Laserfiche WebLink
2" SOUND ATTENUATION <br />BATT INSULATION <br />STAGGER ALL VERTICAL AND <br />HORIZONTAL JOINTS 32m O.C. EACH <br />SIDE AND OPPOSITE SIDES <br />5w NOMINAL- <br />4 7/8"ACTUAL <br />3 5/8" STL STUDS <br />AT ION O.C. <br />CAULKi <br />BOTH SIDES TYP. <br />SOUND TRANSMISSION RATING: <br />45 STC (MIN) <br />TYPICAL STUD WALL <br />1 1/2" V-0' <br />FLOOR, BASE, AND WALL FINISH <br />SEE FLOOR PLANS - <br />EXIST. STRUCTURE ABOVE <br />\-AT METAL DECK, SEAL AROUND <br />DECK FLUTES - FILL W/ FIRE STOP <br />INSULATION, NOTCH GYP. BD., <br />AND CAULK <br />SEE FINISH SCHEDULE AND <br />REFLECTED CEILING PLAN <br />FOR TYPE AND HEIGHT OF CEILING <br />;;;jj1e; <br />I EEE�=_, <br />(1) LAYER OF 5/8- CEMENT BOARD <br />TO 4'-00 A.F.F WITH 5/80 GYPSUM BOARD <br />ABOVE, BOTH SIDES TYP. <br />STAGGER ALL VERTICAL AND <br />HORIZONTAL JOINTS 32w O.C. EACH <br />SIDE AND OPPOSITE SIDES <br />INSTALL TRACK ON CONTINUOUS <br />1/4" THICK X 30 WIDE POLYETHELENE <br />FOAM GASKET - AMOFOAM SILL SEALER, <br />PROVIDE FIRE STOP ON ALL SMOKE <br />PARTITIONS, SEE LIFE SAFETY PLAN <br />EXIST. STRUCTURE ABOVE <br />AT METAL DECK, SEAL AROUND <br />DECK FLUTES - FILL W/ FIRE STOP <br />INSULATION, NOTCH GYP. BD., <br />AND CAULK <br />SEE FINISH SCHEDULE AND <br />REFLECTED CEILING PLAN <br />FOR TYPE AND HEIGHT OF CEILING <br />2w SOUND ATTENUATION BLANKETS <br />(1) LAYER OF 5/8' CEMENT BOARD, <br />BOTH SIDES TYP. <br />STAGGER ALL VERTICAL AND <br />HORIZONTAL JOINTS 32* O.C. EACH <br />SIDE AND OPPOSITE SIDES <br />3 5/8w OR 15/8" STL STUDS AT <br />lLr O.C. (BRACED) <br />CAULK, BOTH SIDES TYP. <br />SOUND TRANSMISSION RATING: INSTALL TRACK ON CONTINUOUS 1/4" THICK X 2" <br />59 STC (MIN) WIDE POLYETHELENE FOAM GASKET - <br />AMOFOAM SILL SEALER, PROVIDE FIRE STOP ON <br />ALL SMOKE PARTITIONS, SEE LIFE SAFETY PLAN <br />PLUMBING STUD WALL 1 HR FIRE RATED <br />1112' <br />u u u <br />VDECK FLUTES - FILL W/ FIRE STOP <br />/AT METAL DECK, SEAL AROUND <br />INSULATION, NOTCH GYP. BD., <br />ANDCAULK <br />5"NOMINAL- <br />4 7/8" ACTUAL <br />3 5/8" STL STUDS <br />AT 16" O.C. <br />CAULK; <br />BOTH SIDES TYP. <br />TYPICAL STUD WALL <br />1 1/20 = l'-Ow <br />(1) LAYER OF 518' CEMENT BOARD <br />FULL WALL HEIGHT <br />STAGGER ALL VERTICAL AND <br />HORIZONTAL JOINTS 32" O.C. EACH <br />SIDE AND OPPOSITE SIDES TAPE & <br />SPACKLE AS PER GYP BD <br />SPECIFICATIONS <br />5w NOMINAL- <br />4 