Laserfiche WebLink
ABBREVIATIONS <br />* NOTE ABBREVIAT M NO SYMM" CON MM <br />A <br />AFF <br />ABOVE FINISHED FLOOR <br />AD <br />ACCESS DOOR <br />ACU <br />AIR CONDITIONING UNIT <br />ACCU <br />AIR COOLED CONDENSING UNIT <br />AHU <br />AIR HANDLING UNIT <br />AUTO <br />AUTOMATIC <br />A/E <br />ARCHITECT/ENGINEER <br />B <br />BHP <br />BRAKE HORSEPOWER <br />BTU <br />BRITISH THERMAL UNIT <br />BLDG <br />BUILDING <br />BS <br />BIRD SCREEN <br />C <br />CLG <br />CEILING <br />COMP <br />COMPRESSOR <br />CONC <br />CONCRETE <br />CONN <br />CONNECTION <br />CONTR <br />CONTRACTOR <br />CFH <br />CUBIC FEET PER HOUR <br />CFM <br />CUBIC FEET PER MINUTE <br />CFS <br />CUBIC FEET PER SECOND <br />CEA <br />CONSULTING ENGINEERING ASSOCIATES <br />COL <br />COLUMN <br />D <br />DET <br />DETAIL <br />DIA <br />DIAMETER <br />DIM <br />DIMENSION <br />DX <br />DIRECT EXPANSION <br />DMSD <br />DUCT MOUNTED SMOKE DETECTOR <br />DN <br />DOWN <br />DB <br />DRY BULB <br />DISCH <br />DISCHARGE <br />E <br />ELEV <br />ELEVATION <br />ENGR <br />ENGINEER <br />EAT <br />ENTERING AIR TEMPERATURE <br />EQUIP <br />EQUIPMENT <br />EA <br />EXHAUST AIR <br />EF <br />EXHAUST FAN <br />ESP <br />EXTERNAL STATIC PRESSURE <br />F <br />FV <br />FACE VELOCITY <br />FT <br />FEET <br />FPM <br />FEET PER MINUTE <br />FLEX <br />FLEXIBLE <br />FC <br />FLEXIBLE CONNECTOR <br />FLR <br />FLOOR <br />G <br />GALV <br />GALVAN 1 ZED <br />GA <br />GAUGE <br />H <br />HTR <br />HEATER <br />HTG <br />HEATING <br />HC <br />HEATING COIL <br />HORIZ <br />HORIZONTAL <br />HP <br />HORSEPOWER <br />L <br />LVG <br />LEAVING <br />LAT <br />LEAVING AIR TEMPERATURE <br />LG <br />LONG <br />M <br />MBH <br />1000 BTU PER HOUR <br />MECH <br />MECHANICAL <br />MAIR <br />MIXED AIR <br />MAT <br />MIXED AIR TEMPERATURE <br />MOTDPR <br />MOTORIZED DAMPER <br />MT <br />MECHANICAL TRADES <br />MTD <br />MOUNTED <br />MTG <br />MOUNTING <br />N <br />N.C. <br />NORMALLY CLOSED <br />N.O. <br />NORMALLY OPEN <br />NIC <br />NOT IN CONTRACT <br />NTS <br />NOT TO SCALE <br />0 <br />OA <br />OUTSIDE AIR <br />OAI <br />OUTSIDE AIR INTAKE <br />OAT <br />OUTSIDE AIR TEMPERATURE <br />P <br />PVC <br />POLYVINYL CHLORIDE <br />LBS/HR <br />POUNDS PER HOUR <br />PSI <br />POUNDS PER SQUARE INCH <br />PSIA <br />POUNDS PER SQUARE INCH ABSOLUTE <br />PSIG <br />POUNDS PER SQUARE INCH GAUGE <br />PRESS <br />PRESSURE <br />PD <br />PRESSURE DROP <br />Q <br />QTY <br />QUANTITY <br />R <br />R <br />REFRIGERANT <br />REG <br />REGISTER <br />RM <br />ROOM <br />REQ'D <br />REQU I RED <br />RA <br />RETURN AIR <br />RPM <br />REVOLUTIONS PER MINUTE <br />S <br />SCH <br />SCHEDULE <br />SHT <br />SHEET <br />SP.HT. <br />SPECIFIC HEAT <br />SPECS <br />SPECIFICATIONS <br />SQFT. <br />SQUARE FEET <br />STD <br />STANDARD <br />SP <br />STATIC PRESSURE <br />STL <br />STEEL <br />STRUCT <br />STRUCTURAL <br />SA <br />SUPPLY AIR <br />SUSP <br />SUSPENDED <br />SYS <br />SYSTEM <br />SIM <br />SIMILAR <br />SLV <br />SLEEVE <br />S.F.F.A. <br />SQUARE FEET FREE AREA (NET) <br />T <br />TEMP <br />TEMPERATURE <br />T <br />THERMOSTAT <br />TSP <br />TOTAL STATIC PRESSURE <br />TYP <br />TYPICAL <br />U <br />UL <br />UNDERWRITERS LABORATORIES <br />V <br />VAV <br />VARIABLE AIR VOLUME BOX <br />VI <br />VIBRATION ISOLATOR <br />VERT <br />VERTICAL <br />VOL <br />VOLUME <br />VD <br />VOLUME DAMPER <br />W <br />WB <br />WET BULB <br />DUCTWORK <br />R MAY OR MAY NOT BE UBED ON 7M PROJECT <br />NET INSIDE DIMENSION <br />SIZE IN INCHES (PLAN DIM. FIRST) <br />RADIUS TYPE ELBOW <br />SQUARE TYPE ELBOW <br />WITH TURNING VANES <br />VOLUME DAMPER <br />® SUPPLY AIR DIFFUSER <br />z RETURN AIR GRILLE <br />z EXHAUST AIR GRILLE <br />�- DENOTES DIFFUSER IDENTIFICATION <br />00 DENOTES CFM <br />6x6 <br />_�� DENOTES NECK SIZE <br />Q <br />THERMOSTAT 48' AFF. <br />® <br />SYSTEM CONTROLLER <br />--LJ--► <br />1' DOOR UNDERCUT <br />SD <br />DUCT MOUNTED <br />SMOKE DETECTOR, PROVIDED BY <br />DIVISION 16, INSTALLED BY <br />DIVISION 15. SEE ELECTRICAL <br />PLANS FOR EXACT QUANTITY. <br />M❑ <br />MOTORIZED DAMPER <br />CEILING MOUNTED <br />EXHAUST AIR FAN <br />GENERAL NOTES <br />1. PLANS INDICATE THE SCHEMATIC LAYOUT AND LOCATION OF THE MECHANICAL <br />SYSTEM COMPONENTS. UNLESS SPECIFIC DIMENSIONS ARE NOTED, THE ACTUAL <br />LOCATION OF THESE COMPONENTS SHALL BE DETERMINED IN THE FIELD IN <br />COORDINATION WITH THE WORK OF OTHER TRADES, THE USE OF <br />MANUFACTURER'S SHOP DRAWINGS AND SIMILAR CERTIFIED DATA. PLANS SHALL <br />NOT BE SCALED. <br />2. NO EXCLUSIONS FROM OR LIMITATIONS IN THE LANGUAGE USED IN THE <br />CONTRACT DOCUMENTS SHALL BE INTERPRETED AS MEANING THAT THE <br />EQUIPMENT, APPURTENANCES, AND/OR ACCESSORIES NECESSARY FOR A <br />COMPLETE AND OPERATIONAL SYSTEM ARE NOT TO BE PROVIDED AS REQUIRED. <br />THE SEPARATE DIVISIONAL DRAWINGS AND SPECIFICATIONS DO NOT RELIEVE THE <br />CONTRACTOR FROM THE RESPONSIBILITY TO PROVIDE THE WORK WHICH IS <br />INDICATED ON ANY OF THE DRAWINGS OR DIVISION OF THE SPECIFICATIONS. <br />REVIEW AND COORDINATE THE SCOPE OF WORK WITH ALL SECTIONS TO ASSURE <br />A COMPLETE AND FUNCTIONAL SYSTEM IS INSTALLED. <br />3. THE DIMENSIONS AND CONDITIONS SHOWN ON THE CONTRACT DOCUMENTS ARE <br />BASED ON AVAILABLE EXISTING INFORMATION. VERIFY EXISTING CONDITIONS AND <br />DIMENSIONS TO ESTABLISH DUCT, PIPING AND EQUIPMENT CLEARANCES. NOTIFY <br />THE ARCHITECT OF ANY DEVIATIONS FROM THE CONTRACT DOCUMENTS. <br />4. NOTIFY THE ARCHITECT OR HIS AUTHORIZED REPRESENTATIVE OF ANY DAMAGE <br />TO THE EXISTING INSTALLATION BEFORE PROCEEDING WITH WORK. <br />5. CONSTRUCTION