My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36442 Garden Wall Way
Zephyrhills
>
Building Department
>
Building Plans
>
36442 Garden Wall Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 4:37:47 PM
Creation date
2/18/2025 4:12:58 PM
Metadata
Fields
Template:
Building Plans
Street #
36442
Location
Garden Wall Way
Contractor
Lennar Home
Building Plans - Permit #
5693
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
__ _ <br />TYP. @ 1 <br />CORNERS p2 <br />0 <br />80 <br />0 <br />F, <br />Cl) <br />00 <br />LO <br />13-0" 1 12'-0" <br />2 <br />FT3GE D2 <br />N <br />0 <br />A @ 24" <br />O.C. MIN. <br />CE <br />CE <br />CE <br />S6 <br />CE <br />TYP. @ 2 STORY. <br />SEE JJ/S6 @ <br />STEMWALL <br />CE <br />FT7G <br />1 <br />L1 <br />0 <br />iv <br />c0 <br />FT6 <br />TYP. 1 E <br />LO <br />BRG. WAL <br />0 <br />0 <br />D <br />r <br />FT8GCR <br />FT11 LL. <br />FT13GE <br />BRG. WALL <br />CS <br />5M <br />J <br />S6 <br />TYP. @ 2 STORY. <br />SEE JJ/S6 @ <br />STEMWALL <br />H35 <br />A (2) <br />A <br />TYP. <br />U.N.O. <br />ao <br />22 <br />A (2) FT9 D1 <br />CJ38 <br />CJ 16 <br />_ <br />9 <br />D1 <br />D1 <br />do <br />FG3 <br />D1 <br />M <br />10 <br />m m <br />M <br />U C� <br />5'-0" <br />Cl) <br />m <br />A <br />S3 <br />TYP. @ 1 STORY <br />(SEE AA/S3 FOR <br />STEM OPT.) <br />5'-8" <br />B4GE <br />ENGINEERED ROOF PER ASCE 7-16 ROOF DESIGN ALLOWABLE COMPONENTS AND <br />RSH CLADDING WIND PRESSURES AND SUCTIONS FOR MEAN ROOF HEIGHT 5 25 ft <br />WIND SPEED (ULTIMATE) 140.0 MPH <br />WIND SPEED (ALLOWABLE) 108.4 MPH <br />EXPOSURE CATEGORY C <br />EFFECTIVE WIND PRESSURE AND SUCTION (PSF) HIP ROOF >20 TO 45 DEG. <br />WIND AREA (+) VALUE DENOTES PRESSURE <br />(SQ FEET) (-) VALUE DENOTES SUCTION [4:12]-[12:12] <br />a=4ft <br />AREA ROOF 1 2e I 2n 2r 3 3e 3r <br />10 HIP -35.94 -49.57 -49.57 -49.57 1 <br />GABLE -38.22 38.22 60.99 -60.99 -60.99— <br />ROOF NAILING SCHEDULE/ NAILING ZONES (SHINGLE AND TILE): � `\r O �/ <br />ZONE 1: ASTM F1667 RSRS-01 (8d) NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD <br />ZONE 2e, 2n, 2r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ZONE 3, 3e, 3r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD IF9i j I I <br />ROOF SHEATHING: 1 O 1 I O <br />SHINGLE: 3/16"EXP. 1 (2%6) or1%2" EXP. 1 (3�6) 1 I I i <br />1 10 <br />TILE: 1Y32" EXP. 1 N/1s) I I r <br />NOTE: I I I 1 <br />1. PER CODE ASTM F1667 RSRS-01 REFERENCE TO 8d (2 %" x 0.113") NAILS z <br />J r r <br />2. WHERE THE SHEATHING THICKNESS IS GREATER THAN 1Y32', SHEATHING SHALL BE FASTENED <br />WITH ASTM F1667 RSRS-03 10d (2%" x 0.131 ") NAILS OR ASTM F1667 RSRS-04 (3" x .120") NAILS a=oft <br />3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 #2 SYP OUTLOOKER GABLE ROOF > 20 TO 45 DEG. <br />RAFTER W/ BLOCKING @ 16" O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING [4:12]-[12:12] <br />@ 16" O.0 FIRST 4 BAYS WITH (2) 12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS <br />W/ BLOCKING PER NAILING SCHEDULE. <br />2 ROWS 8d @ 6" O.C. NOTE: THE SHEAR WALL FRAMING DOES NOT EXTEND <br />8d NAILS @ 6" O.C. ABOVE THE ROOF, SUB -ROOF, OR FLOOR SHEATHING <br />TO BLOCKING <br />(2) 12d NAILS TO ROOF OR FLOOR <br />BLOCKING EACH SHEATHING <br />END <br />2X4 BLOCKING AT (2) SYP#2 TOP PLATE <br />EA. ROOF PANEL <br />JOINT AT 48" <br />MAX LSTA30 EACH SIDE <br />TRUSSES —/ EACH END OF <br />WALL <br />2x4 SPF STUDS — <br />@ 16" O.C. WALL <br />SET BACK 2" PER <br />DETAIL C/S3 <br />SEE C/S3 FOR <br />ADD'L INFO. <br />1<7 ,7 7-7 •: _ ; xR�'` � SEE PLAN FOR DIM. <br />SEE FND. PLAN <br />FOR FOOTING ° <br />SPECS. <br />INTERIOR SHEARWALL @ TRUSSES <br />STEP-DOWN, WALL