Laserfiche WebLink
LIGHT GAGE COLD FORMED STEEL ROOF TRUSS SHOP DRAWING NOTES: <br />"SPECIALTY" DELEGATED STRUCTURAL ENGINEER NOM <br />PLAIN & REINFORCED MASONRY NOTES CONTINUE THIS SHEET. <br />34. GENERALLY, REINFORCING SHALL NOT BE CUT TO ACCOMMODATE THE INSTALLATION OF <br />EMBEDS, ANCHORS, SLEEVES ANDfOR OTI IER ITEMS. WHERE SUCI I IS UNAVOIDABLE, <br />NOTIFY THE STRUCTURAL ENGINEER OF THE INTENTION TO DO SO, AND PROVIDE ONE <br />ADDITIONAL BAR EACH SIDE OF THE BAR WHICH WAS CUT, SIZE OF ADD BARS SHALL <br />MATCH SIZE OF ORIGINAL BAR AND LENGTH SHALL BE ADEQUATE TO AT LEAST PROVIDE <br />FOR A 48 X BAR DIAMETER LAP (OR EMBEDMENT) EACH SIDE OF THE BAR WHICH WAS CUT. <br />35. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER DESIGN AND CONSTRUCTION <br />OF ALL NECESSARY FORMWORK, SHORING AND RESHORING. THE DESIGN SHALL BE <br />PREPARED BY A PROFESSIONAL ENGINEER CURRENTLY REGISTERED IN THE STATE OF <br />INTENDED CONSTRUCTION OF THE PROJECT AND ERECTION DRAWING SHALL BEAR HIS <br />SEAL, SIGNATURE AND THE DATE. ERECTION DRAWINGS SHALL BE SUBMI I I ED TO THE <br />RESPONSIBLE BUILDING AUTHORITY. <br />36. THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE FOR PROPER STORAGE OF <br />MASONRY MATERIALS ON THE CONSTRUCTION SITE AND TO ASSURE THAT THE MATERIALS <br />AND CMU's REMAIN CLEAN AND DRY AT ALL TI MES PRIOR TO PLACEMENT. <br />37. WHILE MASONRY WALLS ARE BEING CONSTRUCTED, 17 IS THE RESPONSIBIL17Y OF THE <br />MASON TO BE SURE THAT THE WALLS ARE COVERED AT ALL TIMES (WHEN NOT BEING <br />WORKEDON). THE COVERING CAN BE PLASI IC, CANVAS OR 01 HER SUITABLE <br />WATERPROOF MATERIAL THAT NOT ONLY COVERS THE TOP OF THE WALL, BUT ALSO <br />PROJECI[S DOWN AT LEAST TWO FEET ON EACH SIDE OF THE WALL. THIS IS 10 ENSURE <br />THAT WATER DOES NOT ENTER THE OPEN CELLS AND THAT THE WALLS DO NOT BECOME <br />SATURATED. PARTIALLY COMPLETED MASONRY WALLS THAT ARE EXPOSED TO RAIN <br />MAY BECOME SO SATURATED WITH WATER THAT THEY TAKE MONTHS TO DRY OUT. THIS <br />CAN ALSO CAUSE EFFLORESCENCE. IN ADDITION, SATURATION OF MASONRY WALLS WILL <br />INCREASE THE AMOUNT OF SHRINKAGE CRACKING IN THE WALLS AND THE CONTRACTOR <br />AND MASON WILL BE RESPONSIBLE TO REMEDIATE THE CRACKING SITUATION. <br />STRUCTURAL STEEL -GENERAL NOTES: <br />1. ALL STRUCTURAL STEEL WORK SHALL BE DETAILED, FABRICATED AND ERECTED IN <br />ACCORDANCE WITH THE THIRTEENTH ED17ION OF THE A.I.S.C. STEEL CONSTRUCTION <br />MANUAL WITH THE "SPECIFICATION FOR THE DESIGN OF STEEL BUILDINGS" AND "CODE OF <br />STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES". <br />2. A. ALL ROLLED WIDE FLANGE STEEL SHAPES SHALL CONFORM TO ASTM SPECIFICATION <br />A-992 (Fy=50KSI) UNI FSS NOTED OTHERWISE <br />B. ALL OTHER STRUCTURAL STEEL S1 TAPES &PLATE SHALL CONFORM TO ASTM <br />SPECIFICATION A-36 (Fy--36KSI MIN.) UNLESS NOTED OTHERWISE. <br />3. ALL ROUND HISS STEEL PIPE COLUMNS SHALL CONFORM TO ASTM SPECIFICATION A-501 <br />(Fy=36KSI) OR ASTM A-53, TYPES E OR S, GRADE B (Fy=35KSI). <br />4. ALL FISS (T.S.) STEEL TUBE SECTIONS SHALL CONFORM TO ASTM SPECIFICATION A-50 <br />GRADE B (Fy=46 KSI). <br />NOTE: ALL FASTENERS AND MATERIALS USED FOR WELDI NG OR OTHER <br />CONNECTIONS CF STRUCTURAL STEEL FRAMING MEMBERS AND COMPONENTS <br />SHALL BEOF DOMESTIC MANUFACTURE. LIKEWISE, ALL MATERIALS USED IN <br />THE MANUFACTURING PROCESS OF CONNECTION COMPONENTS SHALL BE <br />FROM A DOMESTIC SOURCE. <br />5. ALL ANCHOR BOLTS SHALL CONFORM TO ASTM SPECIFICATION A-36 (Fy=36 KS1), (Fu=58 KSI), <br />(U.N.O.). <br />6. ALL STRUCTURAL CONNECTION BOLTS SHALL BE CONFORM TO ASTM SPECIFICATION A-325 <br />(Fu=120 KSI), (U.N.O.). <br />7. "HSA" HEADED 51 LID ANCHORS SHALL BE MADE FROM COLD FORMED BAR SIOUK <br />CONFORMING TO ASTM A108, GRADES 1C10 THRU 1020 INCLUSIVE AS MANUFACTURED BY <br />NELSON STLin <br />8. PAINT (IN FAB SHOP) ALL STRUCTURAL STEEL EXCEPT FOR SURFACES TO BE EMBEDDED IN <br />CONCRETE, FIELD WELDED, OR COVERED WITH SPRAY ON FIRE PROOFING, APPLY PAINT IN <br />ACCORDANCE WITH SSPC­PA1, SHOP FI ELD AND MAINTENANCE PAINTING, APPLY PAINT IN <br />SUFFICIENT COLUMN OR COATS TO PROVIDE A MINIMUM DRY FILM THICKNESS OF AT LEAST <br />3MILSBUTNOTMORETHAN4MILS. PREPARE STEEL SURFACE IN ACCORDANCE WITH <br />SSPC SP3 POWER TOOL CLEAN] NG. ANY METHOD IN CONFORMANCE WITH SSPC <br />SPECIFICATION OF HIGI IER QUALITY THAN LISTED WILL BE ACCEPTABLE. AT THE <br />ON WHEEL ABRATOR MAY BE USED FOR PREPARATION OF STEEL <br />SURFACES, PROVIDING RESULTANT SURFACE IS EQUAL IN ALL RESPECTS TO THOSE <br />REQUIRED. FIELD TOUCH-UP OF PAINT IS REQUIRED PRIMING