<br />LOAD SUMMARY
<br />EXISTING MDP (1000 AMP MAIN BREAKER)
<br />EXISTING LOAD @ 125%
<br />PER NEC 220.87 180,500 VA
<br />NEW ADDITIONAL LOAD 16,512 VA
<br />NEW TOTAL 197,012 VA
<br />(547 AMPS) Z
<br />O
<br />EXISTING Z
<br />O
<br />O
<br />W
<br />0
<br />W 12
<br />N
<br />0
<br />y w
<br />�4ti1 rlr�/��,
<br />._
<br />fi Q u�-
<br />`.
<br />_ 1
<br />��R rir
<br />• • t?
<br />U• .
<br />•
<br />O
<br />• m
<br />a�
<br />L
<br />..
<br />I. ao
<br />+ U'
<br />• C M
<br />>1
<br />.Q
<br />• =
<br />EXISTING 'Z3
<br />w
<br />U• $
<br />°W
<br />�• •zM
<br />a <c
<br />(Z
<br />��� "
<br />J
<br />J� ;
<br />a all -1
<br />co B
<br />o
<br />O
<br />5
<br />N
<br />NOTE:
<br />1. USE EXISTING CIRCUITRY, CONTRACTOR TO VERIFY EXISTING CIRCUITS AND
<br />BREAKER SIZE. UPGRADE BREAKER AND CIRCUIT TO MATCH NEW EQUIPMENT CONTRACTOR TO FIELD VERIFY CIRCUIT NUMBERS
<br />REQUIREMENTS IF EXISTING CIRCUIT IS TOO SMALL. VERIFY EXISTING CIRCUIT
<br />NUMBERS AND RECORD ON AS -BUILT DRAWINGS FOR INSPECTORS REVIEW AND EXACT NUMBER OF SPARES AVAILABLE. g
<br />DURING ROUGH -IN INSPECTION.
<br />O
<br />ALL SINGLE-PHASE RECEPETACLES RATED 150 VOLTS Ld M
<br />TO GROUND OR LESS, 50 AMPERES OR LESS AND SEE SHEET E2.0
<br />THREE-PHASE RECEPTACLES RATED 150 VOLTS TO FOR REQUIREMENTS 0 o
<br />GROUND OR LESS, 100 AMPERES OR LESS INSTALLED '
<br />THIS ITEM HAS BEEN ELECTRONICALLY ����
<br />SHALL HAVE GROUND -FAULT CIRCUIT -INTERRUPTER S1POWELL"PEU3IJGADIGTALT _M= 1e02.31
<br />PROTECTION FOR PERSONNEL. ELECTRICAL ROUGH -IN INFORMATION SIGNATURE AND DATE. PRINTED COPIES ENGINEERING LNG,
<br />OF THIS DOCUMENT ARE NOT 9942 CURRIE DAVIS DR. STE H., TAMPA, FL 33619
<br />CONSIDERED SIGNED AND SEALED AND TEL (813) 995-0300 !�! •
<br />THE SIGNATURE MUST BE VERIFIED ON �j
<br />0
<br />ANY ELECTRONIC COPIES. WWW.EMERALDMEP.COM EEI PROJECT* 22072M M-WO3276
<br />PANEL "AP1"
<br />SIEMENS
<br />208Y/120V, 3QJ, 4W
<br />VOLTAGE/PHASE
<br />225A MLO
<br />225A BUS
<br />NEMA-1
<br />MODULAR
<br />SERIES RATED
<br />COPPER Bus
<br />SOLID NEUTRAL
<br />CKT
<br />AMPS
<br />POLE
<br />1
<br />DESCRIPTION
<br />NOTES
<br />LQVAAD
<br />CKT
<br />AMPS
<br />POLE
<br />DESCRIPTION
<br />I,p�g
<br />LOAD
<br />1
<br />3
<br />20
<br />Ex SALAD CASE
<br />1224
<br />2
<br />20
<br />1
<br />1
<br />EX a/HOT cHocoLATE
<br />1440
<br />0
<br />20
<br />1
<br />EX BEVERAGE BAR RECEPT
<br />360
<br />2246
<br />4
<br />20
<br />SPARE
<br />5
<br />30
<br />2
<br />EX ABS MACHINE
<br />6
<br />30
<br />2
<br />EX BLUE REAR OEP
<br />2246
<br />7
<br />2246
<br />8
<br />2246
<br />9
<br />20
<br />1
<br />IX ICE DISP BEVERAGE BAR
<br />132
<br />10
<br />20
<br />2
<br />EX BLUE REAR OEP
<br />1602
<br />11
<br />20
<br />1