SHALL COMPLY WITH LOCAL BUILDING CODES ADOPTED AT TIME <br />OF PERMIT APPLICATION, AND AS REFERENCED IN THE CODE CRITERIA ON THIS <br />SHEET. <br />6. SUBMIT FULL SHOP DRAWINGS OF ALL EQUIPMENT AND MATERIALS (WHETHER OR <br />NOT IT IS EXACTLY AS SPECIFIED) FOR REVIEW. WHERE MANUFACTURERS ARE <br />LISTED IN THE PROJECT MANUAL, ONE OF THOSE MANUFACTURERS SHALL BE <br />PROVIDED UNLESS A REQUEST FOR SUBSTITUTION HAS BEEN SUBMITTED PRIOR <br />TO BID AND THE MANUFACTURER SUBSEQUENTLY IS LISTED AS AN ACCEPTABLE <br />MANUFACTURER IN AN ADDENDUM. PARTIAL SUBMITTALS WILL NOT BE ACCEPTED <br />FOR REVIEW AND APPROVAL. INSTALL AND TEST ALL EQUIPMENT AND <br />MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND <br />RECOMMENDATIONS. FOR ALL EQUIPMENT, WHICH HAS BEEN SCHEDULED <br />DIRECTLY ON THE DRAWINGS, PROVIDE WITHIN THE SUBMITTAL, A PERFORMANCE <br />SCHEDULE FOR THE PROPOSED EQUIPMENT IN THE SAME FORMAT AS INCLUDED <br />ON THE CONTRACT DOCUMENTS. BIND SHOP DRAWINGS/CATALOG-CUTS IN <br />THREE RING BINDERS WITH A TITLE SHEET AND IDENTIFICATION ON FRONT AND <br />SIDE OF THE BINDER. SUBMIT DRAWINGS AND CUT SHEETS FOR ALL PRODUCTS <br />&L AT ONE TIME. INDEX ALL ITEMS TO THE PROJECT MANUAL OR DRAWINGS <br />AS APPLICABLE. SHOP DRAWINGS THAT DEVIATE FROM THE REQUIREMENTS OF <br />THE CONTRACT DOCUMENTS SHALL LIST ALL DIFFERENCES IN A COVER LETTER <br />ATTACHED TO FRONT OF THE SUBMITTAL. <br />7. DUCTWORK, AIR DEVICES AND OTHER ITEMS OF THE AIR DISTRIBUTION SYSTEM <br />SHALL BE SUPPORTED DIRECTLY FROM THE BUILDING STRUCTURE AND NOT FROM <br />THE CEILING OR CEILING SUSPENSION SYSTEM. COORDINATE LOCATION OF AIR <br />DEVICES, WALLCAPS, ROOFCAPS AND LOUVERS WITH ELECTRICAL, ARCHITECTURAL, <br />AND PLUMBING WORK. AIR DEVICES SHALL BE SUPPORTED FROM THE BUILDING <br />STRUCTURE FROM AT LEAST TWO POINTS. <br />8. ALL DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH THE <br />LATEST EDITION OF "SMACNA" DUCT CONSTRUCTION STANDARDS AND COMPLY <br />WITH THE LATEST "NFPA" 90A REQUIREMENTS. ALL DUCTWORK SHALL BE LEAK <br />TESTED IN ACCORDANCE WITH SMACNA AND ASHRAE STANDARDS, AND BE <br />COMPLETED BY THE TEST AND BALANCE COMPANY. DUCTS WITH A LEAKAGE <br />RATE MORE THAN 2% WILL BE REJECTED. <br />FABRICATE DUCTWORK TO THE FOLLOWING DUCT PRESSURE CLASS: <br />DUCT PRESSURE CLASS OPERATING PRESSURE <br />1 /2" W.G. UP TO 1 /2" W.G. <br />1 " W.G. OVER 1 /2" UP TO 1 " W.G. <br />2" W.G. OVER 1 " UP TO 2" W.G. <br />DUCTWORK SHALL BE SEALED T0: <br />APPLICABLE DUCT PRESSURE CLASS SEAL CLASS <br />2" W.G. AND BELOW C <br />9. ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. <br />10. SUPPLY, RETURN, EXHAUST, AND OUTSIDE AIR DUCTWORK SHALL BE GALVANIZED <br />SHEET METAL. SEAL ALL DUCT JOINTS WITH HARDCAST. ALL SUPPLY, RETURN <br />AND OUTSIDE AIR DUCTS SHALL BE INSULATED WITH BLANKET TYPE INSULATION <br />WITH VAPOR BARRIER (MINIMUM R = 6.0). DUCT INSULATION SHALL BE LABELED <br />AND MARKED AT REQUIRED INTERVALS PER THE FLORIDA BUILDING CODE, <br />SECTION 604. SEAL TAPED INSULATION JOINTS WITH HARDCAST. <br />11. ALL VOLUME DAMPERS SHALL BE OPPOSED BLADE TYPE. PROVIDE A ONE FOOT <br />LONG PLASTIC STRIP OF MATERIAL FROM ALL DAMPER HANDLES TO ASSIST TEST <br />AND BALANCE AGENCY IN IDENTIFYING ALL DAMPERS. IN AREAS WHERE THE <br />FINAL DAMPER INSTALLATION PROHIBITS ACCESS FOR TEST AND BALANCE, <br />PROVIDE MANUAL REMOTE CABLE CONTROLS EQUAL TO YOUNG REGULATOR <br />MODEL 830ACC/270-896. ACCESS TO END OF CABLE TO BE FLUSH IN CEILING <br />NEATLY CONCEALED WITH THREADED CAP. PAINT CAP TO MATCH CEILING <br />COLOR. INDICATE LOCATIONS OF ALL CAPS ON DUCTWORK COORDINATION <br />DRAWINGS AND OBTAIN WRITTEN APPROVAL FROM ARCHITECT/ENGINEER PRIOR TO <br />INSTALLATION. REMOVE MATERIAL FROM EXPOSED DUCT DAMPERS AFTER <br />SUBSTANTIAL COMPLETION. <br />12. ALL DUCT ELBOWS SHALL INCLUDE AIR FLOW DIRECTIONAL VANES AS PER <br />"SMACNA" DUCT CONSTRUCTION STANDARDS. SPUTTER VANES SHALL BE <br />PROVIDED IN ALL ELBOWS AND DUCT OFFSETS WITH ANGLES BETWEEN 15 DEGREE <br />AND 90 DEGREES AS PER FIG. 2-5 OF THE SMACNA MANUAL. 90 DEGREE <br />ELBOWS SHALL HAVE TURNING VANES. <br />13. PROVIDE CONICAL SPIN -IN FITTINGS AT ALL CONNECTIONS OF ROUND SHEET <br />METAL OR FLEXIBLE SUPPLY AIR DUCTS TO RIGID RECTANGULAR DUCT. <br />14. ALL PIPING AND/OR DUCTWORK MUST BE INSTALLED 6" AWAY FROM ANY FIRE <br />RATED WALL. <br />15. FLEXIBLE DUCTS SHALL BE FACTORY INSULATED WITH 3/4" THICK GLASS FIBER <br />AND INCLUDE A VINYL VAPOR JACKET AND HELIX STEEL WIRE. "THERMAFLEX" <br />TYPE MAKE OR APPROVED EQUAL. FLEXIBLE DUCT SHALL BE ATTACHED WITH <br />"THERMAFLEX" WRAP LOCK SERIES 0902 CLAMPS. MAXIMUM LENGTH OF <br />FLEXIBLE DUCT SHALL BE 6'-0". <br />16. SMOKE AND HIGH TEMPERATURE PROTECTION OF MECHANICAL AIR DISTRIBUTION <br />SYSTEMS. <br />A. DUCT MOUNTED SMOKE DETECTORS SHALL BE FURNISHED AND WIRED UNDER <br />DIVISION 16 (ELECTRICAL) AT LOCATIONS INDICATED ON THE PLANS AND AS <br />HEREIN SPECIFIED. DUCT DETECTORS SHALL COMPLY WITH UL 268A. <br />B. MECHANICAL PLANS INDICATE THE APPROXIMATE LOCATION OF DUCT DETECTORS. <br />ASSIST THE SMOKE DETECTOR INSTALLER IN LOCATING AND INSTALLING THE <br />DETECTORS IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. <br />WHEN RECOMMENDED CLEARANCES CAN NOT BE MAINTAINED, SIMULATE A SMOKE <br />AIR FLOW TEST OF EACH DEVICE AND PROVIDE A COPY OF THE FIELD TEST TO <br />THE OWNER'S REPRESENTATIVE. <br />C. PROVIDE A MINIMUM 12" X 12" INSULATED AND DOUBLE GASKETED DUCT ACCESS <br />DOOR ADJACENT TO EACH DUCT MOUNTED SMOKE DETECTOR TO FACILITATE <br />INSPECTION OF DUCT DETECTOR TUBES. ACCESS DOOR SHALL NOT REQUIRE <br />TOOLS TO BE OPENED. <br />17. PROVIDE P-TRAPS AS PER DETAIL AT ALL CONDENSATE DRAIN LINE <br />CONNECTIONS. SLOPE DRAIN LINES TOWARD THE POINT OF DISCHARGE (MIN <br />1/8"/FOOT). INSULATE CONDENSATE DRAIN LINES LOCATED WITHIN THE BUILDING <br />ENVELOPE WITH 3/4" THICK SEAMLESS CLOSED CELL RUBBER PIPE INSULATION. <br />CONDENSATE DRAIN LINES TO BE PVC. LINES SHALL BE ONE DIAMETER LARGER <br />THAN THE UNIT DRAIN CONNECTION, BUT NOT LESS THAN 3/4 INCH. PROVIDE <br />CLEANOUTS AT ALL CHANGES OF DIRECTION. THE FOLLOWING MINIMUM PIPE <br />SIZES SHALL BE USED: <br />EQUIPMENT CAPACITY MINIMUM PIPE DIAMETER <br />UP TO 20 TONS 3/4" <br />18. PROVIDE FLEXIBLE CONNECTIONS BETWEEN ALL AIR MOVING APPARATUS AND <br />DUCTWORK. RECOMMENDED WIDTH IS 4". <br />19. WHERE INDICATED ON DRAWINGS AND/OR EQUIPMENT SCHEDULES EXTERNAL <br />STATIC PRESSURE IS DEFINED AS NOT INCLUDING LOSSES DUE TO UNIT MOUNTED <br />FILTER(S), RETURN AIR PLENUM OR MIXING BOXES. THOSE LOSES SHALL BE <br />PART OF THE EQUIPMENT INTERNAL LOSSES SAME AS THOSE CAUSED BY COILS, <br />CABINET, ETC. <br />20. PROVIDE REINFORCED 4" THICK CONCRETE PAD UNDER CONDENSING UNITS. PAD <br />SHALL BE SIZED TO ACCOMMODATE THE REQUIRED SERVICE CLEARANCES AND/OR <br />EXTEND A MINIMUM OF ONE FOOT (1'-0") PAST UNIT IN ALL DIRECTIONS AND <br />PLACE THE CONDENSING UNIT BASE A MINIMUM OF 4" ABOVE ADJOINING GRADE. <br />PROVIDE 1" NEOPRENE PADS UNDER CONDENSING UNIT. SECURE CONDENSING <br />UNIT(S) TO PAD USING ONE INCH WIDE 16 GAGE STAINLESS STEEL STRAPS AND <br />STAINLESS STEEL SCREWS, AT A MAXIMUM 18 INCHES ON CENTER, ON ALL SIDES <br />OF THE UNIT. <br />21. ROOF MOUNTED EQUIPMENT SHALL BE SECURED TO THE CURB USING ONE INCH, <br />16 GAGE STAINLESS STEEL STRAPS AND STAINLESS STEEL SCREWS. THE CURBS <br />SHALL BE SECURED TO THE STRUCTURE AS DETAILED BY THE ARCHITECT OR <br />STRUCTURAL ENGINEER. <br />22. PROVIDE PAINTED GALVANIZED EXPANDED METAL GRILLE OVER ALL CONDENSER <br />COILS. <br />23. ALL EQUIPMENT (FANS, AIR HANDLERS, CONDENSING UNITS, ETC.) SHALL BE <br />LABELED WITH PLASTIC SIGNS, LAMINATED, ENGRAVED: 1 /8" THICK BLANKS FOR <br />SIGNS SHALL BE A MINIMUM OF 1 3/4" HIGH, WITH 1" HIGH LETTERS. LENGTH OF <br />THE SIGN SHALL BE THE SUM OF THE LETTERS/NUMBERS PLUS 3/4" EACH END. <br />SIGNS DESIGNATED FOR INSTALLATION ON THE OUTSIDE, IN OPEN AREAS, OR <br />LOCATED IN A PROTECTED AREA THAT IS SUBJECT TO DIRECT SUNLIGHT, SHALL <br />BE UV RATED, DESIGNATED AND MANUFACTURED TO BE EXPOSED TO THE <br />ELEMENTS. SUBMITTAL DATA INDICATING THE ABOVE WILL BE REQUIRED. LABELS <br />SHALL ALSO INCLUDE THE ROOM NUMBER, CORRESPONDING AIR HANDLER <br />LOCATION OR AREA SERVED TO ASSIST IN THE DETERMINATION OF THE SERVICE <br />LOCATION OF SAID EQUIPMENT. <br />24. ALL WALL MOUNTED TEMPERATURE SENSORS SHALL BE INSTALLED AT A CENTER <br />LINE ELEVATION OF 4'-0" ABOVE FINISHED FLOOR