My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7422 Gall Blvd (8)
Zephyrhills
>
Building Department
>
Building Plans
>
7422 Gall Blvd (8)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 1:32:33 PM
Creation date
2/18/2025 4:06:28 PM
Metadata
Fields
Template:
Building Plans
Street #
7422
Location
Gall Blvd
Contractor
Gunther General Contr
Building Plans - Permit #
6428
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REVISIONS <br />BIDDERS PRINTS ISSUED I <br />JANUARY V. M <br />PLUMBING FIXTURE SCHEDULE <br />FIXTURE <br />TRAP <br />VENT <br />CW <br />HW <br />FW <br />MANUFACTURER <br />MODEL <br />REMARKS <br />WC-1 <br />4" <br />2" <br />1/2" <br />AMERICAN STANDARD <br />2377.100 <br />FLOOR MOUNTED PRESSURE ASSISTED FLUSH ACTION TANK (ELONGATED BOWL) W <br />WATER CLOSET <br />BENEKE MODEL 527 SEAT OPEN FRONT AND TANK COVER WITH LOCKING DEVICE <br />ELECTRIC WATER COOLER <br />EWC-1 <br />1-1/2" <br />1-1/2" <br />1/2" <br />ELKAY <br />EBFA8 <br />LO WALL MOUNTED TYPE, ADA COMPLANT. <br />LAV-1 <br />WALL -HUNG LAVATORY <br />1-1/2" <br />1/2" <br />1/2" <br />AMERICAN STANDARD <br />0356.028 <br />FAUCET PROVIDED WITH SINK. <br />H <br />NEW WATER CLOSET (2) <br />TRAINING RECONNECT TO EXISTING UNDERGROUND <br />WASTE, CW AND VENT LINES IN CHASE. VERIFY <br />EXACT LOCATION IN FIELD, INSTALL PER <br />MANUFACTURERS RECOMMENDATIONS AND <br />LOCAL CODE REQUIREMENTS. <br />WC-1 v V f WC-1 NEW LAVATORY (2) <br />CONNECT TO EXISTING WASTE, CW, HW AND <br />WOMEN VENT LINES IN CHASE. VERIFY EXACT LOCATION <br />TOILET IN FIELD. INSTALL PER MANUFACTURERS <br />RECOMMENDATIONS AND LOCAL CODE <br />MEN REQUIREMENTS. <br />LAV-1 kLV-1 TOILET <br />R CLOSETS (4) <br />ND REMOVE EXISTING WATER <br />%D CAP EXISTING PIPING BELOW <br />SIDE CHASE. PATCH FLOOR AND WALL nn <br />TING SURFACE. L� <br />O <br />0 <br />0 <br />0 0 <br />Lo 0 0 <br />EWC-1 <br />3 <br />NEW ELECTRIC WATER COOLER <br />DISCONNECT AND REMOVE EXISTING WATER CONNECT TO EXISTING WASTE, CW AND VENT <br />CCOOLER. CUT AND CAP EXISTING PIPING INSIDE LINES IN CHASE. VERIFY EXACT LOCATION IN <br />WALL. PATCH WALL TO MATCH EXISTING SURFACE. FIELD. INSTALL PER MANUFACTURERS <br />RECOMMENDATIONS AND LOCAL CODE <br />REQUIREMENTS. <br />TOILETS FLOOR PLAN - DEMOLITION TOILETS FLOOR PLAN - NEW WORK <br />SCALE:1/4" = 1'-0" SCALE:1/4" =1'-0" <br />DEMOLITION <br />1. ALL REMOVED EQUIPMENT SHALL BECOME THE PROPERTY OF THE CONTRACTOR. <br />2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFE REMOVAL AND LEGAL <br />DISPOSAL OF REFRIGERANT FROM THE DEMOLISHED UNITS. <br />PLUMBING NOTES: <br />1. PLUMBING CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS. <br />2. PLUMBING INSTALLATION SHALL COMPLY WITH ALL LOCAL CODES. <br />3. INSTALL NEW PLUMBING LINES TO CONNECT NEW PHARMACY'S HAND SINK, ELECTRIC <br />WATER HEATER AND SUMP PUMP. <br />4. NEW SANITARY AND VENT PIPING SHALL BE PVC SCHEDULE 40. <br />5. NEW DOMESTIC WATER LINES SHALL BE TYPE "L" HARD COPPER WITH SOLDERED COPPER <br />JOINTS AND FITTINGS. <br />6. CONTRACTOR SHALL PROVIDE A CLEAN OUT FOR THE WASTE LINE EVERY 90' AND EVERY <br />CHANGE IN DIRECTION. <br />7. NEW PIPING SHALL RUN CONCEALED IN FINISHED AREAS, <br />8. PROVIDE 1/2" THICK FIBERGLASS PIPE INSULATION WITH VAPOR BARRIER JACKET ON NEW <br />WATER LINE. <br />10. CONTRACTOR SHALL VERIFY THAT EXISTING PLUMBING SYSTEM CAN ACCOMMODATE <br />NEW FIXTURES. MODIFY WATER LINES AS REQUIRED FOR NEW WATER CLOSETS AND URINAL <br />FLUSH VALVES PER WATER DEMAND REQUIREMENTS. <br />GENERAL NOTES: <br />1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS. <br />2. EXISTING FOOD DEPT. EQUIPMENT TO BE REMOVED <br />COMPLETELY (UNLESS OTHERWISE NOTED). WORK SHALL <br />INCLUDE BUT NOT LIMITED TO REMOVAL OF THE FOLLOWING: <br />A. ALL SERVING LINE AND PREP. ROOM EQUIPMENT <br />INCLUDING WATER HEATER AND GREASE INTERCEPTOR. <br />B. EXHAUST HOOD &ASSOCIATED DUCTWORK AND FANS. <br />C. ALL EXPOSED WATER LINES IN FINISHED AREAS. <br />D. ALL ABOVE FLOOR SANITARY AND VENT PIPING TO BELOW <br />FINISHED FLOOR OR TO ROOF. <br />E. ALL FLOOR DRAINS SHALL BE REMOVED AND SEWER CAPPED <br />AND ABANDONED BELOW FINISHED FLOOR. <br />NOTE: ALL PIPING IN FLOOR SHALL BE CAPPED AND ABANDONED <br />BELOW FINISHED FLOOR, ALL ROOF OPENINGS SHALL BE CAPPED. <br />EXHAUST HOOD SUPPLY AND EXHAUST FANS SHALL BE <br />DISCONNECTED AND REMOVED. SEAL FAN CURBS WITH A <br />WEATHER TIGHT INSULATED CAP PER DETAIL ON THIS DRAWING. <br />SUPPLY AND EXHAUST AIR DUCTS CONNECTED TO EXHAUST <br />HOODS SHALL BE ABANDONED IN CEILING SPACE. <br />SEE TOILET FLOOR <br />PLANS ON THIS <br />DRAWING FOR <br />DEMO AND NEW <br />WQRI' IAI 7U10 AOCA <br />C!] <br />co <br />LL�Ljjj <br />OEn <br />C <br />111/ <br />C <br />�I +y <br />w o <br />O <br />> vs <br />x <br />cd <br />Lo <br />Q <br />U) <br />Z <br />Q <br />J <br />Lu <br />J <br />0 <br />Q <br />0 <br />ry <br />0 <br />J <br />L.L �C/ <br />I..L <br />J Q <br />J_ <br />= J <br />r <br />O <br />m <br />n <br />L1J J <br />N J <br />Q <br />CD <br />co N <br />1` N <br />M <br />L <br />Project Arch./ Engineer: <br />R.THORNTON <br />Drawn: <br />L.SEMENYUK <br />Checked: <br />D. STYCZYNSKI <br />Date: <br />JANUARY 17, 2007 <br />KEY PLAN <br />SCALE:1/64" =110° <br />Sheet No: <br />
The URL can be used to link to this page
Your browser does not support the video tag.