My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Summerset Apartments (3)
Zephyrhills
>
Building Department
>
Building Plans
>
Summerset Apartments (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 11:11:06 AM
Creation date
2/18/2025 4:10:31 PM
Metadata
Fields
Template:
Building Plans
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
183
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FLOOR i CEILING ASSEMBLIES <br />CD <br />U <br />E MASONRY WALL ASSEMBLIES <br />TYP. @ ELEVATOR HOISTWAY @ CORRIDOR <br />WM-4 <br />2 HOUR <br />RATED <br />- 1. (1) LAYER 1/2" GYP BD <br />= = 2. CONTINUOUS RADIANT FOIL R-7 INSULATION <br />UNDERWRITER'S <br />LABORATORY <br />3. 1 112" FURRING AT 16" OC <br />4. 8"2 HR CMU PER STRUCTURAL <br />DESIGN U905 <br />CORRIDOR <br />HOISTWAY <br />TYP. @ ELEVATOR HOISTWAY @ UNITS <br />WM-5 <br />2 HOUR <br />RATED <br />1. 8112 HR CMU PER STRUCTURAL <br />UNDERWRITER'S <br />2. 2x WOOD STUDS @ 16 OC. REFER TO STRUCTURAL <br />LABORATORY <br />3. R-19 UNFACED BATT INSULATION (COMPRESSED TO EFFECTIVE R-13 AT 2x4 <br />DESIGN U905 <br />WALLS) <br />G <br />4. 5/8" FIRE RATED GYPSUM BOARD <br />HOISTWAY <br />UNIT <br />[7- <br />TYP. @ EXTERIOR WALLS @ DUMPSTER ENCLOSURE <br />WM-6 <br />NON RATED <br />- 1. 5/8" MIN DIRECT APPLY CEMENT PLASTER FINISH <br />-:. 2. 8" CMU PER STRUCTURAL DRAWINGS <br />- 3. PAINT OVER BLOCK <br />EXT INT. <br />E FRAME WALL ASSEMBLIES <br />TYP. @ TENANT SEPARATION <br />WF-1 <br />1. (1) LAYER 5/8" FIRE -RATED GYP. BD. (EXT. GRADE AT UNCONDITIONED SPACE) <br />2. DOUBLE WOOD STUDS STAGGERED @ 16" O.C. MAX. WITH 2X10 TOP PLATE. <br />1 HOUR <br />, ; REFER TO STRUCTURAL. j <br />RATED <br />3. R-13 KRAFT FACED BAIT INSULATION ON ONE SIDE. AT INTERVALS NOT <br />EXCEEDING 10 FEET HORIZONTALLY, SECURELY INSTALL INSULATION ACROSS <br />CALCULATED <br />CAVITY TO OPP. WALL TO PROVIDE FIREBLOCKING IN CONCEALED SPACES. <br />ASSEMBLY PER <br />4. (1) LAYER 5/8" FIRE -RATED GYP. BD. (EXT. GRADE @UNCONDITIONED SPACE) <br />FBC 721.6.2 <br />INT ! INT. <br />C <br />MATERIAL RATING (MINUTES) <br />STC 55 PER TL-93-265 <br />2x4 WOOD STUDS @ 16" O.C. 20 <br />1 LAYER 5/8" FIRE RATED GYPSUM WALLBOARD 40 <br />TOTAL TIME 60 <br />TYP. @ RATED PARTITIONS <br />WF-2 <br />1 HOUR <br />RATED <br />1. (1) LAYER 5/8" FIRE RATED GYPSUM BOARD <br />UNDERWRITER'S <br />2. 2x WOOD STUD FRAMING AT 16" O.C. MAX. REFER TO STRUCTURAL <br />LABORATORY <br />DESIGN U305 <br />C <br />.. .. <br />3. R-19 INSULATION AT PUMP ROOM TO UNIT <br />4. 