TO TRUSS 35 <br />SCALE: 1/2" = 1'-0" <br />UPLIFT CONNECTION CROSS-REFERENCE <br />MARK <br />SIMPSON STRONG TIE <br />USP MANUFACTURING, INC. <br />Q <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />SYP <br />SPF <br />SYP <br />SPF <br />A <br />META12 <br />1420 <br />9 -10d x 1 1/2" <br />HTA20 <br />1870 <br />1585 <br />10 -10d x 1 1/2" <br />A (2) <br />(2)META12 <br />1875 (1)PLY <br />1795 (2)PLY <br />9 - 10d x 1 1/2" <br />B <br />HETA16 <br />1810 <br />9 - 10d x 1 1/2" <br />HTA16 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />C <br />H2.5A <br />565 <br />535 <br />10 - 8d <br />RT7A <br />585 <br />515 <br />10 - 8d x 1 112" <br />D <br />H3 <br />400 <br />320 <br />8-8d <br />RT3 <br />345 <br />305 <br />8 - 8d x 1 1/2" <br />E <br />META20 <br />1450 <br />7 -10d x 1 1/2" <br />HTA20-18 <br />1625 <br />1400 <br />10 - 10d x 1 1/2" <br />F <br />HHETA20 <br />2120 <br />10 -10d x 1 1/2" <br />HTTA20 <br />2375 <br />11 - 10d x 1 1/2" <br />G <br />H10A <br />1040 <br />1015 <br />18 - 10d x 1 1/2" <br />RT16A <br />1020 <br />1160 <br />9 - 10d x 1 1/2"& 8-10d <br />H <br />FGTR <br />4725 <br />3400 <br />w! (18) 1/4" x 3"SDS <br />WOOD SCREWS AND (2) <br />1/2" x 5" TITEN HD ACHOR <br />BOLTS <br />RFUS <br />7100 <br />--- <br />w/ (12) WS3 WOOD <br />SCREWS AND (4) 3/4" x 6" <br />WEDGE -BOLTS <br />J <br />HTT5 <br />4350 <br />3740 <br />5/8" ANCH. / (26) 10dx1-1/2" <br />HTT5 <br />5795 <br />5/8" ANCH. /(26) 10d x1-1/2 <br />K <br />HD3B * <br />3130 <br />3050 <br />5/8" DIA. BOLTS <br />TDX2-TZ <br />3295 <br />--- <br />2 - 5/8" DIA. BOLTS <br />L <br />VGT R/L <br />2225 <br />1600 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />X 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />M <br />VGT - F <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />x 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />N <br />LUS26 <br />1165/1060 ** <br />1005/915 ** <br />8 -10d x 3" <br />JUS26 <br />1000/1080** <br />--- <br />8 -10d <br />P <br />HUS26 <br />1320/3235 ** <br />1335/2820 ** <br />20 - 16d x 3 1/2" <br />HUS26 <br />2035/3400 <br />-- <br />(20)16d x 3-1/2" <br />Q <br />HUS28 <br />1760/4095 ** <br />1720/3125 ** <br />30 - 16d x 3 1/2" <br />HUS28 <br />2950/5090 <br />- <br />30d -16d x 3-1/2" <br />R <br />MTS12 <br />990 <br />860 <br />14 - 10d x 1 1!2" <br />MTW12 <br />1195 <br />1005 <br />14-10d x <br />S <br />VGT - M <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SDS <br />WOOD SCREWS AND (1) <br />5/8" ATR EPDXIED w/ <br />SIMPSON SET w/ 12" MIN. <br />EMBEDMENT. <br />T <br />(2) LGT3 <br />6570-M 6960-F <br />4730-M 5010-F <br />w/ (24) 1/4" x 3" SDS <br />SCREWS & (8) 3/8" x 5" <br />TITEN HD (2 PLY) OR (52) <br />16D SINKERS FOR FRAME <br />U <br />MGT <br />3965 <br />3330 <br />22 -10d x (1) 5/8" ATR w/ 12" <br />EMBED w/ SIMPSON "SET" <br />EPDXY <br />MUGT15 <br />4175 <br />22 -10d x (1) 5/8" ATR w/ 12" <br />EMBED w/ USP CIA-7000C <br />EPDXY <br />V <br />(2) LGT2 <br />4060-M 3770-F <br />3500-M 3240-F <br />w/ (32) 16D SINKERS & <br />(14) 1/4" x 2 1/4" TITENS <br />(2 PLY) OR (28) 16D <br />SINKERS FOR FRAME <br />LUGT2 <br />3100-M 4520-F <br />3100-M 3800-F <br />w/ (32) 16D SINKERS & <br />(10) 1/4" x 3" WEDGE- <br />BOLTS (2-PLY) OR (32) 16 <br />SINKERS FOR FRAME <br />"X" HTS 20 1310 1245 24-10d x 1 1/2" HTW20 1530 1285 24-10d x 1 1/2" <br />SP1 555 535 10 - 10d SPT22 735 8 - 10d <br />SP2 1010 605 12-10d SPT24 1090 12-10d <br />HCP2 590 555 1 12-10d x 1 1/2" HHCP2 680 570 (20)10d x 1-1/2" <br />* MINIMUM 3" MEMBER <br />** REACTIONS ARE FOR ROOF LOADS ONLY <br />*** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. <br />ALL