7111' ACTUAL <br />3 518' STL STUDS <br />AT 16" O.C. <br />CAULKj <br />BOTH SIDES TYP. <br />STUD WALL <br />I lt2n 1'-�V <br />EXIST. CMU WALL <br />FURRED PARTITION <br />1117 1'-0` <br />—EXIST. STRUCTURE ABOVE <br />BRACE TO <br />STRUCTURE ABOVE <br />STEEL STUD TRACK FIRESTOP <br />//--BETWEEN STUDS <br />SEE FINISH SCHEDULE AND <br />REFLECTED CEILING PLAN <br />FOR TYPE AND HEIGHT OF CEILING <br />ES61 IM; I 1 <br />—(I) LAYER OF 5ff CEMENT BOARD <br />TO W4r A.F.F WITH 5ff GYPSUM BOARD <br />ABOVE, BOTH SIDES TYP. <br />— STAGGER ALL VERTICAL AND <br />HORIZONTAL JOINTS 32m O.C. EACH <br />— SIDE AND OPPOSITE SIDES <br />INSTALL TRACK ON CONTINUOUS <br />/-1/40 THICK X 3"WIDE POLYETHELENE <br />FOAM GASKET - AMOFOAM SILL SEALER, <br />PROVIDE FIRE STOP ON ALL SMOKE <br />PARTITIONS, SEE LIFE SAFETY PLAN <br />EXIST. STRUCTURE ABOVE <br />R4.3, 1 112' RIGID INSUL. BETWEEN <br />15/80 STL STUDS AT 16" O.C. <br />SEE FINISH SCHEDULE AND <br />REFLECTED CEILING PLAN <br />FOR TYPE AND HEIGHT OF CEILING <br />(1) LAYER OF 5/8- CEMENT BOARD <br />TO 4'-Ow A.F.F WITH 5/8' GYPSUM BOARD <br />ABOVE <br />FLOOR, BASE, AND WALL FINISH <br />SEE FLOOR PLANS <br />CAULK, TYP. <br />INSULATI <br />RATING: <br />59 STC (MIN) <br />PLUMBING STUD WALL <br />to <br />EXIST. CMU WALL <br />FURRED PARTITION <br />1 Iff 0 1'-V <br />METAL LATH ONia# ASPHALTIC BUILDING <br />7W TW CEMENT PLASTER ON GALV. <br />PAPER ON MST CMU <br />OR <br />711r THK CEMENT PLASTER ON NEW CMU <br />-_8!- ON A. F. �F. <br />(93.9r) <br />7/8w THK CEMENT PLASTER ON <br />GALV. METAL LATH ON 2 LAYERS <br />OF 1/20 THICK CEMENT BOARD <br />Exterior <br />tUCTURE ABOVE <br />- SEE FLOOR PLAN <br />SEE FINISH SCHEDULE AND <br />REFLECTED CEILING PLAN <br />FOR TYPE AND HEIGHT OF CEILING <br />2" SOUND ATTENUATION BLANKETS <br />-(I) LAYER OF 5/8' CEMENT BOARD <br />- 3 5/8' OR 15/80 STL STUDS AT <br />ION O.C. (BRACED) <br />-FLOOR, BASE AND WALL FINISH <br />SEE FLOOR PLANS <br />-CAULK <br />INSTALL TRACK ON CONTINUOUS <br />1/40 THICK X 20 WIDE POLYETHELENE <br />FOAM GASKET - AMOFOAM SILL <br />SEALER, PROVIDE FIRE STOP ON <br />ALL SMOKE PARTITIONS, <br />SEE LIFE SAFETY PLAN <br />WE FINISH SCHEDULE AND <br />10 LE10TED CEILING PLAN <br />FOR TYPE AND HEIGHT OF CEILIING <br />2' SOUND ATTENUATION BLANKETS <br />EXIST. CONC. FLOOR ABOI <br />-AT METAL DECK, SEAL AROI <br />DECK FLUTES - FILL W/ FIRE <br />INSULATION, NOTCH GYP. B <br />AND