ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANELCENTER <br />—OP #14 to lights & outlets <br />NEMA 1 10 #12 to appliances and GFI <br />150 AMP/ <br />200 AMP 0 #10 to WH <br />10 #8 to Range <br />#6 to HVAC <br />R <br />50=2/0 <br />J <br />200=4I0 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND <br />Di <br />SERVICE BY POWER CO. <br />INTERSYSTEM <br />Bare Cu Ground <br />BONDING <br />UNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type Installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined In UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501,17.1.1 through R4501.17,1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be Included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FTT <br />DUPLEX OUTLET ABOVE COUNTER <br />PE5W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />& <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />© <br />RECESSED LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />�-� <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />tO <br />EXHAUST FAN/LIGHT COMBINATION <br />® <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />�BP <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />t1 <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />v C.r\lr t 1VIG 1 GR <br />LOCATION WITH <br />BUILDER <br />rl� <br />�ITc <br />U To �E <br />�� P <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />ENTRY <br />AS <br />SECS <br />4 <br />41• <br />FIRST FLOOR ELECTRICAL PLAN - ELEV-Al <br />SCALE: /4"=V-0" <br />c■'� i <br />CV <br />C\f <br />+r— <br />C <br />l� <br />d. , <br />Y W <br />Cr M Cj Cy <br />omac <br />C LL Q <br />N cc ® �. <br />N p � <br />at <br />rl- <br />cac cc <br />m � <br />a u a�a <br />o <br />d U <br />m <br />C`4 <br />CV <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and spedfications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural <br />engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />I W <br />0 <br />r, o N ti <br />C/ l— 'Z <br />Q <br />LL <br />ou_L ill <br />Q. <br />Z <br />— 0) <br />m <br />tW <br />`�. <br />0 <br />Z <br />T m w <br />� M ¢ r <br />(� <br />a Q J <br />o� <br />z <br />W <br />00h?�' <br />❑ C7 <br />CD cmi <br />O <br />J <br />� <br />u1 <br />- N <br />M <br />a <br />CDll�D <br />_O <br />tL <br />4—' <br />cn <br />V <br />9 — <br />O0 <br />LU <br />�cn <br />to, <br />oo <br />Q N <br />14 <br />Co <br />w <br />Z <br />M <br />J <br />6L <br />Zr <br />O� <br />W o <br />'Z <br />yN <br />4 <br />o <br />Q <br />E U <br />wa <br />q � <br />2 <br />o <br />oa <br />w <br />t— rci <br />�0 <br />b C <br />o <br />z' <br />01 <br />I— <br />wo <br />Z7. <br />RH <br />Cn <br />p <br />�Y <br />m0 <br />o& <br />Z <br />N <br />�� <br />a z <br />W <br />��$iY] <br />0 M <br />o <br />z <br />50 <br />W <br />VJ <br />A 7 <br />7 <br />LL <br />a <br />m W <br />^ <br />CY] <br />� a <br />�LL <br />� Lx: <br />61 <br />o <br />�� <br />615 <br />�o <br />c <br />ol¢ <br />4 t r <br />U-) <br />."i <br />L0 <br />rn <br />m <br />co <br />0 <br />I--- <br />(o <br />� MO <br />M <br />Ile <br />r <br />U) s <br />CD(1) <br />N <br />mLO <br />rn <br />� <br />C37 <br />co � CV) <br />Cn <br />� <br />M <br />L O <br />000 0 <br />CV <br />N <br />'� N <br />r <br />E <br />c (0 �/'� <br />M <br />�° <br />t15 <br />z <br />N <br />yj r <br />C <br />c <br />4 <br />qE <br />CJ r <br />Q p <br />.J <br />JOB <br />NO: <br />23-00520 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.1 <br />