UNLESS OTHERWISE NOTED ON <br />DRAWINGS. LOCATION OF THE WALL MOUNTED THERMOSTAT SHALL BE <br />COORDINATED WITH THE OTHER TRADES FOR A NEAT APPEARANCE. FINAL <br />LOCATION OF THERMOSTAT SHALL BE SUBJECT TO THE APPROVAL OF THE <br />ARCHITECT OR HIS REPRESENTATIVE IN THE FIELD. WHEN INSTALLED ON <br />EXTERIOR WALLS, PROVIDE AN INSULATED SUB -BASE. <br />25. RETAIN THE SERVICES OF A NEBB AND/OR AABC CERTIFIED TEST AND BALANCE <br />AGENCY TO PERFORM FINAL TESTING AND BALANCING OF ALL HVAC SYSTEMS. <br />RECORD ALL DATA ON STANDARD "AABC" OR OTHER APPROVED FORMS, AND <br />SUBMIT TO THE ARCHITECT FOR REVIEW. <br />26. PROVIDE SCHEDULE 40 STEEL PIPE SLEEVES FOR REFRIGERANT AND CONDENSATE <br />DRAIN LINES PENETRATING EXTERIOR WALLS. NEATLY SEAL VOIDS AROUND <br />PIPING WITH A WEATHER TIGHT PERMANENT NON -SHRINKING SEALANT. <br />27. REFRIGERANT LINES SHALL BE SIZED AS PER THE EQUIPMENT MANUFACTURER'S <br />RECOMMENDATIONS. PROVIDE SIZING AND ACCESSORY DATA WITH THE <br />EQUIPMENT PACKAGE SUBMITTAL. PIPING IS TO BE FILLED WITH DRY NITROGEN <br />WHILE SOLDERING. TEST, CLEAN, AND DEHYDRATE PIPES AND PROVIDE CHARGE <br />OF REFRIGERANT AS PER EQUIPMENT MANUFACTURER'S RECOMMENDATION. <br />PROVIDE ALL NECESSARY VALVES, TRAPS, FILTER/DRYERS, SIGHT GLASS, ETC. <br />AS REQUIRED FOR A COMPLETE AND READY TO OPERATE INSTALLATION. <br />INCLUDE ACCESSIBLE SERVICE FITTINGS. <br />28. ALL REFRIGERANT PIPING SHALL BE INSULATED WITH 3/4" THICK SEAMLESS <br />CLOSED CELL RUBBER PIPE INSULATION. INSULATION EXPOSED TO THE OUTSIDE <br />ENVIRONMENT SHALL BE PAINTED WITH TWO COATS OF UV -RESISTANT WHITE <br />ARMAFLEX PAINT. <br />29. EQUIPMENT SERVICE ACCESS <br />PROVIDE ADEQUATE SERVICE SPACE AROUND AIR HANDLING UNITS, ELECTRIC <br />HEATERS AND THE PULL SIDE OF FILTERS. <br />SERVICE AREA SHALL BE CLEAR OF DUCTS, PIPES, CONDUITS, WALL STUDS, <br />CEILING HANGERS, AND ANY OTHER CONSTRUCTION APPURTENANCE. <br />30. PROVIDE A 26 GA GALVANIZED SHEET METAL PLATE TO COVER PIPING ON WALL. <br />PAINT TO MATCH WALL COLOR AND AS DIRECTED BY THE ARCHITECT. <br />31. ROOFING WORK IN THESE BUILDINGS SHALL MATCH EXISTING AND WORK SHALL <br />BE PERFORMED BY AN AUTHORIZED ROOFING CONTRACTOR. ON BONDED ROOFS, <br />ALL ROOFING WORK REQUIRED FOR THE INSTALLATION OF THE NEW UNITS SHALL <br />BE RECERTIFIED BY COMPANY HOLDING THE BOND ON THE ROOF. THE ROOFING <br />CONTRACTOR TO REVIEW THE OWNER(S) AND BONDING COMPANY(S) POLICIES, <br />ROOF BONDING (WHEN APPLICABLE) ETC. BEFORE ANY ROOFING WORK IS <br />COMPLETED, REMOVE ALL EXISTING ROOF EQUIPMENT SUPPORTS DOWN TO THE <br />STRUCTURE THAT WILL NOT BE USED ON THE NEW INSTALLATION. <br />32. ALL AIR HANDLING UNITS SHALL BE PROVIDED WITH A MINIMUM 24 GAGE <br />GALVANIZED STEEL SECONDARY DRAIN PAN. PAN SHALL BE THREE INCHES DEEP <br />AND EXTEND A MINIMUM OF FOUR INCHES