EPDXY ANCHORS SHALL USE SIMPSON "SET" OR USP CIA-7000C (SEE MANUFACTURES SPECS) <br />NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. REVISED 12-02-20 <br />LOADS — ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. <br />FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" <br />OC FOR CARPET AREA'S <br />DROP HIP DETAIL <br />2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS <br />1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6") <br />'FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING <br />POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) <br />TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT ("). <br />INTERSECTING POINT TO BE FASTENED WITH 2 -16d COMMON NAILS OR 0.128" x 3" GUN <br />NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH <br />THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) <br />IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK <br />LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED <br />FOR HIP PLANING TRUSSES. R1 <br />STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS 1 0 <br />INTERSECTIONS. SPLICING <br />TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK <br />FRAMING SPLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE 5'-0" ON A HORIZONTAL PROJECTION. <br />NOTE: SEE SHEET D1 FOR ROOF FRAMING DETAILS <br />1 (2) -12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM <br />BELOW. TYP. AT INTERIOR BEARING U.N.O. <br />(A) <br />OR 2 PLY <br />BARRIER <br />x CONT LEDGER <br />SEE SHEET D1 FOR <br />ROOF FRAMING <br />DETAILS <br />FLOOR FRAMING PLAN — ELEV—B_ <br />SCALE: Y4'=1'-0" <br />'I <br />c <br />Z <br />•o <br />Q <br />1 <br />a, <br />a <br />C3 � o <br />• a� o <br />N <br />c�n- <br />ets o >_ <br />In N L <br />N O J <br />Sj• co <br />E <br />d LJ <br />� 3 � <br />c o <br />cc <br />= T <br />N Q- <br />c E <br />� o <br />a U <br />u�ttlfr�,,�, <br />0K Al ,��• <br />Q <br />6�12 <br />l <br />ou <br />NP <br />r �lrjtrCi)1.4�1 <br />.'-_ <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />0 <br />H <br />E <br />o $8 <br />U <br />0 <br />N o1 <br />C' <br />N M1 <br />Co i 00 <br />M <br />ycov i <br />Q <br />C -j LL W <br />LL L SS 6. <br />1 3z.M.Cg <br />J W <br />'L {Z^Y� <br />f O <br />Ag°'°' <br />Z <br />ILW <br />IL <br />m <br />N r- Z ¢ J <br />Z <br />OU U <br />W <br />❑❑ <br />Z w $ <br />z � � <br />z <br />Q <br />cl- <br />N <br />z `° <br />X+-j <br />U- <br />cn <br />LU <br />U <br />O <br />w i3 <br />V) <br />rz Y <br />' <br />w <br />E <br />L <br />z <br />_ 2 d) <br />U o <br />Q .0 o <br />• <br />o <br />C <br />w <br />M <br />Z <br />Q <br />U- <br />0 <br />E <br />zffi <br />Wo <br />s <br />s <br />> <br />z® <br />oa <br />N U <br />5� <br />0= <br />?O <br />Wa <br />z <br />g E <br />N � <br />g <br />o <br />Wz <br />Cl)C <br />C <br />U <br />O <br />0 <br />oLL <br />z <br />> <br />z <br />J <br />az <br />z <br />to <br />CL <br />d <br />�9 <br />WNW <br />az <br />W <br />U <br />Nz <br />= k <br />fir <br />O <br />O <br /><p <br />V <br />w <br />az <br />Z Q <br />az <br />O_ <br />U 'S <br />OC <br />N <br />> M <br />LL <br />O <br />ui <br />rn <br />m <br />m <br />0 <br />N <br />(o r.--. <br />> <br />T <br />:3 O <br />3 <br />^ <br />CO <br />O <br />(n m <br />N <br />LO <br />.� <br />04 O <br />LO <br />N <br />Q <br />� 04 <br />E <br />c (V <br />M N <br />z <br />z <br />E T <br />y <br />`m <br />c <br />IL <br />E <br />U -j <br />¢ 0 <br />JOB <br />NO : <br />22-12361 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />6.1 <br />1 M <br />
The URL can be used to link to this page
Your browser does not support the video tag.