<br />FIRE EXTINGUISHER ® GENERAL DATA
<br />01 PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN EACH BUILDING AS REQUIRED AND SPECIFIED IN 01 CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE CODES AND MUST NOTIFY
<br />NFPA 10, CHAPTER 3. PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED IN LOCATIONS INDICATED ON THE ARCHITECT OF DISCREPANCIES INDICATED BY THESE DOCUMENTS FOUND DURING BIDDING AND PRIOR TO
<br />DRAWINGS OR AT A MINIMUM OF (1) FIRE EXTINGUISHER PER OVERALL GENERAL BUILDING AREA. FIRE PROCEEDING WITH THE WORK.
<br />EXTINGUISHERS SHALL BE LOCATED WITH A MAXIMUM TRAVEL DISTANCE OF 75 FEET TO THE EXTINGUISHER
<br />OR AS REQUIRED BY LOCAL AUTHORITIES HAVING JURISDICTION. EACH EXTINGUISHER TO HAVE A MINIMUM 02 DRAWINGS ARE DEVELOPED TO ILLUSTRATE SIZE, ASSEMBLY, RELATIONSHIP, QUANTITY, AND IDENTIFICATION
<br />RATING OF 2A:10B-C, UNO. OF BUILDING COMPONENTS. DOCUMENTS WORK IN CONJUNCTION WITH SPECIFICATIONS REGARDING EXACT
<br />REQUIREMENTS OF PRODUCTS, INSTALLATION QUALITY, STANDARD EXECUTION OF WORK, AND
<br />WINDOWS & DOORS CLASSIFICATIONS.
<br />01 ALL EXTERIOR WINDOWS AND DOORS SHALL BE SEALED AND WEATHER STRIPPED. WINDOW UNITS SHALL 03 ALL TRADES MUST REVIEW ALL CONSTRUCTION DOCUMENTS AND ARE RESPONSIBLE FOR ALL WORK
<br />DISPLAY LABELS SHOWING COMPLIANCE WITH STATE ENERGY CODE. ASSOCIATED WITH THEIR TRADES IN THESE DOCUMENTS. DO NOT BASE SCOPE OF WORK ONLY ON A REVIEW
<br />OF THE SHEETS TYPICALLY ASSOCIATED WITH THE TRADE'S SCOPE OF WORK.
<br />02 HINGES ON EXTERIOR OUT SWINGING DOORS SHALL HAVE NON -REMOVABLE PINS AND NON -EXPOSED
<br />SCREWS. 04 DO NOT SCALE DRAWINGS. USE ONLY WRITTEN DIMENSIONS.
<br />03 GLASS AT EXTERIOR DOORS SHALL COMPLY WITH ANSI 297.1.
<br />04 VISION PANEL EXTERIOR DOORS OTHER THAN GLAZING WITHIN 40" OF THE INSIDE LOCK ACTIVATING DEVICE
<br />OF LOOSE AND SWING DOORS SHALL COMPLY WITH ANSI 297.1.
<br />05 THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS, SHALL VERIFY EXISTING
<br />TOPOGRAPHY AND GRADE ELEVATIONS, AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO
<br />PROCEEDING WITH THE PROJECT.
<br />06
<br />THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR AND HAVE CONTROL OVER CONSTRUCTION MEANS,
<br />05
<br />INDIVIDUAL GLAZED AREAS, INCLUDING GLASS MIRRORS, IN HAZARDOUS LOCATIONS AS DEFINED BY THE
<br />METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING ALL SAFETY PRECAUTIONS ANDPROGRAMS,
<br />BUILDING CODE SHALL HAVE SAFETY GLAZING MATERIAL IN COMPLIANCE WITH THE BUILDING CODE.
<br />AND FOR COORDINATING ALL PORTIONS OF THE WORK.
<br />06
<br />ALL EQUIPMENT AND HARDWARE, WHERE APPLICABLE, SHALL MEET ALL FEDERAL, STATE AND LOCAL
<br />07
<br />ADDRESSES: APPROVED NUMBERS OR ADDRESSES SHALL BE PROVIDED FOR THE BUILDINGS SO THAT THE
<br />GUIDELINES FOR ACCESSIBILITY.
<br />NUMBERS OR ADDRESS IS PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROADWAY. THE NUMBERS
<br />SHALL CONTRAST WITH THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE DETERMINED BY THE OWNER.
<br />07
<br />ALL WINDOWS SHALL BEAR THE APPROVED LABEL WITH CORRECT PRESSURES LISTED AND BEAR A WDMA OR
<br />OTHER APPROVED LABEL IDENTIFYING THE MANUFACTURER, PERFORMANCE CHARACTERISTICS AND
<br />08
<br />DIMENSIONS SHOWN ARE TO FACE OF CONCRETE MASONRY UNITS, FACE OF STUD, MASONRY OPENING, OR
<br />APPROVED PRODUCT EVALUATION ENTITY TO INDICATE COMPLIANCE WITH THE REQUIREMENTS OF
<br />ROUGH OPENING AT STUD WALLS.