CAULK <br />(1) LAYER OF 5ff CEMENT BOARD <br />TO W-Cr A.F.F WITH 6ff TYPE Or <br />GYPSUM BOARD ABOVE, <br />BOTH SIDES TYP. <br />STAGGER ALL VERTICAL AND <br />HORIZONTAL JOINTS 32* O.C. EACH <br />SIDE AND OPPOSITE SIDES <br />3 5/8* OR 1518" STL STUDS AT <br />12' O.C. (BRACED) <br />FLOOR, BASE, AND WALL FINISH <br />SEE FLOOR PLANS _CAULK, <br />BOTH SIDES TYP. <br />WIDE POLYETHELENE FOAM GASKET - <br />SOUND TRANSMISSION RATING: INSTALL TRACK ON CONTINUOUS 1/4" THICK X 2m <br />59 STC (MIN) <br />AMOFOAM SILL SEALER, PROVIDE FIRE STOP ON <br />ALL SMOKE PARTITIONS, SEE LIFE SAFETY PLAN <br />\ �l �HR _F1 R ER AT E.D S.T U DW.A L �L <br />I lw m 1,4r UL RATING NO. U420 <br />EXIST. STRUCTURE ABOVE DECK OR STRUCTURE ABOVE - <br />SEE STRUCT. DWGS. <br />—I 5W STL STUDS AT ISO O.C. <br />AT METAL DECK SEAL AROUND <br />DECK FLUTES WITH CONCRETE <br />BRICK AND MORTAR SEE FINISH SCHEDULE AND <br />REFLECTED CEILING PLAN <br />I H_ FOR TYPE AND HEIGHT OF CEILING <br />SEE FINISH SCHEDULE AND F-1 I -A <br />REFLECTED CELING PLAN .11-1- 1 1 <br />FOR TYPE AND HEIGHT OF CEILING H- I <br />80 CONCRETE BLOCK <br />(1) LAYER OF 51W CEMENT BOARD SEE STRUCT. DWGS. Ir NOLINAL <br />TO 4-W A.F.F WITH 5V GYPSUM BOARD <br />ABOVE ..... 7 Off ACTUAL <br />FLOOR, BASE, AND WALL FINISH ..... <br />SEE FLOOR PLANS <br />FLOOR, BASE, AND WALL FINISH <br />SEE FLOOR PLANS <br />CAULK BOTH SIDES TYP. RI <br />STUCCO BAND DETAIL <br />3' a IW <br />--------- <br />.......... <br />SEE LIFE SAFETY PLANS <br />FOR FIRE RATING REQ. <br />BLOCK WALL PARTITION <br />1 112" 1 %0" <br />NEW OR EXIST. <br />CMU 7-7/ <br />I F7. _77: 7�.'j <br />CEMENT PLASTER ON GALV.— <br />METAL LATH ON IS# ASPHALTIC <br />BUILDING PAPER <br />Interior CASING BEAD & SED&ANTY <br />DETAIL <br />3"m I'4r <br />EXIST. CMU <br />LEVELING COAT STUCCO ON <br />SCRATCH COAT STUCCO ON <br />GALV. METAL LATH ON 15# <br />ASPHALTIC BUILDING PAPER <br />1/2' THICK THIN BRICK ON <br />BONDING MORTAR <br />LEANDRO A. ARROYO <br />FL. REG. NO. 12326 <br />CITY OF ZEPHYRHILLS <br />RENOVATION <br />OF <br />FIRE RESCUE <br />STATION NO. 2 <br />CONSTRUCTION <br />DOCUMENTS <br />0 <br />12-07-2012 <br />0 <br />CB+A #1202 <br />0 <br />CANERDAY <br />BELFSKY <br />+ <br />ARROYO <br />ARCHITECTS <br />OW SECOND AVENUE SOUTH <br />ST. PETERSBURG. FL 33701 <br />(727) 823-W75 <br />AA20000567 <br />NN <br />PARTITION TYPES AND DETAILS A9m5 <br />SCALL, M NUM <br />