AND PAINTING OF ALL FIELD <br />WELDS IS REQUIRED AFTER COMPLETION OF INSPECTIONS. <br />9. ALL STRUCTURAL STEEL HAVING EXTERIOR EXPOSURE SHALL BE HOT DIP GALVANIZED <br />UNLESS OTHERWISE INDICATED. <br />10, ALL BOLT ED CONNEU f IONS SHALL BE A-32b IYPE N. (U.N.U.). TIGHTENING OF BOLTS I 0 <br />BE BY AISC'7URN OF THE NUT" METHOD OR APPROVED DI RECT TENSION INDICATOR. <br />(AISC "SNUG TIGHT"TIGHTENING IS PERMISSIBLE). BOLTED CONNECTIONS SHALL <br />CONFORM TO THE REQUIREMENTS OF THE "SPECIFICATICIN FOR STRUCTURAL JOINTS <br />USING ASTM A-325 OR A-490 BOLTS" AS APPROVED BY THE RESEARCH COUNCIL ON <br />STRUCTURAL CONNECTIONS. <br />11. PROVIDE WASHERS TO MATCH BOLT STRENGTH FOR ALL STRUCTURAL BOLTS (ON THE <br />SIDE OF THE TURNED ELEMENT). PROVIDE WASHERS BOTH NUT AND HEAD SIDE OF BOLTS <br />FOR SLOTTED AND LONG SLOTTED HOLES. <br />12. WELDING SHALL CON70RM TO THE LATEST EDITION OF THE CODE OF THE AMERICAN <br />WELDING SOCIFTY, AWS D1 1 <br />13. ALLWELDING SHALL BE DONE BY CERTIFIED WELDERS WHO HAVE QUALIFIED BY TEST AS <br />PER AWS "STANDARD QUALIFICATION PROCEDURE" AND SHALL HAVE CERTIFICATES <br />AVAILABLE ON THE JOB SITE FOR INSPECTION. <br />14. ALL WELDING SHALL BE DONE UTILIZING E-70 ELECTRODES AND SHALL BE DONE IN <br />ACCORDANCE WITH AWS D1. 1, LATEST EDITION, "CODE FOR WELDING IN BUILDING <br />CONSTRUCTION". MINIMUM WELD SIZE SHALL BE PER AISC 1.17.2. UNLESS OTHERWISE <br />NOTED, ALL WELDS SHALL BE CONTINUOUS. <br />15. ALL WELDS SHALL BE INSPECTED AND CERTIFIED BY AN "AWS - (CWI) CERTIFIED WELDING <br />INSPECTOR", HOLDING CURRENT CERTIFICATION IN ACCORDANCE WITH THE AWS QCI <br />PROGRAM WHO SHALL BE RETAINED BY THE CONTRACTOR. THE TESTING LABORATORY <br />SHALL PROVIDE EVIDENCE OF CURRENT CERTIFICATION OF THE WELDING INSPECTOR <br />PRIOR TO FIRST SITE VISIT. INSPEC71ON 13Y NON CERTIFIED INSPECTORS WILL NOT BE <br />ACCEPTABLE! <br />A. INSPECTION SHALL BE IN ACCORDANCE WITH AWS STRUCTURAL WELDING CODE. <br />B. VISUALLY INSPECT ALL FIELD -WELDED CONNECTIONS. VISUAL INSPECTION OF WELDED <br />JOINTS INCLUDES PERIODIC EXAMINA71ON OF FITUP. <br />C. ULTRASONICALLY INSPECT 100% OF THE COMPLETE PENETRATION WELDS. <br />D. REVIEW APPROVED WELDING PROCEDURES. VERIFY THAT WELDING PROCEDURES <br />ARE BEING ADHERED TO DURING FIELD WELDING- <br />E. VERIFYWELDER QUALIFICATIONS- <br />16. SUBMIT SHOP DRAWINGS TO THE ARCHITECT FOR HIS REVIEW. SHOP DRAWINGS SHALL <br />INCLUDE ALL STRUCTURAL STEEL MEMBERS, SIZES, LAYOUT, CONNECTIONS, WELDS, TYPE <br />OF STEEL, BOLTS, ETC., REQUIRED TO FABRICATE AND ERECT THE STEEL FRAMING. SHOP <br />DRAWINGS SUBMITTAL SHALL FOLLOW INSTRUCTIONS GIVEN IN THE SHOP DRAWING <br />NOTES. <br />17. PRIOR TO FABRICATION, VERIFY EXACT SIZE AND LOCATION OF ALL ROOF <br />OPENINGS WITT I ARCHITECT, MECHANICAL ENGINEER AND MECHANICAL CONTRACTOR. <br />18. PRIOR TO FABRICATION, GENERAL CONTRACTOR ANDIOR STEEL FABRICATOR SHALL FIELD <br />VERIFY EXACT REQUIRED LENGTH(S) OF STRUCTURAL STEEL AND/OR BAR JOIST MEMBERS <br />WHICH FRAME INTO AND/OR ARE SUPPORTED BY CONCRETE AND/OR MASONRY ELEMENTS. <br />19. NO SPLICES SHALL BE PERMIT -FED IN ANY STRUCTURAL STEEL MEMBERS UNLESS SHOWN <br />ON SHOP DRAWINGS AND APPROVED BY THE STRUCTURAL ENGINEER. <br />20 UNLESS OTHERWISE NOTED OR DETAILED, PROVIDE CORRUGATED MASONRY WALL <br />ANCHORS (MIN. OF 14 GAGE) AT 16" O/C WELDED TO STEEL TO CONNECT MASONRY WALLS <br />TO ADJACENT STRUCTURAL STEEL FRAMING. <br />21. COLUMN BASE PLATE GROUT SHALL BE:NONMETALLIC SHRINKAGE RESISTANT GROUT, <br />PREMIXED, NON CORROSIVE, NON STAINING PRODUCT CONTAINING SELECTED SILICA <br />SANDS, PORTLAND CEMENT, SHRINKAGE COMPENSATING AGENTS, PLASTICIZING AND <br />WATER REDUCING AGENTS, COMPLYING WITH CRD-C621, CORPS OF ENGINEERS. <br />22 STEEL ERECTION NOTES: <br />A BEFORE ERECTION, THE CONTRACTOR IS TO REN40VE A[ L FOREIGN MATTER, WHICH <br />ACCUMULATED ON THE STEEL DURING HANDLING AND STORAGE. <br />B. DRIFTING TO ENLARGE UNFAIR HOLES WILL NOT BE PERMITTED. DRILL SUCH HOLES TO <br />ACCOMMODATE THE NEXT LARGER SIZE FASTENER, WHERE POSSIBLE. <br />C. AFTER ERECTION, CLEAN FIELD WELDS, BOLTED CONNECTIONS, AND ABRADED AREAS <br />WHERE SHOP PAINT HAS BEEN DAMAGED. PRIME& PAINT AREAS USING PAINT TO <br />MATCH SHOP PAINT. <br />D. ERECTALL MEMBERS IN THEIR FINAL LOCATION SUCH THAT LEVEL, PLUMBNESS AND <br />ALIGNMENT ARE WITHIN THE TOLERANCES PRESCRIBED BYAISC CODE. <br />F DOURI F ANGLE CONNECTIONS ROLTED THROUGH COT UMN WEBS OR AT BEAMSTHAT <br />FRAME OVER THE COLUMN CAP PLATES MUST HAVE AT LEAST ONE INSTALLED BOLT <br />REMAIN IN PLACE TO SUPPORT