My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6042 N Gall Bllvd
Zephyrhills
>
Building Department
>
Building Plans
>
6042 N Gall Bllvd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2025 4:30:09 PM
Creation date
2/18/2025 4:03:14 PM
Metadata
Fields
Template:
Building Plans
Street #
6042
Location
N Gall Blvd
Contractor
Purdy-Muroff Architecture, Inc
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PANEL AP4 <br />EXISTING <br />ELECTRICAL <br />MDP, AP1, AP2 <br />AND AP3 <br />GENERAL NOTES: <br />WIRE/RACEWAY: <br />JEW <br />EXISTING <br />PANEL LP <br />1. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2017 NATIONAL ELECTRICAL CODE <br />1. ALL CONDUCTORS SHALL BE COPPER, CONDUCTOR INSULATION SHALL BE DUAL TYPE <br />AND SHALL ALSO COMPLY WITH ALL APPLICABLE RULES AND REGULATIONS OF LOCAL <br />THHN/THWN 75-C. (167-F) FOR DRY, DAMP, AND WET LOCATIONS. CONDUCTOR <br />AND STATE LAWS AND ORDINANCES. <br />INSULATION WITH SINGLE TYPE MARKING THHN 90-C (194-F) MAY BE USED FOR DRY <br />LOCATIONS ONLY. ALL CONDUCTORS SHALL BE COLOR CODED AS REQUIRED BY NEC <br />2. CONTRACTOR SHALL MAKE A THOROUGH EXAMINATION OF THE SITE AND THE <br />AND FURTHER IDENTIFIED AND CODED AS SPECIFIED HEREINAFTER. COLOR CODING <br />CONTRACT DOCUMENTS. NO CLAIM FOR EXTRA COMPENSATION WILL BE <br />SHALL BE BY MEANS OF COLORED INSULATING MATERIAL, COLORED BRAID OR <br />RECOGNIZED IF DIFFICULTIES ARE ENCOUNTERED WHICH AN EXAMINATION OF SITE <br />JACKET OVER THE INSULATION OR BY MEANS OF SUITABLE COLORED, PERMANENT, <br />CONDITIONS AND CONTRACT DOCUMENTS PRIOR TO EXECUTING CONTRACT WOULD <br />NON -AGING, INSULATING TAPE APPLIED TO CONDUCTORS AT EACH CABINET OR <br />HAVE REVEALED. <br />JUNCTION POINT. THE COLOR CODING SHALL BE ACCOMPLISHED AS THE <br />CONDUCTORS ARE INSTALLED. THE FOLLOWING SYSTEMS OF COLOR CODING SHALL <br />3. ELECTRICAL CONTRACTOR SHALL ARRANGE FOR ALL NECESSARY PERMITS, <br />BE STRICTLY ADHERED TO: <br />LICENSES, UTILITY COORDINATION AND INSPECTIONS AS REQUIRED BY THE CITY OR <br />UTILITY COMPANY. OWNER WILL PAY FEES. CONTRACTOR IS RESPONSIBLE FOR ALL <br />A) GROUND LEADS: GREEN <br />EQUIPMENT REQUIRED BY UTILITY COMPANY AND SHOULD INCLUDE NECESSARY <br />COSTS IN BID. <br />B) 120/208 VOLT UNGROUNDED PHASE WIRES. - <br />PHASE A: BLACK <br />4. CONTRACTOR SHALL LEGIBLY MARK-UP A SET OF 24"x36" DRAWINGS TO REFLECT <br />PHASE B: RED <br />AS -BUILT CONDITIONS AND TURN OVER TO THE ARCHITECT. <br />PHASE C: BLUE <br />NEUTRAL: WHITE <br />5. PANELBOARD MANUFACTURER SHALL PROVIDE ARC -FLASH WARNING LABELES FOR <br />MDP AND ALL BRANCH PANELBOARDS IN ACCORDANCE WITH NEC 110. <br />THE COLOR CODE ASSIGNED TO EACH PHASE WIRE SHALL