e <br />T <br />CD <br />U <br />a <br />00 <br />N <br />fO <br />0 <br />N <br />0 <br />P <br />Q <br />04 <br />M <br />00 <br />C <br />0 <br />0 <br />v <br />FIRE EXTINGUISHER ® GENERAL DATA <br />01 PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN EACH BUILDING AS REQUIRED AND SPECIFIED IN 01 CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE CODES AND MUST NOTIFY <br />NFPA 10, CHAPTER 3. PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED IN LOCATIONS INDICATED ON THE ARCHITECT OF DISCREPANCIES INDICATED BY THESE DOCUMENTS FOUND DURING BIDDING AND PRIOR TO <br />DRAWINGS OR AT A MINIMUM OF (1) FIRE EXTINGUISHER PER OVERALL GENERAL BUILDING AREA. FIRE PROCEEDING WITH THE WORK. <br />EXTINGUISHERS SHALL BE LOCATED WITH A MAXIMUM TRAVEL DISTANCE OF 75 FEET TO THE EXTINGUISHER <br />OR AS REQUIRED BY LOCAL AUTHORITIES HAVING JURISDICTION. EACH EXTINGUISHER TO HAVE A MINIMUM 02 DRAWINGS ARE DEVELOPED TO ILLUSTRATE SIZE, ASSEMBLY, RELATIONSHIP, QUANTITY, AND IDENTIFICATION <br />RATING OF 2A:10B-C, UNO. OF BUILDING COMPONENTS. DOCUMENTS WORK IN CONJUNCTION WITH SPECIFICATIONS REGARDING EXACT <br />REQUIREMENTS OF PRODUCTS, INSTALLATION QUALITY, STANDARD EXECUTION OF WORK, AND <br />WINDOWS & DOORS CLASSIFICATIONS. <br />01 ALL EXTERIOR WINDOWS AND DOORS SHALL BE SEALED AND WEATHER STRIPPED. WINDOW UNITS SHALL 03 ALL TRADES MUST REVIEW ALL CONSTRUCTION DOCUMENTS AND ARE RESPONSIBLE FOR ALL WORK <br />DISPLAY LABELS SHOWING COMPLIANCE WITH STATE ENERGY CODE. ASSOCIATED WITH THEIR TRADES IN THESE DOCUMENTS. DO NOT BASE SCOPE OF WORK ONLY ON A REVIEW <br />OF THE SHEETS TYPICALLY ASSOCIATED WITH THE TRADE'S SCOPE OF WORK. <br />02 HINGES ON EXTERIOR OUT SWINGING DOORS SHALL HAVE NON -REMOVABLE PINS AND NON -EXPOSED <br />SCREWS. 04 DO NOT SCALE DRAWINGS. USE ONLY WRITTEN DIMENSIONS. <br />03 GLASS AT EXTERIOR DOORS SHALL COMPLY WITH ANSI 297.1. <br />04 VISION PANEL EXTERIOR DOORS OTHER THAN GLAZING WITHIN 40" OF THE INSIDE LOCK ACTIVATING DEVICE <br />OF LOOSE AND SWING DOORS SHALL COMPLY WITH ANSI 297.1. <br />05 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS, SHALL VERIFY EXISTING <br />TOPOGRAPHY AND GRADE ELEVATIONS, AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO <br />PROCEEDING WITH THE PROJECT. <br />06 <br />THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR AND HAVE CONTROL OVER CONSTRUCTION MEANS, <br />05 <br />INDIVIDUAL GLAZED AREAS, INCLUDING GLASS MIRRORS, IN HAZARDOUS LOCATIONS AS DEFINED BY THE <br />METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING ALL SAFETY PRECAUTIONS ANDPROGRAMS, <br />BUILDING CODE SHALL HAVE SAFETY GLAZING MATERIAL IN COMPLIANCE WITH THE BUILDING CODE. <br />AND FOR COORDINATING ALL PORTIONS OF THE WORK. <br />06 <br />ALL EQUIPMENT AND HARDWARE, WHERE APPLICABLE, SHALL MEET ALL FEDERAL, STATE AND LOCAL <br />07 <br />ADDRESSES: APPROVED NUMBERS OR ADDRESSES SHALL BE PROVIDED FOR THE BUILDINGS SO THAT THE <br />GUIDELINES FOR ACCESSIBILITY. <br />NUMBERS OR ADDRESS IS PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROADWAY. THE NUMBERS <br />SHALL CONTRAST WITH THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE DETERMINED BY THE OWNER. <br />07 <br />ALL WINDOWS SHALL BEAR THE APPROVED LABEL WITH CORRECT PRESSURES LISTED AND BEAR A WDMA OR <br />OTHER APPROVED LABEL IDENTIFYING THE MANUFACTURER, PERFORMANCE