THE FIRST BEAM WHILE THE SECOND BEAM IS BEING <br />ERECTED, ALTERNATIVELY, THE FABRICATOR MUST SUPPLY A SEAT OR EQUIVALENT <br />DEVICE WITH A MEANS OF POSITIVE ATTACHMENT TO SUPPORT THE FIRST BEAM WHILE <br />THE SECOND BEAM IS BEING ERECTED. <br />OPEN WES STEEL JOISTS AND JOIST GIRDERS NOTES: <br />1. BRIDGING MEMBER SIZE AND LOCATION SHALL BE PER PLAN AND SPECIFICATIONS. THE <br />BRIDGING SHOWN ON THE FRAMING PLANS IS THAT MINIMUM BRIDGING WHICH IS <br />REQUIRED. <br />NOTE� BRIDGING IS PROVIDED AS A CHORD BRACING ELEMENT IN THE DESIGN AND <br />ERECTION OF I HE BAR JOISTS. EIRIDGING MEMBERS ARE DESIGNED AND INTENDED <br />TO FUNCTION AS AXIALLY LOADED MEMBERS. USE Or- BRIDGING FOR SUPPORT OF <br />SUSPENDED ITEMS INTRODUCES BENDING MOMENTS INTO THE BRIDGING, FOR <br />WHICH IT IS NOT DESIGNED. THE G.C. SHALL INFORM ALL SUBCONTRACTORS TO <br />PROVIDE THEIR OWN SUPPORT HEADFRS FOR HANGING THEIR EQUIPMFNTAND TO <br />NOT USE BRIDGING FOR HANGER SUPPORT. <br />2. PROVIDE ONE ROW UPLIFT BRIDGING ATTHE FIRST PANEL POINT FROM EACH SUPPORT. <br />3. WELDING OF JOIST SEATS TO NEW STEEL SUPPORTING CHANNEL TOP <br />FLANGE: <br />A) 118" FILLETWELD X 1 1/2" LONG (MIN) EA. SIDE OF SEAT. <br />NOTE: BAR JOIST- SUPPORT WELDING & BRIDGING SHALL BE INSPECTED BY AN AWS <br />CERTIFIED WELDING INSPECTOR RETAINED BY THE CONTRACTOR. THE "CW11, <br />SHALL HAVE BEEN CERTIFIED BY THE AWS QCI PROGRAM. THE "CWI" SHALL <br />INSPECT AND PREPARE AND ISSUE REPORTS WHICH INDICATE COMPLIANCE (OR <br />LACKTHEREOF) OF THE WELDING AND BRIDGING WITH RESPECT TO THAT <br />SPECIFIED ON THE DESIGN DOCUMENTS AND SHOP DRAWINGS AND INDICATE ANY <br />AREAS WHERE CORRECTIVE WORK WILL BE REQUIRED. SUCH REPORTS SHALL BE <br />DISTRIBUTED TO THE OWNER, ARCHITECT, STRUCTURAL ENGINEER AND GENERAL <br />CONTRACTOR. <br />METAL ROOF DECK FASTENING REQUIREMENTS: <br />1. SEE PLANS FOR METAL ROOF DECKTYPE(S). DECK SHALL BE MANUFACTURERS STANDARD <br />GAGE OR GALVANIZED SHEET GAGE AND SHALL CONFORM TO THE STEEL DECK INSTITUTE <br />SPECIFICATIONS. <br />2. WELDING SHALL CONFORM TO LATEST A_W.S SPECIFICATIONS. ALL SHOP AND FIELD <br />WELDS SHALL BE PERFORMED BY QUALIFIED WELDERS HOLDING VALID WELDING <br />CERTIFICATES. CERTIFICATES SHALL BE AVAILABLE FOR INSPECTION AT JOB $11 E WHILE <br />WELDER IS ON THE JOB. <br />3. DECK SHALL BE FASTENED AS FOLLOWS <br />A. ONE WELD SHALL BE PLACED AT THE CORNER OF EACH SHEET AND AT OVERLAPPING <br />CORNERS OF SHEETS. <br />B. EACH SHEET OF METAL ROOF DECK SHALL BE WELDED AT ITS ENDS TO EACH <br />SUPPORTING BEAM OR JOIST AT NOT MORE THAN 6" 0 C (36/7 WELD PATTERN). <br />C. WELD SPACING AT INTERMEDIATE BEAM OR JOIST (BETWEEN ENDS OF DECK SHEETS) <br />SHALL NOT EXCEED 6" O.C. (36f7 WELD PATTERN). <br />D, WELD SPACING AT PERIMETER OF DIAPHRAGM (EDGE OF DECK) B07H PARALLEL AND <br />PERPENDICULAR TO DECK RIBS SHALL NOT EXCEED 6" O.0 (36f7 WELD PATTERN), <br />E. WELD SPACING AT SHEARWALLS AND OTHER SUCH BRACING ELEMENTS (WALLS WHICH <br />EXTEND TO THE ROOF AND SHOW ON THE ROOF PLAN) SHALL NOT EXCEED 6" O.C. (36f7 <br />WELD PA I -TERN). <br />F. ROOF DECK SIDE LAPS SHALL BE FASTEN ED TOGETHER WITH EITHER 1-1/21, SEAM <br />WELDS AT 12" O.0 OR NO, 12 HEX HEAD SELF DRILLING SF1 F TAPPING SCREWS SPACIFD <br />AT 12"O.C. <br />4. WELDS SHALL BE 5/8" DIAMETER FUSION PUDDLE WELDS UTILIZING WELDING WASHERS <br />FOR DECK MATERIAL LIGHTER THAN 22 GAGE. <br />5. END LAPS (ALL MATERIAL) SHALL BE NOT LESS THAN 2", SHALL OCCUR OVER JOIST OR <br />BEAM AND SHALL BE WELDED THROUGH TOP SHEET. <br />6. ALL ROOF DECK FASTENINGS (PUDDLE WELDS, SIDE LAP SCREWS, ETC.) SHALL BE <br />INSPECTED AND CERTIFIED BY AN "AWS" (CWI) CERTIFIED WELDING INSPECTOR HOLDING <br />CURRENT CERTIFICATION IN ACCORDANCE VV17H THE AWS QCI PROGRAM, WHO SHALL BE <br />RETAINED BY THE CONTRACTOR. THE C.W.I. SHALL PREPARE AND DISTRIBUTE WRITTEN <br />DOCUMENTATION OF ACCEPTABILITY (OR LACK THEREOF) OF FASTENINGS WITH <br />RFSPECTTO THE CONTRACT DOCUMENT REQUIREMENTS. COPIFSOFTHECWI'S <br />REPORTS SHALL BE SENT TO THE OWNER, ARCHITECT, STRUCTURAL ENGINEER AND <br />GENERAL CONTRACTOR. <br />7. DECK SHEET WIDTHS ARE ASSUMED TO BE 36 INCHES FOR I 'A INCH DEEP DECK. PROVIDE <br />DECKWITH G-60 (MIN.) GALVANIZED FINISH). <br />8. DECK SHALL BE CONTINUOUS ACROSSTHREE SPANS, EXCEPTWHERE GEOMETRY OR <br />STEEL LAYOUT DICTATES OTHERWISE. <br />9. EACH SHEET OF ROOF DECK SHALL BE SUPPORTED AT ALL EDGES. IFSTRUCTURAL <br />SUPPORT IS NOT SPECIFICALLY INDICATED ON THE PLANS, PROVIDE (AS A MINIMUM) AN <br />L 3 X 3 X 114" (SPANNING BETWEEN CLOSEST ADJACENT