Laserfiche WebLink
ARCHITECTURAL <br />REVISIONS <br />BIDDERS PRINTS ISSUED <br />JANUARY 17, 2007 <br />SECTION 02821 <br />CHAIN LINK FENCE AND GATES <br />QUALITY ASSURANCE <br />A. ALL FENCE FABRIC AND POSTS AND GATE FRAMES, FABRIC AND POSTS MATERIALS AND <br />METHODS OF INSTALLATION INCLUDING ALL ERECTION ACCESSORIES, FITTINGS AND <br />FASTENINGS, SHALL BE IN ACCORDANCE WITH THE LATEST EDITIONS OF THE FOLLOWING <br />CHAIN LINK FENCE MANUFACTURER'S INSTITUTE (CLFMI) AND AMERICAN SOCIETY OF <br />TESTING MATERIALS (ASTM) REFERENCES, WHICH ARE HEREBY INCLUDED AND SHALL <br />BECOME A PART OF THESE SPECIFICATIONS. <br />1. ASTM Al 16 - ZINC -COATED (GALVANIZED) STEEL WOVEN WIRE FENCE FABRIC. <br />2. ASTM A123 - ZINC (HOT DIP GALVANIZED) COATING ON IRON AND STEEL PRODUCTS. <br />3. ASTM A153 - ZINC -COATING (HOT -DIP) ON IRON AND STEEL HARDWARE. <br />4. ASTM A392 - ZINC -COATED STEEL CHAIN -LINK FENCE FABRIC. <br />5. ASTM A428 - WEIGHT OF COATING ON ALUMINUM -COATED IRON OR STEEL ARTICLES. <br />6. ASTM A446 - STEEL SHEET, ZINC -COATED (GALVANIZED) BY THE HOT -DIP PROCESS, <br />STRUCTURAL (PHYSICAL) QUALITY. <br />7. ASTM A491 - ALUMINUM -COATED STEEL CHAIN FENCE FABRIC. <br />8. ASTM A569 -STEEL, CARBON (0.15 MAXIMUM PERCENT) , HOT -ROLLED SHEET AND STRIP <br />COMMERCIAL QUALITY. <br />9. ASTM F567 - INSTALLATION OF CHAIN -LINKED FENCE. <br />ASTM F573 - RESIDENTIAL ZINC -COATED STEEL CHAIN -LINK FENCE FABRIC. <br />ASTM F669 - STRENGTH REQUIREMENTS OF METAL POSTS AND RAILS FOR INDUSTRIAL <br />CHAIN -LINK FENCE. <br />10. ASTM F1083 - PIPE, STEEL, HOT -DIPPED ZINC -COATED (GALVANIZED) WELDED, FOR <br />FENCE STRUCTURES. <br />11. ASTM F1234 - PROTECTIVE COATINGS ON STEEL FRAMEWORK FOR FENCES. <br />12. CHAIN -LINK FENCE MANUFACTURERS INSTITUTE (CLFMI) - PRODUCT MANUAL. <br />B. ALL MISCELLANEOUS STEEL ITEMS SHALL CONFORM TO SPECIFIED ASTM STANDARDS <br />C. ALL CONCRETE SHALL BE PREPARED IN ACCORDANCE TO SPECIFICATIONS FOR READY - <br />MIXED CONCRETE ASTM C-94. <br />A. ALL FENCE, FABRIC AND POSTS AND GATE FRAMES, FABRIC AND POSTS MATERIALS, <br />INCLUDING ALL FITTINGS AND ACCESSORIES, SHALL BE IN ACCORDANCE WITH THE <br />FOLLOWING STANDARDS: <br />1. ZINC FABRIC COATING SHALL BE 2,0 OUNCE PER SQUARE FOOT CONFORMING TO ASTM <br />A-392. <br />2. ALUMINUM FABRIC COATING SHALL BE .40 OUNCE PER SQUARE FOOT CONFORMING TO <br />ASTM A-491, <br />3. ROLL FORMED STEEL SECTIONS SHALL CONFORM TO ASTM A-570, GRADE 45 WITH 2.0 <br />OUNCE PER SQUARE FOOT ZINC -ALUMINUM COATING CONFORMING TO ASTM A-525 OR 2.0 <br />OUNCE PER SQUARE FOOT ZINC COATING CONFORMING TO ASTM A-132. <br />4. TYPE I STEEL PIPE SHALL BE STANDARD WEIGHT, SCHEDULE 40, WITH 2.0 OUNCE PER <br />SQUARE FOOT ZINC COATING CONFORMING TO ASTM A-123. <br />5, TYPE II STEEL PIPE SHALL BE COLD ROLLED WELDED STEEL CONFORMING TO ASTM <br />A-569 AND HAVING A MINIMUM YIELD STRENGTH OF 50,000 PSI. COATING SHALL BE <br />CORROSION RESISTANT ZINC BASED CONTAINING 80% MINIMUM ZINC POWDER. <br />6. ALL FITTINGS SHALL BE HOT DIPPED GALVANIZED CONFORMING TO ASTM A-153. <br />7. BENDING STRENGTHS UNDER A SIX FOOT (6') CANTILEVER LOAD FOR POSTS AND A <br />VERTICAL BENDING STRENGTH ON A TEN FOOT (10') SPAN FOR RAILS SHALL NOT BE LESS <br />THAN SPECIFIED BELOW: <br />a. CORNER AND TERMINAL POST BENDING STRENGTH SHALL BE 381 POUNDS MINIMUM. <br />b. INTERMEDIATE POST BENDING STRENGTH SHALL BE 201 POUNDS MINIMUM. <br />c. TOP RAIL BENDING STRENGTH SHALL BE 202 POUNDS MINIMUM. <br />B. FENCE FABRIC SHALL BE #9 GAUGE, CHAIN LINK OPEN HEARTH STEEL WIRE, HOT -DIPPED <br />GALVANIZED AFTER WEAVING OR HOT -DIPPED ALUMINUM COATED BEFORE WEAVING, <br />WOVEN IN A 2" DIAMOND MESH. TOP SALVAGE SHALL BE KNUCKLED AND BOTTOM SALVAGE <br />SHALL BE TWISTED AND BARBED. <br />1. PRIVACY SLATS SHALL BE PLASTIC STRIPS, COLOR TO BE MANUFACTURES STANDARD <br />"BIEGE". SLATS SHALL BE COMPRISED OF STRIPS SIZED TO FIT FABRIC WEAVE AND <br />EXTENDED IN ONE (1) PIECE FROM TOP TO BOTTOM OF FABRIC. <br />C. POSTS SHALL BE 3.5" X 3.5" ROLL FORMED STEEL SECTION, WEIGHT 4.8 LBS. PER FOOT, 3" <br />O.D., TYPE I STEEL PIPE, WEIGHT 5.79 LBS. PER FOOT OR 3" O.D. OR TYPE II STEEL PIPE, <br />WEIGHT 4.64 LBS. PER FOOT. <br />D. TOP, INTERMEDIATE AND BOTTOM RAILS SHALL BE ROLLED FORMED STEEL SECTION, <br />WEIGHT 1.37 LBS. PER FOOT, 1-5/8" O.D., TYPE I STEEL PIPE, WEIGHT 2.27 LBS. PER FOOT OR <br />1-5/8" O.D., TYPE II STEEL PIPE, WEIGHT 1.84 LBS. PER FOOT. <br />1, BOTTOM RAILS SHALL BE PROVIDED FOR THE FIRST FENCE BAY ADJACENT TO CORNER <br />POSTS (IN EACH DIRECTION) AND AT TERMINAL AND GATE POSTS. <br />E. GATE POSTS SHALL BE 3.5" X 3.5" ROLL FORMED STEEL SECTION, WEIGHT 4.8 POUNDS PER <br />FOOT, 3" O.D., TYPE I STEEL PIPE, WEIGHT 5.79 POUNDS PER FOOT OR 3" O.D., TYPE II STEEL <br />PIPE, WEIGHT 4.64 POUNDS PER FOOT. TENSION WIRE AT ALL OTHER LOCATIONS. <br />F. BOTTOM TENSION WIRE SHALL BE NO. 6 GAUGE GALVANIZED OR ALUMINUM COATED <br />SPRING COIL OR CRIMPED WIRE. MINIMUM WEIGHT OF COATING SHALL BE THE SAME AS <br />THE WIRE FABRIC. <br />G. POST TOPS SHALL BE PRESSED STEEL OR MALLEABLE IRON DESIGNED AS A <br />WEATHERTIGHT CLOSURE CAP. TOPS OF LINE POSTS SHALL BE DESIGNED TO PERMIT <br />PASSAGE OF TOP RAIL. PROVIDE ONE CAP FOR EACH POST. <br />H. STRETCHER BARS SHALL BE ONE