Laserfiche WebLink
DRAWING SYMBOLS & LEGEND =ABBREVIATIONS LEGEND BUILDING CODES ® CLUBHOUSE <br />CENTERLINE OFBUILDING/OBJECT AC AIR CQNDITIONED(ER` imAT KILN DRIEn AFTER TPFATMFNIT APPLICABLE CODES: <br />e <br />IN <br />to <br />M <br />N <br />0 <br />0 <br />04 <br />00 <br />r_ <br />0 <br />a) <br />0 <br />.w <br />z <br />Q <br />U <br />a_ <br />0 NUMBERED DOOR SYMBOLS <br />Alk 0'-oei <br />ELEVATION TARGET INDICATES HT. A.F.F. <br />DESCRIPTION <br />01 KEY NOTE WITH LEADER INDICATOR <br />REVISION DELTA <br />1 DWGV.� SCALE TITLE MARKER <br />0 LETTERED WINDOW SYMBOL (BY TYPE) <br />COMPLETE SECTION: <br />DETAIL NUMBER <br />A5.01 LOCATION AND DIRECTION OF CUT <br />SHEET ON WHICH DETAIL APPEARS <br />(Dj <br />PARTIAL SECTION <br />D 1 INTERIOR ELEVATION: <br />A5.01 B DETAIL DIVISION <br />C <br />tN-1 ASSEMBLY TAG: <br />DESIGNATION <br />AFF <br />AHJ <br />AHU <br />ALT <br />ALUM <br />APT <br />BALL <br />BFF <br />BLDG <br />BLKG <br />BM <br />BR <br />BRG <br />BRZWY <br />BTM <br />CAB <br />CALC <br />CER <br />CFM <br />CFS <br />CIP <br />CJ <br />CL <br />CLG <br />CLOS <br />CLR <br />CMU <br />COL <br />CONC <br />COND <br />CONT <br />CORR <br />CID <br />CPT <br />CT <br />CW <br />D <br />DIA <br />DIM <br />DN <br />DIN <br />DP <br />DR <br />DS <br />DTL <br />DW <br />DWG <br />EA <br />ELEC <br />ELEV <br />ENG <br />EOS <br />EQ <br />EQUIV <br />EWC <br />EXP <br />EXT <br />EXTG <br />FRCP <br />FB <br />FBC <br />FD <br />FE <br />FF <br />FIN <br />FJS <br />FLR <br />FM <br />FOM <br />FP <br />FPM <br />FIR <br />FRCP <br />FRP <br />FT <br />FTG <br />FND <br />FOB <br />FOS <br />GA <br />GALV <br />GAR <br />GC <br />GLS <br />GLZ <br />GYPBD <br />HC <br />HB <br />HDR <br />HDW <br />HORIZ <br />HR <br />HT <br />HVAC <br />IBC <br />ID <br />IN <br />INST <br />INSUL <br />INT <br />JB <br />JST <br />JT <br />ABOVE FINISH FLOOR <br />AUTHORITY HAVING JURISDICTION <br />AIR HANDLER UNIT <br />ALTERNATE <br />ALUMINUM <br />APARTMENT <br />BALCONY <br />BELOW FINISH FLOOR <br />BUILDING <br />BLOCKING <br />BEAM <br />BEDROOM <br />BEARING <br />BREEZEWAY <br />BOTTOM <br />CABINET <br />CALCULATION <br />CERAMIC <br />CUBIC FEET PER MINUTE <br />CLEAR FLOOR SPACE <br />CAST IN PLACE <br />CONTROL JOINT <br />CENTER LINE <br />CEILING <br />CLOSET <br />CLEAR <br />CONCRETE MASONRY UNIT <br />COLUMN <br />CONCRETE <br />CONDENSER/CONDENSATE <br />CONTINUOUS <br />CORRIDOR <br />CEMENT PLASTER <br />CARPET <br />CERAMIC TILE <br />COLD WATER <br />DRYER <br />DIAMETER <br />DIMENSION <br />DOWN <br />DINING <br />DEEP <br />DOOR <br />DOWN SPOUT <br />DETAIL <br />DISHWASHER <br />DRAWING <br />EACH <br />ELECTRIC (AL) <br />ELEVATION <br />ENGINEERED) <br />EDGE OF SLAB <br />EQUAL <br />EQUIVALENT <br />ELECTRIC WATER COOLER <br />EXPANSION <br />EXTERIOR <br />EXISTING <br />FIRE ALARM CONTROL PANEL <br />FIRE BLOCKING <br />FLORIDA BUILDING CODE <br />FLOOR DRAIN <br />FINISH ELEVATION <br />FINISHED FLOOR <br />FINISHED) <br />FINGER JOINTED STUDS <br />FLOOR <br />FIELD MEASURE <br />FACE OF MASONRY / CONCRETE <br />FIRE PROTECTION <br />FEET PER MINUTE <br />FIRE RATED <br />FIBER REINFORCED CEMENT PLASTER <br />FIBER REINFORCED PANEL <br />FOOT/FEET <br />FOOTING <br />FOUNDATION <br />FACE OF BEAM <br />FACE OF STUD <br />GAUGE <br />GALVANIZED <br />GARAGE <br />GENERAL CONTRACTOR <br />GLASS <br />GLAZING <br />GYPSUM BOARD <br />HOLLOW CORE <br />HOSE BIBB <br />HEADER <br />HARDWARE <br />HORIZONTAL <br />HOUR <br />HEIGHT <br />HEATING, VENTING & AC <br />INTERNATIONAL BUILDING CODE <br />INTERIOR DESIGN <br />INCH / INCHES <br />INSTALLATION <br />INSULATION (ED) <br />INTERIOR <br />JUNCTION BOX <br />JOIST <br />JOINT <br />KIT I KITCHEN <br />LAM LAMINATE <br />LAV LAVATORY <br />LF I LINEAR FEET <br />LIN LINEN <br />LR LIVING ROOM <br />LT LIGHT <br />MAX MAXIMUM <br />MECH MECHANICAL <br />MEM MEMBRANE <br />MEP I MECHANICAL, ELECTRICAL, PLUMBING <br />MFR (MA.NUFACTURER (ED) <br />MIN i MINIMUM <br />MIR MIRROR <br />MISC MISCELLANEOUS <br />MPH MILES PER HOUR <br />MR MOISTURE RESISTANT <br />MTD MOUNTED <br />MTL METAL <br />NUM/# NUMBER <br />NOM i NOMINAL <br />NRC NOISE REDUCTION CLASS <br />NTS ; NOT TO SCALE <br />OC ON CENTER <br />OCC OCCUPANCY/OCCUPANT <br />OFW OUTSIDE FACE OF WALL <br />OSB ORIENTED STRAND BOARD <br />PAN PANTRY <br />PKG PACKAGE <br />PL AM PLASTIC LAMINATE <br />PLB PLUMB <br />PLMG PLUMBING <br />PLF ' POUNDS PER LINEAR FOOT <br />PLYWD PLYWOOD <br />PRE -EN PRE-ENGINEERED <br />PSF POUNDS PER SQUARE FOOT <br />PSI POUNDS PER SQUARE INCH <br />P-T POST TENSION <br />PT PRESSURE TREATED WOOD <br />PTAC PACKAGE TERMINAL AC <br />PTD PAINTED <br />PVC POLY VINYL CHLORIDE <br />QT QUARRY TILE <br />RAID RADIUS <br />RCP REFLECTED CEILING PLAN <br />REF REFERENCE <br />REFRIG REFRIGERATOR <br />REINF REINFORCE(ED/ING) <br />REQD REQUIRED <br />RM ROOM <br />RO I ROUGH OPENING <br />IRS ROUGH SAWN <br />RSC ROUGH SAWN CEDAR <br />SAN I SANITARY <br />Sc SOLID CORE <br />SCH !SCHEDULE <br />SEP SEPARATION <br />SF SQUARE FEET <br />SGD SLIDING GLASS DOOR <br />SHT SHEET <br />SHTG SHEATHING <br />SIM SIMILAR <br />SOG SLAB ON GRADE <br />SP SPRING POINT <br />SPEC ; SPECIFICATIONS <br />SPF I SPRUCE -PINE -FUR <br />SQ SQUARE <br />SS STAINLESS STEEL <br />STC SOUND TRANSMISSION CLASS <br />STD STANDARD <br />STL STEEL <br />STO STORAGE <br />SW SHEAR WALL <br />SYM SYMMETRICAL <br />SYP SOUTHERN YELLOW PINE <br />T&B TOP & BOTTOM <br />T&G TONGUE & GROOVE <br />TB TOWEL BAR <br />TEMP TEMPERED <br />THK ; THICK <br />TPD I TOILET PAPER DISPENSER <br />TPH TOILET PAPER HOLDER <br />T.O. TOP OF <br />I } TOP OF SLAB <br />TS I TUBE STEEL <br />TYP TYPICAL <br />UL I UNDERWRITERS LABORATORY <br />UNO UNLESS NOTED OTHERWISE <br />VC ! VINYL COVERED <br />VCT VINYL COMPOSITE TILE <br />VER VERIFY <br />VERT VERTICAL <br />VLT VAULT <br />VWC VINYL WALL COVERING <br />W WASHER <br />W/ WITH <br />W/D WASHER/DRYER COMBINATION <br />W/O WITHOUT <br />WC ! WATER CLOSET <br />WD WOOD <br />WDW WINDOW <br />WIC WALK IN CLOSET <br />WH I WATER HEATER <br />1. FLORIDA BUILDING CODE - BUILDING 2007 W/ APPLICABLE SUPPLEMENTS <br />2. FLORIDA BUILDING CODE -MECHANICAL 2007 W/ APPLICABLE SUPPLEMENTS <br />3. FLORIDA BUILDING CODE - PLUMBING 2007 W/ APPLICABLE SUPPLEMENTS <br />4. NATIONAL ELECTRIC CODE 2008 EDITION <br />ACCESSIBILITY: <br />1. FAIRHOUSING ACT DESIGN MANUAL <br />2. FLORIDA ADA (F.B.C.-B. CHAPTER 11 PART "A" WHERE APPLICABLE) <br />LIFE SAFETY: <br />FLORIDA FIRE PREVENTION CODE 2007 EDITION. <br />OCCUPANCY & CONSTRUCTION TYPE <br />OCCUPANCY TYPE A-3 <br />CONSTRUCTION TYPE TYPE V-B, UNSPRINKLERED (EXCEPT LAUNDRY RM) <br />AREA & HEIGHT LIMITATION (FBC-B, Table 503) <br />REQUIRED /ALLOWED <br />PROPOSED <br />MEAN HEIGHT <br />40' <br />17'-8" <br />MAX. NUMBER OF STORIES <br />1 STORY <br />1 STORY <br />MAXIMUM AREA PER FLOOR <br />6,000 S.F. <br />4,376 S.F. <br />0 FIRE PROTECTION (FBC-B, Tables 601 & 602) <br />STRUCTURAL FRAME <br />REQUIRED / ALLOWED <br />PROPOSED <br />INCLUDING COLUMNS, GIRDERS, TRUSSES <br />0 HR <br />0 HR <br />BEARING WALLS <br />EXTERIOR <br />0 HR <br />0 HR <br />INTERIOR <br />0 HR <br />0 HR <br />NON -BEARING WALLS & PARTITIONS <br />EXTERIOR <br />0 HR <br />0 HR <br />INTERIOR <br />0 HR <br />0 HR <br />ROOF CONSTRUCTION <br />INCLUDING SUPPORTING BEAMS & JOISTS <br />0 HR <br />0 HR <br />FIRE SEPARATION @a LAUNDRY (FFPC 12.3.2.1.2 (2)) 1 HR 1 HR <br />W/ SPRINKLERS W/ SPRINKLERS <br />OCCUPANCY & MEANS OF EGRESS (FBC-B, Chapter 10) <br />OCCUPANCY LOAD (PER 1004.1.2.F.B.C.) <br />GROUP: A3 <br />ASSEMBLY <br />FLOOR AREA PER OCC. <br />OCCUPANTS <br />CLUBROOM <br />660 SQ.FT. / 15 SQ.FT. <br />44 PERSONS <br />FITNESS ROOM <br />466 SQ.FT. / 50 SQ.FT. <br />9 PERSONS <br />ACTIVITY ROOM <br />406 SQ.FT. / 15 SQ.FT. <br />27 PERSONS <br />(INCLUDES: ACTIVITY ROOM & EXAM ROOM) <br />BUSINESS <br />LAUNDRY <br />167 SQ.FT. /100 SQ.FT. <br />2 PERSONS <br />I EASING OFFICE <br />835 SQ.FT. /100 SQ.FT. <br />8 PERSONS <br />(INCLUDES: BUSINESS CENTER, CONFERENCE ROOM, <br />MANAGER'S OFFICE, & LEASING OFFICE) <br />TOTAL <br />90 PERSONS <br />EXITING REQUIREMENTS (PER 1019.1) <br />TRAVEL DISTANCE (PER 1015.1) <br />WORST CASE FROM CONFERENCE <br />ROOM TO OUT OF BUILDING <br />PLUMBING FIXTURE CALCULATION <br />PER TABLE 403.1 & 403.8 F.B.C.-P <br />TOTAL OCCUPANTS: 90 OCCUPANTS <br />ASSUMING 50% WOMEN: 45 OCCUPANTS <br />ASSUMING 50% MEN: 45 OCCUPANS <br />REQUIRED / ALLOWED PROVIDED <br />2 2 <br />ALLOWED PROVIDED <br />150 L.F. 72 L.F. <br />FIXTURE REQUIRED PROVIDED <br />WC <br />(1 PER 125) 1 1 <br />LAVATORIES <br />(1 PER 200) 1 2 <br />URINAL 1 2 <br />WOMENS ROOM <br />(1 PER 125) 1 3 <br />LAVATORIES <br />(1 PER 200) 1 3 <br />JANITORY ROOM <br />MOP SINK 1 1 <br />WATER COOLER 1 2 <br />RESTROOMS COMPLY WITH TABLE 403.8 F.B.C.-P FOR SWIMMING POOLS NOT GREATER THAN <br />2,500 SQ.FT. <br />■ CLUBHOUSE AREA SUMMARY <br />A/C AREA <br />NON A/C AREA <br />TOTAL <br />3,616 S.F. <br />760 S.F. <br />4,376 S.F. <br />INTERIOR WALL & CEILING FINISHES <br />REQUIRED BY OCCUPANCY (TABLE 803.5 F.B.G.) <br />-VERTICAL EXIT & EXIT PASSAGE WAY =A <br />-EXIT ACCESS =A <br />-ROOM & ENCLOSED SPACES =C <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />PLANNING I ARCHITECTURE I INTERIOR DESIGN <br />745 orienta avenue, suite 1121 <br />altamonte springs, fl 32701 <br />phone: 407.830.1400 <br />fax: 407.830.4143 <br />AA0002731 <br />www,forumarchitectu re. com <br />Fort King <br />Colony <br />Apartments <br />City of Zephyrhills, FL <br />Q SHEET REVISIONS: <br />EDITED BY: JT <br />! PROJECT NO. <br />10-2651 <br />Al T02 <br />