MEMBERS) AT ALL UNSUPPORTED <br />EDGESOFDECK. (MINIMUM BEARING OF ROOF DECK ON SUPPORTS SHALL BE 2 INCHES). <br />10. PROVIDE "Z" MEMBER AT SIDES OF DECK (PARALLEL TO DECK SPAN) FOR CLOSURE AND <br />DECK SUPPORT ABOVE SPANDREL MEMBER. MIN. WELD TO MATCH DECK FASTENING <br />REQUIREMENTS. MIN. GAGE OF"Z" MEMBER SHALL BE 18 GAGE. <br />11, MATERIALS AND FASTENINGS SHALL CONFORM TO THE MORE STRINGENT <br />REQUIREMENT <br />OF THE FOLLOWING CRITERIA: <br />A. THE CONTRACT DOCUMENTS <br />B. THE DECK MANUFACTURER'S REQUIREMENTS <br />C THE STEEL DECK INSTITUTE "DESIGN MANUAI FOR COMPOSITE DECKS, FORM DECKS <br />AND ROOF DECKS". <br />12. SHOULD THE FABRICATOR CHOOSE TO SUBMIT AN ALTERNATE DECK MANUFACTURER'S <br />PRODUCT FOR APPROVAL, LITERATURE SHALL BE SUBMITTED FROM THE PRO POSED <br />SUBSTITUTE MANUFACTURER INDICATING SECTION PROPERTIES, RIB PROFILE, THICKNESS <br />OF DECK MATERIAL (IN INCHES) AND LOAD TABLES. <br />13. ALL ROOF DECK AND SHEET METAL ACCESSORIES SHALL BE GALVANIZED (G-90 MIN.). <br />NOTE: PROVIDE G-90 GALVANIZED FINISH WHERE DECK IS SUPPORTING POURED IN <br />PLACE LIGHTWEIGHT INSULATING CONCRETE. <br />LIGHT GAGE STEEL ROOF TRUSS FABRICATION, BRACING AND ERECTION NOTES: <br />1, ALL LIGHT GAGE TRUSSES SHALL BE PREFABRICATED IN THE SHOP AND SHIPPED TO THE <br />JOBSITE. JOBSITE FABRICATION OF TRUSSES WILL NOT BE PERMITTED, SHOULDFIELD <br />SPLICING OF TRUSSES BE REQUIRED, THE SPLICE HARDWARE AND FASTENERS SHALL BE <br />SHOP FABRICATED AND SHIPPED TO THE SITE AND THE TRUSS MANUFACTURER SHALL <br />SUPERVISE; THE ASSEMBLY OF THE JOBSITE SPLICES. <br />2, TRUSSES REQUIRF EXTREME CARE IN FABRICATING, HANDLING. SHIPPING, INSTALLATION <br />ANDBRACING REFER TO HIB-91 "HANDLING, INSTALLATION AND BRACING", PUBLISHED BY <br />THE TRUSS PLATE INSTITUTE, FOR GENERAL GUIDANCE IN SAFETY PRACTICES PRIOR TO <br />PERFORMING THESE FUNCTIONS. ADDITIONALLY, REFER TO THE "DESIGN GUIDE FOR <br />CONSTRUCTION BRACING OF COLD FORMED STEEL TRUSSES"TECHNICAL NOTE <br />PUBLISHED BY THE LIGHT GAUGE STEEL ENGINEERS ASSOCIATION, FOR ADDITIONAL <br />GUIDANCE IN THE DESIGN OF THE BRACING SYSTEM. <br />3. ALL BRACING SHOWN OR DESCRIBED SHALL BE, (AS A MINIMUM), A 15OF125-43 FURRING <br />CHANNEL PURLIN MEMBER CONTINUOUS) HAVING A MINIMUM CONNECTION OF (2) NO. 12 <br />SELF DRILLING SELFTAPPING SCREWS THROUGH EACH TRUSS WITH WHICH IT MAKES <br />CONTACT. <br />4. ALL LATERAL BRACING, AS MAY BE REQUIRED BY DESIGN TO REDUCE BUCKLING LENGTH <br />OF INDIVIDUAL TRUSS MEMBERS, SHALL BE A PART OF THE LIGHT GAUGE STEEL ROOF <br />TRUSS DESIGN PACKAGE. ALL REQUIRED TRUSS MEMBER BRACING, INCLUDING' BRACING <br />MEMBER SIZE, EXACT LOCATION, AND CONNECTION REQUIREMENTS, SHALL BE 6LEARLY <br />INDICATED ON THE SHOP FABRICATION AND ERECTION DRAWINGS PREPARED BY THE <br />�-ABRICATOR*S ENGINEERING DEPARTMENT. <br />5 ALL HOR17ONTAL BRACING SHAI. L BE STIFFENED AT EACH END OF THE BUT[ DING AND AT <br />20'-O" O.C. IN BETWEEN WITH DIAGONAL "CROSS"BRACING EXTENDED TO A DIAPHRAGM <br />PARALLEL TO THE HORIZONTAL BRACING. <br />6. ALL TRUSS TOP CHORDS SHALL BE CONTINUOUSLY BRACED BY THE ROOF DECKING. <br />7. ROOF TRUSSES SHALL BE DESIGNED FOR ALL UPLIFT FORCES REQUIRED BY <br />A. ASCE 7-10 <br />B. BASE WIND VELOCITY V(uft) = 148 mph, V(asd) = I 15 mph <br />C. EXPOSURE CATEGORY "B" <br />D. BUILDING RISK CATEGORY � CATEGORY IV (FIRE STATION) <br />E. INTERNAL PRESSURE COEFFICIENT = +/-.1 8 <br />DUE CONSIDERATION SHALL BE GIVEN TO THE POSSIBILITY OF BECOMING COMPRESSION <br />MEMBERS UNDER MAXIMUM DESIGN WIND VELOCITY CONDITIONS. ALL TRUSS BOTTOM <br />CHORDS SHALL BE BRACED AT INTERVALS NOT EXCEEDING 4'-O" O.C., UNLESS <br />CALCULATIONS PERFORMED BY THE TRUSS FABRICATORS STRUCTURAL ENGINEER <br />INDICATE OTHERWISE. ALL REQUIRED BOTTOM CHORD MEMBER BRACING REQUIREMENTS <br />SHALL BE CLEARLY INDICATED ON THE SHOP FABRICATION AND ERECTION DRAWINGS <br />PREPARED UNDER THE RESPONSIBLE CHARGE OF THE FABRICATOR'S DELEGATED <br />"SPECIALTY'STRUCTURAL ENGINEER. <br />8. SUCH TEMPORARY ERECTION BRACING, AS IS REQUIRED TO MAINTAIN LATERAL STABILITY <br />& STRUCTURAL INTEGRITY OF THE ROOF TRUSS SYSTEM AND SITE SAFETY DURING <br />ERECTION 15 THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND HIS <br />LIGHT GAUGE COLD FORMED STEEL FRAMING DESIGN AND SHOP DRAWINGS: <br />THE STRUCTURAL ANALYSIS, STRUCTURAL DESIGN, DETAILING AND CONNECTIONS OF ALL <br />LIGHT GAUGE COLD FORMED STEEL FRAMING SHALL BE THE RESPONSIBILITY OF THE <br />FABRICATOR/EREC70R. THE INFORMATION CONTAINED IN THE STRUCTURAL CONTRACT <br />DOCUMENTS, WHICH