Laserfiche WebLink
I I I - --- —) <br />I <br />11 <br />(2) TYP. <br />25' -011 <br />1 1L 1 f�11Y1 1 I"-1 f�11Y1 <br />r OVERHANGS OVERHANGS <br />5 1 —511 19' —411 <br />RSH <br />ENGINEERED ROOF PER ASCE 7-16 ROOF DESIGN ALLOWABLE COMPONENTS AND <br />CLADDING WIND PRESSURES AND SUCTIONS FOR MEAN ROOF HEIGHT 5 25 ft <br />VIND SPEED (ULTIMATE) <br />140.0 MPH <br />VIND SPEED (ALLOWABLE) <br />108.4 MPH <br />!XPOSURE CATEGORY <br />C <br />EFFECTIVE <br />WIND PRESSURE AND SUCTION (PSF) <br />HIP ROOF >20 TO 45 DEG. <br />WIND AREA <br />(+) VALUE DENOTES PRESSURE <br />[4:12]-[12:12] <br />(SQ FEET) <br />(-) VALUE DENOTES SUCTION <br />a=oft <br />/ <br />\�O <br />AREA <br />ROOF <br />1 <br />2e <br />2n <br />I 2r <br />1 3 <br />3e <br />f 3rB <br />HIP <br />-35.94 <br />-49.57 <br />-49.57 <br />-49.57 <br />10 <br />GABLE <br />-38.22 <br />-38.22 <br />-60.99 <br />-60.99 <br />-60.99ROOF <br />NAILING NAILING SCHEDULE/ NAILING ZONES (SHINGLE AND TILE): <br />� <br />ZONE 1: ASTM F1667 RSRS-01 (8d) NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD <br />ZONE 2e, 2n, 2r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />I r <br />Q <br />ZONE 3, 3e, 3r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />I I <br />ROOF SHEATHING: <br />I(D I l (D l <br />SHINGLE: Y16" EXP. 1 e%) or 1% ' EXP. 1 (32/16) <br />I I I <br />TILE: 1%2" EXP. 1 e3116) <br />I r <br />I I I <br />NOTE: <br />1. PER CODE ASTM F1667 RSRS-01 REFERENCE TO 8d (2 Y/8" x 0.113") NAILS <br />I I I I <br />z I-- <br />2. WHERE THE SHEATHING THICKNESS IS GREATER THAN tV32", SHEATHING SHALL BE FASTENED <br />") <br />, <br />WITH ASTM F1667 RSRS-03 10d (2'/z" x 0.131 NAILS OR ASTM F1667 RSRS-04 (3" x .120") NAILS <br />a=oft <br />3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 #2 SYP OUTLOOKER GABLE <br />ROOF > 20 TO 45 DEG. <br />RAFTER W/ BLOCKING @ 16" O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING <br />[4:12]-[12:12] <br />@ 16" O.0 FIRST 4 BAYS WITH (2) 12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS <br />W/ BLOCKING PER NAILING SCHEDULE. <br />UPLIFT CONNECTION CROSS-REFERENCE <br />MARK <br />SIMPSON STRONG TIE <br />USP MANUFACTURING, INC. <br />Q <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />SYP <br />SPF <br />SYP <br />SPF <br />A <br />META12 <br />1420 <br />9 -1 Od x 1 1/2" <br />HTA20 <br />1870 <br />1585 <br />10 -10d x 1 1/2" <br />A (2) <br />(2)META12 <br />1875 (1)PLY <br />1795 (2)PLY <br />9 - 10d x 1 1/2" <br />B <br />HETA16 <br />1810 <br />9 -10d x 1 1/2" <br />HTA16 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />C <br />H2,5A <br />565 <br />535 <br />10 - 8d <br />RT7A <br />585 <br />515 <br />10 - 8d x 1 1/2" <br />D <br />H3 <br />400 <br />320 <br />8-8d <br />RT3 <br />345 <br />305 <br />8 - 8d x 1 1/2" <br />E <br />META20 <br />1450 <br />7 -10d x 1 1/2" <br />HTA20-18 <br />1625 <br />1400 <br />10 -10d x 1 1/2" <br />F <br />HHETA20 <br />2120 <br />10 - 10d x 1 1/2" <br />HTTA20 <br />2375 <br />11 - 10d x 1 1/2" <br />G <br />H10A <br />1040 <br />1015 <br />18 - 1Od x 1 1/2" <br />RT16A <br />1020 <br />1160 <br />9 - 10d x 1 1/2"& 8-10d <br />H <br />FGTR <br />4725 <br />3400 <br />w/ (18) 1/4" x 3" SDS <br />WOOD SCREWS AND (2) <br />1/2" x 5" TITEN HD ACHOR <br />BOLTS <br />RFUS <br />7100 <br />--- <br />w/ (12) WS3 WOOD <br />SCREWS AND (4) 3/4" x 6" <br />WEDGE -BOLTS <br />J <br />HTT5 <br />4350 <br />3740 <br />5/8" ANCH. / (26)10dx1-112" <br />HTT5 <br />5795 <br />518" ANCH. /(26)10d x1-1/2 <br />K <br />HD3B * <br />3130 <br />3050 <br />5/8" DIA. BOLTS <br />TDX2-TZ <br />3295 <br />— <br />2 - 518" DIA. BOLTS <br />L <br />VGT R/L <br />2225 <br />1600 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />X 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />M <br />VGT - F <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />x 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />N <br />LUS26 <br />1165/1060 ** <br />1005/915 ** <br />8 - 10d x 3" <br />JUS26 <br />1000/1080** <br />- - <br />8 -10d <br />P <br />HUS26 <br />1320/3235 ** <br />1335/2820 *" <br />20 - 16d x 3 1/2" <br />HUS26 <br />2035/3400 <br />-- <br />(20)16d x 3-1/2" <br />Q <br />HUS28 <br />1760/4095 ** <br />1720/3125 *' <br />30 - 16d x 3 1/2" <br />HUS28 <br />2950/5090 <br />-- <br />30d -16d x 3-1/2" <br />R <br />MTS12 <br />990 <br />860 <br />14 - 10d x 1 1/2" <br />MTW12 <br />1195 <br />1005 <br />14-10d x 1-1/2" <br />S <br />VGT - M <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND (1) <br />5/8" ATR EPDXIED w/ <br />SIMPSON SET w/ 12" MIN. <br />EMBEDMENT. <br />T <br />(2) LGT3 <br />6570-M 6960-F <br />4730-M 5010-F <br />w/ (24) 1 /4" x 3" SDS <br />SCREWS & (8) 3/8" x 5" <br />TITEN HD (2 PLY) OR (52) <br />16D SINKERS FOR FRAME <br />U <br />MGT <br />3965 <br />3330 <br />22 -10d x (1) 5/8" ATR w/ 12" <br />EMBED w/ SIMPSON "SET" <br />EPDXY <br />MUGT15 <br />4175 <br />22 -1 Od x (1) 5/8" ATR w/ 12" <br />EMBED w/ USP CIA-7000C <br />EPDXY <br />V <br />(2) LGT2 <br />4060-M 3770-F <br />3500-M 3240-F <br />w/ (32 D INKER <br />(14) 1/4" x 2 1/4" TITENS <br />(2 PLY) OR (28) 16D <br />SINKERS FOR FRAME <br />LUGT2 <br />3100-M 4520-F <br />3100-M 3800-F <br />w/ (32) 16D SINKERS & <br />(10) 1/4" x 3" WEDGE- <br />BOLTS (2-PLY) OR (32) 16 <br />SINKERS FOR FRAME <br />"X" <br />HTS 20 <br />1310 <br />1245 <br />24-10d x 1 1/2" <br />HTW20 <br />1530 <br />1285 <br />24-1 Od x 1 1/2" <br />SP1 <br />555 <br />5 <br />1 10 - 10d <br />SPT22 <br />735 <br />8 -10d <br />SP2 <br />1010 <br />605 <br />12-10d <br />SPT24 <br />1090 <br />12-10d <br />HCP2 <br />590 <br />555 <br />12-1 Old x 1 1/2" <br />HHCP2 <br />1 680 <br />1 570 <br />1 (20)10d x 1-1/2" <br />* MINIMUM 3" MEMBER <br />** REACTIONS ARE FOR ROOF LOADS ONLY <br />*** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. <br />ALL EPDXY ANCHORS SHALL USE SIMPSON "SET" OR USP CIA-7000C (SEE MANUFACTURES SPECS) <br />NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. REVISED 12-02-20 <br />LOADS -- ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. <br />FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" <br />OC FOR CARPET AREA'S <br />DROP HIP DETAIL <br />2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS <br />148-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6") <br />*FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING <br />POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) <br />TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT (**). <br />INTERSECTING POINT TO BE FASTENED WITH 2. 