BE CONSISTENTLY <br />FOLLOWED THROUGHOUT <br />GROUNDING: <br />2. ALL BRANCH CIRCUIT WIRING TO 120 VOLT LIGHTING FIXTURES AND RECEPTACLES <br />SHALL BE AS FOLLOWS. <br />1. THE INTERIOR ELECTRICAL SYSTEMS SHALL BE COMPLETELY AND EFFECTIVELY <br />MAXIMUM LENGTH 85FT. - 2 #12, 1 #12 E.G. <br />GROUNDED AS REQUIRED BY NATIONAL ELECTRICAL CODE ALL METALLIC RACEWAYS <br />MAXIMUM LENGTH 140FT. - 2 #10, 1 #10 E.G. <br />SHALL BE MECHANICALLY AND ELECTRICALLY SECURE AT ALL JOINTS AND AT ALL <br />MAXIMUM LENGTH 225FT. - 2 #8, 1 #8 E.G. <br />BOXES, CABINETS, FITTINGS AND EQUIPMENT. <br />MAXIMUM LENGTH 350FT. - 2 #6, 1 #6 E.G. <br />OUTLET BOXES/DEVICES: <br />3. UNLESS OTHERWISE NOTED ALL CONDUCTORS SHALL BE RUN IN THIN WALL CONDUIT <br />AND THIN WALL CONDUIT SHALL BE UNDERWRITERS' APPROVED GALVANIZED <br />ELECTRICAL METALLIC TUBING. COUPLINGS AND CONNECTORS SHALL BE STEEL <br />1. ALL OUTLET BOXES SHALL BE RIGIDLY MOUNTED AND SHALL BE EQUIPPED WITH SET -SCREW TYPE, ZINC OR CADMIUM PLATED. MC CABLE MAY BE USED WHERE <br />SUITABLE SCREW FASTENED COVERS. OPEN KNOCKOUTS OR HOLES IN BOXES CONCEALED IN WALLS. <br />SHALL BE PLUGGED WITH SUITABLE BLANKING DEVICE. <br />4. ALL RACEWAYS SHALL BE PROPERLY ALIGNED, GROUPED, AND SUPPORTED BY <br />2. OUTLET BOXES SHALL BE 4 INCH SQUARE x 2-1/8" DEEP. OUTLET BOXES LOCATED MECHANICAL TYPE 'CADDY' CLIPS AT INTERVALS NOT EXCEEDING 8 FEET. <br />ABOVE THE CEILING SHALL BE LEGIBLY IDENTIFIED WITH BRANCH CIRCUIT NUMBER <br />OF CIRCUIT TERMINATED WITHIN BY MEANS OF BLACK PERMANENT MARKER. 5. ALL RACEWAYS WITH NO. 10 OR 12 AWG PHASE CONDUCTORS FOR RECEPTACLES, <br />LIGHTING FIXTURES AND SIMILAR CIRCUITS SHALL BE PROVIDE WITH A PARITY SIZED <br />GREEN EQUIPMENT GROUND CONDUCTOR. GROUND CONDUCTOR SHALL BE <br />SWITCHGEAR: INSTALLED IN ENTIRE RACEWAY SYSTEM INCLUDING WALL SWITCHES AND FLEXIBLE <br />CONDUIT TO LIGHT FIXTURES. EQUIPMENT GROUND CONDUCTOR SIZES FOR <br />1. PANELBOARD DIRECTORY CARDS SHALL BE TYPEWRITTEN WITH ACCURATE AND CIRCUITS WITH PHASE CONDUCTORS LARGER THAN NO. 12 AWG ARE INDICATED ON <br />CURRENT INFORMATION BY THE CONTRACTOR AT THE END OF CONSTRUCTION. DRAWINGS. GROUND CONDUCTORS SHALL BE CONNECTED TO GROUND BUSS IN <br />PANELBOARDS. <br />6. RACEWAY PENETRATIONS OF FIRE RATED WALLS AND/OR FLOORS SHALL BE SEALED <br />TO MAINTAIN INTEGRITY OF CONSTRUCTION. ALL PRODUCTS, MATERIALS AND <br />METHODS OF INSTALLATION SHALL BE UL APPROVED AND MEET NFPA. <br />7. ALL ELECTRICAL CONDUITS SHALL BE CONCEALED IN WALLS UNLESS AS -BUILT <br />CONDITIONS PROHIBITS. GC TO NOTIFY ARCH/ACM OF AS -BUILT CONDITIONS. <br />POWER PLAN <br />SCALE: 1/4" = 1'-0" <br />O KEYNOTE LEGEND <br />1. RACEWAY KIT PROVIDED WITH