<br />IX ICE DISP BEVERAGE BAR
<br />132
<br />12
<br />1602
<br />13
<br />20
<br />1
<br />DINING DECOR ELEMENT
<br />1
<br />600
<br />14
<br />20
<br />1
<br />EX FRY DISP
<br />720
<br />15
<br />30
<br />2
<br />FJ( BLUE REAR OEP
<br />2246
<br />16
<br />20
<br />1
<br />EX YELLOW REAR OEP
<br />480
<br />17
<br />2246
<br />18
<br />20
<br />1
<br />IX FRY BAGGING STATION
<br />1884
<br />19
<br />1602
<br />20
<br />20
<br />1
<br />IX
<br />PANEL "AP4"
<br />SQUARE D: NQ
<br />208Y/120V, 3QJ, 4W
<br />VOLTAGEJPHASE
<br />200A MLO
<br />200A BUS
<br />NEMA-1
<br />SURFACE
<br />CKT AMPS POLE
<br />2 20 1
<br />SERIES RATED
<br />COPPER Bus
<br />SOLID NEUTRAL
<br />NOTES L�
<br />600
<br />CKT
<br />AMPS
<br />POLE
<br />DESCRIPTION
<br />EX REFPoG COUNTER
<br />NOTES
<br />LVQ4AD
<br />DESCRIPTION
<br />EX ABS
<br />EX SMDTHEE
<br />1
<br />20
<br />1
<br />720
<br />3
<br />20
<br />1
<br />Ex. SILVER KING
<br />960
<br />4
<br />6
<br />20
<br />ZO
<br />1
<br />1
<br />1200
<br />1200
<br />5
<br />20
<br />1
<br />EX ABS IN CHASE
<br />600
<br />EX OJ MACHINE
<br />7
<br />30
<br />2
<br />EX SPECIALTY COFFEE
<br />Ex SAFE
<br />2246
<br />8
<br />20
<br />1
<br />EX INDOOR DIRECT
<br />900
<br />9
<br />2246
<br />10
<br />20
<br />1
<br />EX RTl OUTLETS
<br />EX TOASTER
<br />EX TIME CLOCK
<br />900
<br />1813
<br />11
<br />13
<br />20
<br />30
<br />1
<br />2
<br />120
<br />2246
<br />12
<br />30
<br />3
<br />IX TEA BREWER
<br />14
<br />1813
<br />1813
<br />120
<br />15
<br />2246
<br />16
<br />17
<br />30
<br />2
<br />EX LOAD
<br />EX PRINTER
<br />2246
<br />2246
<br />18
<br />20
<br />20
<br />30
<br />1
<br />2
<br />19
<br />FJCQINGOVEN
<br />1602
<br />21
<br />20
<br />1
<br />1000
<br />22
<br />1602
<br />23
<br />20
<br />1
<br />EX DTT 2
<br />300
<br />24
<br />�
<br />2
<br />EX VIPER
<br />Ex LOAD
<br />Q'ING OVEN
<br />1487
<br />25
<br />20
<br />1
<br />Ex,DtT_1_ -
<br />BAKED G000sroco
<br />1
<br />300
<br />26
<br />1487
<br />1487
<br />27
<br />29
<br />20
<br />20
<br />1
<br />1
<br />360
<br />1356
<br />28
<br />30
<br />�
<br />2
<br />REACH -IN REFRIG
<br />-
<br />1,2
<br />1487
<br />1602
<br />31
<br />33
<br />20 -_-
<br />20
<br />1 _
<br />1
<br />BASE REFRIGERATOR
<br />1 2
<br />768
<br />960
<br />32 -
<br />34
<br />20
<br />2
<br />t,2
<br />FINISHING STATION
<br />CASH RECYCLER
<br />1,2
<br />1
<br />1602
<br />1602
<br />35
<br />20
<br />1
<br />528
<br />36
<br />20
<br />Z
<br />Q'INGOVEN
<br />1,2
<br />37
<br />20
<br />1
<br />DELIVERY TABLETS
<br />1
<br />720
<br />38 20 1 KVS/PO61ST1CKY LABEL t
<br />41 20 1 HOT WATER DISPENSER 1,2 _
<br />NOTES: IDESCRIP
<br />1 • NEW BREAKER TO MATCH TYPE AND AIC RATING OF EXISTING
<br />BREAKERS IN THIS PANEL.
