H,V.A® . GENERAL NOTES <br />1. IF, THROUGH ERRORS OR, OMISSIONS THE INTENT OF ARCH,ri-ECT/ENGINEER WITH REGARD <br />TO ANY DETAIL IS NOT CLEAR, OR CAPABLE OF MORE THAN ONE INTERPRETATION, SUCH <br />MATTERS WILL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER IN WRITING <br />BEFORE THE SUBMISSION OF BIDS, AND THE ARCHITECT/ENGINEER SHALL MAKE <br />CORRECTIONS EXPLANATIONS OR, CLARIFICATIONS IN WRITING. NO EXTRA CHARGE WILL BE <br />ALLOWED FOR THE WORK OR MATERIAL WHICH THE ARCHITECT/ENGINEER WILL REQUIRE, <br />PROVIDED THAT IT COMES WITHIN A REASONABLE INTERPRETATION OF THE DRAWINGS AND <br />SPECIFICATIONS. <br />2. THE PLANS AND SPECIFICATIONS ARE INTENDED AS A GENERAL DESCRIPTION OF THE <br />WORK TO BE PERFORMED. ALL ITEMS NOT SPECIFICALLY MENTIONED OR INDICATED, BUT <br />NECESSARY FOR THE COMPLETION OF THE INSTALLATION SHALL BE FURNISHED AND <br />INSTALLED BY THIS CONTRACTOR. THIS CONTRACTOR SHALL THOROUGHLY ACQUAINT <br />THEMSELVES WITH THE MECHANICAL, ARCHITECTURAL, STRUCTURAL AND ELECTRICAL PLANS <br />BEFORE SUBMITTING HIS/HER FINAL BID. NO ADDITIONAL COMPENSATION WILL BE <br />ALLOWED DUE TO THE CONTRACTOR'S FAILURE TO FAMILIARIZE THEMSELVES WITH THE <br />PLANS. <br />3. ALL WORK SHALL BE IN ACCORDANCE WITH THE 'FLORIDA MECHANICAL CODE 2007 WITH <br />2009 SUPPLEMENTS - MECHANICAL! AND ALL LOCAL CODES. <br />4. REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN (IF APPLICABLE) FOR THE <br />EXACT LOCATION OF AIR DISTRIBUTION DEVICES. <br />5. THE SIZE AND LOCATION OF EQUIPMENT INSTALLED UNDER DIVISION 23 - MECHANICAL <br />SHALL BE COORDINATED WITH ALL OTHER TRADES. <br />6. OPERABLE THERMOSTAT PARTS SHALL BE MOUNTED 48" ABOVE FINISHED FLOOR. <br />THERMOSTATS SHALL BE FURNISHED WITH A TRANSPARENT VANDAL PROOF LOCKING <br />COVER. VOLTAGE SHALL BE 24 VOLT UNLESS OTHERWISE INDICATED. <br />7. DISCONNECT SWITCHES REQUIRED FOR THE MECHANICAL EQUIPMENT SHALL BE PROVIDED <br />BY DIVISION 26 - ELECTRICAL UNLESS INDICATED OTHERWISE ON SCHEDULE. <br />8. CONTROL WIRING AND HARDWARE TO COMPLETE THE HVAC CONTROL SYSTEM SHALL BE <br />FURNISHED AND INSTALLED UNDER DIVISION 23 - MECHANICAL INDICATED ON THESE <br />CONTRACT DOCUMENTS UNLESS OTHERWISE NOTED ON DRAWINGS. <br />9. DUCTWORK SHALL BE CONSTRUCTED AND INSTALLED IN STRICT ACCORDANCE WITH NFPA <br />90A AND 90B. <br />10. DUCT BENDS FROM VERTICAL TO THE HORIZONTAL AND ANGLED TURNS OF DUCTWORK <br />SHALL HAVE TURNING VANES INSTALLED. <br />11. DUCT SIZES SHOWN ARE MINIMUM INSIDE DIMENSIONS. <br />12. AIR-CONDITIONING SUPPLY AND, RETURN AIR DUCTWORK WITHIN ATTIC SPACES SHALL BE <br />1-1/2" R-6.0 FIBERGLASS DUCT BOARD, CLASS 1 AIR DUCT IN STRICT ACCORDANCE <br />WITH UL 181. DUCT BOARD SHALL BE475EI OR 800EI AS PRESCRIBED BY SMACNA <br />DEPENDING ON THE DUCT SIZE. <br />13. PAINT INSIDE DUCT SURFACE AND PORTIONS OF STRUCTURE AND CEILING ASSEMBLY <br />VISIBLE THROUGH GRILLES AND REGISTERS WITH FLAT BLACK PAINT. <br />14. PIPE