My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39882 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39882 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 7:58:22 PM
Creation date
2/18/2025 4:22:23 PM
Metadata
Fields
Template:
Building Plans
Street #
39882
Location
Harmon Grove Ct
Contractor
Lennar Homes
Building Plans - Permit #
1756
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES. - <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44"AFF <br />Bathroom 39"AFF <br />Laundry Room 36"AFF <br />Exterior Waterproof 12"AFF <br />Garage - general purpose 44" AFF <br />Range 2"AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done In strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance With LIL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined In LIL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units In <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />LIL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4601.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles In laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be Included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W. <br />WEATHERPROOF DUPLEX OUTLET <br />:k <br />K: F. 1. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I 'r-1h <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />�-o <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />% M, V" <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />FCHI <br />CHIMES (OPTIONAL) <br />�0 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />F0 <br />PUSH BUTTON SWITCH - DOOR BELL <br />@ <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />awl <br />ELECTRIC PANEL <br />mo�-i <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />15OAr2OOA INDOOR <br />PANEL CENTER <br />NEMA I <br />1 50 AMP/ <br />200 AMP <br />n <br />200 amp <br />150 amp <br />copper to lights & outlets <br />copper to 20 amp clas <br />2 copper to WH <br />3 copper to Dryer <br />or 4/0 SER AJu <br />UNDERGROUND <br />POWER CO. FEED <br />INTERSYSTEM 4 Bary Cu Ground <br />BONDING #4 GROUNDING WIRE <br />TERMINATION PER WITH CODE APPROVI <br />NEC 14,250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC, <br />Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER CO. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />WP <br />GFI <br />PATIO <br />WP <br />GF1 <br />DISC <br />EFDAr'l 'I <br />r-7— F <br />0 <br />�- 13: � <br />GF1 d III <br />H.B. <br />KITCHE <br />------------- <br />[ ------- 9.5(f- -.1 <br />i GFI Li <br />9 <br />Z0 <br />DINING ROOM <br />,/PENDANT AS <br />PER SPECS <br />110, <br />ROUGH -IN FOR <br />OPT.CLG.FAN/ <br />LIGHT PRE-WIRE6)A <br />-E <br />FAMILY ROOM <br />r I <br />ivZol <br />VE IFY METER <br />LOCATION WITH <br />BUI -DER <br />VERIFY LOCATION I IRRIGATION <br />f - — — — — — — — L — — — — -- <br />ELECTRICAL PANEL GF1 @ 44" A.F.F. <br />GAR. <br />GFI @ 44" DOOR <br />A.F.F. GFI <br />2 CAR GARAGE <br />IN <br />L------------ <br />GFI @ 44" <br />.. A. F. F. <br />.......... ............................. 7 ........ <br />W �3 <br />FOYER <br />M <br />GF1 <br />FLEX <br />F III — — — — — 49 <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />TO LIGHT <br />AND <br />SWITCH <br />ABOVE <br />T FR Y, <br />oe <br />9 <br />5INK <br />lc4vof <br />KI ofo < <br />Vq/ <br />Vf <br />PLUMBING RISER_ <br />SCALE:NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />\j Mj��IN <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: Y4"=1'-0" <br />CN <br />ca <br />To the best of the Englineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and sea] Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />U1 <br />11 <br />E to <br />c, 8 <br />I <br />U <br />0 <br />C, a <br />u� tu <br />'. <br />0 <br />0 <br />r- I- Lu <br />C-4 0 o� 3i <br />Cl) V <br />r <br />Z <br />-C 0 <br />0 <br />W <br />Cj <br />r— co <br />L& <br />us <br />to Z <br />C&) 0 D 0 <br />W <br />(D <br />< <br />—C <br />R <br />Co <br />4--J <br />u- <br />0 <br />LU <br />V) <br />S <br />C) <br />< <br />r— <br />C") <br />E <br />Z 0 <br />Z <br />0 <br />E <br />OL <br />ro <br />W <br />t <br />ro <br />Z <br />(Q <br />-05 <br />W <br />C3L <br />0 <br />C=) <br />E <br />< <br />CD <br />CID <br />Uj <br />R <br />O!Z <br />2 C:) <br />(0 <br />0 <br />(D <br />Lee. <br />(D <br />0 <br />C) <br />> <br />L) <br />W <br />0 <br />> <br />2 <br />C) <br />(0 <br />C <br />0 <br />r-.. <br />E <br />"CT <br />LO <br />Cal <br />04 <br />0) <br />r- <br />LO <br />X C) <br />0 <br />00 CN <br />00 <br />E <br />C) <br />N <br />Cq <br />0 <br />Z <br />Z <br />C <br />E C:) <br />E <br />M <br />C <br />0 <br />C <br />JOB <br />NO: <br />21-2023 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.