1 LAYER 5/8" FIRE RATED GYPSUM BOARD I <br />( ) <br />INT. <br />�.......,- <br />INT. <br />TYP. @ INTERIOR PARTITIONS <br />WF-3 <br />NON RATED; <br />1. (1) LAYER 1/2" GYPSUM BOARD <br />2. 2X WOOD STUDS @ 24" O.C. MAX., REFER TO STRUCTURAL <br />3. (1) LAYER 1/2" GYPSUM BOARD <br />4. R-13 BATT INSULATION BETWEEN CONDITIONED AND UNCONDITIONED SPACES <br />INT <br />C = ,.. <br />INT. <br />TYP. DRAFT STOPPING @ ATTIC <br />WF-4 <br />NON RATED <br />DRAFTSTOP <br />1. (1) LAYER 7116" OSB ON ONE SIDE, U.N.O. <br />2. WOOD TRUSS W/ VERTICAL MEMBERS @ 24" O.C. MAX. <br />WF-5 <br />TYP. @ INTERIOR FURR-OUTS <br />NON RATED <br />1. (1) LAYER 1/2" GYPSUM BOARD <br />2. WOOD STUDS @ 16" O.C. MAX, REFER TO STRUCTURAL <br />INT. <br />CAVITY <br />I <br />TYP. @ UNITS <br />FC-1 <br />1. 3/4" GYP-CRETE TOPPING* <br />1 HOUR <br />2. 3/4" EXT. GRADE T&G PLYWOOD FLOOR SHEATHING <br />RAT ED <br />3. 20" WOOD FLOOR TRUSSES @ 24" O.G. MAX. <br />4. R-11 UNFACED BATT INSULATION <br />UNDERWRITER'S <br />/ � 5. RESILIENT CHANNELS @ 12" O.C. MAX., PERP. TO TRUSSES ! <br />LABORATORY <br />DESIGN L546 (SYSTEM #1) <br />I / 6. (1) LAYER 5/8" FIRE -RATED GYPSUM BOARD <br />/ V <br />" *PROVIDE ROVIDE UL SPECIFIED SOUND CONTROL MAT TO ACHIEVE:.IC-50 AS <br />FSTC 57" (98.67280.10) <br />j REQUIRED PER CODE AT UPPER FLOORS. IF UNDER-GYPCRETE MAT IS <br />FIIC 50* (98.67280.1) <br />PROVIDED, GC TO COORDINATE FINISH FLOOR ELEVATIONS WITH MAT & <br />REQUIRED GYPCRETE THICKNESS. <br />TYP. @ CORRIDOR <br />FC-2 <br />j <br />1. 3/4" GYP-CRETE TOPPING* <br />1 HOUR <br />2. 3/4" EXT. GRADE T&G PLYWOOD FLOOR SHEATHING <br />RATED <br />3. 20" WOOD FLOOR TRUSSES @ 24" O.C. MAX. <br />4. R-11 UNFACED BATT INSULATION <br />UNDERWRITER'S <br />5. RESILIENT CHANNELS @ 12" O.C. MAX., PERP. TO TRUSSES <br />LABORATORY <br />6. (1) LAYER 5/8" FIRE -RATED GYPSUM BOARD <br />DESIGN L546 (SYSTEM #1) <br />* PROVIDE UL SPECIFIED SOUND CONTROL MAT TO ACHIEVE IIC-50 AS <br />FSTC 57* (98.67280.10) <br />REQUIRED PER CODE AT UPPER FLOORS. IF UNDER-GYPCRETE MAT IS <br />RIC 50* (98.67280.1) <br />PROVIDED, GC TO COORDINATE FINISH FLOOR ELEVATIONS WITH MAT & <br />REQUIRED GYPCRETE THICKNESS. <br />TYP. @ STAIR LANDING <br />FC-3 <br />1 HOUR <br />1. 1 1/2" LIGHTWEIGHT CONCRETE ON ELAS I OMERIC MEMBRANE <br />RATED <br />! 2. 3/4" EXT. GRADE T&G PLYWOOD FLOOR SHEATHING <br />3. 191/4" WOOD FLOOR TRUSSES @ 24" O.C. MAX. <br />UNDERWRITER'S <br />4. RESILIENT CHANNELS @ 16" O.C. MAX., PERP. TO TRUSSES <br />LABORATORY <br />5. (1) LAYER 5/8" FIRE -RATED GYPSUM BOARD <br />DESIGN L528 (SYSTEM #1) <br />X� <br />FC-4 <br />i YP. @BALCONIES ---- I <br />- - 1. 