COUNTER, INSTALLED BY EC. <br />2- IF OPTIONAL TABLE TRACKER SYSTEM IS TO BE USED. IF USED, PROVIDE 2 #12 AND 1 <br />#12 GROUND TO AVAILABLE SPARE 20A/l P BREAKER. CONNECT CIRCUIT TO (3) 5-20R <br />RECEPTACLES, (1) RECEPTACLE FOR MODEM/GATEWAY (TYPICALLY LOCATED BEHIND <br />VALENCE AT T-9" AFF), (1) RECEPTACLE FOR LOCATOR CHARGER (TYPICALLY <br />LOCATED IN MANAGERS OFFICE) AND (1) RECEPTACLE FOR MONITOR (TYPICALLY <br />LOCATED AT PICKUP COUNTER). COORDINATE EXACT LOCATION(S) IN THE FIELD. <br />3. COORDINATE LOCATION AND REQUIREMENTS OF HAPPY MEAL DISPLAY WITH DECOR <br />COMPANY. TIE INTO LIGHTING CIRCUIT SERVING THIS AREA, 2 #12 AND 1 #12 E.G. IN <br />1/2" CONDUIT. <br />4_ RELOCATED ORDERING KIOSK. COORDINATE EXACT LOCATION AND REQUIREMENTS <br />WITH ARCHITECT AND OWNER PRIOR TO RELOCATIONS. EXTEND CIRCUITRY AND <br />CONDUCTOR AS REQUIRED. VERIFY THAT EACH KIOSK IS POWERED BY A 1 POLE 20 <br />AMP CIRCUIT BREAKER. <br />5, COORDINATE LOCATION AND REQUIREMENTS OF FUTURE CASH HANDLER WITH <br />DECOR COMPANY. POWER IS FED FROM ORDERING KIOSK BASE PLATE, IF NOT <br />LOCATED NEXT TO THE WALL. IF LOCATED NEXT TO TO A WALL THEN FEED FROM <br />WALL POWER. <br />6. COORDINATE LOCATION AND REQUIREMENTS OF J-BOX FOR DECOR ELEMENT WITH <br />DECOR DRAWINGS. 2 #12 AND 1 #12 E.G. IN 1/2" CONDUIT. <br />7. CONNECT TO SPARE 20 AMP - 1 P, 120 VOLT BREAKER. FURNISH AND INSTALL <br />BREAKER IF A SPARE IS NOT AVAILABLE. <br />CONTRACTOR TO FIELD VERIFY CIRCUIT NUMBERS <br />AND EXACT NUMBER OF SPARES AVAILABLE. <br />I <br />I <br />I I <br />I I <br />I I <br />1 <br />I <br />� I <br />I I <br />� I <br />E7, <br />SEE SHEET E3.0 <br />FOR REQUIREMENTS <br />z <br />O <br />F <br />d <br />U <br />N <br />w <br />0 <br />z <br />0 <br />0 <br />0 <br />W <br />O <br />W <br />(n <br />W <br />N <br />M a <br />o � <br />U' <br />• <br />E <br />o <br />O <br />c • <br />• <br />r E <br />p E <br />L <br />^ <br />O <br />• <br />• <br />al <br />ca a <br />- <br />O � <br />� <br />U <br />w <br />S <br />THIS ITEM HAS BEEN ELECTRONICALLY <br />SIGNED AND SEALED BY ADAM T. <br />_� � ���� <br />� <br />POWELL, PE USING A DIGITAL <br />SIGNATURE AND DATE. PRINTED COPIES <br />ENGINEERING I N Q <br />OF THIS DOCUMENT ARE NOT <br />CONSIDERED SIGNED AND SEALED AND <br />9942 CURRIE DAVIS DR. STE H., TAMPA, FL 33619 <br />THE SIGNATURE MUST BE VERIFIED ON <br />TEL (813) 995-0300 <br />ANY ELECTRONIC COPIES. <br />WWW.EMERALDMEP.COM EEI PROJECT# 22072M <br />N <br />W � � <br />g0 a <br />Q <br />Q <br />0 <br />Of <br />I � <br />� <br />Ld <br />*z <br />0 <br />0 <br />Ld <br />z <br />Milo n <br />0 <br />z <br />1802.31 <br />E2oO <br />AA-0003276 <br />