My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6042 N Gall Bllvd
Zephyrhills
>
Building Department
>
Building Plans
>
6042 N Gall Bllvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2025 4:30:09 PM
Creation date
2/18/2025 4:03:14 PM
Metadata
Fields
Template:
Building Plans
Street #
6042
Location
N Gall Blvd
Contractor
Purdy-Muroff Architecture, Inc
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />EXISTING <br />PANEL AP4 <br />I <br />E ISTING <br />E ECTRICAL <br />M P, AP1, AP2 <br />D AP3 <br />6-7 <br />I <br />V-7 <br />I <br />i i li <br />i�I I� <br />GENERAL NOTES: <br />1. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2017 NATIONAL ELECTRICAL CODE <br />AND SHALL ALSO COMPLY WITH ALL APPLICABLE RULES AND REGULATIONS OF LOCAL <br />AND STATE LAWS AND ORDINANCES. <br />2. CONTRACTOR SHALL MAKE A THOROUGH EXAMINATION OF THE SITE AND THE <br />CONTRACT DOCUMENTS. NO CLAIM FOR EXTRA COMPENSATION WILL BE <br />RECOGNIZED IF DIFFICULTIES ARE ENCOUNTERED WHICH AN EXAMINATION OF SITE <br />CONDITIONS AND CONTRACT DOCUMENTS PRIOR TO EXECUTING CONTRACT WOULD <br />HAVE REVEALED. <br />3. ELECTRICAL CONTRACTOR SHALL ARRANGE FOR ALL NECESSARY PERMITS, <br />LICENSES, UTILITY COORDINATION AND INSPECTIONS AS REQUIRED BY THE CITY OR <br />UTILITY COMPANY. OWNER WILL PAY FEES. CONTRACTOR IS RESPONSIBLE FOR ALL <br />EQUIPMENT REQUIRED BY UTILITY COMPANY AND SHOULD INCLUDE NECESSARY <br />COSTS IN BID. <br />4. CONTRACTOR SHALL LEGIBLY MARK-UP A SET OF 24"x36" DRAWINGS TO REFLECT <br />AS -BUILT CONDITIONS AND TURN OVER TO THE ARCHITECT. <br />5. PANELBOARD MANUFACTURER SHALL PROVIDE ARC -FLASH WARNING LABELES FOR <br />MDP AND ALL BRANCH PANELBOARDS IN ACCORDANCE WITH NEC 110. <br />GROUNDING: <br />1. THE INTERIOR ELECTRICAL SYSTEMS SHALL BE COMPLETELY AND EFFECTIVELY <br />GROUNDED AS REQUIRED BY NATIONAL ELECTRICAL CODE ALL METALLIC RACEWAYS <br />SHALL BE MECHANICALLY AND ELECTRICALLY SECURE AT ALL JOINTS AND AT ALL <br />BOXES, CABINETS, FITTINGS AND EQUIPMENT. <br />OUTLET BOXES/DEVICES: <br />1. ALL OUTLET BOXES SHALL BE RIGIDLY MOUNTED AND SHALL BE EQUIPPED WITH <br />SUITABLE SCREW FASTENED COVERS. OPEN KNOCKOUTS OR HOLES IN BOXES <br />SHALL BE PLUGGED WITH SUITABLE BLANKING DEVICE. <br />2. OUTLET BOXES SHALL BE 4 INCH SQUARE x 2-1/8" DEEP. OUTLET BOXES LOCATED <br />ABOVE THE CEILING SHALL BE LEGIBLY IDENTIFIED WITH BRANCH CIRCUIT NUMBER <br />OF CIRCUIT TERMINATED WITHIN BY MEANS OF BLACK PERMANENT MARKER. <br />SWITCHGEAR: <br />1. PANELBOARD DIRECTORY CARDS SHALL BE TYPEWRITTEN WITH ACCURATE AND <br />CURRENT INFORMATION BY THE CONTRACTOR AT THE END OF CONSTRUCTION. <br />__..._._ _ . <br />TP <br />AP4-40 <br />I � O <br />s i I <br />j1_.- I] <br />II <br />I i � <br />f <br />i <br />j <br />TP <br />�....._..... 