1 1/2" LIGHTWEIGHT CONCRETE ON DRAINAGE MAT OVER <br />1 HOUR <br />ELASTOMERIC MEMBRANE <br />RATED <br />2. 3/4" EXT. GRADE T&G PLYWOOD FLOOR SHEATHING <br />-- 3. WD. FLOOR TRUSSES, W/ SLOPED TOP CHORD (16" @ DOOR T015"@ <br />UNDERWRITER'S <br />BALCONY EDGE) SPACED PER STRUCTURAL * I <br />LABORATORY <br />4. RESILIENT CHANNELS @ 16" O.C. MAX., PERP. TO TRUSSES <br />DESIGN L528 <br />5. (1) LAYER 5/8" FIRE -RATED EXT. GRADE GYPSUM BOARD <br />(SYSTEM #1) <br />*(AT UNIT B5-UFAS & C2-UFAS BALCONY WD FLOOR TRUSS W/ SLOPED TOP CHORD <br />191/2" @ WALL T0181/4" @ BALCONY EDGE SPACED PER STRUCTURAL) <br />MASONRY WALL ASSEMBLIES <br />TYP. @ EXTERIOR WALLS @ DUMPSTER <br />ROOM <br />WM-1 <br />2 HOUR <br />RATED <br />1. <br />FIBER CEMENT SIDING OVER BUILDING WRAP <br />2. <br />2x PT FURRING @ 16" OC <br />UNDERWRITER'S <br />3. <br />8" 2 HR CMU PER STRUCTURAL <br />LABORATORY <br />4. <br />PAINT OVER STRUCK BLOCK <br />DESIGN U905 <br />EXT INT. <br />TYP. FIREWALL I BUILDING SEPARATION & DUMPSTER ROOM <br />WM-2 <br />2 HOUR <br />I 1. <br />(1) LAYER 1/2" GYP BD <br />RATED <br />2. <br />CONTINUOUS RADIANT FOIL R-7 INSULATION <br />3. <br />1 1/2TFURRING 6 OC <br />UNDERWRITER'S <br />4. <br />8" 2 HR CMU PER STRUCTURAL <br />LABORATORY <br />5. <br />1 1/2" FURRING AT 16" OC <br />DESIGN U905 <br />6. <br />CONTINUOUS RADIANT FOIL R-7 INSULATION ! <br />j <br />I = 7. <br />(1) LAYER 1/2" GYP BD ! <br />1 <br />(OMIT <br />FURRING AND GYP BD AT INTERIOR ATTIC SPACE) <br />TYP. FIREWALL / BUILDING SEPARATION <br />@ UNITS <br />WM-3 <br />1. <br />(1) LAYER 1/2" GYP BD <br />2 HOUR <br />2. <br />CONTINUOUS RADIANT FOIL R-7 INSULATION <br />RATED <br />3. <br />1 1/2" FURRING AT 16" OC <br />4. <br />8" 2 HR CMU PER STRUCTURAL <br />UNDERWRITER'S <br />5. <br />2x WOOD STUDS @ 16" OC. REFER TO STRUCTURAL <br />LABORATORY <br />- <br />6. <br />R-19 UNFACED BATT INSULATION (COMPRESSED TO EFFECTIVE R-13 AT 2x4 <br />DESIGN U905 <br />l: <br />WALLS) <br />7. <br />5/8" FIRE RATED GYPSUM BOARD <br />i <br />j <br />CORRIDOR <br />UNIT <br />TYP. AT UNITS I CORRIDOR <br />RC-1 <br />1 HOUR RATED <br />1. <br />-- <br />TPO ROOF MEMBRANE <br />2. <br />R30 POLYSSOCYANURATE INSULATION <br />UNDERWRITER'S <br />-- 3. <br />5/8" EXTERIOR GRADE PLYWOOD SHEATHING <br />LABORATORY <br />UNVENTED 4. <br />WOOD ROOF TRUSSES @ 24" OC MAX (SLOPE TOP CHORD 1/4" PER