Laserfiche WebLink
�y MITT - __ <br />Window and Door Schedule <br />No. <br />Type <br />Size <br />Notes <br />I <br />Door or Window <br />Manufacturer Name <br />1 <br />Insulated exterior door <br />36" x 80" <br />N/A <br />Therma - Tru Corporation <br />2 <br />Insulated exterior door <br />32'9 X 8095 <br />N/A <br />Therma - Tru Corporation <br />3 <br />Single hung window <br />SH 23 <br />NIA <br />PGT industries <br />4 1 <br />Single hung window <br />SH 24 <br />WA <br />PGT industries <br />5 <br />Single hung window <br />SH 34 <br />WA <br />PGT industries <br />6 <br />Single hung window <br />SH 35 <br />Now fire egress window <br />PGT industries <br />7 <br />Interior hollow core door <br />18" X 80" <br />N/A <br />N/A <br />8 <br />Interior hollow core door <br />30" x 80" <br />NIA <br />N/A <br />9 <br />Interior hollow core door <br />32" x 80" <br />NIA <br />NIA <br />10 <br />Interior hollow core bi - fold <br />door <br />36" x 8(Y' <br />NIA <br />N/A <br />11 <br />Interior hollow core bi - fold <br />door <br />48" x 80" <br />I <br />NIA <br />I <br />N/A <br />I <br />Note: <br />1. ALL EXTERIOR DOORS AND WINDOWS SPECIFIED ARE "IMPACT RESISTANT". <br />2. PROTECTION OF OPENINGS SHALL CONFORM AND MEET REQUIREMENTS ASSET FORTH IN FBC 51h EDITION (2014) <br />RESIDENTIAL, SECTION R 301.2.1.2 <br />3. Any products that are substituted, must meet or exceed products specified. Contractor "MUST" provide data to building inspector at <br />time of inspection. <br />4. Contractor "MUST" (double check) and field verify all existing openings then coordinate with manufacture before purchasing any doors <br />and / or windows. Daniel M. Ossman Drafting Service, Inc. "IS NOT" responsible for any errors in sizes, in the door / window schedule. <br />Match existing vinyl siding, over a water resistive <br />"Tyvek" vapor barrier, over 1/2" cd-x plywood <br />sheathing that is nailed with 10d x 1 1/2" nails @ 6" <br />o.c. edges and 12" field, over 2 x 4 exterior wood <br />studs @ 16" o.c. with R - 13 insulation between and <br />finished with 1/2" drywall on the inside. Water <br />resistive barrier in accordance with Section R703.6.3, <br />of the FBC 5th Edition 2014 Residential. <br />N <br />04 <br />4 <br />(0, C, -- 12, F_ 5 5 <br />(� E41ZE-5S <br />PROPOSED FLOOR PLAN LAYOUT <br />12 <br />.4 "5 - 0, <br />Q <br />0 <br />I <br />I. <br />LO <br />CID <br />N <br />Existing concrete block wall to remain. <br />Existing 2 x frame wall to remain <br />New 8" concrete block wall. Finish the interior with 1/2" <br />drywall over min. R - 6 insulation over RT furring strips <br />For all "exterior walls" use 2 x 4 studs @ 16" o.c. and <br />finish with 1/2" drywall over min. R -13 insulation. For all <br />"interior walls" use 2 x 4 studs @ 24" o.c. and finish with <br />1/2" drywall. Provide min R - 13 insulation for all adjacent <br />walls or any other locations that are required by code. <br />Note: At all plumbing walls use 2 x 6 studs to allow for <br />ventilation plumbing stacks. <br />Closet maid ventilated shelving <br />NOTE: Alteration as described herein and shall <br />be performed are designated as "level 2" per <br />section 801, of the Florida Building Code 5th <br />Edition 2014 Existing Building Code Book. <br />NOTE: Repairs, alterations, additions, changes in <br />in occupancy and relocated buildings must comply <br />with all applicable requirements per section 101.. <br />of the Florida Building Code 5th Edition 2014 <br />Existing Building Code Book. <br />It is the responsible of the General Contractor to make a field <br />inspection to verify all existing field conditions and measurements <br />with proposed plans for accuracy, before distributing plans to any <br />and all trades. General Contractor will be held liable if these <br />inaccuracies are "NOT" submitted in writing to Daniel M. Ossman <br />Drafting Service, Inc. before the distribution of plans- Daniel M. <br />Ossman Drafting Service, Inc. "WILL NOT" be held liable for any <br />inaccuracies in dimensions with existing field conditions or other <br />trades on proposed plans. <br />All exterior masonry and / or frame perimeter walls <br />are to be considered shearwall segments, except at <br />door / window openings and wall lengths less than <br />2'- 8" in length. <br />State of Florida Energy calculation form overrides <br />any insulation R - values shown on plans. Contractor <br />"MUST" coordinate and verify with mechanical <br />contractor before the installation of insulation <br />and mechanical equipment. <br />a <br />725 s/f Existing heated living area <br />.78 Existing heated area to be demo <br />647 sK Existing heated living area after demo <br />293 aff Proposed heated living area addition <br />940 s/f Total square footage heated area under roof <br />32 s/f Proposed covered front porch addition <br />EXISTING FLOOR PLAN LAYOUT <br />REVISIONS <br />N0 DAlf D[:SCRIP-TION <br />VD <br />0 <br />E <br />Ix <br />en <br />Z <br />(X <br />8 <br />E <br />F <br />N <br />rA <br />(X <br />% <br />0 <br />-0 W <br />CD Co <br />a) <br />aca� C)m <br />IT 0 <br />C CU C T.- r- to <br />(D - 0 (0 W cl) <br />U C1-J < m <br />a) C <br />(D 0 72 <br />> (D <br />ce) -0 0 <br />- LU u- <br />a) U_ <br />Cl) , M <br />U*) 0 CL <br />E rof -c a) 1? E <br />-0 _E T <br />0 F�; <br />0 %_ co <br />< <br />C <br />0 E c 7 <br />Co --a <br />E CL — 0 0 <br />E J u) m <br />42 o' o m hi :3 10 <br />0 ; <br />00 cu , <br />2 co <br />0 <br />0 'D C) <br />a) Z a)— M Uj a) <br />L;-- U- -C C <br />�E 0 <br />cc 4) -C <br />0 o 2: C,4 CL <br />U) <br />> <br />< <br />CY) <br />CY) <br />Z <br />r. <br />M <br />_0 <br />< <br />wo-or <br />C) <br />L_ <br />0 <br />LL <br />CY) <br />C0 <br />(D <br />(Y) <br />F <br />Z <br />OC) <br />0c) <br />>, <br />Jc <br />0 <br />CY) <br />CL <br />4) <br />N <br />.J <br />Z) <br />00 <br />1 �, N(. <br />381533 10TH AVE <br />DAI L <br />AUGUST 28, 2016 <br />DRAWN <br />Daniel M. Ossman J <br />SHE-, N <br />SCALE-. 1/4" = 1'- 0" <br />SCALE.- 1/4" = 1'- 0" <br />-4 <br />