AND DUCT ROUTING INDICATED IS SCHEMATIC. HVAC CONTRACTOR SHALL PROVIDE <br />ANY ADDITIONAL OFFSETS AND FITTINGS, INCLUDING BUT NOT LIMITED TO DIVIDED DUCTS <br />REQUIRED FOR PROPER INSTALLATION AND TO ACCOMMODATE CLEARANCES AND, <br />CONFLICTS AS ENCOUNTERED IN THE FIELD. <br />15. FLEXIBLE DUCTWORK SHALL BE: TYPE INL-25 AS MANUFACTURED BY OWENS-CORNING <br />FIBERGLASS CORP. OR EQUIVALENT, SUPPORTED WITH 1 1/2" SHEET METAL STRAPS AT <br />5'-0" ON CENTERS. <br />16. EXHAUST DUCTWORK SHALL BE UNINSULATED GALVANIZED STEEL. <br />17. EXHAUST FAN DISCHARGE POINTS SHALL BE INSTALLED A MINIMUM OF 10'-O" FROM ALL <br />FRESH AIR INTAKE POINTS. <br />18. COORDINATE WITH ALL THE TRADES PRIOR TO PURCHASING OR INSTALLING EQUIPMENT <br />AND MATERIALS. <br />19. COORDINATE HVAC SYSTEM DRAWINGS WITH TRUSS MANUFACTURER DURING SHOP <br />DRAWING REVIEW TO AVOID INTERFERENCE'S BETWEEN MECHANICAL SYSTEMS AND ROOF <br />STRUCTURE. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH <br />TRUSS INTERFERENCE'S THAT OCCUR IN THE FIELD DURING CONSTRUCTION. COORDINATE <br />IN ADVANCE. DUCT SIZES MAY BE REVISED TO FIT TRUSS SYSTEM MAKING CERTAIN THE <br />EQUIVALENT INSIDE CROSS -SECTIONAL AREA IS NOT DECREASED. <br />20. CONTROL WIRING AND CONDUIT SHALL COMPLY WITH NEC AND DIV1SION 26 <br />SPECIFICATIONS. <br />21. CONDENSATE DRAIN LINES SHALL BE INSULATED WITH MINIMUM 1/2" THICK ARMAFLEX <br />OR, EQUIVALENT AND INSTALLED WITH A "P" TRAP AT THE UNIT WITH A MINIMUM <br />TRAP DEPTH OF 2" <br />22. LOCATE WALL AND ROOF TERMINATION'S AT THE SAME RELATIVE ELEVATION AND <br />HORIZONTAL POSITION TO MAINTAIN A UNIFORM APPEARANCE. WHEN IN DOUBT <br />COORDINATE PLACEMENT WITH ARCHITECT. PRIME, COAT, AND PAINT EXTERIOR <br />TERMINATION'S TO MATCH BUILDING EXTERIOR COLOR. <br />23. THE CONTRACTOR SHAM SUBMIT TO THE ARCHITECT A WRITTEN TEST AND BALANCE <br />REPORT OF THE INSTALLED SYSTEM. <br />H.V.A.C, SYMBOLS LEGEND <br />DUCTWORK <br />SUPPLY AIR DUCT - SECTION DIFFUSER CFM <br />TYPE CEILING MOUNTED SUPPLY. IF OTHER <br />1 THAN 4-WAY, ARROWS INDICATE AIR <br />RETURN AIR DUCT - SECTION A-150 ® FLOW PATTERN. <br />EXHAUST AIR DUCT - SECTION <br />SUPPLY DUCT UP THRU ROOF OR 24X12 RECTANGULAR DUCT, FIRST <br />FIGURE IS HORIZONTAL SIDE SHOWN <br />ELBOW TURNED UP <br />92"0 ROUND DUCT, DIAMETER SHOWN <br />XELBOW TURNED DOWN <br />TURNING VANES -J MANUAL VOLUME DAMPER <br />R REFRIGERANT PIPING <br />STANDARD BRANCH TAKEOFF CD CONDENSATE DRAIN <br />OT THERMOSTAT. <br />MANUAL DAMPER ® "HDGI" HYDROGEN GAS DETECTOR. <br />4-WRY DISCHARGE <br />SQUARE SUPPLY AIR DIFFUSER <br />zRETURN AIR REGISTER/GRILLE <br />zEXHAUST AIR REGISTER/GRILLE <br />kSIDEWALL REGISTER OR GRILLE <br />CEILING DIFFUSER WITH FLEXIBLE <br />DUCT SPIN IN FITTING - SIDE DUCT <br />CONNECTION <br />150 CFM 200 CFM 230 CFM <br />TOTAL OUTSIDE AIR = 580 CFM <br />TOTAL EXHAUST AIR = 350 CFM <br />BALANCE = POSITIVE PRESSURE BY 230 CFM <br />1 ;zIlk <br />11y. <br />1 i <br />350 <br />SPLIT SYSTEM AIR CONDITIONING UNIT SCHEDULE� <br />MARK <br />AHU-1/CU-1 <br />AHU-2/CU-2 <br />AHU-3/CU-3 <br />AHU-4/CU-4 <br />TYPE <br />STRAIGHT COOL <br />STRAIGHT COOL <br />STRAIGHT COOL <br />STRAIGHT COOL <br />TOTAL COOLING CAP (MBH ® ARI) <br />29.0 <br />47.0 <br />40.0 <br />23.0 <br />SENSIBLE COOLING CAP. (MBH 0 ARI) <br />20.5 <br />33.0 <br />29.0 <br />17.0 <br />AHU CONFIGURATION <br />VERTICAL <br />VERTICAL <br />VERTICAL <br />VERTICAL <br />SUPPLY AIR (CFM) <br />1000 <br />1650 <br />1520 <br />790 <br />OUTSIDE AIR (CFM) <br />150 <br />200 <br />230 <br />- <br />EXTERNAL STATIC PRESS. (IN.WTR.) <br />0.3 <br />0.3 <br />0.3 <br />0.3 <br />EVAPORATOR FAN <br />HP <br />1/3 <br />3/4 <br />1/2 <br />1/3 <br />VOLT/O <br />240/1 <br />240/1 <br />240/1 <br />240/1 <br />FLA <br />2,4 <br />4.3 <br />2.9 <br />1.7 <br />i <br />ELECTRIC HEAT <br />KW <br />5 <br />8 <br />8 <br />- <br />VOLT/0 <br />240/1 <br />240/1 <br />240/1 <br />- <br />STAGES <br />1 <br />1 <br />1 <br />- <br />COMPRESSORS <br />NUMBER <br />1 <br />1 <br />1 <br />- <br />VOLT/0 <br />240/1 <br />240/1 <br />240/1 <br />240/1 <br />RLA/LRA (EA) <br />15.0/72.5 <br />24.4/140.0 <br />18.6/115.0 <br />9.2/43.0 <br />STAGING (%) <br />0-100 <br />0-100 <br />0-100 <br />0-100 <br />CONDENSER FAN <br />NUMBER <br />1 <br />1 <br />1 <br />1 <br />VOLT/O <br />240/1 <br />240/1 <br />240/1 <br />240/1 <br />MCA <br />19.6 <br />31.9 <br />24.5 <br />13.0 <br />FLA (EA) <br />0.8 <br />1.4 <br />1.1 <br />1.5 <br />AREA SERVED <br />FITNESS RM. <br />CLUB RM. <br />OFFICES/LAUNDRY <br />CABLE ROOM <br />MANUFACTURER AHU/HP <br />CARRIER/PAYNE <br />PAYNE/PAYNE <br />PAYNE/PAYNE <br />PAYNE/PAYNE <br />MODEL# AHU/HP <br />FFIENP030/PA14NA030 <br />PF4MNA061/PA13NA048 <br />PF4MNA061/PA13NA042 <br />PF4MNA024/PA14NA024 <br />MINIMUM EER OR SEER <br />14.0 SEER <br />14.0 SEER <br />14.0 SEER <br />14.0 SEER <br />OPERATING WEIGHT (AHU/CU) <br />125/175 <br />175/250 <br />150/200 <br />125/175 <br />REMARKS <br />1-10 <br />1-10 <br />1-10 <br />1-10 <br />NOTES: <br />1. EXTERNAL STATIC PRESSURE AVAILABLE AFTER COIL FAN CASING, CLEAN FILTER AND ELECTRIC HEATER <br />LOSSES. <br />2. REFRIGERANT LINES AND INSULATION SHALL BE SIZED AND INSTALLED IN STRICT ACCORDANCE WITH <br />MANUFACTURER'S RECOMMENDATIONS. PROVIDE SUBMITTALS ON INSULATION WITH EQUIPMENT SUBMITTALS. <br />3. PROVIDE 1" THROWAWAY FILTERS. <br />4. PROVIDE HEATING/COOLING PROGRAMMABLE THERMOSTAT AND 24 VOLT CONTROL WIRING. THERMOSTAT SHALL HAVE THE <br />SAME NUMBER OF STAGES OF HEATING AND COOLING AS THE UNIT AND DUAL SETPOINT. <br />5. PROVIDE 5 MINUTE TIME DELAY TO PREVENT COMPRESSOR SHORT CYCLING. <br />6. MCA = MINIMUM CIRCUIT AMPACITY <br />7. EXTERIOR INTERLOCK WIRING BETWEEN AHU AND CU MUST BE RUN IN LIQUIDTIfE FLEXIBLE CONDUIT. <br />8. TRANE OR L.ENNOX COMPLYING WITH DESIGN PARAMETERS ARE APPROVED ALTERNATE