PAST THE AIR HANDLER IN ALL <br />DIRECTIONS. THE PAN SHALL BE PROVIDED WITH A FLOAT SWITCH WIRED TO <br />SHUT DOWN THE SYSTEM WHEN WATER IS DETECTED. ALL COMPONENTS OF THE <br />AIR HANDLER AND PIPING SUBJECT TO CONDENSATION SHALL BE PROTECTED BY <br />THE PAN. <br />33. PROVIDE A MANUAL AND A MOTORIZED DAMPER IN ALL OUTDOOR AIR INTAKE <br />DUCTS. MOTORIZED DAMPER SHALL BE WIRED TO OPEN AFTER A ONE HOUR <br />DELAY (ADJUSTABLE) WHEN AIR HANDLER IS ENERGIZED AND TO CLOSE <br />WHENEVER AIR HANDLER IS DE -ENERGIZED, OR AS DETAILED IN THE CONTROLS <br />DRAWINGS AND SEQUENCES. ALL EXHAUST AIR FANS SHALL BE INTERLOCKED <br />WITH THE MOTORIZED DAMPER SUCH THAT THE FANS OPERATION IS PROHIBITED <br />IF THE OUTSIDE AIR DAMPER IS CLOSED. REFER TO CONTROL SECTIONS FOR <br />FURTHER REQUIREMENTS AND SCHEDULING. THE MANUAL DAMPER IN THE <br />OUTSIDE AIR INTAKE DUCT SHALL BE USED FOR BALANCING THE OUTDOOR AIR <br />FLOW. <br />34. ACCESS PANELS THAT MAY BE REQUIRED FOR INSPECTION OF DUCTWORK, PIPING, <br />DUCT MOUNTED DEVICES OR PIPE MOUNTED DEVICES SHALL BE PROVIDED. <br />REFER TO THE ARCHITECTURAL CONTRACT DOCUMENTS FOR DOOR <br />SPECIFICATIONS. <br />35. ALL NEW DUCTWORK SHALL NOT BE STORED IN UNCLEAN AREAS. PROTECT ALL <br />DUCTWORK FROM DUST AND DEBRIS WHILE IT IS STORED ON SITE. WHILE UNDER <br />CONSTRUCTION, ALL INSTALLED DUCTWORK SHALL BE TEMPORARILY SEALED WITH <br />VISQUEEN PRIOR TO TEST AND BALANCE IN ORDER TO LIMIT ACCUMULATION OF <br />CONSTRUCTION DUST INSIDE DUCTWORK SYSTEM. <br />CODE CRITERIA <br />NOTE: <br />ALL CODES SHALL COMPLY WITH THE FLORIDA STATUES 69A-3.012 AND THE STATE <br />FIRE MARSHALLS RULE THIS LIST IS NOT INCLUSIVE OF ALL CODES AND <br />STANDARDS THAT MAY OR MAY NOT APPLY TO THIS PROJECT. <br />*FLORIDA BUILDING CODE (FBC) 2010 - ALL SECTIONS <br />*FLORIDA ENERGY EFFICIENCY CODE - FBC 2010 FLORIDA ENERGY CODE <br />SOFTWARE: ENERGYGAUGE SUMMIT VERSION 4.00 <br />*FLORIDA FIRE PREVENTION CODE 2010 <br />*FLORIDA AMERICANS WITH DISABILITIES ACCESSIBILITY IMPLEMENTATION ACT <br />(2010) AS DESCRIBED IN ACCESSIBILITY REQUIREMENTS MANUAL, DEPARTMENT <br />OF COMMUNITY AFFAIRS <br />NATIONAL FIRE PROTECTION ASSOCIATION (NFPA): <br />*NFPA-70 (2008) NATIONAL ELECTRICAL CODE <br />*NFPA-72 (2007) NATIONAL FIRE ALARM CODE <br />*NFPA-90A (2009) STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND <br />VENTILATING SYSTEMS <br />*NFPA-90B (2009) STANDARD FOR THE INSTALLATION OF WARM AIR HEATING <br />AND AIR-CONDITIONING SYSTEMS <br />AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING <br />ENGINEERS. INC. (ASHRAE): <br />*ASHRAE GUIDELINE 4-2008 - PREPARATION OF OPERATING AND MAINTENANCE <br />DOCUMENTATION FOR BUILDING SYSTEMS <br />*ASHRAE STANDARD 6Z1-2010 AND APPROVED ADDENDA - VENTILATION FOR <br />ACCEPTABLE INDOOR AIR QUALITY <br />*ASHRAE STANDARD 