FT MIN) <br />DESIGN P522 <br />ATTIC 5. <br />RESILIENT CHANNELS @ 16" OC MAX, PERPENDICULAR TO TRUSSES <br />6. <br />(1) LAYER 5/8" FIRE -RATED GYPSUM BOARD <br />i <br />TYP. @ CLUBHOUSE <br />RC-2 <br />PEON RATED <br />1. <br />30 YEAR ARCHITECTURAL FIBERGLASS/ASPHALT SHINGLES ON NO.30 FELT <br />2. <br />1/2" EXT. GRADE PLYWOOD SHEATHING I <br />4\ _ 3. <br />ROOF TRUSSES @ 24" OC MAX <br />4. <br />R-30 BLOWN INSULATION <br />5. <br />(1) LAYER 5/81' GYPSUM BOARD <br />TYP. @ CLUBHOUSE NON -CONDITIONED <br />I <br />SPACES <br />RC-3 <br />NON RATED <br />-- <br />1. <br />30 YEAR ARCHITECTURAL FIBERGLASS/ASPHALT SHINGLES ON NO.30 FELT <br />2. <br />1/2" EXT. GRADE PLYWOOD SHEATHING <br />3. <br />ROOF TRUSSES @ 24" OC MAX <br />4. <br />i i <br />(1) LAYER 5/8" EXT. GRADE GYPSUM BOARD <br />I <br />TYP. @ RATED BREEZEWAY & NON -CONDITIONED <br />SPACES <br />RC-4 <br />1. ROOF CLADDING PER ELEVATION: (OPTION A OR B) <br />1 HOUR <br />1.A. <br />30 YEAR ARCHITECTURAL FIBERGLASS / ASPHALT SHINGLES ON NO.30 FELT <br />RATED <br />1.6. <br />STANDING SEAM METAL ROOF OVER SPECIFIED UNDERLAYMENT <br />2. 1/2" <br />EXT. GRADE PLYWOOD SHEATHING <br />UNDERWRITER'S <br />3. ROOF TRUSSES @ 24" OC MAX <br />LABORATORY <br />4. RESILIENT CHANNELS @ 12" OC MAX, PERPENDICULAR TO TRUSSES <br />DESIGN P522 <br />5. (1) LAYER 5/8" FIRE -RATED EXT. GRADE GYPSUM BOARD <br />i <br />TYP. @ ELEVATOR HOISTWAY LID <br />RC-5 <br />- 1. <br />TPO MEMBRANE ! <br />2 HOUR <br />- -- 2. <br />R30 POLYSOCYANURATE INSULATION <br />RATED <br />3. <br />NOMINAL 3/4" PLYWOOD SHEATHING <br />4. <br />2X8 WOOD JOISTS @ 24" OC MAX <br />5. <br />(3) LAYERS 5/8" FIRE -RATED GYPSUM BOARD <br />GYPSUM ASSOCIATION <br />6. <br />HAT CHANNELS @ MAX. 24" OC, PERPENDICULAR TO JOISTS <br />(GA# FC5725) <br />7. <br />(1) LAYER 5/8" FIRE -RATED EXT. GRADE GYPSUM BOARD <br />TYP. @STAIR LID <br /><9> <br />1. <br />TPO MEMBRANE <br />2 HOUR <br />2. <br />R30 POLYSOCYANURATE INSULATION <br />RATED <br />3. <br />NOMINAL 3/4" PLYWOOD SHEATHING <br />4. <br />2X8 WOOD JOISTS @ 24 OC MAX <br />- 5. <br />(3) LAYERS 5/8" FIRE -RATED GYPSUM BOARD <br />GYPSUM ASSOCIATION <br />HAT CHANNELS @ MAX. 24" OC, PERPENDICULAR TO JOISTS <br />(GA# FC5725) <br />7. <br />(1) LAYER 5/8" FIRE -RATED EXT. GRADE GYPSUM BOARD <br />TYP. @ STAIR ENCLOSURE LOW ROOFS <br />RC-7 <br />1. <br />/ <br />I <br />STANDING STEAM METAL ROOF OVER SPECIFIED UNDERLAYMENT <br />2 HOUR <br />2. <br />314" EXT. GRADE PLYWOOD SHEATHING <br />RATED <br />3. <br />ROOF TRUSSES @ 24" OC MAX <br />- 4. <br />R-30 BLOWN INSULATION <br />GYPSUM <br />5. <br />(3) LAYERS 5/8" FIRE RATED GYPSUM BOARD <br />ASSOCIATION <br />6. <br />HAT CHANNELS @ 24" OC MAX, PERPENDICULAR TO TRUSSES <br />(GA# RC2751) <br />7. <br />(1) LAYER 5/8" FIRE RATED GYPSUM BOARD <br />ASSEMBLY NOTES <br />A THE INDICATED UL ASSEMBLIES AND OTHER SPECIFIED FIRE RATED DESIGNS ARE THE "BASIS OF DESIGN" FOR FIRE SAFETY, SOUND <br />TRANSMISSION, MATERIAL SELECTION, ETC. THE CONTRACTOR MAY SUBMIT ALTERNATE ASSEMBLIES FOR REVIEW AND APPROVAL BY THE <br />ARCHITECT, PRIOR TO CONSTRUCTION, TO BE USED IN PLACE OF THE ASSEMBLIES INDICATED ON THESE CONSTRUCTION DOCUMENTS. <br />THE CONTRACTOR SHALL PROVIDE ALL MATERIALS AND EQUIPMENT AS INDICATED IN THE ASSEMBLY AND/OR WITHIN THE SYSTEM THAT IS <br />PART OF THE ASSEMBLY. NO SUBSTITUTION OF MATERIALS OR ADDITIONAL MATERIALS WILL BE ACCEPTED AND WHICH ARE NOT ALLOWED <br />PER THE ASSEMBLY. APPROVAL OF THE ASSEMBLY BY THE ARCHITECT DOES NOT RELEASE THE CONTRACTOR FROM THE RESPONSIBILITY <br />OF MEETING ALL APPLICABLE BUILDING CODES AND REGULATIONS. THE CONTRACTOR IS ALSO RESPONSIBLE FOR SUBMITTING <br />DOCUMENTATION OF THE PROPOSED ALTERNATE ASSEMBLY TO THE AHJ FOR APPROVAL PRIOR TO CONSTRUCTION. <br />B CONTRACTOR TO PROVIDE CURRENT UL LISTED PENETRATION FIRESTOP SYSTEM DESIGNS AND INSTALLATIONS COMPATIBLE FOR THE <br />RATED ASSEMBLIES BEING PENETRATED. SUBMIT COPIES OF UL LISTED PENETRATION SYSTEMS TO ARCHITECT FOR REVIEW AND <br />APPROVAL, PRIOR TO CONSTRUCTION. CONTRACTOR IS ALSO RESPONSIBLE FOR SUBMITTING DOCUMENTATION OF PROPOSED <br />PENETRATION FIRESTOP SYSTEM TO THE AHJ FOR APPROVAL PRIOR TO CONSTRUCTION. <br />C METALLIC PENETRANTS THROUGH HORIZONTAL ASSEMBLIES WITH T-RATINGS OF <1 HOUR SHALL OCCUR WITHIN WALLS OR CONCEALED <br />SIGNIFICANT REVISIONS HAVE BEEN MADE TO THIS SHE <br />DUE TO THE CHANGE TO A WOOD FRAME STRUCTURE <br />AND ENCLOSING THE CORRIDORS <br />U <br />z <br />INTERIOR DESIGN, INC. <br />PLANNING I ARCHrrECMFtE <br />745 orienta avenue, suite 1121 <br />altamonte springs, fi 32701 <br />phone: 407.830.1400 <br />fax: 407.830.4143 <br />AA0002731 <br />www.forumarchitecture.com <br />n®a flan <br />nn ono <br />00 <br />BENEFICIAL <br />COMMUNITIES <br />3550 S. Tamiami Trail Suite 301 Sarasota, FL 34239 <br />Zephyrhills, FL <br />EDITED BY: KG <br />PROJECT NO. 14-2984 <br />Apartments <br />Construction Assemblies <br />
The URL can be used to link to this page
Your browser does not support the video tag.