MANUFACTURERS. <br />9. PROVIDE WITH AHU FACTORY INSTALL CIRCUIT BREAKER. <br />10. INDICATED SEER AMOUNTS ARE PER SCHEDULED CARRIER AHU do CU COMBINATIONS. CONTRACTOR MAY <br />USE APPROVED ALTERNATE MANUFACTURER WITH A MINIMUM OF 14.0 SEER. <br />I <br />EXHAUST <br />FAN SCHEDULE <br />ELECTRICAL <br />PLAN MARK <br />MANUFACTURER/MODEL <br />CFM <br />E.S.P. <br />DRIVE <br />MOUNTING <br />SONES <br />REMARKS <br />VOLT/ <br />AMPS <br />PHASE <br />EF-1 <br />AIR KING/AK150LS <br />150 <br />.125 <br />DIRECT <br />1.70 <br />115/1 <br />CEILING <br />3.3 <br />1-4 <br />EF-2 <br />AIR KING/AK150LS <br />150 <br />.125 <br />DIRECT <br />1.70 <br />115/1 <br />CEILING <br />3.3 <br />1-4 <br />EF-3 <br />AIR KING/AS50 <br />50 <br />.125 <br />DIRECT <br />0.80 <br />115/1 <br />CEILING <br />3.6 <br />1-4 <br />NOTES <br />1. PROVIDE WITH DECORATIVE CEILING <br />GRILLE <br />2. CONTROL WITH ROOM LIGHTS <br />3. PROVIDE WITH BACKDRAFT DAMPER. <br />4. PROVIDE SPEED CONTROL <br />GRILLE AND DIFFUSER SCHEDULE <br />MARK <br />MANUFACTURER/MODEL <br />DESCRIPTION <br />OBD <br />MOUNTING <br />COLOR <br />MATERIAL <br />REMARKS <br />A <br />US AIRE/1100 <br />ADJUSTABLE CURVED BLADE REGISTER <br />Y <br />CEILING <br />WHITE <br />STEEL <br />1,2,3,4,5,6,7 <br />B <br />US AIRE/1400 <br />CUBE CORE RETURN <br />N <br />CEILING <br />ALUM. <br />ALUM <br />1,3,7 <br />1. <br />SEE HVAC PLANS FOR NECK SIZES AND CFMS <br />2. <br />4-WAY UNLESS NOTED OTHERWISE ON PLAN BY ARROWS. <br />3. <br />MAXIMUM PRESSURE DROP OF .04 IN WC. <br />4. <br />TRANSITION ROUND FLEXIBLE OR RECTANGULAR RIGID DUCTWORK TO DIFFUSERS AS REQUIRED. <br />5. <br />HORIZONTAL DIMENSION GIVEN FIRST. <br />6. <br />PROVIDE OBD ADJUSTABLE FROM FACE OF GRILLE ON ALL DIFFUSERS. <br />7. <br />COORDINATE FINAL LOCATION WITH ARCHITECT OR OWNER. <br />•,,,.rEN...� s SGM ENGINEERING INC. <br />>'. No.60 F A C I L I T I ES C 0 N S U L T I N G EN G I N EE RS <br />* * e 935 Lake Baldwin Lane TEL (407) 767-5188 <br />Baldwi( <br />n Park, FAX: 407) 767-5772 <br />STAT F v Orlando, Florida 32814 CA-00006208 <br />As Project number. 2010-090 <br />�e� �� . •• `� www.sgmengineering.com <br />ks ,I 60785 Copyright ©2010 SGM Engineering, Inc. <br />//�lllll <br />3 <br />ro <br />aFORUME <br />n <br />L <br />2 <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />C <br />.y PLANNING I ARCHITECTURE I INTERIOR DESIGN <br />a <br />0 <br />0 745 orienta avenue, suite 1121 <br />altamonte springs, fl 32701 <br />5 phone: 407.830.1400 <br />fax: 407.830.4143 <br />L' AA0002731 <br />t www.forumarchitecture.com <br />Fort King <br />Colony <br />Apartments <br />City of Zephyrhills, FL <br />3 Bid & Permit Set <br />2� SHEET REVISIONS: <br />4 <br />.. <br />EDITED BY: <br />c <br />m <br />r <br />M 18.32 <br />NRP <br />I- - <br />I�II� I i - - - - - - - - - I I 1 11 1 , i lip i r-jTT ❑t r ,n ,t, i,i • 1,7_11ti-fs: r T-T T T- - r-- , -- - -� -- - <br />