<br />134 40 20 1 DINING__RECEPTACLES 1 720
<br />1 DINING RECEPTACLES 1 900
<br />LOAD EC D MA D
<br />184 "CND(VA -_- FA
<br />LIGHTING 0 0.00 0
<br />HVAC -COOL 0 0.00 0
<br />HVAC -HEAT 0 0.00 0
<br />RECEPTACLE 10, 372 0.98 10,186
<br />MISC _ 42,527 1.00 42,527
<br />TOTAL 52, 899 52, 713
<br />2.
<br />GFI BREAKER PER NEC 210.8
<br />3.
<br />q_
<br />5.
<br />8.
<br />TOTAL DEMAND CURRENT 208Y/120V 30 146.3-AMPS
<br />ELECTRICAL SYMBOL LEGEND
<br />SYMBOL
<br />DESCRIPTION
<br />JUNCTION BOX WITH TWO (2) DUPLEX (20A; 125V.) RECEPTACLES
<br />JUNCTION BOX WITH DUPLEX (20A; 125V.) RECEPTACLE
<br />Q
<br />JUNCTION BOX
<br />®
<br />JUNCTION BOX WITH SPECIAL PURPOSE
<br />®
<br />JUNCTION BOX WITH ISOLATED GROUND RECEPTACLE
<br />TP
<br />TAMPER RESISTANT GFCI DUPLEX RECEPTACLE/USB COMBO MOUNTED AT
<br />18" AFF. IN PUBLIC AREAS. EC SHALL PROVIDE PASS AND SEYMOUR
<br />"SAFELOCK" 2095-TR--'` (""" I -IVORY, W=WHITE, GRY=GRAY, BK=BLACK,
<br />RED=RED, LA=LIGHT ALMOND). SPECIFIED RECEPTACLE BECOMES DE -
<br />ENERGIZED UPON FAILURE OF GFI DEVICE. NO SUBSTITUTIONS. (TYPICAL)
<br />RACEWAY CONCEALED IN WALL OR CEILINGS
<br />HOMERUN TO PANEL
<br />PB = Pullbox VIF =Verify in Field ELECTRICAL
<br />SCHEDULE
<br />JB =Junction Box
<br />EC =Electrical Contractor
<br />TAG # QTY DESCRIPTION VOLT/PH FLA BRK SIZE COND/WIRE PNUCCT RECEP TYPE HGT AFF REQUIREMENTS &REMARKS
<br />004.20E6 1 MENU BOARD -DIGITAL 120/1 2.6 20A 2 #12, 1 #12 IG AND NOTE 1 IG5262 6'-5"
<br />ISOLATED 1 #12 EG - 1/2"C
<br />004.20E7 1 FREESTANDING DIGITAL MERCHANDISER 120/1 2.6 20A 2 #12, 1 #12 IG AND NOTE 1 IG5262 CLG -
<br />ISOLATED 1 #12 EG - 1/2"C
<br />004.23E2 1 DIGITAL MERCHANDISER -MEDIA PLAYER DATA CABLE - - JB 6'-5" JB W/ 1" C. TO FULL HEIGHT WALL AND TO ABOVE CEILING W/ BUSHING FOR
<br />DATA CABLES. SUPPLY W/ GROMMETED OPENING IN COVER PLATE
<br />012.03E2 1 BAKED GOODS DISPLAY CASE 12011 1.5 20A 2 #12, 1 #12EG - 1/2"C AP4-27 5-15R SEE RMKS PROVIDE RECEP. IN COUNTER -MOUNTED RACEWAY
<br />009.14E1 1 UTILITY CHASE DR BEVERAGE VERSION - - - - SEE RMKS CHASE AND RECEPTACLES BY KES
<br />009.15E1 1 UTILITY CHASE DR BOOTH - - - - SEE RMKS CHASE AND RECEPTACLES BY KES
<br />020.00E2 1 AUTOMATED BEVERAGE SYSTEM 12011 5.0 20A 2 #12, 1 #12EG - 1/2"C NOTE 1 5-20R 2'
<br />-VA 0
<br />" EC TO BRING POWER DOWN WALL, PROVIDE/INSTALL RECEPTACLE
