partition. <br />17 <br />0.50 <br />18 <br />19 <br />20 <br />Total Connected Load per Phase in kiloWatts <br />4.46 <br />8.10 <br />5.95 <br />Average amperes per phase 52-0 Amperes <br />PROPOSED <br />1 ELEC PANELS <br />architect <br />SONIA FUEREDI DESIGN <br />2860 WILTSHIRE DRIVE <br />DECATUR, GA 30030 <br />plumbing & electrical <br />HUGO MADRIGAL, PE <br />4911 Molokai Drive <br />Naples, FL 33412 <br />Florida Registration 39560 <br />mechanical <br />CONSULTING ENG. <br />ASSOCIATES, INC. <br />8365 Gunn Highway <br />Tampa, Florida 33626 <br />GENERAL CONTRACTOR <br />general contractor <br />RTD CONSTRUCTION, Inc <br />5344 9th Street <br />Zephyrhills, Florida 33542 <br />OC <br />U <br />Z <br />J <br />O <br />LL <br />V) <br />J <br />_J <br />zz� <br />00 <br />= <br />UJ <br />Q <br />N <br />O <br />oC <br />Imo; <br />z <br />zF <br />- <br />LLI <br />W <br />Cn <br />Q <br />cr <br />Z <br />= <br />W <br />O� <br />U <br />U <br />0 <br />z <br />L <br />Q <br />00 <br />L <br />0 <br />CC <br />0c0 <br />rn <br />PROJECT NO: 2014-001 <br />DATE 2014_0327 <br />REVISIONS <br />i 1Uu0, MAD: L PF <br />PE 39560 <br />E-3 <br />