CHARACTERISTICS AND <br />08 <br />DIMENSIONS SHOWN ARE TO FACE OF CONCRETE MASONRY UNITS, FACE OF STUD, MASONRY OPENING, OR <br />APPROVED PRODUCT EVALUATION ENTITY TO INDICATE COMPLIANCE WITH THE REQUIREMENTS OF <br />ROUGH OPENING AT STUD WALLS. <br />AAMAIWOMA 101/I.S.2.NAFS. <br />09 <br />THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND SUBMITTING PRODUCT APPROVAL SHEETS AND DATA <br />08 <br />ENERGY STAR RATING IS REQUIRED FOR ALL WINDOWS. <br />TO THE BUILDING DEPARTMENT IN THE FORM THE BUILDING DEPARTMENT REQUIRES FOR ANY PRODUCT <br />SELECTION THAT IS CHANGED BY THE OWNER AND/OR THE CONTRACTOR FROM THE PRODUCT ORIGINALLY <br />FLOORING <br />SPECIFIED AND SUBMITTED BY THE ARCHITECT. THE CONTRACTOR MUST FIRST SUBMIT THE NEW PRODUCT <br />01 <br />SEE INTERIOR FINISH SCHEDULE FOR FLOOR FINISHES. <br />DATA TO THE ARCHITECT FOR REVIEW AND APPROVAL BEFORE SUBMITTING THE REQUIRED PRODUCT <br />APPROVAL SHEETS AND DATA TO THE BUILDING DEPARTMENT. <br />02 <br />ALL INTERIOR FLOOR FINISHES SHALL NOT BE LESS THAN CLASS II PER NFPA 253. <br />10 <br />ANY ERRORS, OMISSIONS OR INCONSISTENCIES DISCOVERED IN THE DOCUMENTS, OR ANY VARIATION OR <br />03 <br />CARPET AND RUG INSTITUTE GREEN LABEL CERTIFIED CARPET & PAD FOR ALL CARPET PROVIDED. <br />AMBIGUITIES BETWEEN THESE DRAWINGS AND ACTUAL SITE AND CONSTRUCTION CONDITIONS AND/OR <br />REQUIREMENTS, SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. IF A DISCREPANCY IS FOUND IN <br />PAINTING <br />THE CONTRACT DOCUMENTS, THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY IN WRITING. <br />01 <br />SEE INTERIOR DESIGN FINISH SCHEDULE FOR PAINT SPECIFICATIONS. <br />11 <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING AN IDENTIFYING SYMBOL ON <br />STRUCTURES CONSTRUCTED WITH A LIGHT -FRAME TRUSS COMPONENT IN A MANNER SUFFICIENT TO COMPLY <br />02 <br />ALL EXTERIOR VENTS AND EQUIPMENT THAT ARE VISIBLE ON EXTERIOR OF BUILDING SHALL BE PAINTED A <br />WITH THE STATE OF FLORIDA FIRE MARSHAL'S OFFICE IN ACCORDANCE WITH FLORIDA STATUTE 633.027, PER <br />COLOR TO MATCH THE ADJACENT SURFACE, UNO. <br />THE REQUIREMENTS OF THE FLORIDA ADMINISTRATIVE CODE RULE 69A-60.0081, AND AS DETERMINED BY THE <br />AUTHORITY HAVING JURISDICTION, CONTRACTOR TO VERIFY FINAL LOCATION WITH AHJ. <br />03 <br />ALL COLOR TRANSITIONS SHALL BE ON THE INSIDE CORNERS, UNO. <br />SITE WORK <br />04 <br />CONTACT THE OWNER OR ARCHITECT PRIOR TO PAINTING IF QUESTIONS ARISE. <br />01 <br />SOIL BEARING VALUES, FOUNDATION DESIGNS ARE BASED ON AN ESTIMATED SOIL BEARING VALUE OR <br />05 <br />LOW VOC PAINT IS REQUIRED IN ALL INTERIOR COMMON AREAS. <br />ACTUAL VALUE AS SPECIFIED BY A GEOTECHNICAL ENGINEER AND NOTED ON THE DRAWINGS. FOUNDATIONS <br />AND SLABS ARE DESIGNED TO UNIFORMLY BEAR ON WELL COMPACTED, WELL DRAINED NON -EXPANSIVE <br />SHELVING <br />SOILS. A CERTIFIED SOILS ENGINEER SHALL REVIEW FOUNDATION DESIGNS, BUILDING LOADS, AND COMPARE <br />WITH SUBSURFACE SOIL INVESTIGATION RECOMMENDATIONS. SHOULD ON -SITE OBSERVATIONS SHOW THAT <br />01 <br />ALL SHELVING TO BE VINYL COATED WIRE SHELVING, UNO. <br />FOOTINGS SHOWN HERE ARE NOT SATISFACTORY, THE ARCHITECT SHALL BE CONTACTED IMMEDIATELY FOR <br />REVISED DESIGNS. <br />CABINETS <br />02 <br />THE CONTRACTOR SHALL PROVIDE ALL OF THE FOLLOWING SITE REQUIRED ITEMS, BUT NOT LIMITED TO: SITE <br />01 <br />GC TO FIELD VERIFY FINISH TO FINISH DIMENSIONS PRIOR TO FABRICATION OF CABINETS. <br />UTILITIES, SLEEVES, CONDUIT, PULL BOXES, STRUCTURAL BASES, FOOTINGS, ETC. DESCRIBED OR REQUIRED <br />AS PART OF A COMPLETE SYSTEM ON CIVIL ENGINEERING, LANDSCAPE, SWIMMING POOL, ARCHITECTURAL, <br />02 <br />FINISH ALL EXPOSED CABINET ENDS. <br />STRUCTURAL, MECHANICAL, ELECTRICAL OR PLUMBING DRAWINGS. COORDINATE FULLY WITH ALL UTILITY <br />03 <br />KITCHENETTE CABINETS TO BE 24" DEEP WITH 25" TOPS, UNO. <br />COMPANIES TO DETERMINE WHAT COMPONENTS ARE PROVIDED BY THE UTILITY COMPANIES. THE GENERAL <br />CONTRACTOR IS RESPONSIBLE FOR ALL ITEMS NOT SUPPLIED BY THE UTILITY COMPANY. <br />APPLIANCES <br />03 <br />REFER TO CIVIL ENGINEERS SITE PLAN AND DETAILS FOR ACTUAL BUILDING LOCATIONS, FINISHED GRADES, <br />01 <br />ENERGY STAR RATING REQUIRED FOR ALL REFRIGERATORS, DISHWASHERS & WASHING MACHINES PROVIDED. <br />FLOOR ELEVATIONS, UTILITIES, DRAINAGE, ETC. <br />04 <br />REFER TO LANDSCAPE ARCHITECT AND/OR POOL DESIGNER'S PLANS FOR LANDSCAPING, FENCES, POOL <br />DESIGN, IRRIGATION, EXTERIOR FURNISHINGS, TRAFFIC CONTROL, AND OTHER DECORATIVE LIGHT FIXTURES, <br />ETC. <br />05 CLEARANCE BETWEEN EXTERIOR WALL COVERINGS AND FINAL GRADE ON THE EXTERIOR OF BUILDING SHALL <br />NOT BE LESS THAN 6 INCHES, (U.N.O.) <br />06 NOTICE OF TERMITE PROTECTION. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT <br />PROVIDER AND NEED FOR REINSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE <br />SIGN SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRICAL PANEL. <br />® TERMITE PROTECTION <br />01 ALL BUILDINGS SHALL HAVE PRE -CONSTRUCTION PROTECTION AGAINST SUBTERRANEAN TERMITES APPLIED <br />UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN 1'-0" OF THE PRIMARY STRUCTURE SIDE WALLS AS <br />REQUIRED BY THE APPLICABLE BUILDING CODE, <br />02 THE CONTRACTOR IS RESPONSIBLE TO PROVIDE AND INSTALL TERMITE PROTECTION AS REQUIRED BY ALL <br />APPLICABLE CODES AND PER MANUFACTURER'S RECOMMENDATIONS. <br />03 A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR REINSPECTION <br />AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER <br />HEATER OR ELECTRICAL PANEL. <br />04 ALL CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 1'-0" AWAY FROM BUILDING SIDE <br />WALLS. <br />N GYPSUM BOARD <br />01 ALL INTERIOR NON -RATED WALL CONSTRUCTION TO HAVE 1/2" REGULAR GYPSUM BOARD, UNO <br />02 ALL INTERIOR FRAMED FIRE -RATED WALL CONSTRUCTION TO HAVE 5/8" FIRE -RATED GYPSUM BOARD, UNO <br />03 GYPSUM BOARD INSTALLATION SHALL BE IN CONFORMANCE WITH THE GYPSUM ASSOCIATIONS <br />RECOMMENDED PRACTICES FOR THICKNESS, ATTACHMENT, TAPING, FINISHING AND STUD SPACING. <br />04 GYPSUM BOARD USED IN A FIRE RATED ASSEMBLY SHALL CONFORM EXACTLY TO THE REQUIREMENTS OF THE <br />ASSEMBLY LISTED. <br />0 <br />.y <br />FORUME <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />PLANNING I ARCHITECTURE I INTERIOR DESIGN <br />745 orienta avenue, suite 1121 <br />altamonte springs, fl 32701 <br />phone: 407.830.1400 <br />fax: 407.830.4143 <br />AA0002731 <br />www.forumarchitecture.com <br />Fort King <br />Colony <br />Apartments <br />City of Zephyrhills, FL <br />m O <br />wIX <br />Q¢ <br />SET DISTRIBUTIONS: <br />EDITED BY: JT <br />PROJECT NO. 10-2651 <br />Clubhouse <br />General Notes <br />Al 7,03 <br />