6 6 <br />AP1-13 6 <br />I , 8207.09 E 1 <br />- 215.07 1 E1 <br />; � E <br />?I <br />JEW <br />EXISTING I i <br />PANEL LP <br />WIRE/RACEWAY: <br />1. ALL CONDUCTORS SHALL BE COPPER, CONDUCTOR INSULATION SHALL BE DUAL TYPE <br />THHN/THWN 75°C. (167°F) FOR DRY, DAMP, AND WET LOCATIONS. CONDUCTOR <br />INSULATION WITH SINGLE TYPE MARKING THHN 90°C (194°F) MAY BE USED FOR DRY <br />LOCATIONS ONLY. ALL CONDUCTORS SHALL BE COLOR CODED AS REQUIRED BY NEC <br />AND FURTHER IDENTIFIED AND CODED AS SPECIFIED HEREINAFTER. COLOR CODING <br />SHALL BE BY MEANS OF COLORED INSULATING MATERIAL, COLORED BRAID OR <br />JACKET OVER THE INSULATION OR BY MEANS OF SUITABLE COLORED, PERMANENT, <br />NON -AGING, INSULATING TAPE APPLIED TO CONDUCTORS AT EACH CABINET OR <br />JUNCTION POINT. THE COLOR CODING SHALL BE ACCOMPLISHED AS THE <br />CONDUCTORS ARE INSTALLED. THE FOLLOWING SYSTEMS OF COLOR CODING SHALL <br />BE STRICTLY ADHERED TO: <br />A) GROUND LEADS: GREEN <br />B) 120/208 VOLT UNGROUNDED PHASE WIRES: <br />PHASE A: BLACK <br />PHASE B: RED <br />PHASE C: BLUE <br />NEUTRAL: WHITE <br />THE COLOR CODE ASSIGNED TO EACH PHASE WIRE SHALL BE CONSISTENTLY <br />FOLLOWED THROUGHOUT <br />2. ALL BRANCH CIRCUIT WIRING TO 120 VOLT LIGHTING FIXTURES AND RECEPTACLES <br />SHALL BE AS FOLLOWS. <br />MAXIMUM LENGTH 85FT. - 2 #12, 1 #12 E.G. <br />MAXIMUM LENGTH 140FT. - 2 #10, 1 #10 E.G. <br />MAXIMUM LENGTH 225FT. - 2 #8, 1 #8 E.G. <br />MAXIMUM LENGTH 350FT. - 2 #6, 1 #6 E.G. <br />3. UNLESS OTHERWISE NOTED ALL CONDUCTORS SHALL BE RUN IN THIN WALL CONDUIT <br />AND THIN WALL CONDUIT SHALL BE UNDERWRITERS' APPROVED GALVANIZED <br />ELECTRICAL METALLIC TUBING. COUPLINGS AND CONNECTORS SHALL BE STEEL <br />SET -SCREW TYPE, ZINC OR CADMIUM PLATED. MC CABLE MAY BE USED WHERE <br />CONCEALED IN WALLS. <br />4. ALL RACEWAYS SHALL BE PROPERLY ALIGNED, GROUPED, AND SUPPORTED BY <br />MECHANICAL TYPE 'CADDY CLIPS AT INTERVALS NOT EXCEEDING 8 FEET. <br />5. ALL RACEWAYS WITH NO. 10 OR 12 AWG PHASE CONDUCTORS FOR RECEPTACLES, <br />LIGHTING FIXTURES AND SIMILAR CIRCUITS SHALL BE PROVIDE WITH A PARITY SIZED <br />GREEN EQUIPMENT GROUND CONDUCTOR. GROUND CONDUCTOR SHALL BE <br />INSTALLED IN ENTIRE RACEWAY SYSTEM INCLUDING WALL SWITCHES AND FLEXIBLE <br />CONDUIT TO LIGHT FIXTURES. EQUIPMENT GROUND CONDUCTOR SIZES FOR <br />CIRCUITS WITH PHASE CONDUCTORS LARGER THAN NO. 12 AWG ARE INDICATED ON <br />DRAWINGS. GROUND CONDUCTORS SHALL BE CONNECTED TO GROUND BUSS IN <br />PANELBOARDS. <br />6. RACEWAY PENETRATIONS OF FIRE RATED WALLS AND/OR FLOORS SHALL BE SEALED <br />TO MAINTAIN INTEGRITY OF CONSTRUCTION. ALL PRODUCTS, MATERIALS AND <br />METHODS OF INSTALLATION SHALL BE UL APPROVED AND MEET NFPA. <br />7. ALL ELECTRICAL CONDUITS SHALL BE CONCEALED IN WALLS UNLESS AS -BUILT <br />CONDITIONS PROHIBITS. GC TO NOTIFY ARCH/ACM OF AS -BUILT CONDITIONS. <br />004.20 E7 <br />1� <br />i I 039.15 E3 <br />041.09 1 E1 <br />j 216.00 E2 <br />------- 216.00 216.00 E3 <br />213.00 E11 <br />7 <br />R�, , <br />POWER PLAN <br />SCALE: 1/4" = V-0" <br />TP <br />210.00 E10 <br />�215.00�lEl210 <br />TP <br />TP <br />TP <br />0 <br />O <br />U <br />o <br />f yWy <br />I W <br />i Nri w <br />r <br />s <br />/mow <br />luj <br />`.