Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />150A/200A INDOOR <br />PANEL CENTER <br />ill� #14 copparto lightS & outlett; <br />,NEMA 1 <br />50 AMP <br />10 #12 copperto 20 amp ckts <br />200 AMP <br />111, #10-2 copper to WH <br />01 010-3 copper to Dryer <br />;r-T <br />M IN <br />or 4/0 SER Alu <br />n <br />200 amp fO <br />150 amp <br />UNDERGROUND <br />Distnnect <br />'L <br />POWER CO. FEED <br />� <br />INTERSYSTEM <br />4 Bare Cu Ground <br />41 <br />BONDING <br />—1 #4 GROUNDING WIRE <br />C <br />TERMINATION PER <br />F_ WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER CO. <br />Bathroom <br />39"AFF <br />Laundry Room <br />36"AFF <br />Exterior Waterproof <br />12" AFF <br />RECEPT. <br />Garage - general purpose <br />44"AFF <br />FOR ALARM <br />Range <br />2"AFF <br />SYSTEM <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the Installation <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance With UL 217, <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined In UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range Is not to be Included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />I ELECTRICAL KEY I <br />�& <br />DUPLEX CONVENIENCE OUTLET <br />I Z±S. <br />PEff: <br />DUPLEX OUTLET ABOVE COUNTER <br />Lz=�L <br />F;E5= <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />�&G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />I Z=1 <br />5-iF <br />HALF -SWITCHED DUPLEX OUTLET <br />I tl;h <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />(bl, <br />THREE-WAY SWITCH <br />-q!4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />�_o <br />WALL MOUNTED LIGHT FIXTURE <br />(§) <br />RECESSED LIGHT FIXTURE <br />+P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />Iwo <br />R, <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />[C�H <br />CHIMES (OPTIONAL) <br />F0 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />H�g <br />PUSH BUTTON SWITCH - DOOR BELL <br />@ <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A. F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />WSJ <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(n <br />(1) PHONE LINE, (1) DATA PORT <br />L <br />UPPER ELECTRICAL PLAN <br />SCALE: Y4"=1'-O" <br />cli <br />Q0 <br />C14 <br />4=) <br />'nee <br />To the best of the Eng' es knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residents[ 7th Edition. Engineer's signature and seal is only for <br />the structural engineeling portions of the drawing pages bearing <br />En9in06f`3 signature and seal. <br />W <br />g <br />0 <br />0 <br />LQ <br />op <br />-, <br />LL <br />, �Lu <br />a <br />U) r- r- <br />g- <br />_j W <br />u a" <br />u:j 6 le <br />Z <br />13 a <br />M a <br />�E- <br />0 <br />0 <br />CZi <br />6 <br />cl: 0 <br />ol� <br />CL <br />ILr- <br />Z <br />IL <br />co <br />L0 Z <br />N <br />0: L4 0 <br />j W <br />Z <br />0110 <br />0 <br />cl- <br />W Ln <br />aX <br />(D <br />4-1 <br />C—/) <br />LL, <br />0 <br />_LU <br />Jim <br />V) <br />C_ <br />re <br />U 6 <br />CO <br />00 <br />< <br />C. <br />E <br />0 <br />E y <br />ro <br />la <br />0 <br />i I <br />C, & <br />E <br />04 to <br />W t <br />0 <br />C: <br />C <br />0 <br />Z <br />Z <br />0 <br />Z <br />R <br />.2 C:) <br />129 <br />(0 <br />M <br />0 <br />C:) <br />> <br />C) <br />< <br />> <br />2 <br />F-- <br />�2 <br />C <br />C: <br />0 <br />%%-.0 <br />(D <br />LO <br />rft--. <br />3: C14 <br />0) <br />rl- <br />114,1 <br />CNI 0 <br />00 <br />00 <br />U) <br />o) <br />C,) <br />0 <br />Z <br />Z <br />E C:) <br />E t <br />0 <br />0 _j <br />M <br />< a <br />_0j) <br />JOB <br />NO: <br />21-2023 <br />SCALE : <br />AS NOTED <br />SHEFIF NO. <br />4.1 <br />