126-2000 - METHOD OF TESTING HVAC AIR DUCTS <br />HVAC DESIGN CRITERIA <br />LOCATION <br />ZEPHYRHILLS, <br />FLORIDA <br />OUTDOOR 'F <br />TEMP DB/WB <br />SUMMER INDOOR <br />TEMP 'F DB B <br />WINTER INDOOR <br />TEMP 'F DB <br />SUMMER <br />WINTER <br />75/63 <br />70 <br />91/80 <br />36 <br />FLOOR INSULATION <br />R=0 <br />WALL INSULATION <br />R=13 <br />LOAD <br />ROOF INSULATION <br />R=30 <br />CRITERIA <br />WINDOW TYPE <br />U-VALUE = 05 SHADING COEFF. = 0.5 <br />NOTES <br />1. THE NOTES SHOWN ON THIS SHEET APPLY TO GENERAL CONDITIONS OF HEATING, <br />VENTILATING AND AIR CONDITIONING WORK REQUIRED FOR THIS PROJECT. <br />2 SPECIFICATIONS, PROJECT MANUALS AND DRAWINGS, REFER TO THIS SHEET FOR <br />APPLICABLE REFERENCES. <br />3. THE DESIGN DRAWINGS OF ALL CATEGORIES AND TRADES (ARCHITECTURAL, <br />STRUCTURAL, PLUMBING, MECHANICAL, HEATING, VENTILATING AND AIR <br />CONDITIONING AND ELECTRICAL) AND ALL SPECIFICATIONS AND SHOP DRAWINGS <br />MUST BE COORDINATED AND BE VIEWED IN CONNECTION AND CONJUNCTION <br />WITH EACH OTHER TO INSURE THE PROPER LOCATION OF ALL DEVICES AND <br />EQUIPMENT. MAKE PARTICULAR NOTE OF LOCATIONS AND DIMENSIONS SHOWN <br />ON THE ARCHITECTURAL FLOOR PLANS AND ELEVATIONS. <br />4. TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS <br />COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE <br />FIRE -SAFETY STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN <br />ACCORDANCE WITH SECTION 105.13.4.4 OF THE FLORIDA BUILDING CODE AND 633 <br />FLORIDA STATUTES. <br />DRAWING INDEX <br />M-0 HVAC LEGEND, NOTES, AND SYMBOLS <br />M-1 HVAC FLOOR PLAN <br />M-2 HVAC DETAILS <br />M-3 HVAC SCHEDULES <br />M-4 HVAC SCHEDULES AND CONTROLS <br />CONSULTING ENGINEERING <br />ASSOCIATES, INC. <br />SM WNN HIGHWAY <br />TAMPA. FLORIDA 33626 <br />PHONE: (613) 448-0=5 <br />® OOOD 62 <br />PROJECT NUMBER: 14021 <br />COPYRIGHT ® 2014 <br />CONSULTING ENGINEERING ASSOCIATES, INC. <br />'Wily 'Fil <br />1 <br />architect <br />SONIA FUEREDI DESIGN ' <br />2860 WILTSHIRE DRIVE , <br />DECATUR, GA 30030 ; <br />plumbing & electrical <br />HUGO MADRIGAL, PE <br />4911 MOLAKAI DR <br />NAPLES, FL 33412 <br />mechanical <br />CONSULTING ENG. <br />ASSOCIATES, INC. <br />8365 Gunn Highway <br />Tampa, Florida 33626 <br />RTD <br />general contractor <br />RTD CONSTRUCTION, Inc <br />5344 9th Street <br />ZeDhvrhills. Florida 33542 <br />Oz <br />UILL <br />LL <br />J <br />J <br />z <br />Z <br />00_ <br />W <br />Q <br />U <br />N <br />> <br />0 <br />W <br />z <br />ZILU <br />- <br />W <br />W <br />Q <br />Z <br />= <br />W <br />O <br />c C <br />� <br />UUz <br />LL <br />0 <br />M <br />LL <br />O <br />i- <br />0 <br />00 <br />M <br />PROJECT NO: 2014-001 <br />DATE: 04/24/14 <br />REVISIONS I <br />WELLS, III, F <br />0049347 <br />M-0 <br />