<br />AAMAIWOMA 101/I.S.2.NAFS.
<br />09
<br />THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND SUBMITTING PRODUCT APPROVAL SHEETS AND DATA
<br />08
<br />ENERGY STAR RATING IS REQUIRED FOR ALL WINDOWS.
<br />TO THE BUILDING DEPARTMENT IN THE FORM THE BUILDING DEPARTMENT REQUIRES FOR ANY PRODUCT
<br />SELECTION THAT IS CHANGED BY THE OWNER AND/OR THE CONTRACTOR FROM THE PRODUCT ORIGINALLY
<br />FLOORING
<br />SPECIFIED AND SUBMITTED BY THE ARCHITECT. THE CONTRACTOR MUST FIRST SUBMIT THE NEW PRODUCT
<br />01
<br />SEE INTERIOR FINISH SCHEDULE FOR FLOOR FINISHES.
<br />DATA TO THE ARCHITECT FOR REVIEW AND APPROVAL BEFORE SUBMITTING THE REQUIRED PRODUCT
<br />APPROVAL SHEETS AND DATA TO THE BUILDING DEPARTMENT.
<br />02
<br />ALL INTERIOR FLOOR FINISHES SHALL NOT BE LESS THAN CLASS II PER NFPA 253.
<br />10
<br />ANY ERRORS, OMISSIONS OR INCONSISTENCIES DISCOVERED IN THE DOCUMENTS, OR ANY VARIATION OR
<br />03
<br />CARPET AND RUG INSTITUTE GREEN LABEL CERTIFIED CARPET & PAD FOR ALL CARPET PROVIDED.
<br />AMBIGUITIES BETWEEN THESE DRAWINGS AND ACTUAL SITE AND CONSTRUCTION CONDITIONS AND/OR
<br />REQUIREMENTS, SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. IF A DISCREPANCY IS FOUND IN
<br />PAINTING
<br />THE CONTRACT DOCUMENTS, THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY IN WRITING.
<br />01
<br />SEE INTERIOR DESIGN FINISH SCHEDULE FOR PAINT SPECIFICATIONS.
<br />11
<br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING AN IDENTIFYING SYMBOL ON
<br />STRUCTURES CONSTRUCTED WITH A LIGHT -FRAME TRUSS COMPONENT IN A MANNER SUFFICIENT TO COMPLY
<br />02
<br />ALL EXTERIOR VENTS AND EQUIPMENT THAT ARE VISIBLE ON EXTERIOR OF BUILDING SHALL BE PAINTED A
<br />WITH THE STATE OF FLORIDA FIRE MARSHAL'S OFFICE IN ACCORDANCE WITH FLORIDA STATUTE 633.027, PER
<br />COLOR TO MATCH THE ADJACENT SURFACE, UNO.
<br />THE REQUIREMENTS OF THE FLORIDA ADMINISTRATIVE CODE RULE 69A-60.0081, AND AS DETERMINED BY THE
<br />AUTHORITY HAVING JURISDICTION, CONTRACTOR TO VERIFY FINAL LOCATION WITH AHJ.
<br />03
<br />ALL COLOR TRANSITIONS SHALL BE ON THE INSIDE CORNERS, UNO.
<br />SITE WORK
<br />04
<br />CONTACT THE OWNER OR ARCHITECT PRIOR TO PAINTING IF QUESTIONS ARISE.
<br />01
<br />SOIL BEARING VALUES, FOUNDATION DESIGNS ARE BASED ON AN ESTIMATED SOIL BEARING VALUE OR
<br />05
<br />LOW VOC PAINT IS REQUIRED IN ALL INTERIOR COMMON AREAS.
<br />ACTUAL VALUE AS SPECIFIED BY A GEOTECHNICAL ENGINEER AND NOTED ON THE DRAWINGS. FOUNDATIONS
<br />AND SLABS ARE DESIGNED TO UNIFORMLY BEAR ON WELL COMPACTED, WELL DRAINED NON -EXPANSIVE
<br />SHELVING
<br />SOILS. A CERTIFIED SOILS ENGINEER SHALL REVIEW FOUNDATION DESIGNS, BUILDING LOADS, AND COMPARE
<br />WITH SUBSURFACE SOIL INVESTIGATION RECOMMENDATIONS. SHOULD ON -SITE OBSERVATIONS SHOW THAT
<br />01
<br />ALL SHELVING TO BE VINYL COATED WIRE SHELVING, UNO.
<br />FOOTINGS SHOWN HERE ARE NOT SATISFACTORY, THE ARCHITECT SHALL BE CONTACTED IMMEDIATELY FOR
<br />REVISED DESIGNS.
<br />CABINETS
<br />02
<br />THE CONTRACTOR SHALL PROVIDE ALL OF THE FOLLOWING SITE REQUIRED ITEMS, BUT NOT LIMITED TO: SITE
<br />01
<br />GC TO FIELD VERIFY FINISH TO FINISH DIMENSIONS PRIOR TO FABRICATION OF CABINETS.