<br />020.00E3 1 AUTOMATED BEVERAGE SYSTEM DATA CABLE - - - - - SEE RMKS CABLE FURNISHED/INSTALLED BY POS INSTALLER
<br />020.99E2 1 ABS PRECOOLER 120/1 14.9 20A 2 #12, 1 #12EG - 1/2"C NOTE 1 5-20R 3'-10" EC TO BRING POWER DOWN WALL, PROVIDE/INSTALL RECEPTACLE
<br />039.15E3 1 ICE MACHINE - 1000 LB 120/1 1.1 15A 2 #12, 1 #12EG - 1/2"C NOTE 1 5-15R � CLG CIRCUIT BREAKER SHALL BE HACR TYPE
<br />041.09E1 1 ICE MACHINE REMOTE CONDENSER - 1000 LB 208/3 10.8 15A 3 #12, 1 #12EG -1/2•C NOTE 1 SEE RMKS SEE RMKS EC TO PROVIDE WP 30A-3P NF DISC AT UNIT ON ROOF. CIRCUIT BRAKERS
<br />SHALL NE HACR TYPE. CONTROL WIRE TO ICE MACHINE LOCATION BY ACM
<br />044.29E1 1 BREAKER PANEL 125 AMP - 3 PHASE 120-208/3 SEE RMKS 125A 4 #1, 1 #6 E.G. - 1 1/2"C NOTE 1 - SEE RMKS EC TO EXTEND EXISTING SERVICE AS REQ 8 CONNECT TO PANEL
<br />EQUIPMENT MOUNTED
<br />044.98E1 1 48" HLS TABLE 120/1 11.0 20A 2 #12, 1 #12EG - 1!2"C 044.29E1 - SEE RMKS EC TO EXTEND CIRCUIT TO KES OUTLET TO CHASE
<br />129.00E2 2 Q'ING OVEN 208/1 20 20A 2 #12, 1 #12EG - 1/2"C AP4-(32,34)(36,38) 6-20R 5'-6" PLUGS INTO OVERHEAD RECEPTACLE #32006W(B) PROVIDE BY KES
<br />HEIGHT TO BOTTOM OF RECEPTACLE
<br />178.13E2 1 REACH -IN REFRIGERATOR -SINGLE WIDE 120/1 11.3 20A 2 #12, 1 #12EG - 1!2"C AP4-29 5-20R SEE RMKS EC TO BRING POWER DOWN CHASE AND CONNECT TO CHASE MOUNTED
<br />RECEPTACLE
<br />207.09E1 1 30" BASE REFRIGERATOR 120/1 3.2 20A 2 #12, 1 #12EG - 1/2"C AP4-31 5-20R 2'-0" EC TO BRING POWER DOWN WALL, PROVIDE/INSTALL RECEPTALE
<br />207.10E1 1 FINISHING STATION 120/1 8.0 20A 2 #12, 1 #12EG - 1/2"C AP4-33 5-20R 2'-0" EC TO BRING POWER DOWN WALL, PROVIDE/INSTALL RECEPTALE
<br />207.11E4 1 BASE REFRIGERATOR 120/1 3.2 20A 2 #12, 1 #12EG - 1/2"C AP4-31 5-20R 2'-0" EC TO BRING POWER DOWN WALL, PROVIDE/1NSTALL RECEPTALE
<br />210.00E10 1 FUTURE CASH RECYCLER 120/1 4.4 20A 2 #12, 1 #12 IG AND AP4-35 (2) IG4700 SEE RMKS PROVIDE RECEPTACLE IN COUNTER -MOUNTED RACEWAY
<br />ISOLATED 1 #12 EG - 1/2"C
<br />211.00E6 2 DELIVERY TABLETS 120/1 3.0 20A 2 #12, 1 #12EG - 1!2"C AP4-37 (2) 5-20P 5'-6" -
<br />213.00E10 1 TABLET BRACKET 120/1 2.6 20A 2 #12, 1 #12 IG AND NOTE 1 SEE RMKS SEE RMKS PROVIDE IG RECEPTACLE IN COUNTER -MOUNTED RACEWAY
<br />ISOLATED 1 #12 EG - 1/2"C
<br />213.00E11 1 TABLET BRACKET 120/1 1.5 20A 2 #12, 1 #12 IG AND SEE RMKS 5-20R SEE RMKS EXTEND NEARBY APPLIANCE PANEL CIRCUIT TO NEW RECEPTACLE