COVERS STRUCTURAL LIGHT GAUGE COLD FORMED MEMBERS IS <br />TO BE CONSIDERED AS A PERFORMANCE SPECIFICATION. <br />1- THE DESIGN SHALL BE PERFORMED BY A DELEGATED "SPECIALTY'STRUC I URAL ENGINEER <br />HOLDING VALID CURRENT REGISTRATION IN THE STATE Or- FLORIDA, WHO SHALL BE <br />RETAINED BY THE CONTRACTOR AND WHO SHALL BE THE ENGINEER OF RECORD FOR <br />THOSE PORTIONS OF THE STRUCTURE (THOSE STRUCTURAL ELEMENTS) WHICH HE/SHE <br />DESIGNED, NOTE THAT A "SPECIALTY ENGINEERING" DESIGN/CONSTRUCTION DOCUMENT <br />PACKAGE IS REQUIRED, NOT A "TECHNICAL INFORMATION" PACKAGE. <br />2. SUCH ELEMENTS SHALL BE DESIGNED PURSUANT TO THE "COMPONENTS AND CLADDING" <br />PROVISIONS OF ASCE 7-05, <br />A. BASE WIND SPEED� V(ult) = 148 mph, V(asd) = 11 5 mph <br />B. EXPOSURE CATEGORY "B" <br />C. BUILDING RISK CATEGORY = CATEGORY IV (FIRE STATION) <br />0. INTERNAL PRESSURE COEFFICIENT = +/-.18 <br />E. ENCLOSED BUILDING <br />3. THE DELEGATED SPECIALTY STRUCTURAL ENGINEER SHALL PREPARE CALCULATIONS WITH <br />RFFFRENCETOTHE 2010 FOITION OFTHF FLORIDA BUILDING CODEAND ALL APPROPRIATE <br />DEFLECTION AND SERVICEABILITY CRITERIA. CALCULATIONS SHALL CLEARLY STATE ALL <br />ASSUMED DESIGN LOADING. DEFLECTION SHALL NOT EXCEED THE SPAN DIVIDED BY 360, <br />4. DESIGN/SHOP DRAWINGS FOR SUCH ELEMENTS SHALL BE SUBMITTED TO THE ARCHITECT <br />FOR REVIEW AND SHALL INCLUDE ALL DESIGN CRITERIA, COMPLETE CALCULATIONS, <br />REACTIONS AND TYPICAL CONNECTIONS AT ALL CONNECTION POINTS, ETC. DESIGNISHor <br />DRAWINGS SHALL PROVIDE COMPLETE INFORMATION ON SWDS, TRACK, JOISTS, <br />BRIDGING, BRACING: STRAPS, CONNECTIONS, ETC., NECESSARY TO ASSEMBLE THE <br />COMPONENTS INTO ASYSTEM HAVING APPROPIRIATFSTRUCTURAL INTEGRITY. ALL <br />MEMBERS SHALL BE SPECIFIED IN THE SUBMITTAL. WHICH SHALL INCLUDE, <br />MANUFACTURER AND REQUIRED STRUCTURAL SECTION PROPERTIES. DETAILS OF ALL <br />CONNECTIONS SHAI I BE INCLUDED. ALL C ,ONNECTIONS BETWEEN LIGHT GAUGE COLD <br />FORMED STRUCTURAL MEMBERS SHALL BE MADE BY WELDING, UNLESS OTHERWISE <br />NOTED. <br />5. DESIGN/SHOP DRAWINGS AND CALCULATIONS SHALL BE SIGNED SEALED AND DATED BY <br />THE DELEGATED "SPECIALTY" STRUCTURAL ENGINEER WHO WAS IN RESPONSIBLE CHARGE <br />OF THE DESIGN. <br />(NOTE: THE SPECIALTY ENGINEER MAY, AFTER RECEIVING APPROVAL FROM THE <br />ARCHITECT AND STRUCTURAL ENGINEER OF RECORD, MODIFY ANY DETAIL THAT HE <br />DEEMS APPROPRIATE DURING HIS DESIGN AND DETAILING PROCESS.) <br />6. ALL LIGHT GAGE STEEL STRUCTURAL MEMBERS SHALL BE GALVANIZED AND SHALL BE <br />FORMED FROM STEEL MEETING THE REQUIREMENTS OF A.S.T.M. A-653, GRADE I'D" (16 GAGE <br />AND THICKER MATERIAL WITH A MINIMUM'YIELD STRENGTH OF 50 KSI), AND A.S.T.M. A-653. <br />GRADE "B" (18 GAGE AND THINNER MATERIAL WITH A MINIMUM YIELD STRENGTH OF 33 KSI). <br />THE GENERAL CONTRACTOR SHALL REVIEW ANDAPPROVE ROOF TRUSS SHOP DRAWINGS FOR <br />SIZE SHAPE, DIMENSIONING . AND LAYOUT PRIOR TO SUBMITTAL TO THE ENGINEERS OF <br />RECORD FOR REVIEW! <br />PREENGINEERED PREFABRICATED LIGHT GAGE S I EEL ROOF TRUSSES ("TRUSSTEEL" BY ALPINE <br />ENGINEERED PRODUCTS INC. OR ULTRASPAN BY AEGIS METAL FRAMING) SHALL BE DESIGNED <br />IN ACCORDANCE WITH THE LATEST EDITION(S', OF THE FOLLOWING PUBLICATIONS BY THE <br />AMERICAN IRON 8 STEEL INSTITUTE <br />A. "NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD FORMED STEEL <br />STRUCTURAL MEMBERS" - ANSI/AISI/COSIS1 00-07/S2-10,2007 EDITION W/ 2010 <br />SUPPLEMENT. <br />B. "NORTH AMERICAN STANDARD FOR COLD FORMED STEEL FRAMING - GENERAL <br />PROVISIONS" - ANSI/AISI/COFS/S200-07.2007 EDITION. <br />C NORTH AMERICAN STANDARD FOR COLD -FORMED STEEL FRAMING - TRUSS DESIGN: <br />ANSI/AISI/COFS/S214-07/S2-08,2007 EDITION INCLUDING THE 2008 SUPPLEMENT. <br />D AISI/COFS - PRACTICE GUIDE - CF06-1. CODE OF STANDARD PRACTICE FOR COLD - <br />FORMED STEEL STRUCTURAL FRAMING, 2006. <br />E. ASTM A 370-09 -STANDARD TEST METHODS AND DEFINITIONS FOR MECHANICAL <br />TESTING OF STEEL PRODUCTS; 2009. <br />F. ASTM A 500-03A - STANDARD SPECIFICATION FOR COLD -FORMED WELDED AND <br />SEAMLESS CARBON STEEL STRUCTURAL TUBING IN ROUNDS AND SHAPES; 2003. <br />G. ASTM A 653-09 - STANDARD SPECIFICATION FOR STEEL SHEET, ZINC -COATED <br />(GALVANIZED) OR ZINC -IRON ALLOY -COATED (GALVANNEALED) BY THE HOT -DIP <br />PROCESS; 2009. <br />H. CFSBCSI - COLD -FORMED STEEL BUILDING COMPONENTS SAFETY INFORMATION; COLD - <br />FORMED STEEL COUNCIL (CFSC); 2008 EDITION WITH CFSB3 SUMMARY SHEET INSERT <br />1. CFSEI TECHNICAL NOTE 551 D - DESIGN GUICE FOR CONSTRUCTION BRACING OF COLD - <br />FORMED STEEL