PIECE LENGTHS EQUAL TO FULL HEIGHT OF FABRIC <br />WITH A MINIMUM CROSS SECTION OF 3/16" X 3/4". PROVIDE ONE STRETCHER BAR FOR EACH <br />TERMINAL POST AND FOR EACH CORNER POST. <br />I. STRETCHER BAR BANDS, TIE WIRES, HOG RINGS, COUPLINGS, NUTS, BOLTS AND <br />MISCELLANEOUS FASTENING DEVICES SHALL BE MANUFACTURER'S STANDARD FOR HEAVY <br />CONSTRUCTION FENCE AND GATE. <br />J. SWING GATE SHALL BE FABRICATED FROM THE FOLLOWING COMPONENTS: <br />1. FABRIC SHALL BE IDENTICAL TO FENCE FABRIC. <br />2. GATE FRAME SHALL BE 2" O.D., TYPE I STEEL PIPE, WEIGHT 2.72 POUNDS PER FOOT OR 2" <br />O.D., TYPE II STEEL PIPE WEIGHT 2.28 POUNDS PER FOOT. <br />3. HINGES SHALL BE PRESSED STEEL OR MALLEABLE IRON TO SUIT GATE SIZE, NON -LIFT <br />OFF TYPE. HINGES SHALL BE OFFSET TO PERMIT 180 DEGREE OPENING. PROVIDE ONE AND <br />ONE-HALF (1-1/2) PAIR OF HINGES PER LEAF. <br />4. LATCH SHALL BE FORKED TYPE FOR SINGLE GATE AND PLUNGER BAR TYPE WITH FLUSH <br />KEEPER FOR DOUBLE GATE, LATCH SHALL PERMIT OPERATION FROM EITHER SIDE WITH <br />PROVISIONS FOR PADLOCK. <br />5. GATE KEEPER SHALL BE AUTOMATIC TYPE FOR SECURING FREE END OF EACH GATE <br />LEAF IN ITS FULL OPEN POSITION. <br />K. ALL COMPONENTS AND FABRICS SHALL HAVE THE FINISH AND COLOR AS SHOWN ON THE <br />DRAWINGS OR AS SPECIFIED HEREIN. <br />1, ALL HARDWARE AND ACCESSORIES SHALL HAVE THE SAME FINISH AND COLOR AS THE <br />MAIN COMPONENT AND FABRICS. <br />L. COATING FOR WELDS SHALL BE LIQUID ZINC BASED COATING, CONTAINING 80% MINIMUM <br />ZINC POWDER, SPECIFICALLY FORMULATED FOR GALVANIZE TOUCH-UP. <br />M. CONCRETE FOR POST BASES SHALL CONTAIN PORTLAND CEMENT COMPLYING WITH <br />ASTM C-150, FINE AND COARSE AGGREGATES COMPLYING WITH ASTM C-33, AND CLEAN <br />WATER. PROPORTION AND MIX MATERIALS TO PROVIDE CONCRETE WITH A MINIMUM 28-DAY <br />COMPRESSIVE STRENGTH OF 2500 PSI, USING AT LEAST 4 SACKS OF CEMENT PER CUBIC <br />YARD AND 1" MAXIMUM SIZE AGGREGATE. <br />1. PROVIDE AIR -ENTRAINING ADMIXTURE COMPLYING WITH ASTM C-260 TO CREATE 2%TO <br />4%AIR ENTRAINMENT. <br />2. CONCRETE TO HAVE A MAXIMUM SLUMP OF 3' <br />. <br />3. ALL MIX DESIGN, MATERIALS AND ADMIXTURES MUST MEET THE REQUIREMENTS OF <br />SECTION 03300. <br />EXECUTION <br />INSTALLATION <br />A. ALL INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH THE REQUIREMENTS OF THE <br />CHAIN LINK FENCE MANUFACTURERS INSTITUTE (CLFMI) AND "INSTALLATION OF CHAIN LINK <br />FENCING" ASTM F567.PIECE <br />B. FENCE POSTS SHALL BE SPACED 6-0" MAXIMUM UNLESS OTHERWISE INDICATED ON THE <br />DRAWINGS. <br />1. EXCAVATE HOLES FOR POST BASES IN FIRM UNDISTURBED OR COMPACTED SOIL. <br />HOLES SHALL BE A MINIMUM OF 10" DIAMETER FOR LINE POSTS AND 12" DIAMETER FOR <br />CORNER, GATE AND TERMINAL POSTS. EXCAVATE HOLE DEPTHS APPROXIMATELY 3" LOWER <br />THAN POST BOTTOM, WITH BOTTOM OF POSTS SET NOT LESS THAN 3'-0" BELOW SURFACE <br />WHEN IN FIRM, UNDISTURBED SOIL (OR SET LOWER TO EXCEED LOCAL FROST DEPTHS), <br />EXCAVATE DEEPER AS REQUIRED FOR ADEQUATE SUPPORT IN SOFT AND LOOSE SOILS. <br />2. PLACE CONCRETE AROUND POSTS IN A CONTINUOUS POUR, ROD AND TAMP FOR <br />CONSOLIDATION. PLACE CONCRETE TO LEVEL OF ADJACENT GRADES, FINISH WITH A WASH <br />TO POST. CHECK EACH POST FOR ELEVATION, VERTICAL AND TOP ALIGNMENT AND HOLD <br />POSITION DURING CONCRETE PLACEMENT AND FINISHING OPERATIONS. CONCRETE SHALL <br />CURE A MINIMUM OF THREE (3) DAYS PRIOR TO INSTALLING FABRIC. DO NOT STRETCH <br />FABRIC UNTIL CONCRETE HAS CURED. <br />3. PROVIDE TEMPORARY BRACING OR GUYS TO MAINTAIN POSTS IN A PLUMB POSITION <br />UNTIL CONCRETE HAS CURED. <br />C. RAILS ARE TO BE SECURELY FASTENED TO LINE, GATE, TERMINAL AND CORNER POSTS. <br />TOP RAILS SHALL EXTEND THROUGH POST TOPS AND SHALL BE A MINIMUM OF EIGHTEEN <br />FEET (18') IN LENGTH AND SHALL BE FITTED WITH COUPLINGS TO FORM CONTINUOUS <br />LENGTHS. COUPLINGS SHALL BE FORMED TO CONFIGURATION OF RAIL AND BE SIX INCHES <br />(6") MINIMUM IN LENGTH, <br />1. BOTTOM RAILS ARE TO BE PROVIDED FOR THE FIRST FENCE BAY ADJACENT TO CORNER <br />POSTS (IN EACH DIRECTION) AND AT TERMINAL AND GATE POSTS. <br />D. THE CHAIN LINK FENCE FABRIC SHALL BE SECURELY FASTENED TO ALL CORNER, GATE <br />AND TERMINAL POSTS USING STRETCHER BARS AND HEAVY GAUGE STRETCHER BAR BANDS. <br />THERE SHALL BE (1) BAND FOR EACH FOOT IN THE HEIGHT OF FENCE. THE FABRIC SHALL <br />BE FASTENED TO ALL INTERMEDIATE LINE POSTS WITH 9 GAUGE MINIMUM TIE WIRES, <br />SPACING NOT TO EXCEED FIFTEEN INCHES (15"). FABRIC SHALL BE TIED TO RAILS AND <br />BOTTOM TENSION WIRE WITH 9 GAUGE MINIMUM TIE WIRES, SPACING NOT TO EXCEED <br />TWENTY-FOUR INCHES (24"). <br />1. PROVIDE APPROXIMATELY 2" CLEARANCE BETWEEN FINISH GRADE AND BOTTOM <br />SALVAGE. <br />2. STRETCH FABRIC BETWEEN TERMINAL AND/OR GATE POSTS, OR AT INTERVALS NOT TO <br />EXCEED 100 FEET, WHICHEVER IS LESS. <br />E. BOTTOM TENSION WIRE SHALL BE SECURED TO ALL INTERMEDIATE LINE POSTS WITH 9 <br />GAUGE MINIMUM TIE WIRES. <br />1. PROVIDE APPROXIMATELY 2" CLEARANCE BETWEEN TENSION WIRE AND FINISH GRADE. <br />2. PLACE TENSION WIRE ON THE OUTSIDE OF POSTS. <br />3. STRETCH TENSION WIRE BETWEEN TERMINAL POSTS, OR AT INTERVALS NOT TO EXCEED <br />10Y, WHICHEVER IS LESS. <br />F. FABRICATE GATE FRAMES OF PIPE MEMBERS, AS SPECIFIED. PROVIDE ADDITIONAL <br />HORIZONTAL MEMBERS AND TRUSS RODS TO RESIST SAG AND TWIST, ENSURE PROPER <br />GATE OPERATION AND FOR ATTACHMENT OF FABRIC, HARDWARE AND ACCESSORIES. <br />1. ASSEMBLE GATE FRAMES BY WELDING OR BY FITTINGS AND RIVETS FOR RIGID <br />CONNECTIONS, ALL WELDS SHALL BE COATED WITH LIQUID ZINC. PROVIDE 3/8" MINIMUM <br />DIAMETER ADJUSTABLE TRUSS RODS ON ALL GATE FRAMES WITH RIVETED FITTING <br />CONNECTIONS. <br />2. INSTALL FABRIC WITH STRETCHER BARS AT VERTICAL EDGES, AND TIE WIRES AT TOP AND <br />BOTTOM EDGES. ATTACH STRETCHER BARS TO GATE FRAME AT NOT MORE THAN 15" O.C. <br />ATTACH HARDWARE WITH RIVETS OR BY OTHER MEANS, WHICH WILL PROVIDE SECURITY <br />AGAINST REMOVAL OR BREAKAGE. <br />3. INSTALL GATES PLUMB, LEVEL AND SECURE, PROVIDE FULL OPENING WITHOUT <br />INTERFERENCE. PROVIDE ONE (1) GATE KEEPER FOR EACH LEAF. <br />TOLERANCES <br />A. SITE FENCING, POSTS AND GATES SHALL BE INSTALLED TO EXTENT, LINES AND LOCATIONS <br />SHOWN ON THE DRAWINGS. NO FENCE COMPONENT SHALL EXTEND ACROSS PROPERTY LINE. <br />1. VARIATION IN PLUMB SHALL NOT EXCEED 1/4" IN 6-0". <br />2. MAXIMUM OFFSET FROM TRUE POSITION SHALL NOT EXCEED 1" IN 25'-0". <br />3. NO FENCE COMPONENT MAY EXTEND OVER PROPERTY LINE. <br />SECTION 03300 <br />CAST -IN -PLACE CONCRETE <br />QUALITY ASSURANCE <br />A. ALL CONCRETE MATERIALS SHALL CONFORM TO CURRENT SPECIFIED ASTM <br />AND ACI STANDARDS AND SPECIFICATIONS. <br />PRODUCTS <br />MATERIALS <br />A. CEMENT SHALL BE GREY PORTLAND CEMENT, TYPE 1, OR 1A, CONFORMING TO ASTM <br />C 150, OR OTHER TYPES IF REQUIRED BY THE SOILS ENGINEER. USE SAME BRAND FOR ALL <br />EXPOSED WORK. <br />B. WATER SHALL BE POTABLE, CLEAN AND FREE FROM IMPURITIES AFFECTING THE <br />STRENGTH OF THE CONCRETE, IN ACCORDANCE WITH ACI AND ASTM REQUIREMENTS, <br />C. CONCRETE AGGREGATES SHALL CONFORM TO ASTM C-33. <br />1. FINE AND COARSE AGGREGATES SHALL BE REGARDED AS SEPARATE INGREDIENTS AND <br />EACH SHALL CONFORM TO THE APPROPRIATE GRADING REQUIREMENTS OF ASTM C-33. <br />ADMIXTURES <br />A. AIR -ENTRAINING ADMIXTURES SHALL CONFORM TO ASTM C-260. <br />1. PRODUCT/MANUFACTURER; ONE OF THE FOLLOWING: <br />A. "AIR -MIX'; EUCLID CHEMICAL CO. <br />B. "SIKA-AER"; SIKA CORP. <br />C. "MB-VR OR MB-AE"; MASTER BUILDERS. <br />D. "AIR-TITE", CORMIX CONSTRUCTION CHEMICALS. <br />B. CHEMICAL ADMIXTURES CONFORMING TO ASTM C-494 USED TO RETARD OR ACCELERATE <br />SETTING, REDUCE WATER RATIO OR PREVENT FREEZING SHALL NOT BE USED WITHOUT <br />PRIOR APPROVAL FROM KMART CORPORATION. NO ADMIXTURES CONTAINING CALCIUM <br />CHLORIDE MAY BE USED. <br />C. FLY ASH SHALL BE A CALCINATED POZZOLAN AND SHALL CONFORM TO ASTM C-618, <br />CLASS C OR-F. <br />1. FLY ASH MAY BE USED TO REPLACE 25% PORTLAND CEMENT BY WEIGHT MAXIMUM. <br />ACCESSORIES <br />A. NON -SHRINK GROUT SHALL BE PREMIXED, NON-METALLIC, NON -STAINING TYPE, <br />1. PRODUCT/MANUFACTURER; ONE OF THE FOLLOWING: <br />A. "SET GROUT"; MASTER BUILDERS <br />B. "EUCO-NC"; EUCLID CHEMICAL CO. <br />C. 10K"; SONNEBORN-REXNORD. <br />D. "SURE -GRIP" OR "UTILITY GROUT"; DAYTON SUPERIOR <br />CORPORATION <br />B. PREFORMED EXPANSION JOINTS SHALL BE 1/2" THICK ASPHALT IMPREGNATED CANE <br />FIBER EXPANSION JOINTS, CONFORMING TO ASTM D-1751. <br />C. BOND BREAKER SHALL BE NO. 15 ASPHALT SATURATED PLAIN ORGANIC FELT <br />CONFORMING TO ASTM D-226, <br />D. EXPANSION JOINT SEALANT SHALL BE TRAFFIC GRADE, SELF LEVELING. COLOR SHALL BE <br />BLACK. <br />1. PRODUCT/MANUFACTURER; ONE OF THE FOLLOWING: <br />A. ATHC-900"; TREMCO <br />B. ANR-200; PECORA CORPORATION <br />2. PRIMER SHALL BE AS RECOMMENDED BY SEALANT MANUFACTURER. <br />CONCRETE MIX <br />A. MIX CONCRETE IN ACCORDANCE WITH ACI 304. DELIVER CONCRETE IN ACCORDANCE <br />WITH ADTM C-94. <br />B. ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE CONSISTING OF A PROPORTIONED <br />MIXTURE OF PORTLAND CEMENT, FINE AND COARSE AGGREGATE AND WATER. <br />1. CONCRETE PROPORTIONS SHALL BE SELECTED ON THE BASIS OF TRIAL MIXES <br />CONFORMING TO AC1 211.1. <br />2. CONCRETE SHALL BE SO PROPORTIONED TO PROVIDE A WATER/CEMENT RATIO BETWEEN <br />0.45 AND 0.50. IN NO CASE SHALL THE WATER/CEMENT RATIO EXCEED 0.50. <br />C. ALL CONCRETE UNLESS OTHERWISE NOTED, SHALL HAVE A MINIMUM COMPRESSIVE <br />STRENGTH OF 3,000 PSI AT 28 DAYS, MIX DESIGN SHALL BE SO PROPORTIONED TO CONTAIN <br />A MINIMUM OF 517 POUNDS OF CEMENT PER CUBIC YARD. <br />1. 1500 PSI CONCRETE MAY BE USED FOR FILL. MIX DESIGN SHALL BE SO PROPORTIONED <br />TO CONTAIN A MINIMUM OF 376 POUNDS OF CEMENT PER CUBIC YARD. <br />2. FLY ASH CONFORMING TO ASTM C-618 MAY BE SUBSTITUTED FOR UP TO 25% BY WEIGHT <br />OF PORTLAND CEMENT. <br />3. 