<br />ISOLATED 1 #12 EG - 1/2"C
<br />215.00E3 1 POS REGISTER -FRONT COUNTER DATA CABLE - - - - PB 10" EXTEND 2" CONDUIT TO ABOVE CEILING FOR POS DATA CABLES
<br />215.00E12 1 POS REGISTER -FRONT COUNTER 120/1 3.0 20A 2 #12, 1 #12 IG AND NOTE 1 IG4700 SEE RMKS PROVIDE IG RECEPTACLE IN COUNTER -MOUNTED RACEWAY
<br />ISOLATED 1 #12 EG - 1/2"C
<br />215.00E15 1 POS REGISTER -FRONT COUNTER DATA CABLE - - - PB 10" EXTEND TWO 1" CONDUITS TO ABOVE CEILING FOR POS DATA CABLES
<br />215.05E2 1 NEW KVS MONITOR DATA CABLE - - - - - SEE RMKS CABLE FURNISHED AND INSTALLED BY POS SUPPLIER
<br />215.05E3 1 NEW KVS MONITOR 120/1 1.5 20A 2 #12, 1 #12 IG AND AP4-39 IG4700 SEE RMKS DOWN CHASE, POS INSTALLER TO MAKE FINAL CONNECTIONS
<br />ISOLATED 1 #12 EG - 1/2"C
<br />215.07E1 1 POS REGISTER -DELIVERY 120/1 3.0 20A 2 #12, 1 #12 IG AND AP4-39 IG4700 42"
<br />ISOLATED 1 #12 EG - 1/2"C
<br />215.07E3 1 POS - KVS MONITOR - - - - PB 42" EXTEND 2" CONDUIT TO ABOVE CEILING FOR POS DATA CABLES
<br />216.00E2 2 POS -VIDEO MONITOR DATA CABLE - - - - - - CABLE FURNISHED/INSTALLED BY POS INSTALLER
<br />216.00E3 1 POS -VIDEO MONITOR W/ SUPPORTS 120/1 1.5 20A 2 #12, 1 #12 IG AND AP4-39 IG4700 � CLG EC TO PROVIDE/INSTALL RECEPTACLE, POS INSTALLER TO CONNECT POS
<br />ISOLATED 1 #12 EG - 1/2"C
<br />216.00E7 1 POS -VIDEO MONITOR W/ SUPPORTS (a� CHASE 120/1 1.5 20A 2 #12, 1 #12 IG AND AP4-39 IG4700 SEE RMKS EC TO BRING POWER DOWN CHASE AND CONNECT TO CHASE MOUNTED
<br />ISOLATED 1 #12 EG - 1/2"C RECEPTACLE
<br />216.00E11 1 POS -VIDEO MONITOR 120/1 1.5 20A 2 #12, 1 #12 IG AND AP4-39 IG4700 5'-0" CABLE PROVIDED AND INSTALLED BY POS SUPPLIER
<br />ISOLATED 1 #12 EG - 1/2"C
<br />216.00E12 1 POS -VIDEO MONITOR DATA CABLE - - - 4x4x4 PB 5'-8" EXTEND 2" CONDUIT ABOVE CEILING. CABLE FURNISHED AND INSTALLED
<br />BY POS SYSTEM SUPPLIER
<br />216.04E1 1 ORB MONITOR (MINI) 8 SCANNER 120/1 1.5 20A 2 #12, 1 #12 IG AND AP4-39 (2) IG4700 1'-6" -
<br />ISOLATED 1 #12 EG - 1/2"C
<br />218.05E4 1 ORB MONITOR 120/1 1.5 20A 2 #12, 1 #12 IG AND NOTE 1 IG4700-
<br />ISOLATED 1 #12 EG - 1/2"C
<br />216.05E5 1 ORB MONITOR 120/1 1.5 20A 2 #12, 1 #12 IG AND NOTE 1 IG4700 8'-1" JB W/ 1-1/2"C. TO TERMINATE ABOVE CEILING W/BUSHINGS FOR DATA CABLE
<br />ISOLATED 1 #12 EG - 1/2"C SUPPLY W/ GROMMETED OPENING IN COVER PLATE.