TRUSSES', COLD -FORMED S-EEL ENGINEERS INSTITUTE,- FEBRUARY <br />1997. <br />J. CFSEI TECHNICAL NOTE 551 E - DESIGN GUIDE FOR PERMANENT BRACING OF COLD - <br />FORMED STEEL TRUSSES' COLD -FORMED STEEL ENGINEERS INSTITUTE- FFBRUARY <br />1998. <br />1. SHOP DRAWINGS SHALL BEAR THE SEAL AND SIGNATURE OF THE REGISTERED <br />PROFESSIONAL (STRUCTURAL) ENGINEER RESPONSIBLE FOR THE STRUCTURAL <br />ANALYSIS AND DESIGN OF THE INDIVIDUAL ROOF TRUSSES AND THE ROOF TRUSS <br />SYSTEM. THIS ENGI NEER SHALL HOLD CURRENT VALID REGISTRATION ASA <br />PROFESSIONAL ENGINEER IN THE STATE OF FLORIDA. INDIVIDUAL TRUSS DESIGN <br />SHEETS SHALL BE FULLY COORDINATED WITH AND KEYED TO THF ROOF TRUSS <br />FRAMING PLAN, WHICH SHALL LIKEWISE BE SIGNED AND SEALED. IF THIS <br />REQUIREMENT IS NOT FULFILLED IN DETAIL. THE SUBMITTAL WILL BE REJECTED AND <br />RETURNED AS INADEQUATEI. <br />2. REQUIRED GENERAL INFORMATION: <br />A. ERECTION PLAN: SHOWING DIMENSIONED LOCATION AND TRUSS <br />IDENTIFICATION. <br />B. BEARING DETAILS: SHOWING BEARING LENGTH, WIDTH AND DEPTH (INDICATING <br />CONFORMANCE TO DESIGN CALCULATIONS). <br />C. DESIGN LOADS: ALL DEAD, LIVE & WIND LOADS SHALL BE SHOWN ON THE <br />ERECTION PLAN OR TRUSS ELEVATION INDICATING CONFORMANCE TO TRUSS <br />CALCULATIONS AND ORIGINAL DESIGN CRITERIA. TRUSS SYSTEM DESIGNER <br />SHALL GIVE FULL CONSIDERATION TO THE FOLLOWING: <br />1. TRUSS DESIGN ENGINEER SHALL BE PROVIDED WITH A COMPLETE SET <br />OF BOTH ARCHITECTURAL AND STRUCTURAL CONTRACT DOCUMENTS <br />PRIOR TO BEGINNING DESIGN OF THE ROOF TRUSS SYSTEM. <br />2. TRUSS SYSTEM SHALL BE DESIGNED AS "COMPONENTS AND CLADDING" <br />AS DEFINED BY THE APPLICABLE BUILDING CODE WITH DUE <br />CONSIDERATION OF, "ENCLOSED", "PARTIALLY ENCLOSED" AND <br />"COMPLETELY OPEN" PORTIONS OF THE STRUCTURE AND USE OF <br />APPROPRIATE GUST RESPONSE & SHAPE FACTORS. <br />D, ALL PERMANENT BRACING AND BRIDGING: SHOW TOP CHORD, BOTTOM CHORD, <br />AND WEB MEMBER BRACING ON ERECTION LAYOUT PLAN AND TRUSS <br />ELEVATIONS. SUPPLIER AND INSTALLER OF THIS BRACING SHALL ALSO BE <br />INDICATED. <br />E. TRUSS DIMENSION: SHOW DEPTH, SPAN, BEARING, HEIGHT AND SLOPES AT ALL <br />CRITICAL POINTS. <br />3. INFORMATION THAT SHALL BE THE RESPONSIBILITY OF THE FABRICATOR AND TRUSS <br />DESIGNER AND SHALL BE COMPLETELY DETAILED WITHIN THE SHOP DRAWING <br />SUBMITTAL. <br />NOTE ALL LIGHT GAGETRUSSES SHALL BE PREFABRICATED IN THE SHOPAND <br />SHIPPED TO THE JOBSITE. JOBSITE FABRICATION OF TRUSSES WILL NOT BE <br />PERMITTED. SHOULD FIELD SPLICING OF TRUSSES BE REQUIRED, THE SPLICE <br />HARDWARE AND FASTENERS SHALL BE SHOP FABRICATED AND SHIPPED TO <br />THE JOBSITE AND THE TRUSS MANUFACTURER SHALL SUPERVISE THE <br />ASSEMBLY OF THE JOBSITE SPLICES. <br />A. MEMBER DESIGN: INCLUDING WEB CONFIGURATION, MEMBER SIZE, GRADE, <br />GAGE AND FINISH (G-60 GALVANIZATION MINIMUM) OF LIGHT GAGE COLD <br />FORMED FRAMING MEMBERS, FABRICATED SPLICES AND MEMBER BRACING <br />REQUIRED BYTRUSS DESIGN. <br />B. INTERIOR CONNECTION: DESIGN AND SHOW DETAIL OF WEB AND CHORD <br />CONNECTIONS, CONNECTION PLATES AND PLATE CAPACITIES. <br />C. ERECTION PLANi SHOW SPACING AND LAYOUT OF ANY TEMPORARY BRACING <br />REQUIRED FOR ERECTION. <br />D. STRUCTURAL DESIGN OF TRUSSES: SUBMIT COMPLETE TRUSS CALCULATIONS <br />AND OBTAIN ALL APPROVALS NECESSARY FOR CONFORMANCE TO BUILDING <br />CODE. VERIFY SUBMITTAL AND APPROVAL BY SENDING A COPY TO THE <br />ENGINEER OF RECORD. <br />E. ERECTION. FURNISH TRUSS ERECTOR WITH ALL DATA NECESSARY FOR <br />PROPER INSTALLATION. <br />F. INDICATE GRAVITY LOAD REACTIONS AND UPLIFT REACTIONS AT ALL SUPPORT <br />POINTS FOR EACH SPECIFIC TRUSS TYPE. <br />G. CONNECTION HARDWARE: SUBMIT REQUIRED CAPACITY AND SUGGESTED <br />MANUFACTURER AND MODEL OF ANY REQUIRED PRE-ENGINEERED <br />PREFABRICATED HARDWARE. (SPECIFY NUMBER OF SCREWS OR BOLTS AND <br />SPLICE PLATES REQUIRED TO MAKE PROPER CONNECTION). <br />NOTE: ALL CONNECTIONS BETWEEN PRE-ENGINEERED PREFABRICATED <br />TRUSSES SHALL BE THE RESPONSIBILITY OF THE TRUSS <br />DESIGNER/FABRICATOR (BECAUSE OF THE EFFECT OF THE <br />CONNECTION FASTENINGS ON THE TRUSS DESIGN). <br />4. MINIMUM ROOF TRUSS DESIGN LOADS: <br />A. ROOF LIVE: 20 PSF. <br />B. TOP CHORD DEAD LOAD: 15 PSF. <br />C. BOTTOM CHORD DEAD LOAD: 10 PSF. <br />D. WIND FORCES: DESIGN FOR THE MAXIMUM FORCES. <br />(INCLUDING UPLIFT), REQUIRED BY THE 2010 EDITION <br />OF THE FLORIDA BUILDING CODE. <br />1 . DESIGN WIND SPEEC. V(Ult) = 148 mph, V(asd) = 1 15 mph <br />2. EXPOSURE CATEGORY = EXPOSURE "B" <br />3. INTERNAL PRESSURE