2,500 PSI CONCRETE MAYBE USED FOR GUARD POST BASES. MIX DESIGN SHALL BE SO <br />PROPORTIONED TO CONTAIN A <br />MINIMUM OF 458 POUNDS OF CEMENT PER CUBIC YARD. <br />D. ALL CONCRETE UNLESS OTHERWISE NOTED, SHALL BE PROPORTIONED TO HAVE A <br />SLUMP OF 2-1/2" TO 4" MAXIMUM, TOLERANCE IN SLUMP SHALL NOT EXCEED ACI <br />RECOMMENDATIONS. <br />1. SLUMP FOR CONCRETE FILL MAY BE 6" MAXIMUM. <br />E. ALL EXTERIOR CONCRETE, BUILDING FOUNDATIONS, PIERS AND FOUNDATION WALLS <br />SHALL BE AIR -ENTRAINED, AIR CONTENT SHALL BE 6%+1%. <br />1. INTERIOR SLABS SHALL NOT BE AIR ENTRAINED. <br />F. CHEMICAL ADMIXTURES USED TO RETARD OR ACCELERATE SETTING, REDUCE <br />WATER/CEMENT RATIO OR PREVENT FREEZING SHALL NOT BE USED WITHOUT PRIOR <br />APPROVAL OF THE KMART CORPORATION. <br />G. NO ADMIXTURE CONTAINING CALCIUM CHLORIDE MAY BE USED. <br />H. MAXIMUM AGGREGATE SIZE SHALL CONFORM TO THE FOLLOWING AND SHALL NOT <br />EXCEED TOLERANCES ON OVERSIZE AS PER ASTM C-33. <br />1. FOOTINGS, FOUNDATIONS AND WALLS 3/4" TO 1-1/2" <br />2. SLABS ON GROUND 3/4" - V <br />3. CONCRETE FILL 2" <br />PRODUCTION <br />A. READY -MIXED CONCRETE PRODUCTION SHALL CONFORM TO ASTM C-94 AND THE <br />NATIONAL READY MIX CONCRETE ASSOCIATION. USE OF NON -AGITATING TRUCKS IS NOT <br />PERMITTED. <br />B. USE OF RE -TEMPERED CONCRETE IS NOT PERMITTED <br />C. THE ADDITION OF WATER AT THE JOB SITE IS PERMITTED PROVIDING THAT ONLY <br />SUFFICIENT WATER IS ADDED TO PROVIDE A WORKABLE MIX AND THAT THE DESIGN WATER <br />CEMENT RATIO AND/OR THE MAXIMUM SLUMP ARE NOT EXCEEDED. THE ADDITION OF <br />PORTLAND CEMENT OR FLY ASH AT JOB SITE TO MAINTAIN WATER CEMENT RATIO IS NOT <br />PERMITTED. <br />D. IF AIR -ENTRAINED PORTLAND CEMENT IS NOT USED, AIR -ENTRAINING ADMIXTURES SHALL <br />BE INTRODUCED INTO THE CONCRETE, IN ACCORDANCE WITH MANUFACTURERS <br />RECOMMENDATIONS, <br />E. WHEN POURING CONCRETE AGAINST PREVIOUSLY POURED WORK, THE EXISTING <br />SURFACES SHALL BE THOROUGHLY CLEANED AND ROUGHENED, THEN WETTED AND <br />COATED WITH A THICK CEMENT AND WATER GROUT OR BONDING AGENT, NOT MORE THAN <br />FIFTEEN MINUTES IN ADVANCE OF THE NEW CONCRETE. CORE EXISTING CONCRETE AND <br />INSERT DOWELS WHERE REQUIRED ON THE DRAWINGS. <br />INSTALLATION <br />A. PLACEMENT - GENERAL <br />1. DELIVER AND PLACE CONCRETE IN ACCORDANCE WITH ACI-304 AND ASTM C-94. <br />2. UTILIZE COLD WEATHER AND/OR HOT WEATHER INSTALLATION PROCEDURES AND <br />PROTECTION AS RECOMMENDED IN ACI 306R AND ACI 305R. <br />B. PLACEMENT - FLOOR SLABS <br />1. CONCRETE FLOOR SLABS ON GRADE SHALL NOT BE POURED UNTIL ALL UNDERFLOOR <br />CONSTRUCTION, INCLUDING MECHANICAL AND ELECTRICAL LINES ARE INSTALLED <br />COMPLETE, BACKFILLED, INSPECTED AND APPROVED BY THE KMART PROJECT MANAGER. <br />A. FLOOR SLABS SHALL BE POURED ON 4" MINIMUM OF COMPACTED POROUS FILL. SEE <br />SECTION 02315. <br />B. INSTALL VAPOR BARRIER OVER A SMOOTH COMPACTED 4" MINIMUM POROUS FILL BASE. <br />VAPOR BARRIER SHALL BE LAPPED A MINIMUM OF 6" WITH LAP 1N DIRECTION OF CONCRETE <br />POUR. USE MAXIMUM SHEET SIZE WITH A MINIMUM OF JOINTS, CARE SHALL BE EXERCISED <br />TO PREVENT PUNCTURE, DAMAGE OR RUPTURE OF VAPOR BARRIER, WHERE COLUMNS, <br />PIPE, CONDUIT ETC. PENETRATE VAPOR BARRIER, CUT AROUND PROJECTION AND SEAL <br />WITH JOINT TAPE. <br />C. ALL CONTROL JOINTS SHALL BE CUT INTO THE CONCRETE SLAB USING AN EARLY -CUT <br />SAW, SUCH AS SOFF-CUTT" OR EQUAL. PLASTIC "ZIP -STRIP" OR OTHER PREFORMED <br />CONTROL JOINTS ARE NOT PERMITTED. <br />1. ALIGNMENT OF CONTROL JOINTS MUST BE STRAIGHT. <br />2. SAW CUTTING MUST BE DONE AS SOON AS THE CONCRETE IS SET ENOUGH THAT THE <br />CUTTING OPERATION DOES NOT DISTURB THE SURFACE MATRIX OF THE CONCRETE. <br />3. ALL SAW CUT JOINTS WITHIN THE SALES FLOOR SLAB TO BE COVERED WITH VINYL TILE <br />SHALL NOT BE FILLED. <br />4. ALL SAW CUT JOINTS IN THE REAR STOCK AREA AND ELSEWHERE INSIDE THE BUILDING <br />WHERE VINYL TILE IS NOT APPLIED SHALL BE FILLED WITH A SEMI -RIGID EPDXY FILLER. <br />5. ALL SAW CUT JOINTS IN THE EXTERIOR GARDEN SHOP SLAB SHALL BE FILLED WITH A SELF <br />LEVELING SILICONE POLYMER SEALANT. <br />6. SAW CUTS SHALL BE 1/8" WIDE X 1" DEEP. <br />7. FURNISH AND INSTALL NO. 15 FELT BOND BREAKER FULL DEPTH OF SLAB WHERE SLABS <br />ABUT VERTICAL SURFACE, PERIMETER OF STEEL COLUMNS AND ELSEWHERE AS INDICATED <br />ON THE DRAWINGS. <br />8. SHAPE SLABS TO THE SLOPES AND ELEVATIONS INDICATED, AND ACCURATELY PITCH OR <br />GRADE TO THE DRAINAGE FITTINGS, EQUIPMENT AND FIXTURES OCCURRING THEREIN. <br />9. DEPRESS AND FORM SLABS FOR FLOOR DRAINS, SCRUBBER DRAIN AND CURB, <br />ELECTRICAL EQUIPMENT PADS, AND ELSEWHERE AS INDICATED ON THE DRAWINGS. <br />A. THICKEN SLAB UNDER VESTIBULE BULKHEAD AND ALL LOAD BEARING STUD PARTITIONS <br />AND ELSEWHERE AS INDICATED ON THE DRAWINGS. <br />B. NO HORIZONTAL RUNS OF PIPING OR ELECTRICAL CONDUIT WILL BE PERMITTED IN <br />CONCRETE FLOOR SLABS. <br />E. PLACEMENT EXTERIOR CONCRETE <br />1. EXTERIOR SIDEWALKS, SLABS, APRONS, CURBS, COMBINATION CURB AND GUTTER, PADS, <br />RAMPS, APPROACHES, ETC., CONNECTED TO OR ABUTTING BUILDINGS SHALL BE POURED <br />TO SLOPES, ELEVATIONS AND PROFILES INDICATED ON DRAWINGS AND ACCURATELY <br />PITCHED TO DRAINAGE FITTINGS OCCURRING THEREIN. <br />2. FURNISH AND INSTALL EXPANSION JOINTS WHERE EXTERIOR SLABS, PAVEMENTS, <br />SIDEWALKS, ETC., ABUT VERTICAL SURFACES AND FIFTY FEET (50') MAXIMUM ON CENTER <br />UNLESS OTHERWISE INDICATED. JOINTS SHALL BE EQUALLY SPACED IN A REGULAR <br />PATTERN ALONG SIDEWALK OR WITHIN ANY GIVEN SLAB AREA. JOINTS IN CURB SHALL <br />ALIGN WITH SIDEWALK AND SLAB JOINTS. <br />A. EXPANSION JOINTS SHALL BE 1/2" THICK, FULL DEPTH OF SLAB. SET FILLER <br />APPROXIMATELY 1" BELOW FINISHED SURFACE AND FILL WITH NON -TRACKING RUBBER OR <br />ELASTOMERIC SEALANT. <br />3 CONTROL 1 1 4 TOOLED OR FORMED. SAW CUT JOINTS WILL BE <br />JOINTS SHALL BE / S - / <br />PERMITTED. DEPTH