Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED, LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES, <br />150A/200A INDOOR <br />NEMA 1 <br />150 AMP/ <br />200 AMP <br />4 to lights & outlets <br />2 to appliances and GFI <br />D to WH <br />to Range <br />to HVAC <br />METER II <br />�J <br />150=2/0 <br />200,4/0 In 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND <br />Disconnect <br />SERVICE BY POWER CO. <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250,52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES: <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017). by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7, Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1,2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11, In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501,17.1.14, <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />PE�FW.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />fLph <br />� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />(b <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />1-0 <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />---- `, <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />116) <br />EXHAUSTFAN <br />;,, <br />EXHAUST FAN/LIGHT COMBINATION <br />® <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />H <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />Sq <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />N <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD, HT, & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />r----------------.--------._-----------,_-------- <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />-------.----------_ --- —_----------_--- ---------- <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />__j <br />SECOND FLOOR ELECTRICAL PLAN - ELEV-Al <br />SCALE: %4"=1'-0" <br />eri <br />N <br />p <br />N <br />0 <br />wZ. U-J! <br />of <br />o <br />ci =r. o <br />GV <br />�t `O- <br />ao = — <br />N y 0 <br />c <br />d <br />CD C <br />a, <br />itis �y m s" <br />l0 <br />y CL <br />coo E <br />0 <br />cl- U <br />r"> <br />cV <br />ba <br />c_y <br />CV <br />0 <br />To the best of the Englneer's knowledge, Information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal Is only for <br />the structural <br />engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />Q o � <br />0 co <br />Clio <br />.-d-LLW <br />J LL LL , o <br />d Y <br />ZCA <br />Z <br />1,03 <br />Wj (eN (1) � o <br />82r- <br />W m <br />Z N Ma Q J-- <br />R 0 <br />ZIL o� <br />W ❑❑ <br />CD M �_ <br />N <br /><c � <br />--- N <br />V) 2: <br />0 <br />•U <br />W S <br />V) � <br />= <br />�n <br />o <br />U_ <br />tp <br />Cl <br />U <br />0 <br />W <br />~= <br />Z <br />D: <br />UO <br />ICU <br />E <br />O <br />U <br />� U <br />Z <br />o <br />CID <br />8 <br />'2 <br />N. C <br />n <br />� <br />tiG <br />m2 <br />p ¢ <br />ZJ <br />m <br />�+ m <br />4 C <br /><4 <br />�j�j <br />V] <br />6N' <br />5. <br />W <br />nl <br />0 <br />O <br />>Lo <br />LO <br />LCL <br />rn <br />m <br />co <br />CT <br />0 <br />,— <br />�e <br />W Q <br />N <br />m <br />00 <br />L O <br />T <br />, j Vi <br />0) <br />Q) <br />00 <br />In <br />C'V <br />vM'` N <br />Q a <br />r <br />m <br />M '" <br />.. <br />'� <br />o <br />Z <br />E N <br />E ai <br />a <br />U ° ¢ p <br />JOB <br />NO: 23-00520 <br />SCALE : AS NOTED <br />SHEEP NO. <br />4.2 <br />Lt; <br />b, a <br />III ! , - .—.1TIr�i -.-�;. � i I o. . I ;,�:...r,. _.,..0 e. n�i.b.,,. a„i,. :�, ._ � _ � � � I;- �A� -� All � ti i - e � �r <br />