COEFFICIENT= (+/-).18 <br />4. ENCLOSED BUILDING <br />5. BUILDING RISK CATEGORY = CATEGORY IV (FIRE STATION) <br />NOTE: NET UPLIFT SHALL BE CALCULATED USING A DEAD LOAD OF NOT TO <br />EXCEED 7 PSF TOTAL FOR COMBINED TOP AND BOTTOM CHORD. <br />E. ADDITIONAL FORCES: AS INDICATED BY THE DRAWINGS. <br />WLEDGEABLIF PROFESSIONAL <br />SPECIALTY ENGINEERING WORK SHALL BE PERFORMED BY KNCHALL HOLD CURRENT VALID <br />ENGINEERS WHO'S DISCIPLINE SHALL BE STRUCTURAL. THEYENGINEERS, THEGENERAL <br />REGISTRATION IN THE STATE OF FLORIDA AS PROFESSIONAL ESED THAT THE ARCHITECT AND <br />CONTRACTOR AND STRUCTURAL SUBCONTRACTORS ARE ADVi 0 APPROVE OR DISAPPROVE <br />STRUCTURAL ENGINEER OF RECORD SHALL HAVE THE RIGHT T <br />ANY INDIVIDUAL SPECIALTY ENGINEER, WITHOUT INCURRING 0YADDIT IONAL COSTS OR <br />LIABILITY TO THE OWNER, THE ARCHITECT OF RECORD OR THF ENGINEER OF RECORD. IT <br />WOULD BE PRUDENT FOR THE G.C. TO SUBMIT THE QUALIFICATIONS OF THE PROPOSED <br />"SPECIALTY" STRUCTURAL ENGINEER(S) TO THE STRUCTURAL ENGINEER OF RECORD, PRIOR <br />TO FORMALLY CONTRACTING FOR SUCH SERVICES. THE"SPECIALTY'STRUCTURAL ENGINEER <br />IS CAUTIONED THAT ALL SUBMITTALS MUST BE PREPARED AND SUBMITTED IN ACCORDANCE <br />WITH THE GUIDELINES PUBLISHED BY THE FLORIDA DEPARTMENT OF PROFESSIONAL <br />REGULATION, BOARD OF PROFESSIONAL ENGINEERS IN RULE NUMBER 211-1-19.001, "RULE AND <br />STATEMENTS ON RESPONSIBILITY OF PROFESSIONAL ENGINEERS". <br />1. IT 13 THE DELEGATED SPECIALTY ENGINEERS RESPONSIBILITY TO REVIEW THE ENGINEER <br />OF RECORD'S WRITTEN ENGINEERING CRITERIA REGARDING THE SPECIALTY ENGINEERING <br />REQUIREMENTS IN ORDER TO DETERMINE THE SCOPE OF WORK OF THE SPECIALTY <br />ENGINEERING. <br />2. THE DELEGATED ENGINEERING DOCUMENT SUBMITTALS SHALL COMPLYWITH THE <br />WRITTEN ENGINEERING REQUIREMENTS RECEIVED FROM THE ENGINEER OF RECORD. THE <br />DELEGATED ENGINEERING SUBMITTAL SHALL INCLUDE THE PROJECT NAME AND THE <br />DESIGN CRITERIA USED IN PREPARING THE SUBMITTAL. <br />3, IF THE DELEGATED ENGINEER DETERMINES THERE ARE DETAILS, FEATURES OR <br />UNANTICIPATED PROJECT LIMITS WHICH CONFLICT WITH THE WRITTEN ENGINEERING <br />REQUIREMENTS PROVIDED BY THE ENGINEER OF RECORD, THE DELEGATED ENGINEER <br />SHALL IMMEDIATELY CONTACT THE ENGINEER OF RECORD TO RESOLVE THE CONFLICT. <br />4 THE DELEGATFD ENGINEER SHALL FORWARD THE DFLEGATED ENGINEERING DOCUMENTS <br />TO THE ENGINEER OF RECORD FOR REVIEW. ALL DELEGATED ENGINEERING DOCUMENTS <br />SHALL BE SIGNED AND SEALED BYTHE DELEGATED ENGINEER AND SHALL INCLUDE THE <br />FOLLOWING: <br />A. FRAMING PLANS, DETAILS. CONNECTIONS, ETC. AS REQUIRED TO DEFINING THE <br />CONFIGURATION AND STRUCTURAL CAPACITY OF STRUCTURAL COMPONENTS AND/OR <br />THEIR ASSEMBLY INTO STRUCTURAL SYSTEM. <br />B COMPUTATIONS HAVING ADEQUATE DETAIL FOR THE ENGINFER OF RECORD TO <br />DETERMINE THAT THE SUBMITTAL WAS FULLY ENGINEERED AND DOCUMENTED. NO <br />DETAILED REVIEW OF THE DELEGATED SPECIALTY ENGINEERING CALCULATIONS WILL <br />BE PROVIDED BY THE E.O.R. <br />. <br />INSTRUCTIONS FOR INSTALLATION OF DRILLED IN DOWELS AND ANCHORS: <br />1 . SEE DRAWINGS FOR SIZE, LENGTH TYPE AND SPACING OF ANCHORS REQUIRED. <br />NOTE: DRILLED IN ANCHORS WILL NOT BE AN ACCEPTABLE ALTERNATIVE TO <br />SPECIFIED EMBEDDED ANCHORS (ANCHOR BOLTS, HEADED STUDS, ETC.) <br />2. CLOSELY FOLLOW ANCHOR INSTALLATION INSTRUCTIONS PROVIDED WITH TI IE PRODUCT, <br />BY THE MANUFACTURER. THIS INFORMATION INCLUDES DRILL TYPE AND DIAMETER FOR A <br />GIVEN ANCHOR OR DOWEL SIZE, CLEANING INSTRUCTIONS FOR THE HOLE (REMOVAL OF <br />DRILL DUST OR SLURRY BY COMPRESSED AIR AND WATER), AND MATERIAL INSTALLATION <br />AND QUANTITY FOR A GIVEN APPLICATION. <br />3. REGARDING "EPDXY" ANCHORS. PROVIDE ADHESIVES WHICH ARE MANUFACTURED AND <br />DISTRIBUTED AS TWO PART (BASEMARDENER) CARTRIDGE INSTALLED WITH DOUBLE <br />PLUNGER CAULKING GUN WITH AUTOMATIC MIXING NOZZLE SUPPLIED BYTHE <br />HALL MEET THE MINIMUM REQUIREMENTS OF ASTM C 881 <br />SPECIFICATION FOR TYPE 1, 11: IV, V, GRADE 3, CLASS B, C AND D AND MUST DEVELOP A <br />MINIMUM 12,650 PSI COMPRESSIVE YIELD STRENGTH AFTER 7 DAY CURE. <br />PREFERABLE MANUFACTURERS AREAS FOLLOW <br />A. SIMPSON STRONG TIE "SE-P'EPDXY <br />B. HILTI "HY-150" <br />OTHER MANUFACTURER'S PRODUCTS WILL NOT BE CONSIDERED UNLESS ALLOWABLE <br />LOAD DATA, BASED UPON TESTING LABORATCRY RESULTS, ARE SUBMITTED FOR REVIEW <br />AND CONSIDERATION. OUR PREFERENCE FOR I HESE PRODUCT 8 IS BASEL) UPON'THE <br />AUTOMATIC MIXING OF THE TWO PARTS PRIOR TO DISCHARGE FROM THE GUN AND THEIR <br />L ITERATURE WHICH