<br />UTILITIES, SLEEVES, CONDUIT, PULL BOXES, STRUCTURAL BASES, FOOTINGS, ETC. DESCRIBED OR REQUIRED
<br />AS PART OF A COMPLETE SYSTEM ON CIVIL ENGINEERING, LANDSCAPE, SWIMMING POOL, ARCHITECTURAL,
<br />02
<br />FINISH ALL EXPOSED CABINET ENDS.
<br />STRUCTURAL, MECHANICAL, ELECTRICAL OR PLUMBING DRAWINGS. COORDINATE FULLY WITH ALL UTILITY
<br />03
<br />KITCHENETTE CABINETS TO BE 24" DEEP WITH 25" TOPS, UNO.
<br />COMPANIES TO DETERMINE WHAT COMPONENTS ARE PROVIDED BY THE UTILITY COMPANIES. THE GENERAL
<br />CONTRACTOR IS RESPONSIBLE FOR ALL ITEMS NOT SUPPLIED BY THE UTILITY COMPANY.
<br />APPLIANCES
<br />03
<br />REFER TO CIVIL ENGINEERS SITE PLAN AND DETAILS FOR ACTUAL BUILDING LOCATIONS, FINISHED GRADES,
<br />01
<br />ENERGY STAR RATING REQUIRED FOR ALL REFRIGERATORS, DISHWASHERS & WASHING MACHINES PROVIDED.
<br />FLOOR ELEVATIONS, UTILITIES, DRAINAGE, ETC.
<br />04
<br />REFER TO LANDSCAPE ARCHITECT AND/OR POOL DESIGNER'S PLANS FOR LANDSCAPING, FENCES, POOL
<br />DESIGN, IRRIGATION, EXTERIOR FURNISHINGS, TRAFFIC CONTROL, AND OTHER DECORATIVE LIGHT FIXTURES,
<br />ETC.
<br />05 CLEARANCE BETWEEN EXTERIOR WALL COVERINGS AND FINAL GRADE ON THE EXTERIOR OF BUILDING SHALL
<br />NOT BE LESS THAN 6 INCHES, (U.N.O.)
<br />06 NOTICE OF TERMITE PROTECTION. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT
<br />PROVIDER AND NEED FOR REINSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE
<br />SIGN SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRICAL PANEL.
<br />® TERMITE PROTECTION
<br />01 ALL BUILDINGS SHALL HAVE PRE -CONSTRUCTION PROTECTION AGAINST SUBTERRANEAN TERMITES APPLIED
<br />UNDER ALL EXTERIOR CONCRETE OR GRADE WITHIN 1'-0" OF THE PRIMARY STRUCTURE SIDE WALLS AS
<br />REQUIRED BY THE APPLICABLE BUILDING CODE,
<br />02 THE CONTRACTOR IS RESPONSIBLE TO PROVIDE AND INSTALL TERMITE PROTECTION AS REQUIRED BY ALL
<br />APPLICABLE CODES AND PER MANUFACTURER'S RECOMMENDATIONS.
<br />03 A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR REINSPECTION
<br />AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER
<br />HEATER OR ELECTRICAL PANEL.
<br />04 ALL CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 1'-0" AWAY FROM BUILDING SIDE
<br />WALLS.
<br />N GYPSUM BOARD
<br />01 ALL INTERIOR NON -RATED WALL CONSTRUCTION TO HAVE 1/2" REGULAR GYPSUM BOARD, UNO
<br />02 ALL INTERIOR FRAMED FIRE -RATED WALL CONSTRUCTION TO HAVE 5/8" FIRE -RATED GYPSUM BOARD, UNO
<br />03 GYPSUM BOARD INSTALLATION SHALL BE IN CONFORMANCE WITH THE GYPSUM ASSOCIATIONS
<br />RECOMMENDED PRACTICES FOR THICKNESS, ATTACHMENT, TAPING, FINISHING AND STUD SPACING.
<br />04 GYPSUM BOARD USED IN A FIRE RATED ASSEMBLY SHALL CONFORM EXACTLY TO THE REQUIREMENTS OF THE
<br />ASSEMBLY LISTED.
<br />0
<br />.y
<br />FORUME
<br />ARCHITECTURE &
<br />INTERIOR DESIGN, INC.
<br />PLANNING I ARCHITECTURE I INTERIOR DESIGN
<br />745 orienta avenue, suite 1121
<br />altamonte springs, fl 32701
<br />phone: 407.830.1400
<br />fax: 407.830.4143
<br />AA0002731
<br />www.forumarchitecture.com
<br />Fort King
<br />Colony
<br />Apartments
<br />City of Zephyrhills, FL
<br />m O
<br />wIX
<br />Q¢
<br />SET DISTRIBUTIONS:
<br />EDITED BY: JT
<br />PROJECT NO. 10-2651
<br />Clubhouse
<br />General Notes
<br />Al 7,03