My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6042 N Gall Bllvd
Zephyrhills
>
Building Department
>
Building Plans
>
6042 N Gall Bllvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2025 4:30:09 PM
Creation date
2/18/2025 4:03:14 PM
Metadata
Fields
Template:
Building Plans
Street #
6042
Location
N Gall Blvd
Contractor
Purdy-Muroff Architecture, Inc
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
or <br />w <br />UP TO <br />PHOTOCELL <br />ON ROOF. , <br />0 <br />LIGHTING FIXTURES <br />MANUAL SWITCH <br />(if shown on drawings) <br />LOW VOLTAGE CABLE <br />NOTES: <br />1. REFER TO LIGHTING PLAN FOR OCCUPANCY SENSOR LOCATIONS AND QUANTITIES. <br />OCCUPANCY SENSOR CONTROL DETAIL <br />LIGHTING FIXTURE SCHEDULE NOTES: <br />1. ORDER LED EXIT SIGNS WITH LETTER COLORS THAT COMPLY WITH LOCAL CODES <br />FROM SECURITY LIGHTING. <br />FOR RED LETTERS USE #PRB (UNIVERSAL) <br />FOR GREEN LETTERS USE #PGB (UNIVERSAL) <br />OR <br />IF THE ABOVE EXIT SIGNS DO NOT COMPLY WITH LOCAL CODES USE, LED SIGN <br />WITH BATTERY BACKUP, LETTER SIZE, COLOR, TYPE AND DIRECTIONAL ARROWS <br />AS REQUIRED BY THE LOCAL AUTHORITIES. <br />2. BEFORE ORDERING VERIFY WITH LOCAL MUNICIPALITY THAT THIS FIXTURE <br />COMPLIES WITH ANY LOCAL LIGHTING ORDINANCE. <br />EMERGENCY LIGHTING NOTES: <br />1. CONNECT ALL EXIT SIGNS, EMERGENCY LIGHTS, INVERTER AND NIGHT LIGHTS TO <br />THE EXISTING EXIT/EMERGENCY LIGHTING CIRCUIT. <br />2. CONNECT ALL EXIT SIGNS, EMERGENCY LIGHTS AND NIGHT LIGHTS TO ONE CIRCUIT <br />BREAKER. <br />3. LIGHTING INDICATED WITH A "NL" ARE NIGHTLIGHTS AND SHALL BE CONNECTED TO <br />THE UNSWITCHED LEG OF THE CIRCUIT. <br />4. EMERGENCY LIGHTING HAS BEEN DESIGNED PER NFPA 101 MAINTAIN 1 FC IN PATH OF <br />EGRESS. IF FIELD CONDITIONS REQUIRE ANY CHANGES TO LIGHTING DESIGN, <br />EMERGENCY LIGHTING, SHALL BE INSTALLED TO MEET THE ABOVE REQUIREMENTS. <br />LIGHTING FIXTURE SCHEDULE <br />SYMBOL <br />DESCRIPTION <br />MANUFACTURES CAT. NO. <br />VOLTAGE <br />LAMPS <br />MOUNTING <br />A <br />LED DOWN RADIUS WALL <br />SECURITY LIGHTING SYSTEMS NO: <br />14W <br />WALL MOUNT <br />E <br />WALL WASHER <br />SECURITY LIGHTING SYSTEMS NO.: <br />16 <br />CEILING RECESSED <br />® <br />SCONCE - SILVER FINISH <br />RWSC-36LED-5K-DO-U-PS <br />120 <br />RDA-60LM30-NF-S/RDA-60-H <br />120 <br />SEE LIGHTING FIXTURE SCHEDULE NOTE NO. 2 <br />LED CAN LIGHT <br />SECURITY LIGHTING SYSTEMS NO.: <br />12W <br />CEILING RECESSED <br />F <br />BLUE ROUND PENDANT <br />SECURITY LIGHTING SYSTEMS NO.: <br />12 <br />PENDANT HUNG <br />B <br />0 <br />RDA-136LM-30-FL-S/RDA-136-H <br />120 <br />® <br />7652 BLE-EQL-306-45358-1-LED <br />120 <br />REFER TO DECOR DRAWINGS FOR EXACT FIXTURE <br />TYPE <br />LED CAN LIGHT FED FROM <br />SECURITY LIGHTING SYSTEMS NO.: <br />12W <br />CEILING RECESSED <br />G <br />SLIM PENDANT GREY LARGE <br />SECURITY LIGHTING SYSTEMS NO.: <br />20 <br />CEILING RECESSED <br />BE <br />O <br />UNSWITCHED INVERTER PANEL <br />RDA- 1 36LM-30-FL-S/RDA-1 36-H <br />120 <br />6797-BPS-1388-71 <br />120 <br />NL <br />FOR USE AS NIGHT LIGHT AND <br />REFER TO DECOR DRAWINGS FOR EXACT FIXTURE <br />EMERGENCY LIGHT. <br />TYPE <br />2x4, LED LAY -IN PRISMATIC <br />SECURITY LIGHTING SYSTEMS NO. <br />44W <br />CEILING LAY -IN <br />ACRYLIC LENS <br />LCA'T24-3.