REPRESENTS A CONSIDERABLE AMOUNT OF RACK UP TESTING <br />4. GENERALLY, ANCHOR DRILLED IN DEPTHS SHOULD NOT BE LESS THAN 8 INCHES <br />WHENEVER POSSIBLE. WHEN ANCHORS ARE INSTALLED THROUGH BRICK AND/OR VENEER, <br />THE ANCHOR SHALL PENETRATE INTO THE BACK UP STRUCTURAL MASONRY OR CONCRETE <br />AT LEAST 6 INCHES. <br />6. WHERE DRILLED IN EXPANSION ANCHORS ARE REQUESTED IN I IEU OF CAST IN PLACE <br />ANCHORS, THEY MUST BE REQUESTED IN WRITING BEFORE INSTALLATION AND ADEQUATE <br />MANUFACTURER'S LITERATURE MUST BE SUBMITTED AS DOCUMENTATION. THE <br />SUBSTITUTION OF EXPANSION ANCHORS MAY OR MAY NOT BE ACCEPTED DEPENDING <br />UPON THE LOADING AND SPECIFIC APPLICATION, DO NOT SUBMIT SLEEVE ANCHORS. ALL <br />EXPANSION ANCHORS MUST BE WEDGE ANCHORS. GENERALLY, IF EXPANSION ANCHORS <br />ARE PERMITTED THEY WILL BE REQUIRED TO BE AT LEAST ONE SIZE LARGER AND MORE <br />CLOSELY SPACED THAN THE SPECIFIED EMBEDDED ANCHORS. <br />6. MASONRY SCREWS SHALL BE 1/4" DIAMETER 1 1/2" MINIMUM EMBEDMENT INSTALLED I N <br />DRILLED HOLES USING AN APPROPRIATE BIT DIAMETER. SCREWS SHALL BE MADE FROM <br />TEN HUNDRED SERIFS COLE) ROLLED STEEL AND SHALL BE FLUOROCARBON COATED <br />PROVIDE "TITAN" SCREWS BY SIMPSON STRONG TIE OR EQUAL, <br />7. ALL BOLTS AND SCREWS TO BE HOT -DIPPED, GALVANIZED OR STAINLESS STEEL. <br />TYPICAL FOUNDATION PLAN NOTES & LEGEND: <br />1. (C.J.) INDICATES 318 INCH WIDE MASONRY WALL CRACK CONTROL JOINT. EXTENDC.J. <br />FROM TOP OF FOUNDATION TO TOP OF MASONRYWALL. ALL TIE BEAM <br />LONGITUDINAL REINFORCING SHALL RUN CONTINUOUS THROUGH (ACROSS) <br />JOINT. SEE DETAILS ON SHEETS SD1 PROVIDE C.J.'s WHERE INDICATED AND IN <br />ADDITION, WHERE NOT SPECIFICALLY INDICATED ON PLANS, PROVIDE <br />CONTROL JOINTS IN INTERIOR WALLS AT SPACINGS NOT TO EXCEED 26 FT. O.C. <br />2. (e) INDICATES SINGLE VERTICAL REINFORCING BAR IN A SINGLE SOLID GROUTED <br />MASONRY WALL CELL (SEE PLANS FOR SPECIFIC BAR SIZE & LOCATION) <br />REINFORCING SHALL ORIGINATE IN THE FOUNDATION WITH A STANDARD ACT 90 <br />DEGREE HOOK HAVING ADEQUATE LENGTH ABOVE THE TOP OF THE FOOTING TO <br />PROVIDE FOR A FULL TENSION LAP. THE CONTRACTOR IS CAUTIONED TO COORDINATE <br />POUR LENGTH AND SCHEDULE WITH THE REBAR DETAILER SUCH THAT FULL TENSION <br />LAPS ARE PROVIDED AT ALL VERTICAL WALL REINFORCING LAP SPLICES. VERTICAL <br />WALL REINFORCING SHALL EXTEND TO AND TERMINATE IN THE TIE BEAM AT THE TOP <br />OF THE MASONRY WALL WITH A STANDARD ACT 90 DEGREE HOOK BAR. SEEPLAN <br />DETAILS AND SHEET SID 1 FOR LOCATION OF BAR PLACEMENT WITHIN THE CELL(S). <br />NOTE.' UNLESS OTHERWISE NOTED OR DETAILED, VERTICAL WALL REINFORCING IN <br />WALLS BETWEEN LINTEL BEAMS AND TIE BEAMS SHALL NOT BE LESS THAN <br />THAI SHOWN TYPICALLY IN SOLI D WALL BEYOND MO. <br />3. (m) INDICATES DOUBLE VERTICAL REINFORCING BARS INA SINGLE SOLID GROUTED <br />MASONRY WALL CELL (SEE PLANS FOR SPECIFIC BAR SIZE& LOCATION) ALL <br />PROVISIONS OF NOTE (2.), ABOVE, SHALL APPLY. <br />4. (o) INDICATES VERTICAL MASONRYWALL REINFORCING INTERRUPTED BY MASONRY <br />OPENING. PROVIDE REINFORCING BOTH ABOVE AND BELOW M.O. <br />5. (VVFXX) INDICATES WALL (OR CONTINUOUS STRIP TYPE) FOOTING. "XX"INDICATES <br />FOOTING SIZE IN INCHES. <br />6. (C FXX) INDICATES COLUMN (OR RECTANGULAR PAD TYPE) FOOTING. "XX"INDICATES <br />FOOTING SIZE IN INCHES <br />6 <br />< ��,� <br />a: c< �] <br />z 15_� <br />w !R <br />zo Nil <br />z 2 :9 <br />� <br />�_ 112 <br />-0 � <br />a < <br />cd I - <br />� 15 1 <br />cc 16 . <br />§1 <br />V I 1 2 <br />to I Im � <br />W R 11­_ <br />:� I cv) I_: ed <br />0) 110 0) 1 31: <br />TO THE BEST OF MY KNOWLEDGE, THE <br />PLANS AND SPECIFICATIONS COMPLY NTH <br />THE CURRENT MINIMUM BUILDING CODES. <br />,1._1111_1 I IIIIIIIIIIIIIIIIIIIIvIIIIIIIIr P.E. <br />P411IIIIIIIIIIIIIIIIIIIIIIIIII11 <br />- <br />w ic" " -�: E, t i W W Eq,, �. Z. <br />- ""' I <br />V - t S <br />1�0,%t wlf� <br />%-,A .- <br />110v -I � <br />P.E.#20683 <br />WEBER AND TINNEN, P.A. <br />CITY OF ZEPHYRHILLS <br />RENOVATION <br />OF <br />FIRE RESCUE <br />STATION NO. 2 <br />CONSTRUCTION <br />0 12-07-2012 N <br />N CB+A #1 202 0 <br />N 0 <br />BELFSKY <br />+ <br />ARROYO <br />ARCHITECTS <br />800 SECOND AVENUE SOUTH <br />ST. PETERSBURG, FL 33701 <br />(727) 823-0675 <br />0 E <br />NOTES & SPECIFICATIONS <br />(0)THEOE DRAWINGS & THEIR CONTENTS ARE THE SOLE PROPERTY OF WEBER & TINNEN, P,A. STRUCTURAL ENGINEER$. SCALE: AS NOTED SN-2 <br />!::/ <br />R ANY PORTIONS 10 BY CONTRACT ONLY. UNAUTHORIZED USE WILL BE PROSECUTED. 0 0 <br />, <br />11frn 17-710111 <br />