OF JOINTS SHALL BE 1/5 TO 1/4 OF SLAB THICKNESS. <br />A. CONTROL JOINTS IN SIDEWALKS SHALL BE SPACED AS INDICATED ON DRAWINGS. <br />UNBROKEN CONCRETE AREA SHALL NOT BE LESS THAN 16 SQUARE FEET AND NO MORE <br />THAN 36 SQUARE FEET. <br />B. CONTROL JOINTS IN OPEN GARDEN SHOP AREA SHALL BE EVENLY SPACED BUT NO MORE <br />THAN 20 FEET ON CENTER IN EITHER DIRECTION, OR AS INDICATED ON DRAWINGS. <br />C. SAW CUT JOINTS SHALL BE FILLED WITH A SELF -LEVELING SILICONE POLYMER SEALANT, <br />4. ALL EXPOSED EDGES OF EXPANSION AND CONTROL JOINTS, ETC., SHALL BE ROUNDED <br />WITH A 1/4" RADIUS -EDGING TOOL. <br />A. SAW CUT CONTROL JOINTS SHALL BE FILLED WITH A SILICONE POLYMER SEALANT. <br />CONCRETE FINISHES <br />A. "DEFINITION" OF FINISH TYPES SHALL BE AS DEFINED IN SPECIFICATIONS FOR <br />STRUCTURAL CONCRETE FOR BUILDINGS ACI 301. <br />B. ALL FLOORS SLABS SHALL BE FINISHED AS FOLLOWS: <br />1. EXTERIOR SLABS, SIDEWALKS, CURBS, RAMPS, AND PADS SHALL HAVE A "BROOM OR BELT <br />FINISH". <br />2. EXTERIOR GARDEN SHOP AREA CONCRETE SLAB SHALL HAVE A "BROOM FINISH". <br />CURING AND PROTECTION <br />A. IMMEDIATELY AFTER PLACEMENT PROTECT NEW INTERIOR AND EXTERIOR CONCRETE <br />FROM MOISTURE LOSS AND PREMATURE DRYING, EXCESSIVE HOT AND COLD <br />TEMPERATURES AND OTHER ADVERSE ENVIRONMENTAL CONDITIONS FOR A MINIMUM OF 7 <br />DAYS, FOLLOW APPLICABLE PROVISIONS OF ACI 301. <br />1. APPLY LIQUID CURING COMPOUND IN ACCORDANCE WITH MANUFACTURER <br />RECOMMENDATIONS. <br />2. PROTECT CONCRETE FROM DAMAGE, MECHANICAL INJURY, LOAD STRESSES AND <br />ELEMENTS DURING CURING PROCESS. <br />B. IMMEDIATELY PRIOR TO FINAL ACCEPTANCE APPLY 1 COAT OF <br />SEALER ON ALL INTERIOR EXPOSED CONCRETE FLOORS. <br />1. DO NOT APPLY SEALER TO ANY CONCRETE FLOOR TO RECEIVE FLOOR COVERING. <br />2. CONCRETE SEALER MUST BE COMPATIBLE WITH CONCRETE CURING COMPOUND. <br />TOLERANCES <br />A. ALL CONCRETE FOUNDATIONS, WALLS, SLABS, APRONS, EXTERIOR CONCRETE, ETC. <br />SHALL BE PLACED AND FINISHED AS REQUIRED TO MEET THE CONSTRUCTION TOLERANCE <br />REQUIREMENTS OF ACI-304. <br />REPAIRING, PATCHING, GRINDING <br />A. PATCH CRACKS, ROCK POCKETS, HONEYCOMBS, AND HOLES RESULTING FROM THE <br />REMOVAL OF THE NAIL, ROD AND CONE TIES, SEPARATORS, AND CORE SAMPLES. CHIP <br />AWAY DEFECTIVE AREAS TO SOLID CONCRETE, FORMING PERPENDICULAR EDGES OR <br />SLIGHTLY UNDERCUT EDGES. DRENCH AREA OF PATCH AND SURROUNDING AREA WITH <br />WATER. BRUSH A THIN COAT OF CEMENT GROUT ONTO THE BASE AND EDGES OF THE <br />PATCH AREA. <br />1. EXPOSED CONCRETE COLUMNS SHALL BE PATCHED, RUBBED AND SANDED AS REQUIRED <br />TO PROVIDE A UNIFORM FINISH THROUGHOUT EACH COLUMN AND FROM COLUMN TO <br />COLUMN. <br />B. CONCRETE FLOORS HAVING DEFECTS OF SUFFICIENT MAGNITUDE TO "READ THROUGH" <br />FLOOR COVERING SHALL BE REMEDIED BY GRINDING, FILLING WITH AN ACCEPTABLE <br />UNDERLAYMENT MATERIAL, OR BY TOTAL REMOVAL AND REPLACEMENT OF SLAB. <br />1. UNDERLAYMENT PRODUCT/MANUFACTURER, ONE OF THE FOLLOWING: <br />A. "ARDEX K15", ARDEX, INC. <br />B. "FLO-TOP", EUCLID CHEMICAL COMPANY <br />C. "LEVELAYER 1",DAYTON SUPERIOR CORPORATION <br />D. "TECK 2800", GEISTLICH INTERNATIONAL <br />INC. <br />2. LATEX UNDERLAYMENT MATERIAL MAY NOT BE USED. <br />3. INSTALLATION SHALL BE CERTIFIED AND/OR AS RECOMMENDED BY THE MANUFACTURER. <br />SECTION 06100 <br />ROUGH CARPENTRY <br />GENERAL <br />DESCRIPTION: <br />FURNISH ALL MATERIALS, LABOR, EQUIPMENT, SERVICE, SCAFFOLDING, ETC. NECESSARY <br />AND INCIDENTAL FOR THE COMPLETION OF ALL ROUGH CARPENTRY AS INDICATED ON THE <br />DRAWINGS AND AS SPECIFIED HEREIN. <br />QUALITY ASSURANCE <br />A. ALL LUMBER SHALL CONFORM TO AND BE GRADED IN CONFORMANCE WITH THE <br />AMERICAN LUMBER STANDARD PS-20. <br />B. ALL PLYWOOD SHALL BE IDENTIFIED WITH THE APPROPRIATE GRADE -TRADEMARK OF <br />AMERICAN PLYWOOD ASSOCIATION AND MEET THE REQUIREMENTS OF U.S. PRODUCT <br />STANDARD PS-L. <br />PRODUCTS <br />MATERIALS: <br />DIMENSION AND BOARD LUMBER SHALL BE DOUGLAS FIR, ALL LUMBER SHALL BE "SEASONED <br />DRY" (S-DRY), 19% OR LESS MOISTURE CONTENT. EXTREME FIBER STRESS IN BENDING SHALL <br />BE 1250 P.S.I. (FB) REPETITIVE (MINIMUM). <br />A. LUMBER GRADES SHALL BE AS FOLLOWS: <br />1. LIGHT FRAMING AND STUDS (2" TO 4" THICK, 2" TO 4" WIDE) SHALL BE DOUGLAS FIR, S4S, <br />CONSTRUCTION OR BETTER. <br />B. PLYWOOD GRADES SHALL BE AS FOLLOWS: <br />1. PLYWOOD WALLS (UNFINISHED AREAS) SHALL BE B-D INT-APA OR APA RATED SHEATHING, <br />EXPOSURE 2. <br />2. PLYWOOD WALL SHEATHING SHALL BE C-D INT-APA WITH EXTERIOR GLUE. <br />3. SEE DRAWINGS FOR THE ABOVE PLYWOOD LOCATIONS AND THICKNESS. <br />EXECUTION <br />INSTALLATION: <br />A. STUD PARTITIONS (ALTERNATE TO METAL STUDS AS INDICATED ON DRAWINGS). <br />1. WOOD STUD PARTITIONS SHALL EXTEND TO THE UNDERSIDE OF ROOF DECK AND/OR <br />MEZZANINE FRAMING AND SHALL BE 16" O.C. UNLESS OTHERWISE NOTED. <br />2. STUDS AT DWARF PARTITIONS SHALL BE 2'-0" O.C. UNLESS OTHERWISE NOTED. BRACE <br />PARTITIONS BACK TO MASONRY WALLS AS INDICATED. <br />3. FURNISH SOLID WOOD BLOCKING IN PARTITIONS FOR ALL WALL MOUNTED EQUIPMENT, <br />HARDWARE, ETC. <br />4. FURNISH WOOD BLOCKING BETWEEN STUDS AS REQUIRED BY THE UNSUPPORTED <br />LENGTH OF THE STUDS. <br />SECTION 05400 <br />COLD FORMED METAL FRAMING <br />GENERAL <br />DESCRIPTION: <br />FURNISH ALL MATERIALS, LABOR, EQUIPMENT, SERVICES, ETC., NECESSARY AND INCIDENTAL <br />FOR THE COMPLETION OF ALL THE COLD FORM METAL FRAMING WORK AS INDICATED ON THE <br />DRAWINGS AND AS SPECIFIED HEREIN. <br />PRODUCTS <br />METAL FRAMING: <br />A. SYSTEM COMPONENTS <br />FURNISH MANUFACTURER'S STANDARD STEEL RUNNERS (TRACKS), BLOCKING, LINTELS, CLIP <br />ANGLES, SHOES, REINFORCEMENTS, FASTENERS, AND ACCESSORIES AS RECOMMENDED BY <br />MANUFACTURER FOR APPLICATIONS INDICATED, AS NEEDED TO FURNISH A COMPLETE METAL <br />FRAMING SYSTEM. ALL PRODUCTS TO BE MANUFACTURED BY THE CURRENT MEMBERS OF THE <br />STEEL STUD MANUFACTURERS ASSOCIATION. <br />B. ALL GALVANIZED STUDS SHALL BE FORMED FROM STEEL THAT CORRESPONDS TO THE <br />MINIMUM REQUIREMENTS OF 1996 A.I.S.I. STANDARDS. <br />C. MATERIALS AND FINISHES <br />FABRICATE METAL FRAMING COMPONENTS OF CORROSION RESISTANT STRUCTURAL QUALITY <br />STEEL SHEET. STEEL STUDS SHALL CONFORM TO ASTM A446, GRADE A, WITH A MINIMUM YIELD <br />POINT OF 33 KS1 FOR 18 AND 20 GAUGE; GRADE D WITH A MINIMUM YIELD POINT OF 50 KS1 FOR <br />12,14 AND 16 GAUGE. UNLESS SHOWN SPECIFICALLY ON DRAWINGS, ALL 20 AND 18 GAUGE <br />STUDS TO HAVE A MINIMUM OF 1-3/8" FLANGE, ALL 16 AND 14 GAUGE STUDS TO HAVE A <br />MINIMUM OF 1-5/8" FLANGE, AND 12 GAUGE STUDS TO HAVE A MINIMUM OF A 2" FLANGE. <br />EXECUTION <br />FABRACATION AND INSTALLATION <br />A. ALL FRAMING COMPONENTS SHALL BE CUT SQUARELY FOR ATTACHMENT TO <br />PERPENDICULAR MEMBERS OR AS REQUIRED FOR ANGULAR FIT AGAINST ABUTTING <br />MEMEBERS. <br />B. STUDS SHALL BE PLUMBED, ALIGHNED AND SECURELY ATTACHED TO FLANGES OF BOTH <br />UPPER AND LOWER RUNNERS. <br />C. IN ALL DOULBLED JAMBS AND HEADERS NOT ACCESSIBLE TO INSULATION CONTRACTORS, <br />INSULATION EQUAL TO THAT SPECIFIED ELSEWHERE SHALL BE PROVIDED. <br />D. TEMPORARY BRACING WHERE REQUIRED, SHALL BE PROVIDED UNTIL ERECTIONNIS <br />COMPLETE. <br />INSTALLATION (NON -BEARING WALLS) <br />A. RUNNERS SHALL BE SECURELY ANCHORED TO THE SUPPORTING STRUCTURE AS SHOWN IN <br />DRAWINGS. <br />B. JACK STUDS SHALL BE INSTALLED UNDER AND OVER DOORS AND WINDOWS, AND <br />ELSEWHERE TO FURNISH SUPPORT. <br />C. PROVISIONS FOR STRUCTURAL VERTICAL MOVEMENT SHALL BE PROVIDED <br />SECTION 08111 <br />STANDARD STEEL DOORS <br />GENERAL <br />DESCRIPTION: <br />A. FURNISH ALL MATERIALS, LABOR, EQUIPMENT, SERVICE, ETC., NECESSARY AND INCIDENTAL <br />FOR THE COMPLETION OF ALL STANDARD STEEL DOOR WORK AS SHOWN ON THE DRAWINGS <br />AND AS SPECIFIED HEREIN. <br />QUALITY ASSURANCE <br />A. FURNISH DOORS COMPLYING WITH STEEL DOOR INSTITUTE "RECOMMENDED <br />SPECIFICATIONS: STANDARD STEEL DOORS AND FRAMES" (ANSI/SDI 100-91). <br />SECTION 08112 <br />STANDARD STEEL FRAMES <br />GENERAL <br />DESCRIPTION: <br />A. FURNISH ALL MATERIALS, LABOR, EQUIPMENT, SERVICE, ETC., NECESSARY AND INCIDENTAL <br />FOR THE COMPLETION OF STANDARD STEEL FRAME WORK AS SHOWN ON THE DRAWINGS AND <br />AS SPECIFIED HEREIN. <br />QUALITY ASSURANCE: <br />FURNISH FRAMES COMPLYING WITH STEEL FRAME INSTITUTE "RECOMMENDED SPECIFICATIONS: <br />STANDARD STEEL FRAMES" (ANSI/SDI 100-91). <br />A. HOLLOW METAL DOOR FRAMES <br />1. HOLLOW METAL DOOR FRAMES SHALL BE FORMED FROM 18 GAUGE STEEL. FRAMES SHALL <br />BE FLUSH DOUBLE RABBETED TYPE WITH 5/8 DEEP STOPS AND 2" FACE. PROVIDE CASED <br />OPENING (WITHOUT RABBETED STOP) WHERE SCHEDULED. <br />A. FRAMES, IN MASONRY PARTITIONS, SHALL BE 18 GAUGE, SET UP UNIT TYPE WITH CORNERS <br />MITERED, ARC WELDED AND GROUND SMOOTH. PROVIDE SILL ANCHORS, SPREADERS, JAMB <br />ANCHORS AT 2-0" O.C. <br />B. FRAMES IN STUD PARTITIONS SHALL BE "DRYWALL TYPE" FRAMES DESIGNED TO BE INSTALLED <br />AFTER WALL IS UP. FRAMES SHALL HAVE MITERED INTERLOCKING CORNERS, COMPRESSION <br />TYPE JAMB ANCHORS, SILL ANCHORS AND DOUBLE RETURN ON THE BACK BEND TO GRIP AND <br />CAP WALL. <br />C. FRAMES FOR DOUBLE ACTING SERVICE DOORS SHALL BE UNIT TYPE WITH 12 GAUGE STEEL <br />REINFORCEMENT (HEAD AND JAMBS). <br />2. ALL FRAMES SHALL BE SUPPLIED WITH FACTORY INSTALLED RUBBER BUMPERS, THREE (3) PER <br />STRIKE JAMB AND TWO (2) PER HEAD FOR PAIR OF DOORS. <br />3. EXTERIOR DOOR FRAMES SHALL BE GALVANIZED STEEL. <br />4. FABRICATE FRAMES SQUARE, PLUMB AND TRUE. <br />MANUFACTURERS: <br />A. STEEL FRAMES <br />1. AMWELD <br />2. STEELCRAFT <br />3. CURRIES <br />4. CECO <br />5. REPUBLIC <br />6. MESKER <br />HARDWARE <br />A. TEMPLATES FOR HARDWARE WILL BE SHIPPED TO THE FACTORY FOR FABRICATION BY THE <br />DOOR AND FRAME MANUFACTURER. <br />1. REINFORCE, DRILL AND TAP DOORS TO RECEIVE MORTISED HARDWARE. SURFACE APPLIED <br />HARDWARE SHALL HAVE REINFORCING AS REQUIRED FOR DRILLING AND TAPPING BY INSTALLER. <br />2. PROVIDE PLASTER/DUST GUARDS FOR MORTISES IN FRAME, <br />FINISH <br />A. AFTER THOROUGHLY CLEANING AND CHEMICALLY TREATING SURFACES, APPLY ONE COAT OF <br />MANUFACTURER'S STANDARD PRIMER, BAKED ON. <br />SECTION 08710 <br />AUTOMATIC ENTRANCE DOORS <br />MATERIALS <br />A. AUTOMATIC DOOR SYSTEM SHALL BE SLIDING BI-PARTING ALUMINUM DOORS AND <br />SIDELIGHTS, TRANSOM, HEADERS, OPERATORS AND ACTUATING CONTROLS. <br />1. SLIDING DOOR AND SIDELIGHTS SHALL BE BREAKOUT DESIGN. <br />B. ALUMINUM DOORS AND FRAMES <br />1. DOORS AND FRAMES SHALL BE EXTRUDED