`iHLG-EDU-W['-GK <br />120 <br />® <br />COMBO WITH BATTERY BACK-UP <br />120 <br />UNIT <br />2x4, LED LAY -IN PRISMATIC ACRYLIC <br />SECURITY LIGHTING SYSTEMS NO <br />44W <br />CLILJNG LAY -IN <br />EMERGENCY BATTERY AND <br />DUAL LITE <br />2-5W <br />SURFACE TO WALL <br />Ck <br />LENS FED FROM UNSWITCHED <br />LCAT24-35HLG-EDU-WP-GK <br />120 <br />X <br />2 REMOTE HEAD <br />EV4D-02L-0/EVODB <br />120 <br />OR SOFFIT <br />INVERTER PANEL FOR USE AS NIGHT <br />WHEN CONNECTED TO TWO REMOTE HEADS <br />NL <br />LIGHT AND EMERGENCY LIGHT. <br />(FOR SINGLE GANG JUNCTION BOX) <br />DELIVERY POD LED LIGHT <br />SECURITY LIGHTING SYSTEMS NO.: <br />9W <br />CEILING RECESSED <br />DENOTES EXISTING DEVICE TO <br />DP <br />LB4-61 D-30K-9-GD/IBX4QL-120 <br />120 <br />EX <br />REMAIN <br />(PROVIDED WITH DELIVERY POD) <br />D <br />2 HEAD DOUBLE GIMBALL <br />SECURITY LIGHTING SYSTEMS NO.: <br />14 <br />CEILING RECESSED <br />CEILING -MOUNTED LIGHTING INVERTER WITH MAINTENANCE FREE SEALED <br />(MULTIPLE 25 DEGREE) <br />GM2-120-LM-30-SBS <br />120 <br />O <br />LEAD CALCIUM BATTERY. <br />00 <br />REFER TO DECOR DRAWINGS FOR EXACT FIXTURE <br />SECURITY LIGHTING SYSTEMS LG1 SERIES <br />TYPE <br />INVERTER <br />MAXIMUM OF FOUR 12.5 WATT CAN LIGHTS PER INVERTER <br />DE <br />2 HEAD DOUBLE GIMBALL FED FROM <br />SECURITY LIGHTING SYSTEMS NO.: <br />14 <br />CEILING RECESSED <br />m <br />UNSWITCHED LIGHTING CIRCUIT <br />GM2-120-LM-30-SBS <br />120 <br />FOR USE AS NIGHT LIGHT AND <br />REFER TO DECOR DRAWINGS FOR EXACT FIXTURE <br />NL <br />EMERGENCY LIGHT <br />TYPE <br />f Y OF ZEPFiY HILLS- <br />);,-D;NG OFFICIAL_ <br />LIGHTING PLAN <br />SCALE: 1/4" = 1'-0" <br />GENERAL NOTES <br />1. EC SHALL FIELD VERIFY THAT ALL LIGHT FIXTURES SHOWN ON THIS PLAN DO NOT <br />OBSTRUCT OR CONFLICT WITH THE WORK OF OTHER TRADES. IF A DISCREPANCY IS <br />FOUND, THE EC SHALL IMMEDIATELY NOTIFY THE GC BEFORE THE INSTALLATION OF <br />SUCH FIXTURE(S)_. <br />2. IF PC-POS CASH REGISTER SYSTEM IS INSTALLED, RELOCATE FIXTURES ABOVE <br />FRONT COUNTER TO AVOID GLARE ON THE CASH REGISTER SCREENS. INSTALL <br />CABLE WHIP TO FIXTURES SO THAT FIXTURE CAN BE RELOCATED FOUR FEET <br />WITHOUT DISCONNECTING CABLE WHIP. <br />3. THE USE OF "MC" CABLE WHERE PERMITTED BY LOCAL CODES WILL BE ALLOWED FOR <br />ALL WIRING TO THE LIGHT FIXTURES. "ROMEX" & "BX" ARE NOT ACCEPTABLE. <br />4. LIGHTING FIXTURES AND LAMPS HAVE BEEN CHOSEN TO ACHIEVE MAXIMUM ENERGY <br />CONSERVATION WHILE MAINTAINING ADEQUATE LEVELS OF ILLUMINATION. LAMP <br />SPECIFICATIONS MUST BE STRICTLY FOLLOWED. ANY DEVIATION FROM LAMP <br />SPECIFICATIONS MUST BE APPROVED IN WRITING BY McDONALD'S CORPORATION. <br />5. ALL BRANCH CIRCUIT WIRING TO 120 VOLT LIGHTING FIXTURES AND RECEPTACLES <br />SHALL BE AS FOLLOWS. <br />MAXIMUM LENGTH 85FT. - 2 #12, 1 #12 E_G. <br />MAXIMUM LENGTH 140FT. - 2 #10, 1 #10 E.G. <br />MAXIMUM LENGTH 225FT. - 2 #8, 1 #8 E.G. <br />MAXIMUM LENGTH 350FT. - 2 #6, 1 #6 E.G_ <br />6. ALL EXTERIOR J-BOXES AND RECEPTACLES SHOWN ON THIS PLAN SHALL BE <br />WATERPROOF. IF SIGNAGE DOES NOT COME WITH DISCONNECT SWITCH PROVIDE <br />TOGGLE SWITCH WITH WEATHERPROOF COVER. <br />ORDER ALL LIGHT FIXTURES FROM: <br />SECURITY LIGHTING SYSTEMS, INC. <br />PHONE: 1-800-LIGHT-IT <br />EMAIL: QUOTATIONS@SECURITYLIGHTING.COM <br />w i.