� It � .. •.- <br />re <br />f I <br />vsr (3 . B <br />I <br />X8021.11 <br />E1 8181.01 E2 <br />E2 8203.02 E2 ( L <br />El 8205.11 E2 <br />3 E2 8216.00 E2 <br />E2 8216.00 E7) <br />E2 <br />Lm <br />_ 207.09 E 1 <br />207.10 1 E1 - e <br />`g <br />8025.02 E2 8039.09 E 1 <br />i <br />ram- _ -_ � �"` 1 I � ; �\ � E • <br />3 <br />009.15 E1 8023.05 E2 8216.00 1 E2- a o <br />216.00 E2 8023.05 E2 8216.00 E7 > <br />246. E7 8024.01 E1ju <br />8217.13 E2 © � <br />217.00 E`t� - 8215. 8 E1 8219.00 E7 <br />ca <br />3021.Q1 E2 8215.98 2 -821 E8 <br />W21.98 82 �5 9 E2 7000.12 --- <br />__ I <br />_ ..._10 oil <br />O KEYNOTE LEGEND <br />1. RACEWAY KIT PROVIDED WITH COUNTER, INSTALLED BY EC. <br />a <br />2. IF OPTIONAL TABLE TRACKER SYSTEM IS TO BE USED. IF USED, PROVIDE 2 #12 AND 1 <br />#12 GROUND TO AVAILABLE SPARE 20A/1 P BREAKER. CONNECT CIRCUIT TO (3) 5-20R <br />RECEPTACLES, (1) RECEPTACLE FOR MODEM/GATEWAY (TYPICALLY LOCATED BEHIND <br />VALENCE AT 7'-9" AFF), (1) RECEPTACLE FOR LOCATOR CHARGER (TYPICALLY <br />LOCATED IN MANAGERS OFFICE) AND (1) RECEPTACLE FOR MONITOR (TYPICALLY <br />LOCATED AT PICKUP COUNTER). COORDINATE EXACT LOCATION(S) IN THE FIELD. <br />3. COORDINATE LOCATION AND REQUIREMENTS OF HAPPY MEAL DISPLAY WITH DECOR <br />COMPANY. TIE INTO LIGHTING CIRCUIT SERVING THIS AREA, 2 #12 AND 1 #12 E.G. IN <br />1/2' CONDUIT. <br />4. RELOCATED ORDERING KIOSK. COORDINATE EXACT LOCATION AND REQUIREMENTS <br />WITH ARCHITECT AND OWNER PRIOR TO RELOCATIONS. EXTEND CIRCUITRY AND <br />CONDUCTOR AS REQUIRED. VERIFY THAT EACH KIOSK IS POWERED BY A 1 POLE 20 <br />AMP CIRCUIT BREAKER. <br />5. COORDINATE LOCATION AND REQUIREMENTS OF FUTURE CASH HANDLER WITH <br />O <br />0 <br />DECOR COMPANY. POWER IS FED FROM ORDERING KIOSK BASE PLATE, IF NOT <br />LOCATED NEXT TO THE WALL. IF LOCATED NEXT TO TO A WALL THEN FEED FROM <br />Q. <br />_ <br />WALL POWER. <br />6. COORDINATE LOCATION AND REQUIREMENTS OF J-BOX FOR DECOR ELEMENT WITH <br />DECOR DRAWINGS. 2 #12 AND 1 #12 E.G. IN 1/2' CONDUIT. <br />7. CONNECT TO SPARE 20 AMP - 1 P, 120 VOLT BREAKER. FURNISH AND INSTALL <br />BREAKER IF A SPARE IS NOT AVAILABLE. <br />CONTRACTOR TO FIELD VERIFY CIRCUIT NUMBERS <br />AND EXACT NUMBER OF SPARES AVAILABLE. <br />SEE SHEET E3.0 <br />FOR REQUIREMENTS <br />THIS ITEM HAS BEEN ELECTRONICALLY <br />SIGNED AND SEALED BY ADAM T. <br />_ ���� <br />POWELL, PE USING A DIGITAL <br />SIGNATURE AND DATE. PRINTED COPIES <br />ENGINEERING I N r <br />OF THIS DOCUMENT ARE NOT <br />CONSIDERED SIGNED AND SEALED AND <br />I <br />DAVIS E 9942 CURRIDR. STE H., TAMPA, FL 33619 <br />THE SIGNATURE MUST BE VERIFIED ON <br />TEL (gU) <br />ANY ELECTRONIC COPIES. <br />WWW.EMERALDMEP.COM EEI PROJECT* 22072M <br />.J 11 <br />W <br />0 <br />O <br />m <br />Ld <br />cr <br />1802.31 <br />E 2. 0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.