ELECTRICAL SPECIFICATION
<br />NOTES:
<br />ELECTRICAL CONTRACTOR
<br />MUST VERIFY WITH THE
<br />SPECIFICATIONS FOR THE TYPE
<br />OF FIXTURE TO BE USED, LIGHT
<br />FIXTURES SHOWN ARE FOR
<br />LOCATION PURPOSES,
<br />150A/200A INDOOR
<br />NEMA 1
<br />150 AMP/
<br />200 AMP
<br />4 to lights & outlets
<br />2 to appliances and GFI
<br />D to WH
<br />to Range
<br />to HVAC
<br />METER II
<br />�J
<br />150=2/0
<br />200,4/0 In 2" Conduit
<br />200 amp
<br />150 amp
<br />UNDERGROUND
<br />Disconnect
<br />SERVICE BY POWER CO.
<br />INTERSYSTEM
<br />4 Bare Cu Ground
<br />BONDING
<br />#4 GROUNDING WIRE
<br />TERMINATION PER
<br />WITH CODE APPROVED
<br />NEC 17, 250.94
<br />CLAMP PER 250.50 AND
<br />250,52 OF THE 2017 NEC.
<br />GENERAL ELECTRICAL NOTES:
<br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22
<br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE
<br />Notes: unless otherwise noted,
<br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL
<br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general).
<br />CODES AND THE LOCAL POWER/UTILITY COMPANY.
<br />In a Flood Zone, all electrical equipment to be at or above DFE.
<br />Kitchen 44" AFF
<br />Bathroom 39" AFF
<br />Laundry Room 36" AFF
<br />Exterior Waterproof 12" AFF
<br />Garage - general purpose 44" AFF
<br />Range 2" AFF
<br />2. All trim plates and devices to be ganged, where possible.
<br />3. Electrical switches to be at 42" centerline above finished floor.
<br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National
<br />Electric Codes (NEC 2017). by a licensed electrical contractor who shall be responsible for the installation &
<br />sizing of all electrical, wiring & accessories.
<br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217.
<br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch
<br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699.
<br />7, Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC
<br />2017).
<br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in
<br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be
<br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or
<br />UL 2075, gas and vapor detector sensor, according to the installation.
<br />9. R315.1,2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a
<br />Nationally Recognized Testing Laboratory.
<br />10. Keep all smoke detectors minimum of 36" from bathroom doors.
<br />11, In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be
<br />equipped with a monitored battery backup.
<br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not
<br />acceptable.
<br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying
<br />with R4501.17.1.1 through R4501,17.1.14,
<br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of
<br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle
<br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet
<br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance
<br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in
<br />corner counters.
<br />ELECTRICAL KEY
<br />DUPLEX CONVENIENCE OUTLET
<br />DUPLEX OUTLET ABOVE COUNTER
<br />PE�FW.P.
<br />WEATHERPROOF DUPLEX OUTLET
<br />G.F.I.
<br />GROUND FAULT INTERRUPTER DUPLEX OUTLET
<br />HALF -SWITCHED DUPLEX OUTLET
<br />fLph
<br />�
<br />SPECIAL PURPOSE OUTLET
<br />DUPLEX OUTLET IN FLOOR
<br />220 VOLT OUTLET
<br />WALL SWITCH
<br />(b
<br />THREE-WAY SWITCH
<br />?4
<br />FOUR-WAY SWITCH
<br />$R
<br />RHEOSTAT SWITCH
<br />CEILING MOUNTED LIGHT FIXTURE
<br />®
<br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX
<br />1-0
<br />WALL MOUNTED LIGHT FIXTURE
<br />ORECESSED
<br />LIGHT FIXTURE
<br />P.C.