ALUMINUM, MAJOR SECTIONS SHALL BE <br />MINIMUM, 125" WALL THICKNESS. <br />2. DOORS AND SIDELIGHTS SHALL BE MEDIUM STILE AND FURNISHED WITH TWO MUNTIN <br />BARS,10" BOTTOM RAILS, NYLON BRUSH BOTTOM SWEEPS. <br />A. AT EXTERIOR DOORS FURNISH WEATHER-STRIPPING AT ALL STILES AND HEADER. <br />3. ALL OPERATING EQUIPMENT SHALL BE FACTORY ASSEMBLED, ADJUSTED AND TESTED. <br />4. DOORS SHALL INCLUDE ALL HARDWARE, PIVOTS, ROLLERS, MOUNTING COMPONENTS, ETC. <br />A. FURNISH THUMBTURN CYLINDERS ON INSIDE OF EXTERIOR ALUMINUM DOORS. <br />5. INCLUDE 1/2" MAXIMUM RAISED THRESHOLDS WITH BEVELED EDGES AT EXTERIOR DOORS <br />(EXCEPT AT ENTRANCE MAT WHERE THRESHOLD IS SQUARE EDGE). <br />6. INCLUDE ALL DECALS ON DOORS AS REQUIRED BY ANSI AND NFPA. <br />7. DOOR MANUFACTURER TO SUPPLY MAGNETIC CONTACT SWITCH, SENTROL 1078W, AND <br />PREPARE DOORS AND HEAD FRAME TO RECEIVE MAGNETIC CONTACT SWITCH AND <br />WIRING.ROUTE WIRING THROUGH HEAD FRAME AND INTO FIXED LEAF TO ALLOW FOR FINAL <br />CONNECTION BY KMART AT HEADERAON WIRED MAGNET TO BE LOCATED IN ACTIVE <br />LEAF. LOCATE HOLES FOR MAGNETIC SWITCH A MINIMUM 15 INCHES BELOW TOP HINGE <br />MOUNTING POINT, SEE DRAWINGS FOR LOCATION. MANUFACTURERS <br />A. STANLEY MAGIC -DOOR, "DURA-GLIDE" SERIES 3000, MODEL 10-3360 <br />B. BEAAM, INC., "POWERGLIDE AMD" <br />C. GYRO -TECH, INC., "GT SYSTEM 1175" <br />D. DOR-O-MATIC, DIVISION OF INGERSOLL RAND, "96K SLIDING DOOR SYSTEM" <br />FINISHES <br />A. DOORS AND FRAMES <br />1. FINISH SHALL MATCH EXISTING ADJACENT. <br />OPERATORS <br />1. OPERATORS SHALL BE ELECTRO-MECHANICAL ACTIVATED BY MOTION/PRESENCE DETECTORS <br />AT HEADER FOR ONE-WAY AND TWO-WAY TRAFFIC, SURFACE MOUNTED. <br />A. EXIT DOORS <br />1. FURNISH "EXIT ONLY" DECALS ON EXTERIOR SIDE OF DOOR AND "ARROW" DECAL INSIDE. <br />B. TWO-WAY DOORS <br />1. FURNISH "ARROW" DECALS ON BOTH SIDES OF DOORS, <br />C. ALL DECALS CONFORM TO ANSI/A156.10-LATEST EDITION. <br />D. APPROACH SIDE OF DOOR FURNISH DECAL "CAUTION AUTOMATIC DOOR" AND ON EGRESS <br />SIDE FURNISH "EMERGENCY PUSH TO OPEN" <br />2. INCLUDE FULL OPENING SAFETY THRESHOLD/PRESENCE DETECTION. 3. SYSTEM SHALL <br />INCLUDE DOOR HOLD -OPEN DEVICE AND ON/OFF SWITCH AT HEADER. <br />4. ALL AUTOMATIC EQUIPMENT AND FUNCTIONS SHALL COMPLY WITH ANSI-A156.10- LATEST <br />EDITION. <br />SAFETY EQUIPMENT <br />1. ACTIVATION SENSOR <br />A. ACTIVATION CAN BE NO LESS THAN 43" OUT FROM CLOSED DOOR AND LESS 5" ON EITHER <br />SIDE OF DOOR OPENING WIDTH. <br />B. DETECTION CAN BE NO LESS THAN 28" OFF FINISHED FLOOR. <br />2. HEADER MOUNTED SAFETY SENSOR <br />A. MUST BE MOUNTED ON SWING SIDE OF THE DOOR OPENING <br />B. SENSORR IS LOCATED ON PACKAGE HEADER <br />C. SAFETY ZONE IS SET AT 45 ^ OUT FROM CLOSED DOOR AND LEESS 5" ON EITHER SIDE OF <br />DOOR OPENING WIDTH <br />D. SENSOR MUST BE ABLE TO DETECTOR OBJECT 28" OR HIGHER <br />E. SENSOR PROTECTS 5" THROUGH THE THRESHOLD IN THE DOORS OPEN POSITION. <br />3. SAFETY BEAMS <br />A. BEAMS KEEP THE DOOR FROM CLOSING WHEN AN OBJECT IS IN THE THRESHOLD AREA <br />DOOR WILL REACTIVATE IF AN OBJECT IS <br />DETECTED IN THE SAFETY ZONE. <br />SECTION 08710 <br />FINISH HARDWARE <br />GENERAL <br />DESCRIPTION <br />A. FURNISH ALL MATERIALS, LABOR, EQUIPMENT, SERVICE, ETC., NECESSARY AND INCIDENTAL <br />FOR THE COMPLETION OF ALL FINISH HARDWARE WORK AS SHOWN ON THE DRAWINGS AND AS <br />SPECIFIED HEREIN. - <br />QUALITY ASSURANCE <br />A. REQUIREMENTS OF REGULATORY AGENCIES: FURNISH FINISH HARDWARE TO COMPLY WITH <br />THE REQUIREMENTS OF LAWS, CODES, ORDINANCES, AND REGULATIONS OF THE <br />GOVERNMENTAL AUTHORITIES HAVING JURISDICTION WHERE SUCH REQUIREMENTS EXCEED THE <br />REQUIREMENTS OF THE SPECIFICATIONS. <br />A. FURNISH EACH CATEGORY WITH THE PRODUCTS OF ONLY ONE MANUFACTURER; THIS <br />REQUIREMENT IS MANDATORY WHETHER VARIOUS MANUFACTURERS ARE LISTED ON NOT. <br />B. HINGES: FURNISH CLASS AS SPECIFIED IN HARDWARE SETS IN SIZE <br />4-1/2 X 4-1/2 INCHES FOR 1-3/4" DOORS. FURNISH NON -REMOVABLE PINS (NRP) FOR HINGES ON <br />EXTERIOR OUT SWINGING DOORS. <br />HAGER LAWRENCE MCKINNEY STANLEY <br />H-1 1279 4181 T27143 F179 <br />H-2 BB1279 BB4101 TB27143 FBB179 <br />C. LOCKSETS AND LATCHSETS: <br />1. MORTISE: SERIES AND FUNCTION DESIGNATIONS ARE BEST (NO SUBSTITUTION). <br />MANUFACTURER SERIES DESIGN <br />BEST 35H 15H <br />2. BEST HEAVY DUTY CYLINDRICAL: SERIES AND FUNCTION DESIGNATIONS ARE BEST (NO <br />SUBSTITUTION). <br />MANUFACTURER SERIES DESIGN <br />BEST 9K 15D <br />D. KICK PLATES: FURNISH 10" X 0.050 INCHES X DOOR WIDTH LESS 1-1/2" AT SINGLE DOORS, AND <br />LESS ONE INCH AT PAIRS. WHERE GLASS OR LOUVERS PREVENT THIS HEIGHT, SUPPLY WITH <br />HEIGHT EQUAL TO HEIGHT OF BOTTOM RAIL LESS ONE INCH. <br />E. WALL STOPS: B.H.M.A. L12101. WROUGHT, FORGED, OR CAST. APPROXIMATELY 2-1/2" <br />DIAMETER, CONVEX OR CONCAVE RUBBER CENTER, CONCEALED FASTENERS. <br />F. FINISHES: EXTERIOR HINGES, PRIME COAT, USP, OVER MANUFACTURER'S RUST RESISTING <br />BASE: HAGER CP, LAWRENCE CB, MCKINNEY S, STANLEY K. INTERIOR HINGES, ALUMINUM <br />LACQUER: HAGER LS, LAWRENCE LT, MCKINNEY AP, STANLEY LA. DOOR SPRINGS, <br />MANUFACTURER'S STANDARD, FLUSH BOLTS, LOCKSETS, CARRY BARS, DULL CHROME, US26D. <br />KICK PLATES, FLOOR STOPS, WALL STOPS AND HOLDERS, WEATHER-STRIPPING, ANODIZED <br />ALUMINUM, US28. THRESHOLDS, EXTRUDED ALUMINUM, MILL FINISH. CLOSERS, SPRAYED <br />ALUMINUM. AT EXTERIOR DOORS, PROTECT ALL CLOSER CYLINDERS (IF FERROUS), ARMS AND <br />PLATES WITH SPECIAL RUST INHIBITING (SRI) FINISH PRIOR TO FINAL SPRAYED ALUMINUM. <br />EXECUTION <br />GENERAL <br />A. INSTALL HARDWARE ACCORDING TO MANUFACTURER'S PRINTED INSTRUCTIONS AND TO <br />TEMPLATE DIMENSIONS. <br />QUANTITIES <br />A. PROVIDE ONE HINGE FOR EACH 30 INCHES OF DOOR HEIGHT OR FRACTION THEREOF. <br />EXECUTION <br />GENERAL <br />A. INSTALL HARDWARE ACCORDING TO MANUFACTURER'S PRINTED INSTRUCTIONS AND TO <br />TEMPLATE DIMENSIONS. <br />QUANTITIES <br />A. PROVIDE ONE HINGE FOR EACH 30 INCHES OF DOOR HEIGHT OR FRACTION THEREOF. <br />SECTI ON07460 <br />EXTERIOR SIDING PANELING <br />EXTERIOR CEMENT FIBER VERTICAL SIDING PANELS <br />DESCRIPTION <br />A. FURNISH ALL MATERIALS LABOR, EQUIPMENT, SERVICE, ETC., NECESSARYAND INCIDENTAL <br />FOR THE COMPLETION OF ALL THE EXTERIOR SIDING PANELS AS INDICATED ON THE DRAWINGS <br />AND AS SPECIFIED HEREIN. <br />DELIVERY, STORAGE AND HANDLING <br />A. PROTECT INSULATION FROM PHYSICAL DAMAGE AND FROM BECOMING WET, SOILED OR <br />COVERED WITH ICE OR SNOW. COMPLY WITH MANUFACTURER'S RECOMMENDATIONS FOR <br />HANDLING, STORAGE AND PROTECTION DURING INSTALLATION. <br />B. LABEL INSULATION PACKAGES TO INCLUDE MATERIAL NAME, PRODUCTION DATE AND/OR <br />PRODUCT CODE. <br />C. STACK SIDING PANELS ON A LEVEL SURFACE. PROTECT EDGES AND CORNERS FROM <br />CHIPPING. <br />JOB CONDITIONS <br />A. IT WILL BE THE RESPONSIBILITY OF THIS CONTRACTOR TO COORDINATE AND SCHEDULE THE <br />EXTERIOR SIDING PANEL INSTALLATION WITH THE GENERAL CONTRACTOR SO AS TO PROVIDE FOR <br />A SMOOTH AND ORDERLY PROGRESSION OF THE WORK PRODUCTS <br />MATERIALS <br />A. EXTERIOR SIDING PANELS SHALL BE UNPRIMED, SINGLE FACED, CELLULOSE FIBER <br />REINFORCED CEMENT BUILDING BOARDS.. <br />B. SIDING PANELS SHALL COMPLY WITH ASTM STANDARD SPECIFICATION C1186, GRADE II, TYPE A <br />C. SIDING PANELS ARE TO BE NON-COMBUSTIBLE WHEN TESTED IN ACCORDANCE WITH ASTM <br />E136. <br />ACCESSORIES <br />A. "Z BAR" METAL FLASHING @ HORIZONTAL JOINTS <br />MANUFACTURERS <br />A. EXTERIOR SIDING PANELS <br />1. JAMES HARDIE BUILDING PRODUCTS, "HARDIE PANEL SIERRA 8", 4'X8' VERTICAL <br />SIDING PANEL" <br />2. CERTAINTEED, "8" O.C. CEDAR PANEL 4'X8" <br />3. MAXITILE, "MAXI PANEL 4'X8', V GROOVE 8" O.C." <br />FINISHES <br />A. SIDING PANELS ARE TO BE PAINTED WITH PRIME AND FINISH COAT: <br />1. PRIME COAT - (1 COAT): <br />A. PRATT & LAMBERT, "PRO -HIDE GOLD LATEX PRIMER" (Z8460 SERIES <br />B. PITTSBURGH PAINT, "SPEEDHIDE EXTERIOR LATEX WOOD PRIMER" (6-609 <br />SERIES) <br />C. SHERWIN WILLIAMS, "PREP RITE PRO BLOCK" LATEX PRIMER (1351W20) <br />D. BENJAMIN MOORE, "MOORECRAFT SUPER SPEC LATEX EXTERIOR PRIMER" (PRODUCT <br /># 169) <br />E. ICI DULUX, GRIPPER (PRODUCT #3210) <br />2. FINISH COAT - (2 COATS TO PROVIDE FULL HIDING COVERAGE): <br />A. PRATT & LAMBERT, "PRO -HIDE SILVER FLAT" <br />B. PITTSBURGH PAINTS, "SPEEDHIDE, FLAT LATEX HOUSE PAINT" (6-610 SERIES) <br />C. SHERWIN WILLIAMS, "A-100 LATEX FLAT" (A6 SERIES) <br />D. BENJAMIN MOORE, "MOORECRAFT SUPER SPEC EXTERIOR LATEX FLAT" (PRODUCT #189) <br />E. ICI DULUX, "ULTRA -HIDE DURUS" (PRODUCT #2220) <br />EXECUTION <br />EXAMINATION <br />A. CORRECT CONDITIONS DETRIMENTAL TO TIMELY AND PROPER COMPLETION OF <br />WORK. INSTALLATION <br />A. BLOCK FRAMING BETWEEN STUDS WHERE SIDING PANEL HORIZONTAL JOINTS OCCUR. <br />B. PLACE FASTENERS NO CLOSER THAN 1/2" FROM PANEL EDGES AND 2 INCHES FROM PANEL <br />CORNERS. <br />C. ALLOW MINIMUM 1 INCH VERTICAL CLEARANCE BETWEEN ROOFING AND BOTTOM EDGE OF <br />SIDING. <br />D. MAINTAIN CLEARANCE BETWEEN SIDING AND ADJACENT FINISHED GRADE. <br />E. SPECIFIC FRAMING AND FASTENER REQUIREMENTS REFER TO TABLES 2 AND 3 IN NATIONAL <br />EVALUATION SERVICE REPORT NO. NER-405. <br />F. PER MANUFACTURERS REQUIREMENTS, VERTICAL JOINTS ARE TO BE BUTT JOINTS WITH <br />SEALANT AND HORIZONTAL JOINTS ARE TO BE "Z BAR" METAL FLASHING. <br />U') <br />co <br />1' , <br />•0.Sr, <br />cd �4 <br />CD <br />L <br />0- 4 <br />Q <br />O � <br />aD <br />_ <br />a <br />O <br />co <br />> <br />aj � <br />w o <br />CO <br />w <br />, .Ln <br />W .> <br />= <br />V) <br />P/ <br />m <br />co <br />a <br />F4 <br />co <br />m <br />U <br />Q <br />fit <br />o <br />U) <br />x <br />W <br />Z <br />0 <br />Q <br />U <br />u- <br />C..) <br />W <br />0- <br />Cn <br />J <br />LL <br />U <br />ui <br />= <br />U <br />Of <br />Q <br />Q <br />0 <br />ry <br />0 <br />J <br />Li- Q <br />/ � <br />I..L <br />J <C <br />J_ Lu <br />_��// J <br />L.L <br />>- 0 <br />= <br />UJ J <br />N J <br />1 V_V �n <br />� 0.4 <br />4t r--- <br />Ln <br />O <br />Cr) <br />0') <br />i <br />Q <br />00 <br />L <br />Lii <br />co <br />CIO <br />d- <br />D <br />z <br />zz <br />Q0 <br />I- <br />'S <br />U <br />> <br />Ir <br />CQ <br />��ezzLLI <br />wzQ�Q <br />F= L1J ~ <br />= a-� <br />C'7 <br />fr <br />� <br />Iz <br />0 <br />fZ <br />� LLr) <br />Q cn Lo <br />U <br />IL <br />Project Arch.l Engineer: <br />R. THORNTON <br />Drawn: <br />RKT <br />Checked: <br />JOHN LINEGAR <br />Date: <br />JANUARY 17, 2007 <br />Sheet No: <br />