-%rr_ <br />VERIFY LIGHTING FIXTURE CATALOGUE NUMBERS <br />WITH INTERIOR DESIGNER PRIOR TO ORDERING <br />FIXTURES. <br />14 <br />WP <br />J-BOX FOR J <br />McDONALDS } <br />FASADE SIGN J <br />O KEYNOTE LEGEND <br />1. CONNECT TO EXISTING CUSTOMER SERVICE LIGHTING CIRCUIT SERVING THIS AREA <br />2. CONNECT TO EXISTING DINING AREA LIGHTING CIRCUIT SERVING THIS AREA. <br />3. CONNECT TO THE EXISTING EXIT/EMERGENCY/NIGHT LIGHTING CIRCUIT. <br />4. EXISTING LIGHTING AND EMERGENCY LIGHTING IN THIS ARE TO REMAIN AS IS- <br />5- CONNECT TO EXISTING TOILET LIGHTING CIRCUIT THAT WAS MADE SPARE BY <br />DEMOLITION. <br />6. PROVIDE CEILING MOUNTED ULTRASONIC OCCUPANCY SENSOR IN RESTROOMS <br />(HUBBELL ATU500C). AIM SENSOR IN DIRECTION INDICATED BY ARROW FOR MAXIMUM <br />COVERAGE OF ROOM. REFER TO OCCUPANCY SENSOR DETAIL ON THIS SHEET. <br />ORDER ALL OCCUPANCY SENSORS FROM, SECURITY LIGHTING LIGHTING SYSTEMS, <br />INC. <br />7. EACH RESTROOM HAS ONE SENSORS THAT CONTROL ALL LIGHTS TOGETHER AT ONCE <br />IN RESPECTIVE RESTROOM. <br />8. CONNECT TO UNSWITCHED LEG OF THE RESTROOM LIGHTING CIRCUIT TO FEED <br />INVERTER. <br />9. CONNECT TO EXISTING KITCHEN/SUPPORT AREA LIGHTING CIRCUIT SERVING THIS <br />AREA. <br />10. CONNECT TO EXISTING PHOTOCELL EXTERIOR SECURITY LIGHTING CIRCUIT. <br />11. EC SHALL INSTALL AND CONFIGURE REMOTE EMERGENCY LIGHTING AT ALL EGRESS <br />EXTERIOR DOORS FOR MAXIMUM ILLUMINATION AT POINTS OF EGRESS_ INSTALL WP <br />J-BOX WITH IN SOFFIT TO ALLOW A FLUSH INSTALLATION OF ANY EXTERIOR <br />EMERGENCY EGRESS LIGHTING (TYPICAL). <br />12. CONNECT TO EXISTING EXTERIOR LIGHTING WALL SCONCE CIRCUIT. <br />13. REFER TO ARCHITECTURAL ELEVATIONS FOR HEIGHTS AND LOCATIONS OF WALL <br />SCONCE AND CANOPY DOWNLIGHTS. <br />14. EXISTING FRONT FASADE SIGN CIRCUIT. <br />LOAD SUMMARY <br />NO ADDITIONAL LOAD ADDED. <br />LOADS ADDED ARE OFFSET BY <br />LOADS REMOVED BY DEMOLITION <br />LK <br />• '• <br />.�� <br />Lr <br />z co <br />i zvv <br />o� <br />r 5 <br />j1 V♦ �p ocv�CL <br />© oo OGCOC <br />1p <br />v♦ o�$C E <br />0O� <br />THIS ITEM HAS BEEN ELECTRONICALLY <br />SIGNED AND SEALED BY ADAM T. <br />-� RALD <br />� = <br />POWELL, PE USING A DIGITAL <br />SIGNATURE AND DATE. PRINKED COPIES <br />ENGINEERING I N Q <br />OF THIS DOCUMENT ARE NOT <br />CONSIDERED SIGNED AND SEALED AND <br />D E 9942 CURRIAVIS DR. STE H., TAMPA, FL 33619 <br />THE SIGNATURE MUST BE VERIFIED ON <br />TEL <br />ANY ELECTRONIC COPIES- <br />WWW.FMFRAI.DMEP.COM EEI PR0IECT# 22072M <br />W04 <br />8 N <br />ap <br />b <br />.72 <br />0 <br />OL <br />Z <br />w <br />0 <br />O <br />2 <br />:LLJ <br />W <br />z <br /><< t <br />Z <br />O <br />1802.31 <br />E 1 0 <br />• <br />AA-0003276 <br />