<br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS
<br />---- `,
<br />TRACK LIGHT
<br />FLUORESCENT LIGHT FIXTURE
<br />116)
<br />EXHAUSTFAN
<br />;,,
<br />EXHAUST FAN/LIGHT COMBINATION
<br />®
<br />ELECTRIC DOOR OPERATOR (OPTIONAL)
<br />CH
<br />CHIMES (OPTIONAL)
<br />H
<br />PUSH BUTTON SWITCH (OPTIONAL)
<br />�D
<br />PUSH BUTTON SWITCH - DOOR BELL
<br />Sq
<br />SMOKE DETECTOR
<br />CM
<br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT)
<br />TELEPHONE (OPTIONAL)
<br />USB
<br />TELEPHONE/USB (OPTIONAL)
<br />N
<br />TELEVISION (OPTIONAL)
<br />©2
<br />(2) TELEVISION (OPTIONAL) (1)@ STD, HT, & (1)@ 60" A.F.F.
<br />THERMOSTAT
<br />ELECTRIC METER
<br />ELECTRIC PANEL
<br />DISCONNECT SWITCH
<br />G J
<br />ROUGH -IN FOR OPT. CEILING FAN
<br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR
<br />G J
<br />OPT. CEILING FAN
<br />W
<br />(1) PHONE LINE, (1) DATA PORT
<br />r----------------.--------._-----------,_--------
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />-------.----------_ --- —_----------_--- ----------
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />__j
<br />SECOND FLOOR ELECTRICAL PLAN - ELEV-Al
<br />SCALE: %4"=1'-0"
<br />eri
<br />N
<br />p
<br />N
<br />0
<br />wZ. U-J!
<br />of
<br />o
<br />ci =r. o
<br />GV
<br />�t `O-
<br />ao = —
<br />N y 0
<br />c
<br />d
<br />CD C
<br />a,
<br />itis �y m s"
<br />l0
<br />y CL
<br />coo E
<br />0
<br />cl- U
<br />r">
<br />cV
<br />ba
<br />c_y
<br />CV
<br />0
<br />To the best of the Englneer's knowledge, Information and belief,
<br />the structural
<br />plans and specifications contained within these
<br />drawings comply with the 2020 Florida Building Code -
<br />Residential
<br />7th Edition. Engineer's signature and seal Is only for
<br />the structural
<br />engineering portions of the drawing pages bearing
<br />Engineer's signature and seal.
<br />N
<br />Q o �
<br />0 co
<br />Clio
<br />.-d-LLW
<br />J LL LL , o
<br />d Y
<br />ZCA
<br />Z
<br />1,03
<br />Wj (eN (1) � o
<br />82r-
<br />W m
<br />Z N Ma Q J--
<br />R 0
<br />ZIL o�
<br />W ❑❑
<br />CD M �_
<br />N
<br /><c �
<br />--- N
<br />V) 2:
<br />0
<br />•U
<br />W S
<br />V) �
<br />=
<br />�n
<br />o
<br />U_
<br />tp
<br />Cl
<br />U
<br />0
<br />W
<br />~=
<br />Z
<br />D:
<br />UO
<br />ICU
<br />E
<br />O
<br />U
<br />� U
<br />Z
<br />o
<br />CID
<br />8
<br />'2
<br />N. C
<br />n
<br />�
<br />tiG
<br />m2
<br />p ¢
<br />ZJ
<br />m
<br />�+ m
<br />4 C
<br /><4
<br />�j�j
<br />V]
<br />6N'
<br />5.
<br />W
<br />nl
<br />0
<br />O
<br />>Lo
<br />LO
<br />LCL
<br />rn
<br />m
<br />co
<br />CT
<br />0
<br />,—
<br />�e
<br />W Q
<br />N
<br />m
<br />00
<br />L O
<br />T
<br />, j Vi
<br />0)
<br />Q)
<br />00
<br />In
<br />C'V
<br />vM'` N
<br />Q a
<br />r
<br />m
<br />M '"
<br />..
<br />'�
<br />o
<br />Z
<br />E N
<br />E ai
<br />a
<br />U ° ¢ p
<br />JOB
<br />NO: 23-00520
<br />SCALE : AS NOTED
<br />SHEEP NO.
<br />4.2
<br />Lt;
<br />b, a
<br />III ! , - .—.1TIr�i -.-�;. � i I o. . I ;,�:...r,. _.,..0 e. n�i.b.,,. a„i,. :�, ._ � _ � � � I;- �A� -� All � ti i - e � �r
<br />
|