<br />217.00E1 3 PARK/ROTATE/SERVE BUMP BAR DATA CABLE - - - - - SEE RMKS POS TO COORD W/ MCD O/O, RELCOATED EXIST AS REQUIRED
<br />219.00E10 2 POS -RECEIPT PRINTER 120/1 0.7 20A 2 #12, 1 #12 IG AND NOTE 1 IG4700 SEE RMKS PROVIDE IG RECEPTACLE IN COUNTER -MOUNTED RACEWAY
<br />ISOLATED 1 #12 EG - 1/2"C
<br />219.02E2 3 CYT POS -RECEIPT PRINTER 120/1 0.7 20A 2 #12, 1 #12 IG AND NOTE 1 IG4700 TBD POS INSTALLER TO COORDINATE WITH MCD
<br />ISOLATED 1 #12 EG - 1/2"C
<br />219.05E3 1 STICKY LABEL PRINTER 120/1 0.7 20A 2 #12, 1 #12 IG AND AP4-39 IG4700 38" FOR DELIVERY STATION
<br />ISOLATED 1 #12 EG - 1/2"C
<br />700.09E1 1 ECONOMY OEP BOX W/ MOUNTING HARDWARE - - SEE RMKS CEILING MOUNTED
<br />701.13E16 1 DCO -GENERAL PURPOSE 120/1 1.5 20A 2 #12, 1 #12EG - 1/2"C AP4-27 5-20P SEE RMKS PROVIDE RECEPTACLE IN COUNTER -MOUNTED RACEWAY
<br />7000.12E2 1 HOT WATER DISPENSER 120/1 15.4 20A 2 #12, 1 #12EG - 1/2'C AP4-41 5-20R SEE RMKS PLUGS INTO CENTER ISLAND BREAKER PANEL OR OUTLET HOUSING
<br />8021.01E2 3 RELOCATED COFFEE BREWER - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8021.10E2 1 RELOCATED SPECIALTY COFFEE - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8021.11E2 1 RELOCATED SMOOTHIE MACHINE - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8021.98E2 1 RELOCATED SUGAR DISPENSER - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8023.05E2 2 RELOCATED CREAM DISPENSER - - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8024.01E1 1 RELOCATED ORANGE JUICE DISPENSER, DUAL FLAVO - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8025.02E2 1 RELOCATED ICED TEA BREWER - - - NOTE 1 GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8039.09E1 1 RELOCATED ICE MACHINE - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8118.00E1 1 RELOCATED Q'ING OVEN - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8118.00E3 1 RELOCATED Q'ING OVEN - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8118.00E5 1 RELOCATED Q'ING OVEN - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8122.27E1 1 RELOCATED HRT TOASTER - NOTE 1 GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8131.02E1 1 RELOCATED BISCUIT OVEN - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8178.08E1 2 RELOCATED REACH -IN REFRIGERATOR - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8181.01 E2 1 RELOCATED REFRIGERATOR -SPECIALTY COFFEE - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8203.02E2 1 RELOCATED COMBO SHAKE/SUNDAE MACHINE - - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8205.11E2 1 RELOCATED FROZEN CARBONATED BEVERAGE - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8207.09E1 1 RELOCATED BASE REFRIGERATOR - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8215.05E2 4 RELOCATED KVS MONITOR - - - NOTE 1 GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8215.05E3 4 RELOCATED KVS MONITOR - - NOTE 1 GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8215.98E1 1 RELOCATED POS PC HARDWARE - 2 BOOTH DR - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8215.98E2 2 RELOCATED POS PC HARDWARE - 2 BOOTH DR - - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8216.00E2 2 RELOCATED POS -VIDEO MONITOR - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8218.00E7 2 RELOCATED POS -VIDEO MONITOR � CHASE - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8217.00E1 2 RELOCATED PARK/ROTATE/SERVE BUMP BAR - - - - NOTE 1 - - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8217.13E2 1 RELOCATED MERGE POINT MONITOR - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8219.00E7 1 RELOCATED POS-RECEIPT PRINTER - - - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8219.00E8 1 RELOCATED POS-RECEIPT PRINTER - - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />8327.00E1 1 RELOCATED PIE DISPLAY - NOTE 1 - GC TO VERIFY AND REQORK ALL EXISTING UTILITES AS REQUIRED
<br />
|