16d COMMON NAILS OR 0.128" x 3" GUN <br />NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH <br />THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) <br />IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (8) 2x4 SO. PINE #2 OR #2 PT. STICK <br />LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED <br />FOR HIP PLANING TRUSSES. R1 <br />STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS <br />INTERSECTIONS. SPLICING <br />TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK <br />FRAMING SPLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE 6-0"ON A HORIZONTAL PROJECTION. <br />NOTE: SEE SHEET D1 FOR ROOF FRAMING DETAILS <br />1 (2) -12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM <br />BELOW. TYP. AT INTERIOR BEARING U.N.O. <br />(A) <br />OR 2 PLY <br />;ARRIER <br />SEE SHEET D1 FOR <br />ROOF FRAMING <br />DETAILS <br />ROOF FRAMING PLAN — ELEV—B <br />SCALE: X"=V-0" <br />012 <br />N <br />O <br />•� N <br />as <br />RS « N <br />W <br />.!' u AID <br />m �Q <br />a Ix <br />N C6 <br />c E <br />Witte <br />O Ai Ike, <br />' <br />F' C` - V ro <br />Sao <br />:.� o <br />4 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />in <br />W <br />0 E <br />g $ <br />r <br />0 , O C 00 <br />(a NNn0 i6 <br />ni ajMv J <br />Q u u LL LL W <br />1133 <br />Z <br />� <br />o <br />W�mW <br />Z Z - <br />IL <br />ZN U <br />Oy <br />W ❑❑ <br />V M <br />z N <br />Z <br />z <br />Q <br />d � <br />U) <br />I ^ Np <br />z p <br />0U1 <br />Ur s` <br />(� w <br />p a <br />U W <br />� <br />O LU <br />In c <br />(V) 1=— 3 <br />' w � <br />= t <br />s <br />Q 0 <br />� <br />N <br />co <br />co <br />J <br />z <br />Z <br />co <br />CM <br />5o <br />¢ <br />Q <br />LJL <br />a O <br />zo <br />w <br />g <br />>� <br />Zo <br />z <br />0 <br />° <br />z <br />ccaa U <br />� h <br />O ro <br />o <br />XOG <br />a��� <br />w� <br />U0 <br />=O U <br />Ww <br />N <br />d >_ <br />0 <br />ao <br />�� <br />mf <br />to C <br />° E <br />Z <br />z <br />� J <br />3 <br />�� <br />g� <br />¢w <br />U <br />a <br />�w <br />W <br />T 3 <br />�o <br />fit= <br />J0. <br />o <br />w0 <br />st <br />Z Q <br />a <br />0, <br />U 3 <br />,o O <br />>M <br />0 <br />N <br />(0 r , <br />r <br />:3 O <br />Q <br />O <br />U) 2 <br />.2 <br />N <br />c <br />U <br />CD <br />co <br />C7 N <br />M <br />N O <br />LO <br />N.� <br />Q INt N <br />r <br />ui <br />CM N <br />Nto <br />o <br />z <br />Li r.. <br />It— <br />L <br />c <br />c <br />m <br />a <br />v ai <br />U 3 Q <br />JOB <br />NO: 22-12361 <br />SCALE : AS NOTED <br />SHEET NO. <br />6.2 <br />